| 1 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good to distrubed natural ground complete all as specified and as directed. |
| 2 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good to distrubed in concrete or brick work complete all as specified and as directed. |
| 3 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 5 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 6 | M&L for TMT steel bars 10 mm dia and above, as in reinforcement for concrete, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and as directed. |
| 7 | All as per item No 06.00 (here-in-before) but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders. |
| 8 | M&L for providing reinforced cement concrete type B-1, (1:2:4) (using 20mm graded stone aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc for fencing, average sectional area exc 100 sqcm and not exc 250 sqcm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and as directed. |
| 9 | M&L for angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 10 | S & F galvanised 2 stranded steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rail strain -ing Bolt , including, securing or tying at crossing with and provision of galvanised mild steel wire , staples or steel pins etc including dismantling the old barbed wire, complete all as specified & directed |
| 11 | All as per item No 10.00 (here-in-before) but restraining & resecuring including making good staples etc. |
| 12 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in soft/ loose soil complete all as specified and as directed. |
| 13 | M&L for PCC Type C-2 (1:3:6) (using 40mm graded stone aggregate) as in foundation of post holes complete all as specified complete all as specified and as directed. |
| 14 | Dismantling of Chain link fencing any size or type complete all as specified and as directed |
| 15 | Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed. |
| 16 | Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire complete all as specified and as directed. |
| 17 | M&L for mild steel round bars 10 mm dia and over cut to length bend to shape as required, including straightening etc as required in horizontal bar for securing chain link fencing complete as specified and directed. |
| 18 | Supply and fixing Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long - 11 to 15mm Diameter of neck complete all as specified and and as directed. |
| 19 | M&L for preparation of new steel surface n exc 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and and as directed. |
| 20 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces etc complete drilled for fixing of steel sheeting or other covering . doors etc to be prepared for hanging or slinding with and including either hooks and hings or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides ) and hanging also fastening and fixing complete. including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and and as directed. |
| 21 | M&L for Rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc conforming to Fe-290 Gde E-165 complete all as specified and and as directed. |
| 22 | M&L for preparation of new steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and and as directed. |
| 23 | M&L 75mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed. |
| 24 | M&L 100mm thick PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in floor finishes the surface finished even and fair and making impression of expanded metal whilst concrete is green complete all as specified and as directed. |
| 25 | M&L 40mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in floor laid in alternate bays, finished the surface even and smooth without using extra cement complete all as specified and as directed. |
| 26 | M&L for brick work with sub class `B' bricks(using old size burnt bricks) straight or curved on plan exc 6m mean radius built in CM (1:6) including demolition of old brick work from its position complete all as specified and as directed. |
| 27 | M & L for rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound @ 3% by wt of cement finished fair faces of brick/concrete surfaces even and fair without using extra cement including taking down old plaster from its position complete all as specified and directed.Note:-WPC will be measured and paid separately. |
| 28 | M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick or concrete work and surfaces finished even and smooth without using extra cement including taking down old plaster from its position complete all as specified and directed. |
| 29 | M&L for rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound @ 3% by wt of cement finished fair faces of brick/concrete surfaces even and fair without using extra cement i complete all as specified and directed.Note:-WPC will be measured and paid separately. |
| 30 | M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick or concrete work and surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 31 | Supply only integral water proofing compound ( ISI marked ) complete all as specified and as directed. |
| 32 | M&L for applying three coats of white wash on newly plastered surfaces of walls including preparation of surfaces complete all as specified and as directed. |
| 33 | M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls over and including a coat of primer complete all as specified and as directed. |
| 34 | M&L for angle iron posts 65x65x6mm thick and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 35 | M&L for compound girder and stanchions, lattice girders, aerial mast, staging for water tanks and the like including caps, bases, splices etc built up from two or more beam or channel section or angles with plates , including all lattice bars, stiffeners, guesset plates etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 36 | M&L for preparation of old decorated surfaces of walls (plastered) by brooming down with steel wire brushing and applying one coat of white wash on wall complete all as specified and as directed. |
| 37 | M&L for preparation of old plastered or unplastered surfaces of external wall by brooming down with steel wire brushing and applying one coat of cement base paint on external wall surfaces complete all as specified and as directed. |
| 38 | M&L for preparation of old painted steel surfaces over 10 cm width/girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 39 | S & F in repairs Providing precast cement concrete louvres and jallies,type B-0, (1:2:4) (using 12.5 mm graded stone aggregate) 25mm thick (measured solid) and setting in cement mortar (1:4),including necessary form work and mould complete all as specified and as directed. |
| 40 | M&L RCC design mix M-25 as in plinth beams, column, lintel, lintel band and gable beams etc including formwork complete all as specified and as directed. Please Enable Macros to View BoQ information |