| 1 | Taking down cement plaster of any description from walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water etc. removal of rubbish off the premises and removal of debris out side from MD land etc complete all as specified and directed. |
| 2 | M&L for 15mm thick rendering in CM (1:6) internal plaster on brick/concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed. |
| 3 | M&L for rendering in CM (1:4) 20 mm thick in two coats (15 mm under coat + 5mm finishing coat) on brick/concrete surfaces with water proofing compound @3% by weight of cement in finishing coat and finishing the surface even and fair. (Note :- WPC will be measured and paid seperately). |
| 4 | M&L for rendering 5 mm thick on fair faces of brick or concrete surfaces of ceilings in CM (1:3), finished even and smooth without extra cement complete all as specified |
| 5 | Supply only integral WPC all as specified & directed. |
| 6 | M&L for preparation of newly plastered surfaces and applying two coats of oil bound distemper paint on walls over a coat of alkali resistant primer including 1.5mm wall care putty, complete all as specified and as directed . |
| 7 | M&L for preparation on new plastered surface of wall, chajja, parapet etc and applying two coats of acrylic emulsion paint (two or more coat applied @ 1.67 ltr/10 sqm over including priming coat of exterior primer applied @ 2.20 kg/10 sqm) including 3mm wall care putty, complete all as specidied and as directed |
| 8 | M&L for preparation of newly plastered surfaces and applying two coats of oil bound distemper paint on ceiling over a coat of alkali resistant primer including 1.5mm wall care putty complete all as specified and as directed . |
| 9 | Taking down door/ window/ventilator shutter with frame (without taking off shutters from frame) of any description n.exc. 1.50 Sqm each etc complete all as specified and as direted. |
| 10 | Taking down door/ window shutter with frame (without taking off shutters from frame) of any description exc. 1.50 Sqm not exc 4.00 Sqm each etc complete all as specified and as direted. |
| 11 | M&L Granite 20mm thick (of any type) work (table rubbed and polished) in shelf, jambs, window cills, partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 12 | S & F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides. complete all as specified and directed. |
| 13 | M&L for 0.90 mm thick decorative laminate type 1, laminates on flat or curved surfaces in any size or width , of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.. |
| 14 | S&F for Butt hinges, medium weight 100MM Size, cold rolled mild steel, and fixed to chowkhat and door, complete all as specified and directed. |
| 15 | S&F for Butt hinges, medium weight 125MM Size, cold rolled mild steel, and fixed to chowkhat and door, complete all as specified and directed. |
| 16 | S&F for 200mm long brass barrel tower bolts with cast or sheet barrel and rolled or cast bolts and fixed. |
| 17 | S&F for 150mm long brass barrel tower bolts with cast or sheet barrel and rolled or cast bolts and fixed. |
| 18 | S&F for 250mm long Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed. |
| 19 | S&F for 150mm size extruded brass handles fabricated type, polished etc complete all as specified and directed |
| 20 | S&F for 125mm size extruded brass handles fabricated type, polished etc complete all as specified and directed |
| 21 | S&F for floor door stopper of brass body and tongue with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm. |
| 22 | S&F 30mm thick Glazed and skeleton shutters in 1st class soft wood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specified. |
| 23 | S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples all as specified. |
| 24 | M&L 2nd class hard wood Plain fillets square, rectangular or triangular in section, clean sawn, secured with nails or brads, sectional area n exc. 3 sq.cm, complete all as specified and as directed. |
| 25 | M&L for preparation of new wooden surfaces of any description, not otherwise descri-bed, over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of pink primer, Complete all as specified and directed. |
| 26 | S&F for Aluminium (extruded section) body Door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 60 to 80 Kgs. complete all as specified and directed. |
| 27 | Resecuring or easing adjusting without taking down rolling shutter making full functional in all respect of steel rolling shutter of any description exceeding 2 Sqm, Complete all as specified and directed. |
| 28 | M&L for Preparation of old steel surfaces of any description over 10 cm width or girth, not otherwise described and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 29 | Dismantling of posts struts (wood , steel or RCC) any section incl taking out embedded portion in concrete or brick and making good. |
| 30 | Dismantling of fencing wire /barbed wire, any type |
| 31 | Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 32 | M&L Plain cement concrete (1:4:8) type D-2, using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified. |
| 33 | M&L for formwork to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed. |
| 34 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished square, rectangular or polygonal surfaces of concrete complete all as specified and directed |
| 35 | M&L for formwork to faces of sides and soffits of floor or roof beams, cantilevers, shelves including supports, overhangs, etc for rough finished flat surfaces of concrete complete all as specified and directed |
| 36 | M&L for reinforced cement concrete (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc; basement slabs under reamed pillars and mass concrete complete all as specified and directed.(Note: Steel reinforcement shall be measured & paid separately) |
| 37 | M&L for reinforced cement concrete (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as in column, pillars, piers, post and struts complete all as specified and directed.(Note: Steel reinforcement shall be measured & paid separately) |
| 38 | M&L for reinforced cement concrete (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels complete all as specified and directed.(Note: Steel reinforcement shall be measured & paid separately) |
| 39 | TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 40 | TMT bars 8 to 10 mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 41 | Materials and Labour for factory made precast cement concrete block masonry (1:3:6) type C1 using 20 mm graded stone aggt with solid blocks, exc10 cm in width, set in cement morter (1:6) in wall (below or above ground level) complete all as specified and directed. |
| 42 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 43 | Removing excavated soils to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. |
| 44 | M&L for broken stone or boulder hardcore of gauge n exe 63mm deposited, spread and levelled in layers n exe 15cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 45 | M&L for providing precast cement concrete louvres and jallies, type B0 1:2:4 (12.5mm graded aggregate) set in CM 1:4, 50mm thick (measured solid), including all mouldings but excluding frame(Pre cast frame shall be measured separately), complete all as specified and directed. |
| 46 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles to store and rubbish off the premises and removal of debris out side from MD land etc complete all as specified and directed. |
| 47 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick rendering in CM (1:4) as in backing coat complete all as specified and directed. |
| 48 | S&F for glazed ceramic coloured tiles 300x600x7mm thick on vertical surfaces such as skirting / dados set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in CM (1:3) as in backing coat complete all as specified and directed. |
| 49 | S&F for vitreous china WHB white, flat back size 550mm x 400 mm including cutting for and pinning in ends of CI brackets, 32mm dia waste pipe and making good wall or floor fitting to match existing surface inlcuding taking down old complete all as specified and directed |
| 50 | S&F for looking mirror 900mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plgs with chromium plated brass screws and cup washers inlcuding taking down old complete all as specified and directed |
| 51 | S&F in repair vitreous china, 1st quality urinal half stall type, white, with and including brass chromium plated flush pin, 40mm dia brass CP waste coupling and 40mm dia PVC HDPE waste pipe with all other necessary fittings etc complete all as specified and directed. |
| 52 | S&F for 32MM dia bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms), complete all as specified and directed. |
| 53 | S&F for 15mm size Stop Valves fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends etc inlcuding taking down old complete all as specified and directed |
| 54 | S&F for PVC connections 15mm size with PTMT nuts of length 600mm |
| 55 | S&F for 15 mm dia bore medium grade galvanized steel tubing with all fittings fixed to walls, ceilings or laid under floors including takong up or down, complete all as specified and directed. |
| 56 | S&F for 20mm dia bore medium grade galvanised steel tubing with all fittings fixed to walls, ceilings or laid under floors including takong up or down, complete all as specified and directed. |
| 57 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exceeding 10cm girth, complete all as per specified and directed. |
| 58 | S&F for standard size EWC white colour with P/S trap white coloured with and including PVC white coloured seat cover,10 ltr capacity PVC valveless,syphonic action type, low level flushing cistern with inlet, ball valve, float valve and handle including brackets including all connecting to flushing cistern (32mm dia waste pipe inlcuding taking down old complete all as specified and as directed. |
| 59 | S&F for 2 way CP Bib cock double handle with flange and all necessary fittings inlcuding taking down old complete all as specified and directed |
| 60 | S&F for Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed. |
| 61 | S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and as direted. |
| 62 | Supply, and fixing 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and jointed at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickenss. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm ( + 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by insering horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as specified by the manufacturer and as per directions of Engineerin- charge. |
| 63 | S&F for aluminium powder coated frame (minimum thickness of powder coating 50 micron) in any position such as door, window & ventiator frame, grills, guard bars etc members made out of extruded Aluminium of any section and in any position including fixing Clips and provision of roller for fixing of prelaminated particle board , roller and roller plate for fixing of shower cubicals all as specified and directed. Make of aluminium section - ''Jindal/ Indalco/ Hindalco. |
| 64 | S&F for powder coated aluminium fixed / sliding window and ventilator shutters, aluminium sections weighing 0.55 kg/m, including, rubber gasket, PVC wheel with ball bearing, concealed type lock and fixing of glass complete all as specified and directed. Make of aluminium section - ''Jindal/ Indalco/ Hindalco. Note: (i) The measurement shall be recorded weight of aluminium section only and rate quoted shall deemed inclusive of rubber gasket, rubber beading, PVC wheel with ball bearing, concealed type locks, handle etc (ii) Glass and steel wire cloth shall be measured and paid separately as supply only. |
| 65 | Supply only 5.50 mm thick float glass (area of each pane exc 0.50 sqm) fixed in aluminium sliding window/door shutters etc complete all sas specified and directed. |
| 66 | S&F for Solar controlled film 50 micron reflective type sticked to glass as per instructions of manufacturers all specified and directed. |
| 67 | S&F for 20mm dia & 60 cm long `D' type, chromium plated brass tubular towel rail between flanges inlcuding taking down old complete all as specified and directed |
| 68 | S&F for 15mm bore fancy type bib tap, cromium plated alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed inlcuding taking down old complete all as specified and directed. |
| 69 | S&F for soap dish of PTMT any colour fixed with and including CP brass screws and wooden/plastic cleats inlcuding taking down old complete all as specified and directed |
| 70 | S&F for towel ring of long PTMT fixed with and including chromium plated brass screwes and wooden/plastic cleats (minimum weight 90gms) inlcuding taking down old complete all as specified and directed |
| 71 | S&F for CI floor/nahani trap 75mm dia with grating, incl jointing to waste pipe in run lead complete and making good the disturbed surface to match existing surface inlcuding taking down old complete all as specified and directed |
| 72 | Demolition & breaking up drain pipes upto 110/75 mm dia (salt glazed ware, AC,PVC or reinforced concrete) set in cement mortar. |
| 73 | S&F for 75mm bore of pipe PVC (SWR) pipes single socketted in any length with rubber ring joints laid in walls / floors etc complete all as specified and directed. |
| 74 | S&F for 110mm bore of pipe PVC(SWR) pipes single socket in any length with rubber ring joints laid in walls /trenches or in floors etc complete all as specified and directed. |
| 75 | S&F for PVC (SWR) 75mm Bore Bends any radius |
| 76 | S&F for PVC (SWR) 110mm Bore Bends any radius |
| 77 | S&F for PVC (SWR) 75mm Bore vent cowl |
| 78 | S&F for grating doom 100mm dia of PTMT (min weight 25gms) inlcuding taking down old complete all as specified and directed |
| 79 | S&F for grating doom 100mm dia with waste hole of PTMT (min weight 40gms) inlcuding taking down old complete all as specified and directed |
| 80 | S&F in repairs shower arm 15mm size, 195mm long with bend of 45 degree with flange of PTMT any colour (Min wt 40 gms) |
| 81 | S&F for Brass Chromium plated shower roses 125MM Sizewith or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed. |
| 82 | Dismentling stone sett/interlocking paver tiles of any description of any thickness laid dry of laid dry by pointing, complete all as specified and directed. |
| 83 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including taking down old and removing from MoD land, complete all as specified and directed. |
| 84 | M&L for 100mm thick PCC type C-2 (1:3:6) (using 40mm grade stone aggregate) as in sub base of floor and path, Complete all as specified and directed. |
| 85 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, Complete all as specified and directed. |
| 86 | S&F Mild steel rolled work as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other coving, running rails and guides) and hanging; also fastening and fixing complete, conforming to grade Fe 410 -W (GdeE- 250) qualityA |
| 87 | M&L for two coats of synthetic enamel paint on steel surfaces girth exc 10 cm and over a coat of red oxide incl preparation of new steel surfaces complete all as specified and directed. |
| 88 | Supply and Application of 5 Layer SHR Waterproofing Coating System as per manufacturer application procedure on leaking concrete roof surface by thorough surface preparation with high pressure water jet, having a pressure of min. 125 bars, followed by (a) Opening the cracks, and application of one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance having min. 50% solids, filling and sealing the cracks, (b) Over coating with 2 Coats of NEEWP + Cement mixture as waterproofing coat having +450% Elongation followed by curing. (The surface is then to be tested for water tightness with ponding test for min. 2 days) (c) Top-coated with 2 Coats of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa The material must have passed 2000 hrs accelerated durability test, suitable for all types of cementitious surfaces, white colour, matty finishing, Thickness shall not be less than 120 microns using brush, roller, airless spray gun as applicable. The product should be certified by NABL Approved Lab and application is to be done by company approved applicator only |
| 89 | Taking down carefully copper/aluminium point wiring (light,fan socket or power) point complete,including fixtures and fittings such as switches, ceiling rose, pendents, regulators, sockets, tube light fitting,main switch,MCB and DB's etc complete all as specified and directed. Please Enable Macros to View BoQ information |
| 90 | Taking down carefully copper/aluminium point wiring (light,fan socket or power) point complete,including fixtures and fittings such as switches, ceiling rose, pendents, regulators, sockets, tube light fitting,main switch,MCB and DB's etc complete all as specified and directed. Please Enable Macros to View BoQ information |