| Sl. No. | Item Description |
| 1 | Construction of ESR (8 no ESRs ) |
| 2 | Design, Supply, Construction, Testing & Commisioning of Mass Balancing Reservoir (MBR) and Elevated Service Reservoirs (ESR's) and under ground reservoir(UGR) at Town all complete as per the direction of Engineer-in-charge. |
| 3 | Proposed ESR at DMA -3(1200 KL)Staging - 20m |
| 4 | Proposed ESR at DMA -4 A (1100 KL)Staging - 20m |
| 5 | Proposed ESR at DMA -5( 750 KL)Staging - 25m |
| 6 | Proposed ESR at DMA -8(250 KL)Staging - 25m |
| 7 | Proposed ESR at DMA -9(1100 KL)Staging - 30m |
| 8 | Proposed ESR at DMA -11A(1000 KL)Staging - 25m |
| 9 | Proposed ESR at DMA -10( 2100 KL)Staging - 25m |
| 10 | Proposed ESR at DMA -15 at Reserved Colony( 350 KL)Staging - 25m |
| 11 | Design, Drawing and Construction of RCC frame structure with brick work wall single stored building for PLC and Chlorination Room with Toilet block, PH work and Electrification Work and chair table, almera,etc at ESR site(for DMA-01,03,04,05,06,07, 08,09,11,12, 13, 16), complete as per drawing and specification and the direction of Engineer-in-charge |
| 12 | Design, Drawing and Construction of RCC frame structure with brick work wall single stored building(Billing and Revenue Server Room, Master Control Center System Room, Electrical Sysstem Room, Customer Care Officer Room, Customer and Guest Waiting Room and Female amd Male Toilet) for SCADA control room with Toilet block and Laboratory at MBR site, complete as per the direction of Engineer-in-charge |
| 13 | Supply of all material, labour, T&P for PH work and Electrification Work and chair table, almera,etc of SCADA control room, complete as per the direction of Engineer-in-charge |
| 14 | 10 ltr capacity flushing L/L cistern (Make:- Parryware/Hindware/Equivalent make with approval of the authority) with PVC make all internal fittings with flush bend.(White) |
| 15 | EWC standard seat cover (Make:- Parryware/Hindware/Equivalent make with approval of the authority) |
| 16 | 15mm CP Twin Bib Cock long body (Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 17 | Health Faucet (1.00 mt)(Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 18 | 15mm dia CP/Brass Angle Stop Cock (Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 19 | 15mm dia CP/Brass Long Body Bib-cock (Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 20 | 20mm dia CP/Brass Concealed Stop-cock (Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 21 | 20 mm x 600 mm long CP Towel Rail (Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 22 | Cp glass shelf with glass : (Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 23 | 15mm dia CP revolving shower with arm (Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 24 | CP Soap Holder (Make:-Jaguar/Plaza/Amber Delux/Equivalent make with approval of the authority) |
| 25 | 125 mm dia CP Gratting |
| 26 | Framed Mirror |
| 27 | Supplying all materials labour &T&P for providing fitting and fixing of 22\\"x16\\" size W.H Basin with 15 mm dia pillar cock , 15 x600 mm Connection pipe ,32 x 125 mm CP waste ,32 x 1150 mm waste pipe , etc all complete as per P.H specification and direction of E.I.C. (Make:- Parryware/Hindware/Nycer/ Equivalent make with approval of the authority) |
| 28 | Fixing wash down water closet (European type W.C pan ) with integral 'S' or 'P' trap conforming to IS 2556 Part 8-2004 to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specifcation. (Make:- Parryware/Hindware/Nycer/ Equivalent make with approval of the authority) |
| 29 | Supplying all materials,labour and T & P for construction of 1.2 mtr dia × 1.5 mtr depth RCC ring soak - way pit filled with brick bats incuding earth work in excavation and refilling of cavity around the pit & making perforated hole on the wall of soak way pit for soaking of waste water etc.all complete as per approved design and drawing |
| 30 | RCC ring Soak way pit of size 1.20mtr dia x 1.65 mtr deep |
| 31 | Cutitng grooves in pucca floor and wall for taking G.I /PVC pipe etc all complete |
| 32 | Providing & fixing to wall or ceiling and floor UPVC pipes ASTM-D of conforming to IS no 4985/1785 of the following nominal bore, the fittings and clamps including making good the wall,celling and floor, all complete as pe specification internal ) |
| 33 | 20mm. Dia PVC pipe in wall |
| 34 | 25mm. Dia PVC pipe in trench |
| 35 | 25mmdia UPVC ball valve with metal ball |
| 36 | 25mmdia brass Horizental NRV |
| 37 | Supplying fitting & fixing of the following H.C.I./ P.V.C S.W.R pipe & fittings as per PH specification & direction of EIC. |
| 38 | 110mm dia PVC SWR Pipe |
| 39 | 110mm dia PVC SWR Door Bend |
| 40 | 110mm dia PVC SWR Plain Bend |
| 41 | 110mm dia PVC SWR P Trap |
| 42 | 110mm dia PVC SWR Cowl |
| 43 | 110mm dia PVC SWR Clamp |
| 44 | Supplying all materials,labour and T & P for construction of 20 users Brick masonary Septic tank including earth work in excavation and refilling of cavity around the pit etc.all complete as per approved design and drawing. |
| 45 | Procesees /surface wiring to light point /fan point e fan point /call bell point with 1.50 sqmm FR PVC insulated single core multi starand copper consuctor of ISI marked with 20mm dia non -m MS box with 1.5 sqmm FR PVC insulated single core multistrand copper consuctor as earth wire including al laceessories and conenectin (Make:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) Light Points |
| 46 | Group -A |
| 47 | Group -B |
| 48 | 5 A Plug point |
| 49 | Fan point ( Group - A) |
| 50 | Supplying all materials labour & T & P for fitting & fixing of following electrical installations including testing & commissioning etc. complete as per direction of Engineer in Charge. |
| 51 | Step up modular regulator for Fan |
| 52 | 15watt LED Bulb. |
| 53 | 1200mm Ceiling Fan (Havells/ Bajaj/Usha/ Equivalent make with approval of the authority) |
| 54 | Electric 200mm Exhaust Fan (Havells/ Bajaj/Usha/ Equivalent make with approval of the authority) |
| 55 | Electric 150mm Exhaust Fan (Havells/ Bajaj/Usha/ Equivalent make with approval of the authority) Ventil air DX white |
| 56 | Titanio Pro LED Tube Light -18W (Double side connection) |
| 57 | 32A Double Pole MCB. |
| 58 | 5 Amp switch |
| 59 | 5 Amp socket |
| 60 | Ceiling Rose - |
| 61 | Angle Holder |
| 62 | Supplying, fitting and fixing of 15 Amp plug point with line connection and testing charges.. |
| 63 | Supply, Installation, Testing Wiring & Commissioning of Lighting Distribution Panel Made out of 2MM C.R sheet, Duely Powder coated, Floor mounted, Front operated, complete with Rated Alluminium BusBar and interconnection with copper wire and lugs. Having 63A 4P MCB-1 Nos,32A FP MCB-2 Nos, 32A DP MCB-1 Nos, 16A DP MCB- 3Nos, 10A DP MCB-1Nos, All switchgear and controlgear make- Siemens,schneider,ABB,Lauritz Knudsen,LEGRAND. All completed as per electrical specification and as per direction of EIC. |
| 64 | Supplying fitting & fixing of Single arm Bracket of 1.0 mtr length suitable for fixing in 70mm top yard lighting octagonal smart pole |
| 65 | Cable junction boxes IP66/69 weather proof for outdoor installation of size 104mm x 104mm x 70 mm (with knockouts for cable entry - Black colour) |
| 66 | Connector suitable for 4sqmm For yard lighting |
| 67 | 2.50 Sqmm 4 core copper armoured Cable including laying (Make:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 68 | Supply fitting & fixing of energy saving & envoirnmental friendly long life pressure die cast housing with toughened glass & with option of secondary optic with IP66 protection 45 Wt LED light . |
| 69 | Supply, Installation of Control Desk -1 no., Table - 1 no. & Chairs - 2 nos. at Control Room and completed as per Ingineering-In-Charge. |
| 70 | Supplying all materials,labour and T&P and constructing RCC Valve chamber for housing sluce valve,flow meter,selenoid control valve as per P.H. specification and design all complete including RCC Cover Slab(per each) DMA control chamber internal size:-[5.0x2.0x1.45mtr] . |
| 71 | Supplying all labour, T&P and earth work in excavation in all kinds of soil in pipe trenchs etc including dressing and levelling the bed and depositing the soil within 50M initial lead and 1.5M initial lift, as per the direction of the Engineer-in-charge. |
| 72 | Filling F&P with sand welwatered rammed etc complete |
| 73 | Providing cement concrete (1:3:6) with 40mm size HG metal including cost of all materials, labour T & P etc. all complete as per specification & direction of Engineer-in-charge. |
| 74 | For Reconstruction of RCC MHC - |
| 75 | Rigid smooth centring and shuttering for R.C.C. works and dismantling then after casting including cost of materials,labour & T & P etc. all complete. |
| 76 | R.C.C. Foundation, Plinth Band, Footings, Bases of Columns, Mass Concrete & Precast Slabs etc. in Ground Floor. |
| 77 | R.C.C. Walls |
| 78 | Cement concrete (1:11/2:3) with 12mm.size crusher broken hard Granite chips for R.C.C.work including hoisting & laying with cost of all labour, materials with all taxes, lead ,T & P etc all complete . |
| 79 | RCC Man Hole Chamber of 1.20 mtr dia |
| 80 | M.S. Reinforcement for R.C.C. works including cutting,bending, binding and tying grills and placing in position including cost of M.S.Rods,binding wire 18 to 20 gauge. |
| 81 | 12mm thick cement plaster (1:4) to inside surface including all materials labour & T & P etc. complete as per direction of Engineer in charge. |
| 82 | Filling foundation and plinth with excavated materials including watering and ramming as per specification & direction of Engineer-in-charge. |
| 83 | Supplying fitting & fixing of S.F.R. poly popylene foot step iron |
| 84 | Supplying all materials, labour and T&P for Transportation of excavated material & disposing upto 5KM from work site including loading, unloading & stacking, supplying of all labours, tools & plants etc. all complete as per specification and direction of Engineer-in-charge. |
| 85 | Supplying all materials Labour & T & P for providing & fixing of Heavy duty precast Factory made RCC Cover slab in two pieces with frame to hold the cover made out of M 30 concrete with making hole to operate valves without removing cover slab .The cover slab & frame should be enough strength to withstand against heavy vehicular movement up to 20 MT load of following size of Sluice valve chambers including.The HD 20 cover slab with frame should be fixed in such a manner with provision to stop entry of storm water in to chamber etc complete as per actual site condition & direction of Engineer in charge. |
| 86 | Providing cement concrete (1:2:4) with 20mm size HG chips including cost of all materials, labour T & P etc. all complete as per specification & direction of Engineer-in-charge. |
| 87 | Cost towards HD 20 factory made precast RCC cover slab of outer size 765 mm x 765mm of 90mm thick with factory made precast RCC frame of outer size 1065mm x 1065mm of 150mm thick with groove cutting suitable to hold 90mm thick cover slab. |
| 88 | Laying of Distrbution pipe lines ,Installation of Valves,Interconnection work, wash out arrangements & SV Chamber etc (Proposed:50999m) |
| 89 | Supply & Laying Centrifugally Cast (Spun) Ductile Iron pressure, socket and spigot pipes Class K7 without cement mortar lining conforming to IS:8329 - 2000 of the following nominal diameter as per specification complete. (Earthwork in trenches, jointing of pipes, specials and fittings to be measured and paid for separately)(including cost of D.I.K-7 pipe & Tyton Rubber Ring) |
| 90 | DI-K7 |
| 91 | 100mm dia DI (K7) |
| 92 | 150mm dia DI (K7) |
| 93 | 200mm dia DI (K7) |
| 94 | 250mm dia DI (K7) |
| 95 | 300mm dia DI (K7) |
| 96 | 350mm dia DI (K7) |
| 97 | 400mm dia DI (K7) |
| 98 | 450mm dia DI (K7) |
| 99 | Cutting asphalt or bituminous road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 100 | Cutting WBM/Metal road of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 101 | Cutting concrete road of grannualar course of flexible pavments and disposal of dismantalled materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 102 | Dismantalling of Pavor block materials up a lead of 1000 mtr stacking servicable and unservicable materials separately including cost of all labour, T & P etc. all complete as per the direction of engineer-in-charge. |
| 103 | Supplying all labour, T&P for earth work excavation in trenches in following kinds of soil within initial lead of 50m & initial lift of 1.50m including rough fressing breaking clods and laying in layers not exceeding 0.30m. In depth, levelling the bed, using pans, vessels for slushy soil and including sundries supervision charges &labour cess etc, as per direction of Engineer-in-charge |
| 104 | In all kinds of soil |
| 105 | Disintegrated rock not required blasting |
| 106 | Supplying & laying inside trenches Ductile Iron fittings & Specials of following sizes confirming to IS Specification etc all complete as per direction of Engineer-in-charge. |
| 107 | For 100mm to 450mm dia |
| 108 | Taking 5% of pipe weight |
| 109 | 350 to 450 mm dia DI (K7) |
| 110 | Taking 5% of pipe weight |
| 111 | Providing push-on-joints conforming to IS:3114-1994 to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes using Rubber Gaskets Conforming to I.S 5382 of S.B.R quality including testing of joints as per specification complete . (Labour Only) |
| 112 | 100mm diameter |
| 113 | 150mm diameter |
| 114 | 200mm diameter |
| 115 | 250mm diameter |
| 116 | 300mm diameter |
| 117 | 350mm dia |
| 118 | 400mm dia |
| 119 | 450mm dia |
| 120 | Supply fitting & Fixing cast iron DI resilient seated Sluice Valve of RATING PN - 1.60(IS 14846/2000) with double flanged ends (with wheel) for water works purpose for the following rating & nominal diameters but (including cost of Sluice Valves) Make- (VAG/ Talis/ AVK/IVC/ Kirloskar/Hawle/Equivalent make with approval of the authority) |
| 121 | 100mm dia |
| 122 | 150mm dia |
| 123 | 200mm dia |
| 124 | 250mm dia |
| 125 | 300mm dia |
| 126 | 350mm dia |
| 127 | 400mm dia |
| 128 | 450mm dia |
| 129 | Supplying all materials,labour and T&P and constructing brick masonry chamber as per P.H. specification and design all complete including HD-20 Cover Slab (per each) |
| 130 | S.V. chamber internal size:-[0.75x0.75x1.2250mtr] for 80mm dia to150mm dia S/V. |
| 131 | S.V. chamber internal size:-[1.0x1.0x1.50mtr] for 200mm. to 450mm .dia. S/V. |
| 132 | Supplying all labour and T&P for providing and laying MS pipe and specials confirming to IS 3589/99 of quality grade FE 410/ GI Pipe (Medium ) confirming to specification of following nominal dia and including transportation of pipes and fitting to site etc all complete as per the direction of E.I.C. |
| 133 | 100mm dia M.S.Pipe (4.50mm thick) |
| 134 | 100mm dia M.S. Flange.(10mm thick) |
| 135 | 100mm dia x 45' M.S Bend/Offset Bend |
| 136 | 100mm dia x 90' M.S. Bend/Offset Bend |
| 137 | 150mm dia M.S.Pipe (4.50mm thick) |
| 138 | 150mm dia M.S. Flange.(12mm thick) |
| 139 | 150mm dia x 45' M.S. Bend/Offset Bend |
| 140 | 150mm dia /90' M.S. Bend/Offset Bend |
| 141 | 200mm dia M.S.Pipe (6.30mm thick) |
| 142 | 200mm dia M.S. Flange.(12mm thick) |
| 143 | 200mm dia 45⁰ M.S Bendd/Offset Bend |
| 144 | 200mm dia 90' M.S. Bend/Offset Bend |
| 145 | 250mm dia M.S.Pipe(6.30mm thick) |
| 146 | 250mm dia M.S. Flange. |
| 147 | 250mm dia 45⁰ M.S BendOffset Bend |
| 148 | 250mm dia 90' M.S. Bend/Offset Bend |
| 149 | 300mm dia M.S.Pipe(6.40mm thick) |
| 150 | 300mm dia M.S. Flange. |
| 151 | 300mm dia 45⁰ M.S BendOffset Bend |
| 152 | 300mm dia 90' M.S. Bend/Offset Bend |
| 153 | 350mm dia M.S.Pipe (8mm thick) |
| 154 | 350mm dia M.S. Flange.(16mm thick) |
| 155 | 350mm dia x 45' M.S. Bend |
| 156 | 350mm dia x 90' M.S. Bend |
| 157 | 400mm dia M.S.Pipe (8.80mm thick) |
| 158 | 400mm dia M.S. Flange.(12mm thick) |
| 159 | 400mm dia x 45' M.S. Bend |
| 160 | 400mm dia x 90' M.S. Bend |
| 161 | 450mm dia M.S.Pipe (7.92mm thick) |
| 162 | 450mm dia M.S. Flange.(16mm thick) |
| 163 | 450mm dia x 45' M.S. Bend |
| 164 | 450mm dia x 90' M.S. Bend |
| 165 | 500mm dia M.S.Pipe (7.92mm thick) |
| 166 | 500mm dia M.S. Flange.(16mm thick) |
| 167 | 500mm dia x 45' M.S. Bend |
| 168 | 500mm dia x 90' M.S. Bend |
| 169 | 600mm dia M.S.Pipe (8.00mm thick) |
| 170 | 600mm dia M.S. Flange.(16mm thick) |
| 171 | 600mm dia x 45' M.S. Bend |
| 172 | 600mm dia x 90' M.S. Bend |
| 173 | Flame cutting and facing of MS plate or pipes upto 8mm thick including supply of all labor, material, tools & plants for all complete as per specification and direction of Engineer-in-Charge. |
| 174 | Supplying all labour and T&P for Welding with two welding beads/pass, conforming to IS:816-1998 (Fillet weld) to MS pipes and fittings at site. |
| 175 | Supplying all materials,labour and T&P and making flanged joints for C.I. pipes and specials of the following diameter including testing of joints as per specification all complete. |
| 176 | 100mm dia Flange joints |
| 177 | 150mm dia Flange joints |
| 178 | 200mm dia Flange joints |
| 179 | 250mm dia Flange joints |
| 180 | 300mm dia Flange joints |
| 181 | 350mm dia Flange joints |
| 182 | 400mm dia Flange joints |
| 183 | 450mm dia Flange joints |
| 184 | 500mm dia Flange joints |
| 185 | 600mm dia Flange joints |
| 186 | Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge. |
| 187 | Backfilling in Pipe trenches- |
| 188 | Filling in foundatin and plinth with sand watered and rammed including cost of sand & labour. |
| 189 | Supplying all materials, labour, T&P and providing cement concrete(1:3:6) with 12mm size crusher broken hard granite chips including all cost of conveyance, royalty, sundries, watering for curing, supervision charge, contractor profit & labour cess etc. all complete as p[er the direction of Engineer-in-charge. |
| 190 | Supplying all materials, labour, T&P and providing cement concrete(1:2:4) with 12mm size crusher broken hard granite chips including all cost of conveyance, royalty, sundries, watering for curing, supervision charge, contractor profit & labour cess etc. all complete as p[er the direction of Engineer-in-charge. |
| 191 | Re-Fixing of dismantalled precast cement concrete interlocking paving blocks of all sizes over 50 mm thick course sand bedding (duly compacted) including filling of joints with sand complete in all respect. |
| 192 | Taking 70% of total area |
| 193 | Providing Supplying, fitting and fixing of 80mm thick interlock concrete colour paver block on compacted river coarse sand free from all organic materials and filling the joints with sand. including cutting corbelling, splays where ever necessary to proper size with cost, conveyance, royalties and taxes of all materials and cost of all labour, etc. complete in all respect as directed by Engineer in charge. |
| 194 | Taking 30% of total area |
| 195 | Supplying all materials, labour, and T&P for BT road Construction of granular sub-base by providing the materials with 100% crushed stone aggregates confirming to grade-I of coarse garded GSB material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. |
| 196 | Supplying all materials, labour, and T&P for BT road of Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. |
| 197 | Supplying all materials, labour, and T&P for BT road of Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means. |
| 198 | Supplying all materials, labour, and T&P for BT road of Providing and laying dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 507 complete in all respects. |
| 199 | Supplying all materials, labour, and T&P for BT road of Providing, laying and rolling of close-graded premix surfacing material of 25 mm thickness composed of 11.2 mm to 0.09 mm (Type-a) or 13.2 mm to 0.09 mm (Type-b) aggregates using penetration grade bitumen to the required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to required level and grade. |
| 200 | Supplying all materials, labour, and T&P for removal/carriage of excavated earth from site to a distance 5 km away etc all complete and as per the specifications and directions of engineer-in-charge. |
| 201 | Supplying all materials Labour & T&P for Interconnection comlpeted as per specification and Engineering_In-Charge. |
| 202 | 100mm dia DI (K7) |
| 203 | 150mm dia DI (K7) |
| 204 | 200mm dia DI (K7) |
| 205 | 250mm dia DI (K7) |
| 206 | 300mm dia DI (K7) |
| 207 | 350mm dia DI (K7) |
| 208 | Providing, fixing of CI Mechanical Joint Socket confirming to IS: 13382/ 92 to flanged ends of Cast Iron pipes or Ductile iron pipes of the following nominal diameter including testing of joints. |
| 209 | 100mm dia |
| 210 | 150mm dia |
| 211 | 200mm dia |
| 212 | 250mm dia |
| 213 | 300mm dia |
| 214 | 350mm dia |
| 215 | 400mm dia |
| 216 | 450mm dia |
| 217 | Bailing out water during earth work in all soils from the pipe line trenches using suitable pump and motor withabour charges and other incidental and operational charges etc., as per directions of engineer in charge |
| 218 | Automation & Instrumentation work ( PLC, Flow meter, Control valve ,Pressure transmeter, Level controller,Data transmission system etc)-Distribution |
| 219 | Supply and installation of MS pipe including required numbers of bends and flanges and dismentaling joint etc required for installation of DMA control units (i.e- Globe valve, flow meter, PG, PT etc.) and fiber cover over the arrangement fixing on CC(1:3:6) platform including cost of all materials, labour for fitting and fixing etc. all complete.as per site requirement and as per the direction of the engineer in charge.( excluding cost of Sluice valve, flow meter, PG, PT.) |
| 220 | Loading Line |
| 221 | 150 mm(DMA_08, DMA-13, DMA -16, OLD MRDICAL,STADIUM,AIRPORT,BLACK DIAMOND COLLEGE,NEW MEDICAL,GOVT. COLLEGE,ENG. COLLEGE,JAIL |
| 222 | 200 mm (DMA_05, DMA-06,DMA -12, DMA -14) |
| 223 | 250 mm(DMA_03, DMA-09) |
| 224 | 300 mm(DMA_01, DMA-02,DMA -04, DMA -07,DMA_10& 15,DMA -11) |
| 225 | Distribution Line(Sub DMA) |
| 226 | 150 mm(Sub DMA 15C, OLD MRDICAL,STADIUM,AIRPORT,BLACK DIAMOND COLLEGE,NEW MEDICAL,GOVT. COLLEGE,ENG. COLLEGE,JAIL ) |
| 227 | 200 mm(Sub DMA 3A, Sub DMA 3C,Sub DMA 4A,Sub DMA 4B,Sub DMA 5A,Sub DMA 6A,Sub DMA 7C,Sub DMA 8A,Sub DMA 15A,Sub DMA 11C,Sub DMA 13A,Sub DMA 14A,Sub DMA 16A,Sub DMA 16B) |
| 228 | 250 mm(Sub DMA 2A, Sub DMA 3B,Sub DMA 4C,Sub DMA 5B,Sub DMA 5C,Sub DMA 7B,Sub DMA 9A,Sub DMA 9C,Sub DMA 9B,Sub DMA 10C,Sub DMA 15B,Sub DMA 13B,Sub DMA 14B) |
| 229 | 300 mm(Sub DMA 1B, Sub DMA 2B,Sub DMA 2C,Sub DMA 6B,Sub DMA 8B,Sub DMA 10A,Sub DMA 11A) |
| 230 | 350 mm(Sub DMA 11D ) |
| 231 | 400mm(Sub DMA 4D,Sub DMA 7D, Sub DMA 10B, Sub DMA 11B, Sub DMA 12B ) |
| 232 | 450 mm(Sub DMA 12A,Sub DMA 12C ) |
| 233 | 500mm(Sub DMA 1A,Sub DMA 7A) |
| 234 | CONTROL ROOM PLC for ESR OPERATION: Supply all material, labour T&P for installation & testing commissioning of PLC System of appropriate capacity & sufficient provision of digital & analog input and output to rum the plant & machineries within the campus limit, with minimum 20% spare cards, being operated locally at ESR campus, with provision of PLC operation (On & Off) of feed pump with respective Chlorine analyzer with an architecture of maintaining water quality in distribution pipeline at identified location. Complete operation of the feed pump depends upon the water quality communicated via point to point(P2P) signal from the remote analyzer unit to main PLC. Provision should be there for LIVE data communication (by agency) between the PLC panels through FO Cable for the operation (on & off) of clear water Well Pumps as per the water requirement at MBR. Local data storing facility should be there and for monitoring and analysis as per the user needs and report generation. (The Cost is inclusive of cost of materials, installation & successful commissioning etc) The PLC & all necessaries shall be of high standard make. (Make:- Siemens,Schnider,ABB,Mitsubishi/Equivalent make with approval of authority)(DMA -01,03,04,05,06,07,08,09.11,12,13, 15,16) |
| 235 | Supply,Installation & Commissioning of SCADA software (Make-Schiender/Simens/Rockwell/Equivalent make with approval of authority) and cost for development of 24x7 distribution management system software, with Graphical processor visualisation Advanced alarm management, historical and Real time trending, Built-in-reporting, Stastical process control, Multithreaded citect VBA and Cicode programming language including installations of Desk top PC, Modem for receiving data etc all complete(DMA -01,03,04,05,06,07,08,09.11,12,13, 15,16). |
| 236 | RTU system shall have been neatly wired insidewall/polemounted CRCA powdercoated suitable for outdoor mounnting.RTUsystem shall be protected from all possible surges and must have required surge protection deices.RTU must be fully programmable asper IEC61131-3 and it shall have MQTT or DNP3 built-in protocol support,RTUIO count shall have DI-8,DO-4,AI-4,RTU shall have capability of reading fast digital pulses from flowmeters. Ambient working temperature shall be 55 deg C for RTU & othercomponents.System shall work under relative humidity upto 95% (Non-condensing).All required networking accessories mustbe included in the RTU system for LIVE data communication between the RTU panel and existing Linux kernel supported NIC Server viaOFC.The data should be stored through an application in the server for monitoring and analysis of entire water network from various remote places.Incase of OFC breakage,all data shall be recovered upon restoring of OFC.Approved make: RTU-Schneider/Siemens, SPD-Dehn/Mersen Media Converter-Syrotech/Dlink/TP-Link Panel-Rittal/AEC/Werner Approved system provider: DynamicTechnologies/AutomatechElectricCo/VisnaveAutomation(DMA-15&10) |
| 237 | Installation, testing & commissioning for the RTU system at lane level, including cost of all labour, T&P etc., all complet(DMA-10&15) |
| 238 | Supply, Installation and commissioning of single phase 1KVA online UPS with pure sine wave & float cum boost charging with battery rack and maintenance free battery system including cables power plug, switch having application in 24V lot DC Battery (drytype) charging to output continuous 3 hrs power backup all Complete Works. |
| 239 | Supply, Installation and commissioning of Control cables to be inserted in conduit pipe in trenches, cables to be laid in racks, cleated on walls, cable lugs, cables glands, conduits, cablejoints etc. as per specification. all Complete Works Screened cable unarmoured. (Make:-Finolex/Lauritz Knudsen /Anchor/ Havells /V Guard/Equivalent make with approval of the authority) |
| 240 | 1.5 sqmm 4 C CU AR Shielded Cable |
| 241 | 1.5 sqmm 2 CU AR Shielded Cable |
| 242 | Instrument Cable- 2 Pair 1.5 mm2 cable |
| 243 | Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure,manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading indifferent units (Kiloliters / Cubicmeter)and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3m/sec to 4m/sec and be constructed as follows: Meter tube(Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/Poly urethrene/PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity,hysteresis, repeatability, temperature and pressure effects.Coil Housing shall be fabricated from stainless steel (SS304) /Die cast Aluminium/Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing.The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions.The converter shall provide an isolated 4-20mA out put into minimum 500-ohm load and a frequency output of a maximum of 0-10KHZ and a scaled pulse output.The micro processor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a prograable low flowdrop out, higher flowand empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully prograable from the front facia. The programing should be user friendly,self-prompting menu driven.Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. (Make- KROHNE MARSHALL/E&H/ABB/SIEMENS/Equivalent make with approval of authority) |
| 244 | Loading Line |
| 245 | 150 mm(DMA_08, DMA-13, DMA -16, OLD MRDICAL,STADIUM,AIRPORT,BLACK DIAMOND COLLEGE,NEW MEDICAL,GOVT. COLLEGE,ENG. COLLEGE,JAIL |
| 246 | 200 mm (DMA_05, DMA-06,DMA -12, DMA -14) |
| 247 | 250 mm(DMA_03, DMA-09) |
| 248 | 300 mm(DMA_01, DMA-02,DMA -04, DMA -07,DMA_10& 15,DMA -11) |
| 249 | Distribution Line(Sub DMA) |
| 250 | 150 mm(Sub DMA 15C ) |
| 251 | 200 mm(Sub DMA 3A, Sub DMA 3C,Sub DMA 4A,Sub DMA 4B,Sub DMA 5A,Sub DMA 6A,Sub DMA 7C,Sub DMA 8A,Sub DMA 15A,Sub DMA 11C,Sub DMA 13A,Sub DMA 14A,Sub DMA 16A,Sub DMA 16B) |
| 252 | 250 mm(Sub DMA 2A, Sub DMA 3B,Sub DMA 4C,Sub DMA 5B,Sub DMA 5C,Sub DMA 7B,Sub DMA 9A,Sub DMA 9C,Sub DMA 9B,Sub DMA 10C,Sub DMA 15B,Sub DMA 13B,Sub DMA 14B) |
| 253 | 300 mm(Sub DMA 1B, Sub DMA 2B,Sub DMA 2C,Sub DMA 6B,Sub DMA 8B,Sub DMA 10A,Sub DMA 11A) |
| 254 | 350 mm(Sub DMA 11D ) |
| 255 | 400mm(Sub DMA 4D,Sub DMA 7D, Sub DMA 10B, Sub DMA 11B, Sub DMA 12B ) |
| 256 | 450 mm(Sub DMA 12A,Sub DMA 12C ) |
| 257 | 500mm(Sub DMA 1A,Sub DMA 7A) |
| 258 | Supplying, Fitting,fixing & Commissioning,of double chamber DI control valve of PN 1.6 ,hydraulic operated 24 V DC, selonoid control,IP68, shall be integrated with RTU pannel for operation (local/remote and web enabled with command and control) to control water supply including the cost of valve cutting the pipeline & making good to the damages including cost of all labours, T&P etc. all complete as per the direction of Engineer-in-charge.Electric Operated Selonoid Valve Pilot Actuated. Make- (VAG/ Talis/ AVK/IVC/ Kirloskar/Hawle/Equivalent make with approval of the authority) |
| 259 | Loading Line |
| 260 | 150 mm(DMA_08, DMA-13, DMA -16, OLD MRDICAL,STADIUM,AIRPORT,BLACK DIAMOND COLLEGE,NEW MEDICAL,GOVT. COLLEGE,ENG. COLLEGE,JAIL |
| 261 | 200 mm (DMA_05, DMA-06,DMA -12, DMA -14) |
| 262 | 250 mm(DMA_03, DMA-09) |
| 263 | 300 mm(DMA_01, DMA-02,DMA -04, DMA -07,DMA_10& 15,DMA -11) |
| 264 | Distribution Line(Sub DMA) |
| 265 | 150 mm(Sub DMA 15C ) |
| 266 | 200 mm(Sub DMA 3A, Sub DMA 3C,Sub DMA 4A,Sub DMA 4B,Sub DMA 5A,Sub DMA 6A,Sub DMA 7C,Sub DMA 8A,Sub DMA 15A,Sub DMA 11C,Sub DMA 13A,Sub DMA 14A,Sub DMA 16A,Sub DMA 16B) |
| 267 | 250 mm(Sub DMA 2A, Sub DMA 3B,Sub DMA 4C,Sub DMA 5B,Sub DMA 5C,Sub DMA 7B,Sub DMA 9A,Sub DMA 9C,Sub DMA 9B,Sub DMA 10C,Sub DMA 15B,Sub DMA 13B,Sub DMA 14B) |
| 268 | 300 mm(Sub DMA 1B, Sub DMA 2B,Sub DMA 2C,Sub DMA 6B,Sub DMA 8B,Sub DMA 10A,Sub DMA 11A) |
| 269 | 350 mm(Sub DMA 11D ) |
| 270 | 400mm(Sub DMA 4D,Sub DMA 7D, Sub DMA 10B, Sub DMA 11B, Sub DMA 12B ) |
| 271 | 450 mm(Sub DMA 12A,Sub DMA 12C ) |
| 272 | 500mm(Sub DMA 1A,Sub DMA 7A) |
| 273 | Providing, installation, testing and commissioning of Diaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass, Over range protection: 125% of maximum pressure, Material of sensor and other wetted parts: SS type 316, Housing material: Die cast aluminum with linear scale |
| 274 | Loading Line |
| 275 | 150 mm(DMA_08, DMA-13, DMA -16, OLD MRDICAL,STADIUM,AIRPORT,BLACK DIAMOND COLLEGE,NEW MEDICAL,GOVT. COLLEGE,ENG. COLLEGE,JAIL |
| 276 | 200 mm (DMA_05, DMA-06,DMA -12, DMA -14) |
| 277 | 250 mm(DMA_03, DMA-09) |
| 278 | 300 mm(DMA_01, DMA-02,DMA -04, DMA -07,DMA_10& 15,DMA -11) |
| 279 | Distribution Line(Sub DMA) |
| 280 | 150 mm(Sub DMA 15C ) |
| 281 | 200 mm(Sub DMA 3A, Sub DMA 3C,Sub DMA 4A,Sub DMA 4B,Sub DMA 5A,Sub DMA 6A,Sub DMA 7C,Sub DMA 8A,Sub DMA 15A,Sub DMA 11C,Sub DMA 13A,Sub DMA 14A,Sub DMA 16A,Sub DMA 16B) |
| 282 | 250 mm(Sub DMA 2A, Sub DMA 3B,Sub DMA 4C,Sub DMA 5B,Sub DMA 5C,Sub DMA 7B,Sub DMA 9A,Sub DMA 9C,Sub DMA 9B,Sub DMA 10C,Sub DMA 15B,Sub DMA 13B,Sub DMA 14B) |
| 283 | 300 mm(Sub DMA 1B, Sub DMA 2B,Sub DMA 2C,Sub DMA 6B,Sub DMA 8B,Sub DMA 10A,Sub DMA 11A) |
| 284 | 350 mm(Sub DMA 11D ) |
| 285 | 400mm(Sub DMA 4D,Sub DMA 7D, Sub DMA 10B, Sub DMA 11B, Sub DMA 12B ) |
| 286 | 450 mm(Sub DMA 12A,Sub DMA 12C ) |
| 287 | 500mm(Sub DMA 1A,Sub DMA 7A) |
| 288 | Supply of Pressure transmitter to be installed for delivery main with following technical specification. i.e. Range up to 10 kg/cm2.Type-Sensor.Power Supply-24 DC. Output-4 to 20mA.(Make-E & H/ABB/VEGA/WIKA/Equivalent make with approval of authority) |
| 289 | Loading Line |
| 290 | 150 mm(DMA_08, DMA-13, DMA -16) |
| 291 | 200 mm (DMA_05, DMA-06,DMA -12, DMA -14) |
| 292 | 250 mm(DMA_03, DMA-09) |
| 293 | 300 mm(DMA_01, DMA-02,DMA -04, DMA -07,DMA_10& 15,DMA -11) |
| 294 | Distribution Line(Sub DMA) |
| 295 | 150 mm(Sub DMA 15C ) |
| 296 | 200 mm(Sub DMA 3A, Sub DMA 3C,Sub DMA 4A,Sub DMA 4B,Sub DMA 5A,Sub DMA 6A,Sub DMA 7C,Sub DMA 8A,Sub DMA 15A,Sub DMA 11C,Sub DMA 13A,Sub DMA 14A,Sub DMA 16A,Sub DMA 16B) |
| 297 | 250 mm(Sub DMA 2A, Sub DMA 3B,Sub DMA 4C,Sub DMA 5B,Sub DMA 5C,Sub DMA 7B,Sub DMA 9A,Sub DMA 9C,Sub DMA 9B,Sub DMA 10C,Sub DMA 15B,Sub DMA 13B,Sub DMA 14B) |
| 298 | 300 mm(Sub DMA 1B, Sub DMA 2B,Sub DMA 2C,Sub DMA 6B,Sub DMA 8B,Sub DMA 10A,Sub DMA 11A) |
| 299 | 350 mm(Sub DMA 11D ) |
| 300 | 400mm(Sub DMA 4D,Sub DMA 7D, Sub DMA 10B, Sub DMA 11B, Sub DMA 12B ) |
| 301 | 450 mm(Sub DMA 12A,Sub DMA 12C ) |
| 302 | 500mm(Sub DMA 1A,Sub DMA 7A) |
| 303 | Supplying all materials Labour & T&P for Fixing of DI tamper proof Kinatic Air Valve P.N 1.0 for water works purposes conforming to IS specification for the following nominal diameters as per specification complete including cost of Air valve and isolation valve. (Make -VAG/ Talis/ AVK/IVC/ Kirloskar/Hawle/Equivalent make with approval of the authority) |
| 304 | Loading Line |
| 305 | 150 mm(DMA_08, DMA-13, DMA -16, OLD MRDICAL,STADIUM,AIRPORT,BLACK DIAMOND COLLEGE,NEW MEDICAL,GOVT. COLLEGE,ENG. COLLEGE,JAIL |
| 306 | 200 mm (DMA_05, DMA-06,DMA -12, DMA -14) |
| 307 | 250 mm(DMA_03, DMA-09) |
| 308 | 300 mm(DMA_01, DMA-02,DMA -04, DMA -07,DMA_10& 15,DMA -11) |
| 309 | Distribution Line(Sub DMA) |
| 310 | 150 mm(Sub DMA 15C ) |
| 311 | 200 mm(Sub DMA 3A, Sub DMA 3C,Sub DMA 4A,Sub DMA 4B,Sub DMA 5A,Sub DMA 6A,Sub DMA 7C,Sub DMA 8A,Sub DMA 15A,Sub DMA 11C,Sub DMA 13A,Sub DMA 14A,Sub DMA 16A,Sub DMA 16B) |
| 312 | 250 mm(Sub DMA 2A, Sub DMA 3B,Sub DMA 4C,Sub DMA 5B,Sub DMA 5C,Sub DMA 7B,Sub DMA 9A,Sub DMA 9C,Sub DMA 9B,Sub DMA 10C,Sub DMA 15B,Sub DMA 13B,Sub DMA 14B) |
| 313 | 300 mm(Sub DMA 1B, Sub DMA 2B,Sub DMA 2C,Sub DMA 6B,Sub DMA 8B,Sub DMA 10A,Sub DMA 11A) |
| 314 | 350 mm(Sub DMA 11D ) |
| 315 | 400mm(Sub DMA 4D,Sub DMA 7D, Sub DMA 10B, Sub DMA 11B, Sub DMA 12B ) |
| 316 | 450 mm(Sub DMA 12A,Sub DMA 12C ) |
| 317 | 500mm(Sub DMA 1A,Sub DMA 7A) |
| 318 | Supply,Installation ,testing & commissioning of WATER Quality Moniter for Residual Chlorine in DistributinNetwork, the Input Power Supply should be internal battery (2 of LSH 20 3.6V High Discharge Lithium Battery withCommunication and Data Logging through GPRS Modem, Website, RS232 link to PC,RS232 link to Bluetooth dongle to mobile Device ,Storageof upto 55000 data points in the device and having Electrical Connections 1X 9Way Fischer Socket Yellow (102)Style for RS 232/Bluetooth dongle, 1X 5Way Fischer Socket (103)Style for Chlorine Sensor, 1X 9Way Fischer Socket red (102)Style for External Device, 1X 7Way Fischer Socket Grey (102)Style for External Device having Environmental protection 1P68 to 1m the analyser is designed to fit within Standard Hydrant Chamber with Minimum of 300mm between the Hydrant outlet to the underside of the Chamber lid-150mm(w) x 164mm(h) Weight including laying of connecting uPVC pipe Sch-80 & power supply arrangements etc. complete as per requirement & direction of Engineer in Charge. (ABB/E&H/Forbes Marshall/Equivalent make with approval of the authority)- |
| 319 | Supply & installation of Turbidity at filter house for online monitoring of turbidity in clear water with following technical specification i.e sensor type-Optical nephelometer turbidity and suspended solids sensor,sensor rating-IP68,Range-0 to 4000 NTU,Accuracy 2% measured valyue,Display resolution -0.001 NTU,operating pressure up to 10 bar (145psi),power 100 mA@24V DC (ABB/E&H/Forbes Marshall/Equivalent make with approval of the authority)- At WTP |
| 320 | Supply & installation testing with technical specification pH Sensor (DPC1R1A)Accuracy: Less than 0.1 pH under reference conditions Body Material: PPS,Electrode Material: General Purpose Glass pH Electrode,Flow: 0 2 m/s (0 - 6.6 ft./s); non-abrasive operating temperature range: 0 - 105 °C,Pressure Range: 0 - 6.9 bar at 100ºC (0 - 100 psig at 212ºF)Range: Combination pH Sensors 0 - 14 pH,Sensor Cable: Integral coaxial cable (plus two conductors for temperature compensator option); 4.5 m (15 ft.) long Sensor Thread: 0.75\\",Temperature Compensation: Pt 1000 ohm RTD Includes: sensor with 15 ft cable, digital gateway, 3 ft digital extension cable and manual(ABB/E&H/Forbes Marshall/Equivalent make with approval of the authority)At Brajaraj nagar WTP & DMA 8 nos |
| 321 | Designing, Supplying, Installing, commissioning & testing of Ultrasonic level transmitter CE marked with following technical parameters Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext.,Display - 4\\" LED ,Range- 0-10 mtr - 20 mtr.,Accuracy - +/- 0.25% of Full Scale or better ,Enclosure- IP 68 ,Mounting - On PLC panel at ESR/UGR and all complete as per the direction of Engineer-in-charge. (Make-E & H/ABB/VEGA/WIKA/Equivalent make with approval of authority) |
| 322 | Supply, Installation, Testing and commissioning of Chlorine Dosing machine incluiding laying of pvc pipe interconnection with main waterline, Chemical storage and handling equipment etc. 0-500 Lph Zeroleakge pneumatic diapharm dosing pump - 2nos, one primary and one standby mode, pressure upto-10bar, 1000 Ltr Chemical tank capacity. Agitator motor - 1nos, strainer, NRV on Pump Outlet, Electrically actute Flow control Valve with PLC compatible VFD Panel for dosing pump and agitator etc. transportation & packaging including cost of materials, all labours, T&P etc. all complete as per the direction of Engineer-in-charge. |
| 323 | Communication data transmission |
| 324 | HDPE PIPE: Supply and Laying of 40MM dia HDPE pipe in cable trench or buried as per specification and directions of Site Engineer / Engineer-in-Charge. |
| 325 | OFC: Supply and Laying of 12core unarmoured Optical fibre cable (OFC :fiber glass with F-G 62.5/125micron, 2.6DB/KM F600) to various sites through HDPE pipe, prelaying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through previously laid HDPE, jointing / splicing of OFC, post installation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ SiteEngineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer. |
| 326 | 4G Dual Sim LTE Router with 1 X LAN, 1 X WAN, RS485 on board with one at a time usage, WI-FI (802.11 b / g / n), 1 X Cellular Antenna, 1 X WIFI Antenna, Model- SW245 (RS485) |
| 327 | Supply and Installation of OFC jointing kits including LIU as per drawings, specifications anddirections of Engineer-in-charge/Site Engineer. |
| 328 | Supply and laying of pre-cast RCC Joint Box 600mm dia, depth 600 with Iid as per specification and directions of Site Engineer / Engineer-in Charge. |
| 329 | Earthing: Providing Electrical system system's earthing as per latest IS 3043, and the work shall include the following: Earthing electrodes comprising of GI pipe 40mm dia 2.9 mm thick 2.5 mtrs long with mesh covered funnel. Digging 300mm dia earthing pits to suitable depth for buring the main electrodes in the pit. The pit shall be filled with alternate layers of salt and charcoal 150mm thick around the pipe to the entire depth. An inspection chamber of 300x300x300mm size shall be constructed with CC 1:3:6 prop. The chamber shall be provided with CI/MS cover hinged to the frame. The Electrical Metering & switching , encloser electrical equipment shall be connected to the earth pit through 4 Sqmm Cu (green) for equipment/PLC earthiing. |
| 330 | Provision for new House connection including fixing of Saddle , compression fittings & Replacement of house connection,fixing of Smart Water Meter |
| 331 | Supplying all materials, Labour & T&P for providing New House connections to beneficiaries from PHE Deptt./ WATCO CI/ DI pipe line to the property of beneficiaries/ Repair of House connection with extension of service etc. including earth work excavation, cutting of concrete / Metal/ BT road, refilling the trenches & making good to the damaged road with CC (1:2:4) after completition of the work, lifting of excess excavated materials/ debrises from work site & disposing within 5 KM radious by mechanical transport, fixing 1/8\\" dia brass/ GM ferrule with following dia. composite Strap Saddle in the CI/DI pipe line, cutting holes in brick/ stone/ RCC masonary work, repair the broken holes, cost of uPVC Schedule - 80 pipe (25 mm / 20 mm dia up to 7.0mtr /10 mtr respectively ) & fittings, 1 No of PVC Tap of approved make etc. complete as per technical & PH specification and direction of Engineer - in- Charge. |
| 332 | From 100 mm pipe |
| 333 | From 150 mm pipe |
| 334 | Replacement of damaged House connection |
| 335 | Supply of consumer water meter of size 15mm dia as per ISO 4064 including transportation etc all complete with 5 ( five ) year replacement guarantee from the date of receipt of the materials by the consignee as per direction of Engineer in charge .The water meter shall be inferential type , multijet, magnetically coupled having dry dial, Brass/Bronze body, copper can/stainless steel register with 5mm thick glas dialer class-B confiriming to ISO 4064 standard with ISI & MID certification mark, shall be with protection class of IP-68 complete with connecting pieces and all test certificate , water meter should have certificate for the model, approval as per the Indian Legal Metrology Act 2009 and weights & measure Marking ( i.e W&M marking) and confirming to the technical specification for consumer water |
| 336 | Fixing of Domestic water meter conforming to IS:779-1994 and stop cock in GI Mild Steel pipe/PVC pipe /PE pipe including cost of 15mm UPVC ball valve with solvent welded metal ball, 15mm brass NRV, 25 x 15mm Bush, 15mm FTA, 25mm or 15mm Union, 15mm pipe and any other fittings required all complete as per the direction of Engineer-In-Charge. |
| 337 | RCC Framed Boundary Wall with Fly Ash Brick Filler Wall |
| 338 | Data for 100 mtr length |
| 339 | Supplying all labour, T&P for earth work excavation in trenches in following kinds of soil within initial lead of 50m & initial lift of 1.50m including rough fressing breaking clods and laying in layers not exceeding 0.30m. In depth, levelling the bed, using pans, vessels for slushy soil and including sundries supervision charges &labour cess etc, as per direction of Engineer-in-charge |
| 340 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to work site, payment of royalty, contractor profit & labour cess etc, all complete as per specification and direction of Engineer-in-charge. |
| 341 | Supplying all labour, T&P and providing Cement Concrete (1:3:6) using 4cm HBG crusher metal including watering curing, supervision conveyance of all materials to worksite, payment of royalty, taxes etc. all complete in F&P as per specification and direction of the Engineer-in-charge. |
| 342 | R.C.C work in ground floor with cc 1:1 1/2:3 with 20mm & down grade crusher broken Granite chips |
| 343 | Supplying all materials, labour, T&P and providing rigid and Smooth centering and shuttering for R.C.C. works including False work and dismantling them after casting including Conveyance of all materials to Work site, payment of royalty,contractor profit & labour cess etc all complete as per specification and direction of Engineer-in-charge. |
| 344 | Column Base |
| 345 | Beam (on Wall Top) |
| 346 | Supplying all materials, labour, T&P and providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and laying the grill and position including cost of binding wire 18 to 20 gauge, conveyance of all materials to Work site, payment of royalty, contractor profit & labour cess etc all complete as per specification and direction of Engineer-in-charge (SAIL/TATA/Vizag STEEL TMT-EQR 500/IS 1786 Fe 500 D) |
| 347 | Supplying all materials, labour, T&P and Providing Brick work with Fly Ash Bricks 25cm x 12cm x 8cm size having crushing strength not Less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar(1:6 ) in S/S including cost of conveyance & royalty, sundries & watering for curing & supervision charges, contractor profit & labour cess etc, all complete as per the direction of Engineer-in-charge. |
| 348 | Supplying all materials, labour, T&P and making 12mm thick cement plaster in cement mortar (1:6) for brick or stone masonry work for brick work including watering, curing, conveyance of all materials to worksite, payment of royalty, contractor profit & labour cess as per the direction of engineer-in-charge. |
| 349 | Supplying all materials, labour, T&P and making 16mm thick cement plaster in cement mortar (1:6) for brick or stone masonry work for brick work including watering, curing, conveyance of all materials to worksite, payment of royalty, contractor profit & labour cess as per the direction of engineer-in-charge. |
| 350 | Supplying all materials, labour, T&P and filling of foundation and plinth with excavated materials with all kinds of soil as per the direction of engineer-in-charge. |
| 351 | Supplying all materials, labour, T&P and providing two coat of Weather Coats with any approved shades over a coat of Primer of any appproved shade & make including cost of conveyance, brushes, sundries, contractor profit & labour cess etc all complete as per the direction of Engineer-in-charge |
| 352 | Leaf MS/SS Gate fixed with RCC Pillar |
| 353 | Supplying all labour, T&P and earth work in excavation in all kinds of soil in pipe trenchs etc including dressing and levelling the bed and depositing the soil within 50M initial lead and 1.5M initial lift, as per the direction of the Engineer-in-charge. |
| 354 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to work site, payment of royalty, contractor profit & labour cess etc, all complete as per specification and direction of Engineer-in-charge. |
| 355 | Supplying all labour, T&P and providing Cement Concrete (1:3:6) using 4cm HBG crusher metal including watering curing, supervision conveyance of all materials to worksite, payment of royalty, taxes etc. all complete in F&P as per specification and direction of the Engineer-in-charge. |
| 356 | Supplying all labour, materials, T&P and providing Cement concrete (1:1½ :3) with crusher broken hard granite chips on 12mm size RCC works including cost of conveyance & royalty, sundries, watering, curing &lifting & laying concrete at a height of 5 mtr. Maximum, contractor profit & labour cess etc all complete etc all complete (Excluding cost of reinforcement & centering & shuttering) |
| 357 | Supplying all materials, labour, T&P and providing rigid and Smooth centering and shuttering for R.C.C. works including False work and dismantling them after casting including Conveyance of all materials to Work site, payment of royalty,contractor profit & labour cess etc all complete as per specification and direction of Engineer-in-charge. |
| 358 | Column Base up to plinth |
| 359 | Column |
| 360 | Supplying all materials, labour, T&P and providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and laying the grill and position including cost of binding wire 18 to 20 gauge, conveyance of all materials to Work site, payment of royalty, contractor profit & labour cess etc all complete as per specification and direction of Engineer-in-charge (SAIL/TATA/Vizag STEEL TMT-EQR 500/IS 1786 Fe 500 D) |
| 361 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment |
| 362 | Supplying all materials, labour, T&P and filling of foundation and plinth with excavated materials with all kinds of soil as per the direction of engineer-in-charge. |
| 363 | Supplying all materials, labour, T&P and providing two coat of Weather Coats with any approved shades over a coat of Primer of any appproved shade & make including cost of conveyance, brushes, sundries, contractor profit & labour cess etc all complete as per the direction of Engineer-in-charge |
| 364 | Supplying all materials, labour, T&P and Fitting & Fixing of SS Gate including cost of conveyance, contractor profit & labour cess etc., all complete as per the direction of Engineer-in-charge |
| 365 | Approach Road |
| 366 | Supplying all materials, labour, T&P and filling of road surface with borrow earth (1.0 mtr.) from the approved quarry and compacting to the required density with testing including cost of royalty, lead & transportation & labour cess etc all complete as per the direction of Engineer-in-charge. |
| 367 | Construction of granular sub-base by providing Coarse graded Grading-II material as per Table 400-2, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roll |
| 368 | Supplying all labour, material, tools & plants for Providing and laying PLAIN CEMENT CONCRETE of proportion 1:3:6 with crusher broken granite metal 40 mm size as specified, for all works from 3.5m above ground level to 1.5m below ground level in any shape, position, thickness, finishing the top surface rough or smooth, tamping, ramming, vibrating, curing etc. all complete, including cost of all materials, taxes,labour, lead, transportation of concrete, T & P all complete as per specification and direction by Engineer In-Charge . |
| 369 | M30 Grade Concrete using 20mm to 10mm size crushed stone aggregates mixed by concrete mixer, laying in layers compacting by vibrator with proper cambering and filling berm by excavated earth and all leads and lifts including frame works etc. complete in all respecte as per Scope & Technical Specification given at Section 8 & 9 of DTCN & direction of Engineer-in-Charge. (In foundation & plinth) |
| 370 | As built Drawing |
| 371 | Operation & Maintenance for 5 Years |
| 372 | O & M for 1st year |
| 373 | O & M for 2nd year |
| 374 | O & M for 3rd year |
| 375 | O & M for 4th year |
| 376 | O & M for 5th year Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail