Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion,Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 2 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately),Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 3 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge.Pre-laminated particle board with decorative lamination on both sides |
| 4 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 5 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.200x10mm |
| 6 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.125mm |
| 7 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 8 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 9 | Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1mm thick |
| 10 | Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge |
| 11 | Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge |
| 12 | Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. |
| 13 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 14 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 15 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 16 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 17 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 18 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 19 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) |
| 20 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 21 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 22 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.15 mm nominal dia Pipes. |
| 23 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 24 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 25 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 26 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931.15mm nominal bore |
| 27 | Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length.20 mm nominal bore |
| 28 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 29 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 30 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe.40 mm dia |
| 31 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 32 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 33 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing.Oval shape 450x350 mm (outer dimensions) |
| 34 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 35 | Providing and fixing toilet paper holder :C.P. brass |
| 36 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 37 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 38 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 39 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.TWO coats |
| 40 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Fixed window / ventilator without mullion / transom.Using R2 series with frame (39mm & above ) x (39mm & above). (Height upto 1.2 metre) |
| 41 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R3 series with frame (55 mm & above) x (50mm & above) & sash (55 mm & above) x (85mm & above) (Height upto 2.5 metre). |
| 42 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
| 43 | Providing and fixing of frost film on existing glass to make glass translucent of thickness 0.20mm as per approval of Engineer in charge. |
| 44 | Providing and fixing 18 mm thick High Density Fibre-board High moisture resistant (HDFHMR) as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-incharge. |
| 45 | Providing and fixing Ist quality polished vitrified glazed wall tiles of size 1200*600mm for wall lining by using tile adhesive of approved make conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, as approved by Engineer-in-Charge, including pointing in white cement mixed with pigment of matching shade complete. |
| 46 | Providing and fixing of 2mm thick Homogeneous flexible PVC floor covering having non -directional design, with antistatic properties of size 2mtrs x 20mtrs having total weight 3250 g/m2. (No Asian manufacturing).It also should confirm to class Bfl-s1 in flammability test as per EN13501- 1, slip resistance of R9 as per EN 13893 Class DS and very low VOC emission having Euro fins certified and GBCA/NZGBC Green Star IEQ-VOC-Compliant It shouldm demonstrate from independent tests that it inhibits the growth of MRSA on the floor to prevent any kind ofinfection. It should also achieve a BRE Global Environmental A + Rating and a Green Tag LCA Rate certified with Green Rate level A- Gold Plus Warranty: 10 years. User Class: Type 1 as per EN ISO 10581,Make : Polyflor Classic Mystique PUR |
| 47 | Self levelling of flooring by using fibre-reinforced self-levelling compound (i.e Mapei Ultrplan 3240 or equivalent) 2mm thick (avg.) on existing concrete, screeds, stone, ceramic tiles, old and new timber floors, parquet and plywood. Levelling will be done to such extent to provide level surface and no impression of existing flooring will be seen, as per direction of Engineer-in- charge. |
| 48 | Providing and fixing wall mount health faucet of plastic chrome finish, handle material of ABS, of approved quality conforming to IS standards and weighing not less than 250 gms. |
| 49 | Supply and installation of Double skin powder coated GI Door of shutter thickness 46mm as per IS 3614-2016/2021.shutter sheet thickness 1.2mm rockwool infill with 30 min insulation, Frame thichness 1.2mm Single rebate 143x58mm RAL Finish, Ball bearing butt hinges with metal screws Size: 4\\" x 3\\" x 3mm Grade SS 304 - Finish SSS., Door lock,D Handle 250x19mm, Door Closer DC 80 FR,Kick Plate 1000x300mm, 2hr fire rated glass with tape, Fire Seal, Anchor Fasteners of size M10x100mm.-or other fixture complete as per instruction of engineer in charge. |
| 50 | Providing and fixing 10 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing for required door arrangement and making necessary fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 51 | Supply of stainless steel sink of size 2800(L)*600(W)*920(H). Sink comprises of two bowl and each bowl should be of size 1400*600*300mm. Front of sink should be made of SS 304 grade shutter and inner side partition and rack for placing of chemical. Both bowl of sink should fitted with swann neck tap(Jaquar make) . There should be proper connection for drainage pipe. Sink should also have a foot control system. At back side of sink there should be extension of 300mm in height to prevent flashing of water on wall. Sink should be made of stainless steel grade 304 material and 1.2mm thick. |
| 52 | Providing and fixing of solidTop shall be covered with 12mm Thick of any color as required Colour Bendable/ Flexible acrylic solid surface. Acrylic shall be of make Neonnex or Dupont acrylic soild surface in thickness 12 mm of apporved colour made out of non-porous surfacing material homogeneously.composed of + 1/3 acrylic resin (also known as PolyMethyl MethAcrylate or PMMA),and + 2/3 Aluminium Trihydrate (ATH).The sheet size should be 2.44 mts x 076 mts . The material should have been manufactured by using high-tech and computerized controlled processes divided into various units such as mixing of raw materials casting, process on 4th generation steel belt( double belt) production technology with online quality testing process. the material should conform to national science foundation(NFC) , society general surveillance(CGS), green guard, korea testing abd research institute (KTRI), central institute of plastics engineering & technology (CIPET) testing standard and fabrications conponents warranty system(FCWS) norms. Suggested base substrates are Excel PVC Board of minimum 18 mm thckness |
| 53 | Single deck AHU (30% Fresh air & 70% recirculation):-Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7) sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 row deep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU's for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.Supply Air Fan Capacity, CFM : 1000Inline fan outdoor type of capacity 300 CFM to be installed at return ductDx Air cooled Load,TR : 08Total Supply side Static,Pa : 1500 |
| 54 | Single Deck AHU (30% Fresh air & 70% recirculation):-Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7), HEPA filter (H-14), sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 row deep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU's for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.Supply Air Fan Capacity, CFM : 1200Inline fan outdoor type of capacity 400 CFM to be installed at return ductDx Air cooled Cooling Coil Load,TR : 14Total Supply side Static,Pa : 1500 |
| 55 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet |
| 56 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet |
| 57 | Supply, installation, testing and commissioning of 0.63 mm aluminium sheet cladding as required complete in all respect with fixing screws etc., for cladding of outside / exposed ducts. |
| 58 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. |
| 59 | Supply, installation, testing and commissioning of air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core |
| 60 | Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply/Return Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 61 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Fire damper |
| 62 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications Actuator |
| 63 | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm |
| 64 | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required 25mm |
| 65 | Supply Installation, Testing & Commissioning for WARD AHU of modular type Variable Refrigerant flow /Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A/latest Refrigerant, vibration isolators, outdoor unit frame with suitable foundation,complete with all accessories as required etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at approx. 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 complete as per the technical specifications. Capacity: 30 HP |
| 66 | Supply Installation, Testing & Commissioning of AHU Kit consists of a control PCB, electronic expansion valve, complete with all accessories as required etc. This kit will connect the AHU to the VRF Outdoor Unit. |
| 67 | Supply Installation, Testing & Commissioning of Corded Thermostat cum controller for temperature setting and operation, along with communication and power wiring from AHU or VRF to Remote controller installation as per location inside ward complete with all accessories as required etc. (Dual mode: Cooling & Heating). |
| 68 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, complete with all accessories as required etc. 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 69 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, complete with all accessories as required etc.28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 70 | Supply, Installation, testing and commissioning of 40 mm dia nominal bore 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings likes elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. complete in all respect for AHU condensate drain piping with 19 mm thick nitrile rubber insulation, nut-bolts, supports, pipe support block etc. duly installed with 0.63 mm aluminium sheet cladding as required complete in all respect with fixing screws etc. |
| 71 | SITC of Laminar flow filter module of suitable size as required made out of heavy duty Aluminium powder coated extrusion with minimum and to house HEPA Filter at the rate 0.3 microns , 99.9997, H- 14Grade, Filter loading from ICU side Includes aluminum power coated capsule perforated diffuser alongwith adjustable opposed blade damper. This includes all required supports and accessories as per site requirement. Size - 600mm x 600mm |
| 72 | Supply, Installation, Testing & Commissioning of Electric tubular finned Heaters for OT OAHU of 04 kW capacity in SS construction and bank wise distribution, duly installed in ducts complete with mounting arrangement, safety thermostat, humidistat for humidity control, SSR based control, contactor etc.. Heater should be ISI marked. |
| 73 | Fabrication,Supply,Installation,Testing,Commisioning of Outdoor floor mount type AHU control Panel, CPRI approved with following specifications: CRCA Sheet of 3.15 mm, Grey Colour with Incoming: 1 Incomer -250 Ampere MCCB/36KA 4 Pole. Panel must include R,Y,B Indicator, with 350 ampere aluminium busbar, 1No Digital Multi Function Metre / Digital Load Manager suitable to connect with Centre Energy Monitoring System/BMS through RS485 connection.Outgoing:Outgoing -1 Nos with 25 Ampere MCB/10/16KA 4 Pole “C” Curve for supply motor - 4 kW Outgoing - 1 Nos with 25 Ampere MCB/10/16KA 4 Pole “C” Curve for supply motor - 3 kWOutgoing -1 Nos with 100 Ampere MCCB/30KA 4 Pole for VRF outdoor unit. Outgoing -1 Nos with 32 Ampere MCCB/16/25KA 4 Pole for heaters - 04 kW (three bank distribution).Outgoing -1 Nos with 32 Ampere MCCB/16/25KA 4 Pole for heaters - 04 kW (three bank distribution) All outgoings shall be with necessary MCB's, contactors, relays, illuminated push button for manual ON & OFF, indication lamps ( for ON,OFF,TRIP Status), Auto/Manual selector switch..Outgoings with suitable rating MCB's shall be considered for UVGI system, fire damper, AHU limit switch etc.Necessary safety interlocks like AHU motor interlock with service door limit switch, fire damper interlock, supply & exhaust fan interlock, UVGI system and heaters interlocks with AHU).Potential free Contact (for supply motor, exhaust motor, fire damper, heater, humidifier etc.) to be provided for Connections.Note:-1. VFD (for motor speed control) with inbuilt PID controller for varying the speed of fan, along with DPT (0 to 3000 pa) sensor for measuring DP across fan and providing input to VFD. VFD to be installed/mounted in motor control panel.Capacity of VFD: 4 kW - 1 No. ( for Supply motor) Capacity of VFD: 3 kW - 1 No. ( for Supply motor) 2. Provision of MCB / Contactor for UVGI system, AHU limit switch, Fire damper etc. to be considered in AHU control panel. |
| 74 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured aluminium cable 3.5 C X 95 sq. mm |
| 75 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 4 C X 16 sq. mm |
| 76 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 4 C X 10 sq. mm |
| 77 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 4 C X 6 sq. mm |
| 78 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 4 C X 1.5 sq. mm |
| 79 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 2 C X 1.5 sq. mm |
| 80 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 150 mm width X 50 mm depth X 1.6 mm thickness |
| 81 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 100 mm width X 50 mm depth X 1.6 mm thickness |
| 82 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 83 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 84 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C |
| 85 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit asrequired.recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 86 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit asrequired.recessed steel/ PVC conduit as required 6 x 4 sq. mm |
| 87 | Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm |
| 88 | Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 89 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch |
| 90 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch |
| 91 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 92 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet |
| 93 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 94 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required 6 Module (200mmX75mm) |
| 95 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module |
| 96 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module |
| 97 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt),Supplying, installation,Testing & Commissioning of Panel light 2x2 ft.,of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19,Flicker free,(flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life, CCT /6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm), 36 Watt |
| 98 | Dismantling & taking away the scrap of burnt all sizes MS box/GI box/Switch/ Socket/misc scrap of electrical Items (against credit) in following forms:- 5A/15A switch |
| 99 | Dismantling & taking away the scrap of burnt all sizes MS box/GI box/Switch/ Socket/misc scrap of electrical Items (against credit) in following forms:- 5A/15A Socket |
| 100 | Dismantling & taking away the scrap of burnt all sizes MS box/GI box/Switch/ Socket/misc scrap of electrical Items (against credit) in following forms:- Iron Scrap (Metal box and conduit, Iron Angel etc Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail