| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group B |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
| 4 | Group B |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 sq. mm |
| 7 | 3 x 4 sq. mm |
| 8 | 3 x 6 sq. mm |
| 9 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 10 | 20 mm |
| 11 | 25 mm |
| 12 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | 5/6 amps switch |
| 14 | 15/16 amp switch |
| 15 | 3 pin 5/6 A socket outlet |
| 16 | 6 pin 15/16 amp socket outlet |
| 17 | Bell Push |
| 18 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 19 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 20 | 1 or 2 module (75mm x 75mm) |
| 21 | 3 Module (100 mmX75 mm) |
| 22 | 6 module (200mm x 75mm) |
| 23 | 8 Module (125 mmX125 mm) |
| 24 | 12 Module (200m x 150mm) |
| 25 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 26 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 27 | 16 way, Double door |
| 28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 29 | Single Pole |
| 30 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 31 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 32 | Supplying, installation, testing and commissioning of 1200 mm sweep ceiling fan having copper wound motor and suitable for operation on 230 volt 50 Hz AC Supply including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable complete etc. as required. |
| 33 | Supplying, installation, testing and commissioning of heavy duty 300 mm sweep 900 rpm metallic body Exhaust Fan having copper wound motor suitable for opertion on 230 volt 50 Hz AC supply complete with shutter and louver in the existing opening/ making the hole to suit the size of the fan, making good the damage, including connection with 3x1.5 sqmm wire complete etc. as required. |
| 34 | Supplying, installation, testing and commissioning of 150 mm sweeep plastic body Fresh Air Fan having copper wound motor suitable for opertion on 230 volt 50 Hz AC supply complete with shutter and louver in the existing opening/ making the hole to suit the size of the fan, making good the damage, including connection with 3x1.5 sqmm wire complete etc. as required. |
| 35 | Supplying, installation, testing and commissioning of 200 mm sweeep plastic body Fresh Air Fan having copper wound motor suitable for opertion on 230 volt 50 Hz AC supply complete with shutter and louver in the existing opening/ making the hole to suit the size of the fan, making good the damage, including connection with 3x1.5 sqmm wire complete etc. as required. |
| 36 | Supply, installation, testing and commissioning of decorative LED mirror light suitable for wall mounting above mirror or painting, complete with all accessories, wiring and connections, comprising integrated 12 Watt LED light source operating on 220–240V AC, 50 Hz supply, with metal body and synthetic components in bronze/antique finish, having colour rendering index (CRI) ≥ 80, designed for uniform illumination of mirror/painting surfaces, suitable for indoor applications, including all fixing hardware, mounting arrangements, testing and commissioning as required, complete in all respects as per site requirements and directions of Engineer-in-Charge. |
| 37 | Supplying, installation, Testing & Commissioning of LEDRecessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim |
| 38 | 18 Watt |
| 39 | Supplying, installation & testing & commissioning of decorative wall mounting fixture with Opal Glass diffuser suitable for 9-20 W LED Lamp i/c wiring and making connections with 1.5sq.mm. PVC insulated FRLS, copper conductor single core cable including loop earthing complete etc. as required, suitable for 230 volt 50 Hz AC supply complete with all accessories/attachments etc. as reqd. |
| 40 | Supplying and fixing 63 A rating double pole, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 41 | Supplying and fixing 9-12 W LED Bollard fitting made with extruded aluminium profiles die cast aluminium base / components, U.V. resistance diamond shape polycarbonate diffuser, primer coated and painted with polyurethane paint having IP66 protection and 800 mm to 900 mm overall length suitable for single phase 230V, 50Hz electric supply complete with testing and commissioning etc. as required. |
| 42 | Supplying, installation, testing and commissioning 18 AH, 12 volt SMF battery for backup supply in lift for ARD system i/c connection and tesing as required. |
| 43 | Credit for dismantle materials |
| 44 | Assorted Ceiling Fans |
| 45 | Assorted Fresh air Fan |
| 46 | Assorted Exhaust fans |
| 47 | Assorted Switch /sockets/Regulators |
| 48 | Assorted all type indoor fittings |
| 49 | Assorted MCB |
| 50 | Assorted MCB DB |
| 51 | Assorted wire with insulation copper |
| 52 | Assorted Bollard |
| 53 | Assorted 12V Battery Please Enable Macros to View BoQ information |