| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : CE BATHINDA ZONE Name of Work: PROVISION OF BAFFLE RANGE AT BATHINDA MILITARY STATION (JOB NO SW/233) Contract No: CE BTZ/FDK/TOKEN-75 OF 2025-26 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 3 | Schedule 'A' Part-I (A) (BAFFLE RANGE (300 METRES))Material and labour for Costruction of BAFFLE RANGE (300 METRES) complete all as specified and directed. (Ref Schedule A Notes) |
| 4 | Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I (B)(Ref pre-priced schedule attached separately) |
| 5 | Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately) |
| 6 | Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately) |
| 7 | Lump sum price worked out by the tenderer for ROAD, PATH, HARD STANDING AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately) |
| 8 | Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately) |
| 9 | Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately) |
| 10 | Lump sum price worked out by the tenderer for COMPOUND WALL, SECURITY FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately) |
| 11 | Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately) |
| 12 | Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION & STANDBY DG SUPPLY as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately) |
| 13 | Lump sum price worked out by the tenderer for SUMMER COOLING APPLIANCES as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately) |
| 14 | Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately) |
| 15 | Schedule 'A' Part-XII(MISCELLANEOUS PARTS) |
| 16 | M & L for supplying approved earth from MOD land and forming embankments including raising (or lowering) earth, spreading in layers not exceeding 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., not exceeding 1.5 m high from base complete all as specified and as directed. |
| 17 | Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 10(1.00 Mpa), material grade PE 100 and nominal outside dia 32 mm as per IS 4984: 2016 including all fittings and fixtures as per IS 8360 : 2022 or IS 8008 : 2022 in trenches complete all as specified and as directed. |
| 18 | Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 10(1.00 Mpa), material grade PE 100 and nominal outside dia 50 mm as per IS 4984: 2016 including all fittings and fixtures as per IS 8360 : 2022 or IS 8008 : 2022 in trenches complete all as specified and as directed. |
| 19 | Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 10(1.00 Mpa), material grade PE 100 and nominal outside dia 63 mm as per IS 4984: 2016 including all fittings and fixtures as per IS 8360 : 2022 or IS 8008 : 2022 in trenches complete all as specified and as directed. |
| 20 | Supply and lay high density polyethylene pipe (HDPE) of pressure rating PN 10(1.00 Mpa), material grade PE 100 and nominal outside dia 90 mm as per IS 4984: 2016 including all fittings and fixtures as per IS 8360 : 2022 or IS 8008 : 2022 in trenches complete all as specified and as directed. |
| 21 | Material and labour for Cutting of existing CI pipe line 150mm bore for inserting and including tee of size 150x150x100mm for taping in trenches including run lead joint complete all as specified and as directed.NOTE:- Necessary earth work, CI fitting/lead joints etc reqd to complete the job deemed to be included in the quoted rate. |
| 22 | S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 170, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed. |
| 23 | M & L for on site Hume Pipe septic tank for 05 users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for brick work in CM 1:4 plastering mixed with WPC incl RCC/CI manhole cover, cement pipe & Sludge chamber complete all as specified and as directed. |
| 24 | Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed. |
| 25 | M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 26 | M & L for concealed point wiring for one light controlled by two 2-way switches complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 27 | M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 28 | M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 29 | M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.) |
| 30 | S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 31 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 32 | M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 2.5 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 4.00 mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanised iron from pipe electrode to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 33 | Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) |
| 34 | Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.) |
| 35 | S & F blanking plate in DBs of MCB complete all as specified and as directed. |
| 36 | M & L for construction of new valve pit/chamber of size 1200 mm (Length) X 1200 mm (Breadth) X 1200 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. |
| 37 | M & L for construction of new valve pit/chamber of size 900 mm (Length) X 900 mm (Breadth) X 900 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed. |
| 38 | S & F vertical distribution board multi phase, double door, 4 way including MCCB (rated current(In): 200A, ultimate short circuit breaking capacity (Icu): 25 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, fixed thermal and fixed magnetic setting, four pole, suitable for 415 V, 50 Hz AC) as incoming and MCB (single pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20) as outgoing complete all as specified and as directed. |
| 39 | Supply and erect factory made 7 meter long hot dip galvanized (as per relevant IS with average coating thickness 65 micron) octagonal poles conform to IS-2062/ BSEN 10025 with 155 mm dia at bottom and 70 mm dia at top A/F made up of 3 mm thick HT sheet along with foundation type base plate of size 250 mm X 250 mm X 16 mm, foundation bolt 4 Nos of M20 X 600 mm high 'J' type EN8 grade, including 1 meter long hot dip galvanized single arm (swan neck) bracket made up of 40 NB dia GI pipe and including excavation, earth work, PCC (1:2:4) type B1 for foundation and grouting the bolts as per manufacturer’s instructions including marking pole number in letters & figures of size not less than 10 cm height with red colour enamel paint complete all as specified and as directed. Note: - (i) Srl number will be issued by Engineer-in-Charge. |
| 40 | S & F LED street light fitting of 60 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.(a) Lumen system efficacy of luminaire should be minimum 120 Lumen per watt. (b) Input Voltage range: 140 to 270 volts (c) Temp operating range: Minus 10°C to Plus 50°C (d) Power factor: Minimum 0.95 (e) THD: Max10%. (f) IP rating: Minimum IP66. (g) IK rating: Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz. open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 Kv (inbuilt + extended) (l) CCT: 5700 K. (m) CRI: More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time: 50000 burning hrs @L70 (Average 10 to 12 hrs daily) |
| 41 | M & L Decorative LED post top lantern (PTL) luminaire with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acrylic diffuser LED light fitting of 15 watt including LED lamp complete all as specified & directed. |
| 42 | S & F pole mounted PVC junction box, with aluminium bus bar suitable for 3 phase and neutral including MCB SPN 6A 10 KA complete all as specified and as directed. Make: Sintex/ Universal |
| 43 | M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of pipe of 40 mm and 100 mm nominal bore complete all as specified and as directed. |
| 44 | Supply and fixing Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia and 8mm thick with provision of 500 mm long (minimum) single leg/stand of angle iron 40x40x5 mm, welded/riveted on back side of plate, fixed and grounted in position with with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate block of suitable size complete all as specified and as directed by Engineer-in-Charge. |
| 45 | Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, voltage stabilizer of capacity 2 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed. |
| 46 | S & F evaporative air coolers (desert coolers) as per IS 3315: 2019, minimum air capacities 4000 cum per hour, sump tank capacity 80 litres, cooling efficiency not less than 65%, maximum power consumption 280 watts, plastic body, noise level not more than 65 dBA at 1 m distance including connecting up with three core flexible copper conductor cable of suitable size including numbering of coolers using two coats of synthetic enamel paint complete all as specified and as directed. |
| 47 | Supply, installation, testing and commissioning of silent Diesel Engine driven generating set to given an output of 40 KVA, 415 Volts. 3 phase, 50 HZ, 4 wire directly coupled to diesel engine, water cooled, turbo-charged after cooled type, mounted on common base plate complete with fuel tank of adequate capacity, vibration damper, other accessories with acoustic enclosure and alternator with AMF Panel complete with latest CPCB norms including PCC foundation etc complete all as specified by the manufacturer and as directed by Engineer-in-charge including comprising of followings: -DIESEL DRIVEN ENGINE. Developing a net directed output 45 BHP or nearest higher suitably marked with alternator to give a net directed output of 40 KVA. The engine shall be capable of delivering the required output at 1500RPM at NTP, Water cooled, turbo-charged after cooled, four stoke, conforming to BS 5514 under NTP conditions with provision of 10 % overload capacity for one hour in every 12 hours including comprising of following: - (i) Fly wheel to suit flexible coupling and fly wheel housing. (ii) Radiator assembly complete with fan water pump and thermostat. (iii) Fuel injection as per manufacturer specification. (iv) Electrical Coil as per manufacturer's instructions/design. (v) Oil filter with mounting arrangements. (vi) Lubricating oil pump and cooler. (vii) Self-starter 12 volts. (viii) Exhaust silencer with including cladding with pigeon protection residential type exhaust noise level complying with CPCB norms. (x) Suitable controller with start, stop, Auto/manual, Reset button as per manufacturer instruction. (xi) Engine protection safety device for low lubricating oil pressure, high coolant temperature. (xii) Dynamo/Alternator with over charging protection. (xiii) Batteries 12 volts, 90 AH (Min) or suitable capacity as per manufacturer's design with lead etc- 01 No. maintenance free battery |
| 48 | Srl Item No 14.031 Continued......(B) ALTERNATOR. The engine shall be coupled through flexible coupling to an Synchronous alternator mounted on a strong steel/MS fabricated common base frame suitable for mounting on a permanent foundation. The alternator shall be 3 phase, 50 Hz, 1500 RPM, self-excited, self-regulating and Brushless type provided with suitable automatic voltage regulator and shall be confirm to BS: 2613 or BS: 5000 and generating 40 KVA output after de-rating with coupled to diesel engine at 0.8 to 1 power factor lag, 415 volts, 4 wire, AC supply under NTP conditions. The alternator will confirm the following feature. (i) IP 23 protection with H class insulation. (ii) Permissible overload of 10% for one hour in 12 Hour operations (iii) Automatic voltage regulator (AVR) - Fast response electronic Type.(C) AUTO MAIN FAILURE (AMF) CONTROL PANEL : Microprocessor based design/Motorized operated HPL 200 Amp changeover switch and suitable contactor, outdoor type made out of CRCA sheet of 3.15 mm thick confirming to IS 8623 totally enclosed, dust and vermin proof with front and rear opening, 415 volts, 3 phase, 4 wire, AC 50 Hz having aluminum bus bar of capacity as required to carry current at 110% load of 40 KVA DG Set with three phase and half neutral colour coded, pre wired with aluminum cable of suitable size all as per standard practice of manufacturer specifications with the following accessories :- (i) MCCB 4 pole 200 Amps adjustable type, 35 KA for DG (ii) MCCB 4 pole 200 Amps adjustable type, 35 KA for mains (iii) Combined digital type meter for AC/DC Voltage/Amp/frequency (iv) Combined digital type meter for KW/Power Factor/KVA. (v) Safety interlock: Mechanical and electrical interlocking for contactors (vi) Electronic KWH meter (counter display) (vii) Inbuilt Battery Charger (viii) Supply failure timer and restoration timer. (ix) 3 impulses automatic engine start/stop logic and engine fails to start lockout mains/senator voltage and frequency sensing. (x) Automatic manual switch (xi) Hooter (xii) Earth fault relay (xiii) SMPS based unit with inbuilt auto/manual and float/boost facility. (xiv) Cost for foundation of AMP panel and suitable control wiring from DG panel to AMF panel up to 50RM deemed to be included in the quoted rate. (D) BASE FRAME: Engine and Alternator directly coupled on a common channel iron fabricated base frame with predrilled holes. (E) FUEL TANK: Daily service fuel tank of suitable capacity (min 12 Hrs capacity running at full load) fabricated from 14 SWG sheet metal complete with drain valve, inlet and outlet connection. |
| 49 | Srl Item No 14.031 Continued......(F) ACCOUSTIC ENCLOSURE: Enclosure be designed for reducing the sound level 75-5db (Average) as per ISO 8528 part 10 as per approved CPCB norms. The acoustic enclosure must consist of following: - (i) CRCA sheet with Body 16 SWG and Roof 14 SWG thick duly powder coated. (ii) Base frame be fabricated of ISMC channel or in sheet metal, base frame will be prime coated and painted. (iii) Insulated rock wool fire retarded/non igniting and noise reduction type, properly clamped and shall be provided an all doors, roof and sides to absorb noise. (iv) Special designed stainless steel door locks and door hinges. NOTES: (i) The panel will be complete with internal wiring with suitable size of copper cable. (ii) The panel shall be duly tested and comply with CPRI test standard. (iii) DG set shall be placed on PCC/RCC Platform as per CPCB of suitable size, minimum one meter extended all around the DG set. Height of platform from ground level shall be minimum 200 mm and depth below GL as per OEM recommendation. Cost of PCC/RCC platform is included in the quoted rate of DG Set. (iv) Cost of spare parts shall not be included in the cost of DG set. (v) Tools shall be supplied as per user manual and cost thereof shall be included in the cost of DG set. (vi) The DG set and acoustic enclosure shall be complete one unit and it shall be installed as one complete set. (vii) Thermostat switch inside the acoustic enclosure shall be provided to shut off the DG set in case temperature increases beyond 70 Degree centigrade inside the acoustic enclosure. (viii) Necessary grounding mild steel nuts, bolts, washers etc and anti-vibration pad shall be provided by the contractor. (ix) Initial filling of lubricating oil/ coolant and fuel and complete arrangement required for testing will be provided by the contractor |
| 50 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 75 mm, minimum inside dia 56 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 51 | Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 120 mm, minimum inside dia 90 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed. |
| 52 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3.15 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: -(A) 150 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos(B) Wiring with single core PVC, copper power cable of suitable size(C) Incoming: (a) MCCB rated current (In): 100 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No(D) Outgoing:(a) MCB, TPN, 10 kA, C-type, 415 V, rated current 10 A: -3 No(b) MCB, SPN, 10 kA, C-type, 230 V, rated current 20 A: -4 Nos(c) MCB, SPN, 10 kA, C-type, 230 V, rated current 10 A: -8 Nos(d) MCCB rated current (In): 16 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, 3 pole, for 415 V, 50 Hz AC supply: -1 No |
| 53 | (E) Accessories:(a) Multifunctional meter digital type showing voltage, current, frequency, power factor, Kilo watt, Kilo watt hour with inbuilt selector switch with current transformer coils for three phase: - 1 No(b) LED indicating lamps – 3 Nos(c) Danger Notice Plate for LT(d) Three phase digital timer switch with contactors for auto switch on-off of street lights- 01 set (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm |
| 54 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3.15 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: -(A) Incoming: (a) MCCB rated current (In): 100 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No |
| 55 | Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3.15 mm thick with 40 mm X 40 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 40 mm X 40 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: -(A) 100 Amps rated aluminium bus bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos(B) Wiring with single core PVC, copper power cable of suitable size(C) Incoming: (a) MCB, TPN, 10 kA, C-type, 415 V, rated current 32 A: -3 No |
| 56 | Supply and fixing three core (3x1.5sqmm) flexible flat/round cable, copper conductor multistranded, PVC insulated and overall PVC sheathed, 1100 volt, drawn through LT steel tubular poles or drawn through GI pipe along PCC pole for connection to street light from junction box to light complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail