| 1 | Repair, servicing & comprehensive Maintenance of Split type Air-Conditioning Units LG Make having following capacity including maintenance of voltage stabilizer and all other accessories with sleeves, drain pipe, insulation and battens etc. with servicing, cleaning the filters in routine intervels i.e. 04 Nos. services, when required throughout the year excluding replacement of the compressor of A.C. units which are beyond repair. The repair and maintenance has been done as per instructions and directions to the best satisfaction of Engineer-in-charge. |
| 2 | Split type A.C. units 2 TR capacity |
| 3 | Repair, servicing & comprehensive Maintenance of Window Air-Conditioning Units Voltas Make having following capacity i.e. rackout of these units for servicing including washing of filters in routine intervels i.e. 04 Nos. services throughout a year. with the time period of three months and reinstallation of these units after necessary PCB testing, fan motor, swing motor, drain pipe, refrigerant pressure testing, testing of temperature senser and all other wiring including stabilizer wiring etc. and emergency call attending services during the any type of fault in air-conditioning units as required complete in all respects and to the best satisfaction of Engineer-in-charge. |
| 4 | Window type A.C. units 1.5 T.R capacity |
| 5 | Replenishment/charging of refrigerant R-22/32 (Gas) in split air-conditioning units as required complete in all respects as per the direction and to the best satisfaction of Engineer-in-charge. |
| 6 | Supplying and fixing of following accessories suitable for 1.5/2 Ton capacity split type air-conditioning units as required complete in all respects and as per directions of Engineer-in-charge. |
| 7 | Providing & fixing of extra copper tubes for refrigerant and condensate (1/4\\" x 1/2\\") for 1.5 T.R. split type A.C. units and wiring with suitable size of HRFRLS copper conductor single core cables, including the cost of insulation etc. as required complete in all respects. |
| 8 | Supplying, installation, testing and commissioning of compressor of following capacity suitable for required size/ capacity air-conditioning units complete in all respects and to the best satisfaction in Engineer-in-charge. |
| 9 | Compressor for 2 Ton A.C. unit |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 11 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit having wall thickness 2.0mm as required |
| 12 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 13 | Acceptable Make |
| 14 | Copper Wire/Telephone Cable/UTP cable/ TV Cable:Finolex/KEI/ Polycab/ RR Kabel/ Havells/ Grandlay (duly ISI Marked) |
| 15 | Aluminium and copper XLPE Power Cables Armoured/Unarmoured:Finolex/KEI/ Polycab/ RR Kabel/ Havells/ Grandlay (duly ISI Marked) |
| 16 | Cat 6/ 6A Cable:Molex/ Digilink/ Schneider/ Belden/ Legrand |
| 17 | Modular Switch, Socket, Fan regulator, RJ-45, Cable TV socket, Data outlet socket, GI boxes etc. and accessories:Legrand : ARTEOR Honeywell : ORNA Panasonic : EUROPA Schinedier : ZENCELO |
| 18 | PVC Conduit with accessories:Finolex/ Supreme/ BEC/ NIC/ Polycab/ AKG (All shall be Min. 2mm thick and ISI marked) |
| 19 | MS Conduit with accessories:AKG/ NIC/ BEC/ RMCON (Note: The accessories shall be same that of conduit pipe and will comply to IS/ 4768 part 2 2003) |
| 20 | GI Pipe (for pipe pole and other items):Tata/ Jindal/ SAIL (All shall be ISI marked) |
| 21 | OFC cable and accessories:Belden/ D Link/ Tyco |
| 22 | Gland:Comet/ Dowells |
| 23 | HDPE/ DWC pipe:REX/ Duraline/ Duraplast/ Triputi |
| 24 | MCB/MCB DB/ Isolator/ RCCB/ Industrial Socket |
| 25 | MCCBs/ RCCBs/4 Pole Power contractor /Change Over:Legrand /Siemens/ Schneider/ L&T /ABB |
| 26 | 600 mm LED mirror light:L&T D Sine/ Schneider Compact NSX/ Legrand DPX3/ Siemens 2 VL/ ABB |
| 27 | LED bulk head fitting:Phillips/ Wipro/ Trilux/ Havells/ LT/ Panasonic |
| 28 | LED downlighter:Phillips/ Wipro/ LT/ Regent/ Panasonic |
| 29 | 36 watt 2'x2' panel light:Phillips/ Wipro/ LT/ Regent/ Panasonic |
| 30 | 36 watt LED batten light:Phillips/ Wipro/ LT/ Regent/ Panasonic |
| 31 | LED bed side light |
| 32 | Decorative wall light with E27 holder:Phillips/ Trilux/ Regent/ LT/ Lustre/ Panasonic/ wipro |
| 33 | 250/200 mm fresh air fan:USHA/ Khaitan/ Crompton/ Almonard |
| 34 | 300 mm sweep heavy duty exhaust fan:Usha/ Almonard/ Havells/ Orient/Bajaj/ Crompton |
| 35 | 3 /25 Ltrs. Geysers::Recold/ Bajaj/ Havells/ Crompton/ AO Smith/ Venus |
| 36 | 2 compartment energy meter board panel feeder pillar:Kalyani Switch Gear/ Power Associates/ Pristine/ Milestone/ ADLEC/ Tricolite/ ASPL/ CMKL |
| 37 | Ceiling fan:Usha/ Almonard/ Havells/ Orient/Bajaj/ Crompton |
| 38 | Or as per given against item or work and as per approval of Engineer-in-Charge Please Enable Macros to View BoQ information |