| 1 | Demolition of Brickwork built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions complete all as specified and directed. |
| 2 | M&L for Brick work with sub class 'B' brick straight of curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed. |
| 3 | M&L for Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed. |
| 4 | M&L for providing cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in coping and the like including weathering slightly rounded or chamferred angles and throating complete all as specified and directed. |
| 5 | Dismantling posts or struts (wood, steel or R.C.C.) any section embeded in concrete, including taking out embedded portion and making good disturbed ground complete all as specfied and as directed. |
| 6 | Dismantling fencing wire mesh, any type complete all as specfied andas directed. |
| 7 | Excavating in post holes (or similar holes) each n.exc 0.5cu m, getting out, returning,filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25cm watering & removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and as directed. |
| 8 | M&L for providing cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in Cement concrete in foundations, filling and mass concrete complete all as specified and as directed. |
| 9 | S&F mild steel joist, channel, angle, or tee section, fixed independantly, without connecting plates, etc. as in fencing post conforming to Fe 410 W (gde E-250 quality B) complete all as specified and directed. |
| 10 | Supplying and fixing concertina coll fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m) having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, includlng necessary bolts or G.I. barbed wire tied to anale iron with reinforced barbed tape(R.B.T)/Spring core (2.5mm thick) wire of high tensile strength of 165 kg/sqmm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) complete all as specified and directed. |
| 11 | Supply only Chain link MS galvanised Chainlink fencing of approved size or type, weight as directed per square metre complete all as specified and directed. |
| 12 | Supplying and fixing chain link fencing of P.V.C coated M.S wire mesh roll of 10 gauge of 50 mm x 50 mm size mesh fixing firmly to the existing M.S angle vertical pole of fencing with 8mm dia 50 mm G.I Bolt and G.I flat 35 mm x 4 mm/100mm long G.I wire cost includes all required materials, fixtures, labour and machinery etc. complete all as specified and directed. |
| 13 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 14 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. NOTE: Each line wire to be measured |
| 15 | S&F Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (Annealed) not less than 0.90 mm dia or securing with clips quality conforming to round bar bars complete all as specified and directed. |
| 16 | S&F flat iron for securing wire mesh etc. posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 17 | S&F MS screw bolt (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square n exc 5 cm long dia of neck 5 to 10 mm complete all as specified and directed. |
| 18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 19 | S&F Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-290 Gde E-165 (R) complete all as specified and as directed. |
| 20 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed. |
| 21 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed. |
| 22 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed. |
| 23 | S&F for framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars, barred iron doors, iron gate, ladders; framed balusters, ways : railing : frame work of watertanks and similar work conforming Fe-290, Gde E-165 complete all as specified and directed. |
| 24 | M&L for PCC (1:2:4) type B-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 25 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. |
| 26 | All as per BOQ Serial item No 25 above but add or deduct for each 25 mm girth or part thereof over or under 30cm complete all as specified and directed. |
| 27 | M&L for providing RCPC factory made 75mm precast RCC cover slab of 3MT load bearing capacity conforming to IS : 12592 (Grade M-25) complete all as specified and directed. |
| 28 | Demolition of cement concrete (unreinforced) of any descriptions, in Ground floors (Floor Topping, Sub Base etc) not exc 150mm thick, above or below ground level complete all as specified and directed. |
| 29 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in fondations, filling and mass concrete complete all as specified and directed. |
| 30 | M&L for 50 mm thick Cement concrete type C- 2, 1:3:6 (using 40mm graded stone aggregate) as in sub base floor, hard standing and like complete all as specified and directed. |
| 31 | M&L for pre-polished cement concrete (designed & coloured) chequered tiles glossy finish of area n exc 0.16 sqm as in floor set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of the tiles and laid over & including 15 mm thick screed bed in cement mortar (1:6) over 40mm PCC (1:2:4) type B-0 complete all as specified and directed. |
| 32 | M&L for silver sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 33 | M&L for 60 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and directed. |
| 34 | M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggregates as in plinth protection / paving, etc surface finished even & smooth without using extra cement as complete all as specified and directed. |
| 35 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store complete all as specified and directed. |
| 36 | M&L for glazed ceramic (coloured) tiles of size 450x300 6-7mm thick as in vertical surface/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 37 | M&L for Anti-skid joint free ceramic coloured tiles area of each tiles (Square/rectangular) exc 0.11 sqm but n. exc 0.18 sqm 7 to 8 mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. Note: Screed bed shall be measured and paid separately |
| 38 | M&L for screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified and directed. |
| 39 | M&L for bedding layer of mortar 10 mm thick in CM 1:3 for laying wall/dado finishes complete all as specified and directed. |
| 40 | Taking down cement plaster or lime plaster of any description from stone or brick wall/ ceiling etc including raking out joints, hacking for key scrubbing down with water including necessary scaffoldings complete all as specified and directed. |
| 41 | M&L for rendering 15 mm thick in CM 1:4 on brick surface finishing even and smooth (with out using extra cement) etc complete all as specified and directed. |
| 42 | M&L for rendering 20mm thick with CM (1:6) on brick work or concrete surfaces finished even and smooth without using extra cement including necessary scaffoldings complete all as specified and as directed. |
| 43 | M&L for rendering 5mm thick in (1:3) cm on fair faces of ceiling and finish smooth without using extra cement including necessary scaffoldings complete all as specified and directed. |
| 44 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 45 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (of approved colour) having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 46 | S&F prepainted galvalume aluminium zinc coating plain steel sheet 0.50 mm thick (of approved colour) having tensile strength of 550 MPa as in roof ridges /cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 47 | Dismantling of stone slabs and tiles of any description or thickness in floors,aprons etc laid, bedded & pointed in any mortar complete all as specified and directed. |
| 48 | M&L for Granite(of any type) 18-20mm thick slab laid on floor machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone over & including 15 mm thick screed bed in cement mortar (1:6) including grinding & polishing complete all as specified and as directed. |
| 49 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 50 | S&F rotational moulded polythene water storage tank 1000 litre capacity ISI marked (cylindrical, vertical, double layered with closed top) hoisted and fixed in position including PVC float valve 20mm bore weight not less than 210 gms including dismantling of old unserviceable water tank, removing from site, complete all as specified and directed. |
| 51 | S&F 2000 Litre capacity rotational moulded polyethylene water storage tanks (multilayer.cylindrical |vertical with closed top) with and including 50 mm dia PVC float valve hoisted and fixed in position complete including dismantling of old unserviceable water tank, removing from site, complete all as specified and directed. |
| 52 | M&L for applying one coat of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm on wall surfaces complete all as specified and directed. |
| 53 | M&L for applying two or more coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new wall surfaces complete all as specified & as directed |
| 54 | Preparation of old painted surfaces of steel & iron surface of any description over 10 Cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. |
| 55 | Preparing of new steel & iron surface of any description over 10 Cm width or girth and M&L for applying two coats of synthetic enamelled paint over & including a coat of red oxide primer complete all as specified and as directed. |
| 56 | Preparation of plastered and unplastered surfaces of old decorated walls and M&L for applying one coat of acrylic oil emulsion distemper complete all as specified and directed. |
| 57 | M&L for 1mm thick wall care putty on wall including rubbing with sand paper to achieve a smooth surface & sharp straight edges etc. complete all as specified & as directed. |
| 58 | Preparation of newly plastered wall surface and M&L for applying two coats of oil bound distemper over a coat of primer on complete all as specified and directed. |
| 59 | Preparation of newly plastered ceiling surface and M&L for applying three coats of white wash complete all as specified and directed. |
| 60 | Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means, including loading, tranporting, unloading to approved municipal dumping ground outside MoD land where directed complete all as specified and directed. Please Enable Macros to View BoQ information |