| 1 | M&L for cleaning of RCC over head tank of the capacities of tank 50000 gallons staging 15M to 21 M height by brooming the side wall /bottom and ceiling dome of tank, removing all fungus ,scales ,dust, sludge etc from inside of the tank and removing the materials to a distance exc 50 M n.exc 100 M washing tank from inside with water and dis-infection chemical such as bleaching powder etc. as directed, applying one coat of white wash on all internal surfaces of the tank, writing date of cleaning, CA No, Name of contractor etc with using synthetic enamel black/white paint, applying one coat of synthetic enamel black paint on all inlet, outlet, washout and overflow pipes including sluice valves complete all as specified & directed. by Engr-in-Charge |
| 2 | All as per item No. 1 above but capacity of tank 25000 gallons. |
| 3 | All as per item No. 1 above but capacity of tank 100000 gallons. |
| 4 | M&L for cleaning of under ground sump capacity of sump 10000 gallons by removing all fungus, scales, dust, sludge etc from inside the sump and removing the materials to a distance exc 50 M and n. exc 100 M including washing the walls, bottom of the sump with water and dis-infection chemical such as bleaching powder etc, writing date of cleaning , CA No, Name of contractor with using synthetic enamel black/white paint, applying one coat of synthetic enamel black paint on all inlet, outlet and overflow pipes including sluice/ gate valves up to pump complete all as specified & directed. by Engr-in-Charge |
| 5 | All as per item No.4 above but capacity of sump 20000/25000 gallons. |
| 6 | All as per item No. 4 above but capacity of sump 50000 to 70000 gallons. |
| 7 | All as per item No. 4 above but capacity of sump 100000 gallons. |
| 8 | All as per item No. 4 above but capacity of sump 200000 gallons. |
| 9 | All as per item No. 4 above but capacity of sump 350000 gallons. |
| 10 | All as per item No. 4 above but capacity of sump 400000 gallons. |
| 11 | All as per item No. 4 above but capacity of sump 550000 gallons. |
| 12 | All as per item No. 4 above but capacity of sump 800000 gallons.Note for item No 01 to 11 : (a) Removal of remaining sludge from the flor with the help of industrial vacuum cleaner : (b) Removal of remaining sludge with the help of imported heavy duty industrial vacuum, cleaner and sludge sucker having max power of 1200 watt with suitable heavy duty rugged motor.(c) Imported sludge sucker should be a part of the high pressure system which sucks and throws the same out of the tank this must handle solid partials as well.(d) All safety gadgets like safety bells, special safety belts, special safety ladders helmets, heavy duty gum boots, electric safety gloves and special working gloves saftety masks, aprons etc. for complete security and operation be used by well trained person. |
| 13 | S&F in repairs aviation obstruction light luminaries fittings having integral LED aviation light comprising of aluminium housing with polycorbonate enclosure at the top of OHT and making necessary electric connection and fixing arrangement of aviation lights complete all as specified and directed by Engr-in-Charge |
| 14 | S&F in repairs electronic water level indicator,5 stage, showing 0%, 25%, 50%, 75% & 100% (Sensor system with LED display) complete all as specified and directed by Engr-in-Charge |
| 15 | S&F in repair on wall/surface or on top of over head tank or laying in trenches PVC insulated 2.5 Sqmm, 3 core copper conductor 1100 Volts grade cable drawn through PVC conduit pipe of 20mm dia complete all as specified and directed by Engr-in-Charge |
| 16 | All as per item No. 15 above but 1.5 Sqmm, 06 Core. |
| 17 | S&F in repair pressure gauge 0 to 7 Kg/cm2 with necessary fixing arrangement complete all as specified and directed by Engr-in-Charge |
| 18 | M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm size, buried directly in ground (earth pit not less than 3.25M deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to and including galvanized steel earth strip 32 x 6mm, including 40mm bore GI light grade protection pipe as earth lead strip connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150mm thick alternate layers of charcoal or cock dust & common salt, 20mm bore medium grade GI watering pipe, cover 50mm thick of precast RCC, GI wire mesh, GI sheet funnel necessary excavation in soft/loose soil and deposited the surplus soil to a distance n.exc 50 mtr away from starting point complete all as specified and shown in electrical plate No 3 of MES standard schedule of rates 2009 Part-I complete all as specified and directed by Engr-in-Charge |
| 19 | Supply and fix in repairs GI strip 32x6mm buried in ground including taking out/down old existing strip complete all as specified and directed by Engr-in-Charge |
| 20 | Supply and fix in repairs air terminal single pointed aluminium rod 12mm dia and 300mm long including taking down of old existing terminal complete all as specified and directed by Engr-in-Charge |
| 21 | S&F in repairs test point terminal block made of gun metal or phosphoras bronze size 75x75x25mm drilled and screwed complete including taking down of old existing test point complete all as specified and directed by Engr-in-Charge |
| 22 | Supply and fix in repairs aluminium strip 25x3 mm with saddles and fixing screw etc for roof, OHT and down conductors and above ground complete including taking down of old existing complete all as specified and directed by Engr-in-Charge |
| 23 | M&L for Mild steel, plain, black sheet 2.0 mm thick for covering to doors, shutters, chowkats (frames), water tanks, water troughs, ducts and funnels etc cut to size edges beaded if directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members etc with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc as required. |
| 24 | Supply, fabrication and fixing of MS equal angel/MS channel/angel C section etc conforming to GDE FE 410- W as hip and jack rafter, purlins,ladder etc where connected to common rafters and running rails fixed with other connecting plates etc including necessary welding, cutting etc and two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge |
| 25 | Sampling and testing of water for the conformation of Desirable / permissible limit of following requirements for \\"DRINKING WATER\\" as per IS : 10500-1991 from govt approved laboratory including transportaion of warer complete all as specified and directed(a) Bacterioligical requirements: Testing of coliform Organisms/100ml.(b) Chemical requirements : Testing of colour hazen unit max odour taste turbidity NTU max, pH value, total hardness (as CaCo3) mg/lmax, iron (as FE) mg/l max.(c) Desorable Charactreristics : Testing of dissolved solids mg/l max, Calcium (as CA mg/l mnax, magnesium (as Mg) mg/l max, Copper (as Cu)mg/l max, Manganese (as Mn) mg/l max, Shulphate (as SO4) mg/l, max, nitrate (as NO3) Mg/l phenolic compound mg/l max, mercury (as Mg) mg/l max, Cadmium (as Cd) Mg/l max, Selenium (as Se) mg/l max, Arsenic (as As) mg/l max, Cyanide (as CN) mg/l max, Lead (as Pb) mg/l max, Zinc (as An) mg/l max, Chromium (as Cr+( mg/l max, Mineral Oil, mg/l max Note :- Testing of raw water is mandetory at every quarter failing which a recovary of Rs 1000.00 per test shall be recovered from the contractor. |
| 26 | M&L in repairs rotational modulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of 1000 Ltr size all as specidied and directed by Engr-in-Charge. |
| 27 | S&F in repairs circular cover for water storage tank, any capacity made out of 1 mm thick GI sheet PVC water storage tank fix with suitable screws (indoor to protact monkey menance) design and size as per sample kept in GE office or as approved by Engr-in-Charge complete all as specified and directed by Engr-in-Charge |
| 28 | M&L for reapair to header 300 mm using mild steel, plain black sheet, 4 mm thick in wall cladding, cut to size, fixed to headers at various locations of water supply installations with 40 mm lap join by welding seams, including bending or turning up, mitred angles and fixing of sluice valve etc as required complete all as specified and directed by Engr-in charge. |
| 29 | M&L for reapair to header 250 mm using mild steel, plain black sheet, 4 mm thick in wall cladding, cut to size, fixed to headers at various locations of water supply installations with 40 mm lap join by welding seams, including bending or turning up, mitred angles and fixing of sluice valve etc as required complete all as specified and directed by Engr-in charge. |
| 30 | S&F in repair MS Pipe ERW Steel including specials( bends, collars, tapers, reducers), nominal 300 mm dia as per IS 3589 (1981) thickness 5.4 mm complete all as specified and directed by Engr-in charge.Note:- Rates are inclusive of all cutting, welding & fittings, nut, bolts, washer and packing etc |
| 31 | All as per item No. 30 above but 250 mm dia |
| 32 | All as per item No. 30 above but 150 mm dia Please Enable Macros to View BoQ information |
| 33 | All as per item No. 30 above but 150 mm dia Please Enable Macros to View BoQ information |