| 1 | Supply, installation, testing & commissioning of Outdoor type Feeder Pillar panel suitable for 415 V, 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentalized & segregated design from CRCA sheet steel of 2 mm thick for frame work and 1.6 mm for covers, with 3 mm gland plates i/c cleaning & finishing complete with powder coating in approved shade, Having 4 strip aluminium bus bar of 350 Amp capacity double door with locking arrangement for protection from rain, dust, final fixed on M.S. Angle iron frame work of size 50 mm x 50 mmx 6 mm and 90 cm long legs out of which 40 cm duly grounded in cement concrete, entire panel shall have a common aluminium earth bar of size 25 mm x5mm at the rear with 2 Nos. earth stud, solid connection form main bus bar to switch gear with required size of Alu. bus bar & control wiring with 1.5 sqmm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates, duly grouted in cement concrete 1:2:4 (1 Cement : 2 Sand : 4 Stone aggrete 20 mm) and having following accessories mounted inside the cubical panel board i/c making connection, interconnection with aluminium thimbless & duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as required. (The panel should by fabricated from CPRI approved manufacturer) |
| 2 | Providing & Fixing of following electrical accessories/switches etc in the above existing panel board including making connection testing, commissioning etc. complete as reqd. |
| 3 | 250 A,50KA,FPMCCB (Ics=Icu=100%) Incoming |
| 4 | 125 A,36KA,FPMCCB (Ics=Icu=100%) Outgoing |
| 5 | Digital Volt Meter (0-500) with selector switch |
| 6 | Digital Ammeter (0-600) with selector switch |
| 7 | CT (250/5) |
| 8 | LED Indicator Lamp |
| 9 | Digital Timer |
| 10 | power contactor 110 A (ML-6 or Similar) |
| 11 | Danger Plate |
| 12 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM- 21-11 report, CCT 3000°K/4000°K/5700°K/6500°K(As per ANSBin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 13 | 150 watt |
| 14 | 200 watt |
| 15 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 16 | 200 Watt |
| 17 | Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium unarmoured cable of following size for connection of the fitting to the pole as required |
| 18 | 3 x 4 Sq.mm |
| 19 | Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium armoured cable of following size for existing RCC/HUME/METAL pipe/ Air/Surface etc complete as required. |
| 20 | 4 x 25 Sq.mm |
| 21 | Supplying & fixing of pole window cover made of G.I of 3mm thickness with sleeve type arrangement on existing pole whose cover is missing i/c welding of sleeve around pole, providing and fixing allen bolt of suitable size as per direction of Engineer-in-charge. (Note: Sample must approved before installation at site). |
| 22 | Fabrication, Designing, Supplying & Fixing of Galvanized arm street light pole bracket (single/double/tripple over hang) with tightening bolt etc. as per existing design of brackets of roads where the street light pole bracket to be fixed or as per approved by Engineer-In-Charge. (Similar type as per existing pole) |
| 23 | Fabrication, Supplying and fixing of wiremesh frame work made out of 40 mmx40mm x5mm thick Angle iron having 40x6mm flat strip & wiremesh 6 swg dia m.s wire with 25 mm x 75 mm space in between mesh & top covered for rain protection by 16 SWG MS Sheet and making main door gate having suitable locking arrangement with 2 Nos. locks (Frame size shall not be more than 60 cm x 90 cm) i/c grouting with cement concrete & painting with synthetic enamel paint of approved colour quality after applying the red oxide primer etc complete as reqd. |
| 24 | Providing, boring and laying HDPE pipes (ISI Marked) of 110 mm O.D. confirming to IS:4984-1995 as amended upto date with pressure rating of 4 Kg/Sq.c.m by trench less technology with no dig method by making bore hole in horizontal direction across the road as per direction of Engineer-In-Charge with mouling equipment i/c jointing cleaning, roadding of pipe. Providing, suitable covers on mouth of pipes, excavation of pits of required size at a depth of 1.30 mtrs. to 2.00 mtrs. |
| 25 | Supplying & erection of flange mounted hot dip galvanized (min 70 Micron) octagonal poles of 12 mtrs. height made from 4 mm thick HT steel plate having bottom dia of 200 mm & top dia of 100 mm complete with window cover made of G.I. Sheet 3 mm thick with sleeve type arrangement at a height of 1.5 mtrs from the base for cable termination block i/c welding of sleeve around pole, providing and fixing allen bolt of suitable size etc. and galvanized base plate of size 320 mm x 320 mm x 20 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination :-a) Supplying and fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4mm thick of suitable length and having suitable size tapped holes - 10nos. as reqd.b) Supplying and fixing of 63 Amp terminal block suitable for 25sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c providing and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet.c) Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 2 No. Earth stud - 2Nos. welded at suitable height two nos. washers, springs washers & nuts.d) Cable support clamp suitable for 4 Nos of 4x25sqmm cable. |
| 26 | Supplying & erection of flange mounted hot dip galvanized (min 70 Micron) octagonal poles of 10 mtrs. height made from 4mm thick HT steel plate having bottom dia of 200mm & top dia of 100mm complete with window full sleeve type cover arrangement at a height of 0.5 / 2 mtrs from the base for cable termination block etc. and galvanized base plate of size 320 mm x 320 mm x 20 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination :-a) Supplying and fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4mm thick of suitable length and having suitable size tapped holes - 10nos. as reqd.b) Supplying and fixing of 63 Amp terminal block suitable for 25sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c providing and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet.c) Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 2 No. Earth stud-2Nos. welded at suitable height two nos. washers, springs washers & nuts. d) Cable support clamp suitable for 4 Nos of 4x25sqmm cable. |
| 27 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 850 mm.(L) X 850 mm. wide and 1500 mm. deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm. dia- 1660mm long (approx)- 8 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 2800mm (approx) - 10nos. (with 150mm spacing) as required with positioning of foundation bolts (as per item below) and providing two nos. 90 mm. (O.D) DWC, HDPE Pipe for cable entry & exit as required (for 12/10 mtrs) |
| 28 | Supplying and fixing 4 Nos. 25mm dia X 750mm long GI foundation bolt (EN8 grade) with nuts, washer including 2 Nos. template of 4mm thick size 320mm x 320mm with 4 nos. 28mm dia holes, to match with PCD of Pole base plate as reqd. (For 12 mtr. & 10 mtr. Pole) |
| 29 | Supplying & erection of flange mounted hot dip galvanized (min 70 Micron) octagonal poles of 8 mtrs. height made from 3 mm thick HT steel plate having bottom dia of 150 mm & top dia of 70 mm complete with window full sleeve type cover arrangement at a height of 1.5 mtrs from the base for cable termination block and the window cover should be anti theft ring welded along with the door of size 250 mm x 5 mm G.I Strip & supported by G.I stud including providing & fixing of suitable size allen key bolt for fixing the window cover. including and P/F of galvanized base plate of size 240 mm x 240 mm x 16 mm thick on the existing cement concrete pedestal & pole connector plate as required i/c supplying and fixing of the following in the window box provided for cable termination:-a) Supplying and fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4mm thick of suitable length and having suitable size tapped holes - 10nos. as reqd. b) Supplying and fixing of 63 Amp terminal block suitable for 25sq.mm conductor -4 nos. & shorting links – 5nos. on DIN channel i/c providing and fixing DIN channel of suitable length – 2 nos. on the existing laminated sheet.c) Supplying and fixing 6 Amp, SPMCB, ‘C’ Characteristics Curve - 2 No. Earth stud - 2Nos. welded at suitable height two nos. washers, springs washers & nuts.d) Cable support clamp suitable for 4 Nos of 4x25sqmm cable. |
| 30 | Providing and laying in position (1:2:4) reinforced cement Concrete foundation of size 500 mm (L) X 500mm wide and 1200mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement ring of cold twisted bars of 12 mm dia 1350mm long (approx) 6 and reinforcement ring of cold twisted bar of 8mm dia -2200 mm (approx) 8 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing 63 mm dia (O.D.) DWC, HDPE pipe of 0.3 mtrs. length for cable entry & exit as reqd. (for 8 mtrs) |
| 31 | Supplying and fixing 4 Nos. 20mm dia X 700mm long GI foundation bolt (EN8 grade) with nuts, washer including 2 Nos. template of 3mm thick size 240mm x 240mm with 4 nos. 28mm dia holes, to match with PCD of Pole base plate as reqd. (For 8 mtr. Pole) |
| 32 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 33 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 34 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 35 | Cutting of hard rock/road/ PCC/Paver Block for laying of UG cable for Street light pole to pole with the help of hilty/ hammer etc. i/c making good by laying in position cement concrete 1:2:4: (1 Cement : 2 coars sand : 4 graded stone ) of size 0.2 B x 0.2 D mtr etc. as required. |
| 36 | Numbering of existing octagonal / decorative street lights pole installed on the road with synthetic enamel paint i/c make PWD monogram in yellow & black colour shades as specified by the department. |
| 37 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 38 | 63 mm dia (OD-63 mm & ID-51 mm nominal) Please Enable Macros to View BoQ information |