| 1 | PART-A (Electrical Portion ) |
| 2 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 3 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 4 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 5 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.312 X 70 sq. mm (38mm) |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3% X 150 sq. mm (50mm) |
| 8 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.312 X 185 sq. mm (57mm) |
| 9 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.312 X 400 sq. mm (82mm) |
| 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm (35mm) |
| 11 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/ X 70 sq. mm |
| 12 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.31/ X 150 sq. mm |
| 13 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3% X 185 sq. mm |
| 14 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3% X 400 sq. mm |
| 15 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 50 sq. mm |
| 16 | Supply of pvc insulated heavy duty power cable marked with Alu. Stranded /solid conductor ARMOURED 4 CORE 1.1KV, 50 sqmm as per instruction of Engineer I/c |
| 17 | Supply of pvc insulated heavy duty power cable marked with Alu. Stranded /solid conductor ARMOURED 4 CORE 1.1KV, 70 sqmm as per instruction of Engineer I/c |
| 18 | Supply of pvc insulated heavy duty power cable marked with Alu. Stranded /solid conductor ARMOURED 4 CORE 1.1KV, 185 sqmm as per instruction of Engineer I/c |
| 19 | Supply of pvc insulated heavy duty power cable marked with Alu. Stranded /solid conductor ARMOURED 4 CORE 1.1KV, 400 sqmm as per instruction of Engineer I/c |
| 20 | Supply of pvc insulated heavy duty power cable marked with Alu. Stranded /solid conductor ARMOURED 4 CORE 1.1KV, 150 sqmm as per instruction of Engineer I/c |
| 21 | Providing & Fixing of cable marker tie tags as per instruction of Engineer I/c |
| 22 | PART-B (Cable Trench (civil) |
| 23 | Cable trench formation of referred section and following points with scope of work including minor civil works like breaking of floor/walls, scaling of floor/wall openings, accessories like hardwares, clamps, etc as required for fixing arrangement. Any such item or work which although are not specifically indicated in the mentioned scope but are required for the completeness of the work as well as satisfactory operation of scheme are deemed to be included in the scope.* All RCC shall be of grade M25 unless noted otherwise* Lifting hook shall be provided in every tenth cover slab* Necessary openings shall be provided at appropriate locations to take out cables* For actual depth of trenches refere cable trench layout* FGL denotes finished ground level in cable trench layout* All cable trenches shall have slope of minimum 1:1000 in the direction of main run away* Earthing conductor 50x6 MS flat shall be welded to the cable supporting structure before installation of cable* All steel structures shall be painted with anti-corrosive paint over a coat of suitable primer before installtion of cables, earthing conductor shall be painted red* Construction joint shall be provided at 30m or as per the site requirement but not excedding 30m* All support angles shall be 50x50x6* Anchoring flat 75x6 shall be provided as each support angle point* Earthing conductor 'E' shall be provided on the top tier of each cable trench section* In case of expansive soil is encountered at founding level, it shall be removed to a minimum depth of 300 mm and shall be replaced by well compacted locally available C.N.S. material* All reinforcement steel bars shall conform to IS: 1786-1895 of grade Fe500* Only written dimensions in layout to be followed and all dimentions are in mm Cable trench (Section 1-1) |
| 24 | Cable trench formation of referred section and following points with scope of work including minor civil works like breaking of floor/walls, scaling of floor/wall openings, accessories like hardwares, clamps, etc as required for fixing arrangement. Any such item or work which although are not specifically indicated in the mentioned scope but are required for the completeness of the work as well as satisfactory operation of scheme are deemed to be included in the scope.* All RCC shall be of grade M25 unless noted otherwise* Lifting hook shall be provided in every tenth cover slab* Necessary openings shall be provided at appropriate locations to take out cables* For actual depth of trenches refere cable trench layout* FGL denotes finished ground level in cable trench layout* All cable trenches shall have slope of minimum 1:1000 in the direction of main run away* Earthing conductor 50x6 MS flat shall be welded to the cable supporting structure before installation of cable* All steel structures shall be painted with anti-corrosive paint over a coat of suitable primer before installtion of cables, earthing conductor shall be painted red* Construction joint shall be provided at 30m or as per the site requirement but not excedding 30m* All support angles shall be 50x50x6* Anchoring flat 75x6 shall be provided as each support angle point* Earthing conductor 'E' shall be provided on the top tier of each cable trench section* In case of expansive soil is encountered at founding level, it shall be removed to a minimum depth of 300 mm and shall be replaced by well compacted locally available C.N.S. material* All reinforcement steel bars shall conform to IS: 1786-1895 of grade Fe500* Only written dimensions in layout to be followed and all dimentions are in mm Cable trench (Section 2-2) |
| 25 | Total Impact of GST for the Purpose of CTC Please Enable Macros to View BoQ information |