| 1 | Cat (A) -Items to be supply and fixing |
| 2 | Excavation in trenches n.exc.1.5 meter wide and 1.5 meter depth in soft loose soil ( to be carried out manually) and getting out for laying of L T. cable in underground , all as per the direction of Engineer-In-charge. |
| 3 | Cutting opening / Demolition of cement concrete of any description, all as per the direction of Engineer-In-Charge |
| 4 | M& L for provision of sand cushion of 07 cm. thick for L.T. cable, all as per the direction of Engineer-In-charge. |
| 5 | Supply, laying in excavated cable trenches and testing of PVC insulated galvanized steel flat strip armoured and overall PVC sheathed heavy duty electric cable with stranded Aluminium conductor, 1100 volt grade of size 3&1/2 core, 120 sq. mm, confirming to IS- 1554 ( P-1)/ 1988. (Make- Unistar / Finolex / Havells/ RPG/ KEI/ RR ), all as per the direction of Engineer-In-charge. NOTE – Inspection and testing of cable will be carried out by factory representative at manufacturer’s premises only. |
| 6 | Supply, laying in excavated cable trenches and testing of PVC insulated galvanized steel flat strip armoured and overall PVC sheathed heavy duty electric cable with stranded Aluminium conductor, 1100 volt grade of size 4 core, 16 sq. mm, confirming to IS- 1554 ( P-1)/ 1988. (Make- Unistar / Finolex / Havells/ RPG/KEI/ RR ) , all as per the direction of Engineer-In-charge. NOTE – Inspection and testing of cable will be carried out by factory representative at manufacturer’s premises only. |
| 7 | Supply, laying in excavated cable trenches and testing of PVC insulated galvanized steel flat strip / round wire armoured and overall PVC sheathed heavy duty electric cable with stranded Aluminium conductor, 1100 volt grade of size 2 core, 10 sq. mm, confirming to IS- 1554 ( P-1)/ 1988. (Make- Unistar / Finolex / Havells / RPG / KEI /RR ) , all as per the direction of Engineer-In-charge. NOTE – Inspection and testing of cable will be carried out by factory representative at manufacturer’s premises only. |
| 8 | Supply and laying un-reinforced precast cement concrete cable covers of class LV, type 1, flat size 250 X 150 X 40 mm duly marked ‘ELECTRIC‘ as per IS 5820- 1970, all as per the direction of Engineer-In-charge |
| 9 | Returning, filling in including spreading, levelling and well ramming in layers of excavated soft loose soil in trenches and making good distributed surface all as per the direction of Engineer-In-charge. |
| 10 | Supply and Fixing of Earthing complete with G.I. earth plate electrode 600 X 600 X 6 mm thick buried directly in the ground vertically to a depth not less than 2.25 meter below normal ground level with top edge of the earth plate at a depth not less than 1.5 meter below ground level, connected to galvanised earth strip 25X4 mm as earthing lead upto test point and connection point within 7.5 meter from earth pit, all as specified and shown in electrical plate no. 3 of SSR part 1 and testing on completion, all as per the direction of Engineer-In-charge. |
| 11 | S&F, of GI steel tubes of medium grade of 20 mm bore as per IS- 1239/1990 for watering pipe in earthing chamber, all as per the direction of Engineer-In-charge. |
| 12 | S&F, of GI steel tubes of medium grade of 40 mm bore as per IS- 1239/1990 for protection of cable and earthing strip, all as per the direction of Engineer-In-charge. |
| 13 | S&F, of GI steel tubes of medium grade of 80 mm bore as per IS- 1239/1990 for protection of cable, all as per the direction of Engineer-In-charge. |
| 14 | Supply & fixing of M.S. clamps of suitable required sizes and as per required qty. fabricated from M.S. flat of 410 SP grade 40X05 mm size and M.S. Hexagonal head nut bolts with two washers of various sizes and lengths as per requirement for fixing of cut out boxes on pole & protection pipe etc. all as per the direction of Engineer-In- charge |
| 15 | Drilling 15 mm diameter hole on existing installed Steel tubular L.T. poles of street light at site, all as per the direction of Engineer-In-charge. |
| 16 | Supply and drawing PVC insulated copper conductor single core cable, 2X 1.5 Sq. mm + 1X1.5 Sq.mm in each meter or 3 core TRS flexible cable of 1.5 sq. mm confirming to IS – 694 / 1988 from cut out box to street light fitting , all as per the direction of Engineer-In-charge. |
| 17 | Dismantling of street light fitting from pole bracket for connection of new supply cable and refixing after connection, all as per the direction of Engineer-In-charge. |
| 18 | M&L for provision of cement concrete of type- B2, 1:2:4, 40 mm graded aggregate for repairing of broken cement concrete, foundation, earth pit chamber and cover etc. all as per the direction of Engineer-In-charge. |
| 19 | M&L for provision of mild steel TMT bars of 8 mm dia. including m.s. binding wire for reinforcement in PCC covers of earth pit. Each cover require 10 pc of 0.4 meter ( 8 for mesh & 2 for handle) etc. all as per the direction of Engineer-In-charge. |
| 20 | Dismantling of old damaged ACSR or AAC conductor of old L.T. overhead line, all as per the direction of Engineer-In-charge. |
| 21 | Dismantling Pin & shackle insulators on existing pole , all as per the direction of Engineer-In-charge. |
| 22 | Dismantling cross arms of m.s. channels or angle irons fixed on existing poles, all as per the direction of Engineer-In-charge. |
| 23 | S&F of M S boxes for out- door use of size L- 250 X H- 300 X W- 200 mm fabricated from 2 mm thick m.s. sheet, having rain shield on top and front hinged door with panel key type locking arrangement & key. Box should have suitable fixing arrangement to fix on pole with the help of 02 clamps. Holes at bottom for 25 mm cable glands- 02 no, 15 mm hole on back side- 01 No, dully painted with smoke grey paint, complete fixed with (a) Porcelain / SMC insulators of 30 A capacity - 04 Nos, (b) G.I. coated m.s. bolt of 8 mm dia,50 mm long - 01 No. and nut - 03 no. with 05 washers – 04 set ( to be fixed in insulators) (c) 6 Amp. 2 pole MCB - 02 No.(d)25 mm flange type cable glands - 02 No. (e) Al. lugs of 16 Sq.mm- 08 Nos. (f) Earthing terminals - 02 No complete including termination and connection of cable in boxes, all as per the direction of Engineer-In-charge. |
| 24 | Supply, installation & connection of out door type feeder pillar panel board with front plain hinged doors, fabricated from 2.0 mm thick sheet steel with m.s. channel base frame. Panel should be dust & vermin proof ( even though front plain door remains in open condition) and pre-treated and spray painted with smoke grey paint, panel should consisting of following(a) SDF unit TPN with DIN type fuse link - Size1, 200 Amp.- 02 No (b) SDF unit TPN with DIN type fuse link Size00 ,125 Amp, – 01 No(c) Al Flat Bus bar of 200 Amp. Capacity- 4 no. of suitable length, (0.75Amp/sq. mm)(d) 50 mm Flange type brass cable gland - 02 No.(e) 25 mm Flange type brass cable gland - 01 No. (f) Al. tubular terminal ends of size -120 & 10 Sq. mm - 08 nos of each size. complete with construction of one meter height brick foundation above ground level for installation of panel , all as per the direction of Engineer-In-charge. |
| 25 | Supply, installation &connection of out door type feeder pillar panel board with front plain hinged doors, fabricated from 2.0 mm thick sheet steel with m.s. channel base frame. Panel should be pre-treated and spray painted with smoke grey paint consisting of following(a) SDF unit TPN with DIN type, fuse link -Size1, 200 Amp.- 02 No (b)street light controlling system consisting of SDF unit TPN with DIN type, fuse link Size00 ,125 Amp, – 01 No, 3 pole power contactor 80 Amp.- 01 No, 3 pole, 32 Amp. MCB- 02 no. for connection of 2 circuit of street lighting, Digital time switch- 01 no, Auto /Manual selector switch- 01 no. (c) Al Flat Bus bar of 200 Amp. Capacity- 4 no. of suitable length. (0.75Amp/sq. mm)(d) 50 mm Flange type brass cable gland - 02 No. (e) 25 mm Flange type brass cable gland - 02 No. (f) Al. tubular terminal ends of size -120 & 10 Sq. mm - 08 nos of each size. complete with construction of one meter height brick foundation for installation of panel , all as per the direction of Engineer-In-charge. |
| 26 | S& F of heat shrinkable, straight through cable jointing kit , for 3 ½ core 120 Sq.mm Al. conductor PVC insulated cable ( Make- REPL/Raychem RPG/ CCI/ Birla 3M) complete as per the direction of Engineer-In-Charge. |
| 27 | S&F of Cast iron cable route marker of size 100 mm diameter duly marked as “ L T CABLE ” fixed on one meter long 1’’ m s angle etc. as per the direction of Engineer-In-charge. |
| 28 | Cat (B) - Buy Back Items |
| 29 | Credit to contractor for old damaged Aluminium conductor removed , all as per the direction of Engineer-In-charge. |
| 30 | Credit to contractor for old removed m.s. scrap material which consists of m s channels, angles, flats , all as per the direction of Engineer-In-charge. Please Enable Macros to View BoQ information |