| 1 | Notes: -(i) Please refer Schedule 'A' Notes of tender documents.(ii) Schedule 'A' Ser No 3.00 to 5.00 are not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only.(iii) In case rate of any item is not quoted by the bidder, the rate for the same item will be considered as zero and no claim in this regard at later date will be entertained. |
| 2 | LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS |
| 3 | Sch 'A' Part-I ( Building works) carried forward from pre-priced Schedule. |
| 4 | Sch 'A' Part-I (A) (Covered Shed works) carried forward from pre-priced Schedule. |
| 5 | Sch 'A' Part-II (Internal Water Supply) carried forward from pre-priced Schedule. |
| 6 | Sch 'A' Part-III (Sec-I) (Internal Electrification) carried forward from pre-priced Schedule. |
| 7 | Sch 'A' Part-IV (Sec-I) (External water supply) carried forward from pre-priced Schedule |
| 8 | Sch 'A' Part-V, Sec-I (External Electrification ) carried forward from pre-priced Schedule |
| 9 | Sch 'A' Part-VI (Sewage disposal Works) carried forward from pre-priced Schedule |
| 10 | Sch 'A' Part-VII (Collection chamber) carried forward from pre-priced Schedule |
| 11 | Sch 'A' Part-VIII (Site Clearance and Earth work) for works covered under Sch 'A' Part-II to VII) carried forward from pre-priced Schedule. |
| 12 | Lump sum price worked out by the contractor for Defective Works as listed in Schedule 'A' Part-XIII brought forward from Pre Priced Schedule. |
| 13 | Sch 'A' Part-III (Sec-II) (Internal Electrification)Note : This schedule is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only. |
| 14 | Lamp holder bracket type with LED lamp 7W, PVC/Polycarbonate type with skirt cap suitable for batten fitting, complete all as specified and directed. |
| 15 | M&L for MCB DB SPN 8 way in sheet metal enclosure 240 volts, 50 Hz, with IP-42 protection, double door and common neutral link all enclosed in standard sheet flush mounting complete all as specified (Make: Havells Cat Part No. DSSDBXO196 or equipment in Schneider, Legrand) |
| 16 | MCB SPN 240 V, 50 Hz, 10 KA, 'C' series of rating 32Amp make : Havells cat Part No.DHMGCSNF032 or equivalent Scheinder/C&S. |
| 17 | 18 Watt DELITE LED NEO decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate,environmental friendly,energy efficient ready to use pack fitting complete.MARE : HEVELLS Cat No LHEXBTP7IN1W018 OR EQUIVALENT OF MAKE AS PER GROUP-II OF APPDX 'E' |
| 18 | Delite plus 22 W decorative ultra slim round LED lighting fixture with extruded polycarbonate, environmental friendly, energy eficient 1x22 W LED type (4 ft) having minimum 2000 lumens with extruded engineering plastic housing polycarbonate diffuser, G-13 polycrabonate end cover, the LES with 120 degree vie angle>120 lumen/watt, lumen maintenance 70% at 50000 hrs colour temperature of 6500 K>70 colour rendering the driver must be integral APFC and constant current type having THD<20% and power factor>0.9 with reverse polarity protection and open circuit protection. Make : Havells Model No LHEXBTP7IN1S022 or equivalent in CG, philips incuding 1x22 watt LED tube. |
| 19 | Supply and Fix 20W LED street light fitting for area illumination energy saving environmental friendly long life LED street light fitting made up of pressure die cast AI housing with high power LED as lighting source and lence embedded PC cover having top opening separate driver compartment with IP 65 protection and impact resisitance of IK07 complete alll as specified and tesing on completion and including GI wall mounting bracket 40 mm dia 1.2 Mtr long incl 30 degree bend with 02 No FI clamps 25 x 3mm size with necessary nut bolts etc. complete all as specified and directed by Engr-in-Charge. MAKE : HAVELLS Cat PART No LHETBXU7PA6S020 or Equivalent in PHILIPS/ CG |
| 20 | Supply and fixing of exhaust fan heavy duty 300mm sweep 1400RPM, single phase including all connection accessories complete all as specified and directed |
| 21 | Supply and fixing of exhaust fan heavy duty 450mm sweep 1400RPM, single phase including all connection accessories complete all as specified and directed |
| 22 | Schedule 'A' Part-IV (Sec-II) (External Water Supply Works)Note : This schedule is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only. |
| 23 | Foot valve heavy duty of size 100mm bore,conforming to IS 4038, ISI Marked, flanged ends including suitable nut bolts, washers, packing sheet, etc complete with necessary arrangements for fixing complete all as specified and directed by Engineer-in-charge. |
| 24 | Foot valve heavy duty of size 80mm bore,conforming to IS 4038, ISI Marked, flanged ends including suitable nut bolts, washers, packing sheet, etc complete with necessary arrangements for fixing complete all as specified and directed by Engineer-in-charge. |
| 25 | Construction of RR masonary staging for over head tank 2.4mtr from ground level PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete and brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius in CM 1:4 with plastering and rendering 15 mm thick on fair faces of brick work or concrete surface in CM 1:4 including applying three coat of white wash including preparation of new surface of wall complete all as specified and directed.(Drawing No. CESZ/TD-1101/2011 Sheet 1/1) |
| 26 | Supply, installation, testing and commissioning of chemical dosing pump CHEMINJECT reciprocating mechanically actuated diaphragm dosing pumps suitable for dosing quantities of liquid products upto 100 LPH all as per manufacturers design and specification complete conforming to IS: 10553 part-3) injector tray,electric motor upto 5 HP , capable to deliver chlorine solution upto 1000gms / hr to the rising main complete all as specified and directed Make RMCO Model No RM18 /Aqua flow Engrs |
| 27 | Supply and installation , testing and commissioning Pumping set openwell submerssible start rated voltage 415V 3 phase 300-415 voltage range frequency 50Hz duty S1 out put KW 1.1 to 22 for three phase out put HP 1.50to 30 for three phase 2800 RPM connection star upto 7.5 HP star delta from 10 HP and pipe size for 1 phase 32 to 50 mm for 3 phase 32 to 100 mm type cast iron body,brass/gun metal impellers at 9 mtr head, 1400 LPM coupled with electric driven motor not less than 5 HP capacity, 415 volts , 50 HZ suitable for 80 mm dia pipe delivery side , 1400 LPM discharge and connectiong with copper conductor single core multistranded pvc sheathed cable of size 6 Sqmm of 6 run drawn in flexible pipe from motor to motor starter inclusive of MC 50x50x50 mm frame of suitabel size mounting on PCC foundation in cement concrete 1:3:6 type C-2, 40mm graded aggregate and grouting with nut, bolts and washers complete. Make: Crompton Greaves Model No OSQ52 /Kirloskar/ HAvells |
| 28 | Supply and installation , testing and commissioning Pumping set centrifugal type cast iron body,brass/gun metal impellers at 80mtr head, 450 LPM coupled with electric driven motor not less than 11 KW/15 HP capacity TEFC , SCR 4 pole 1500 rpm Syn speed 415 V 50 Hz, 3 phase AC supply, 50 Hz , suction and delivery pipe line of size 65x50 mm and connection with copper conductor single core multistranded pvc sheathed cable of size 6 Sqmm of 6 run- 10 RM apporx drawn in flexible pipe from motor to motor starter inclusive of MC 100x100x75 mm frameof suitabe size mounting on PCC foundation in cement concrete 1:3:6 type C-2, 40mm graded aggregate and grouting with nut, bolts and washers complete. Make:Crompton Greaves Model No.MBN15.2 /Kirloskar/Havells |
| 29 | Supply and installation , testing and commissioning Pumping set centrifugal type cast iron body,brass/gun metal impellers at 45mtr head, 1100 LPM coupled with electric driven motor not less than 15 KW/20 HP capacity TEFC , SCR 4 pole 1500 rpm Syn speed 415 V 50 Hz, 3 phase AC supply, 50 Hz , suction and delivery pipe line of size 65x50 mm and connection with copper conductor single core multistranded pvc sheathed cable of size 10 Sqmm of 6 run- 10 RM apporx drawn in flexible pipe from motor to motor starter inclusive of MC 100x100x75 mm frameof suitabe size mounting on PCC foundation in cement concrete 1:3:6 type C-2, 40mm graded aggregate and grouting with nut, bolts and washers complete. Make:Crompton Greaves Model No. MBR20.2 /Kirloskar/Havells |
| 30 | Supply and installation testing and commissioning Pumping set centrifugal cast iron body,brass/gun metal impellers at 45 mtr head, 1100 LPM coupled with electric driven motor not less than 20 HP capapsity and connectiong with copper conductor single core multistranded pvc sheathed cable of size 10 Sqmm of 6 run drawn in flexible pipe from motor to motor starterinclusive of MC 100x100x75 mm frame of Suitable size mounting on PCC foundation in cement concrete 1:3:6 type C-2, 40mm graded aggregate and grouting with nut, bolts and washers complete. Make: Havells/Crompton Greaves/Kirloskar |
| 31 | Supply ,installation,commissioning and testing of diesel engine driven generating set capacity 62.5 KVA ,415 volts with latest CPCB Norms, mounted on common base frame ,1500RPM with silencer pipe (acustic enclosure) protected with asbestos rope independently supported from engine to outside power houseupto 1 mtr ,AVM pads foundations as per manufacure design battery start with suitable size of cable for connecting upto panel board . DG Set should be capable of operating in temperture range (-25* C to + 35*C) fitted with Cold starting kit with and including the following . Make : Cummins / CG KIRLOSKAR/KOELGREEN |
| 32 | A. Prime mover Vertical diesel engine of suitable capacity water cooled closed circuit as per BS-649 or IS-10002 direct injection type turbo charged electric starting system having rated speed 1500 RPM. The DG Set shall be capable of running 24hrs continuously with 10% over loading for one hrs continuously in every 12 hrs as per BS -649. Engine shall be eqipped with with all standrd fitting and mounted on common base frame with following fittings |
| 33 | B. AlternatorAlternator rating 62.5KVA,3 phase,4wire,415 Volts 50C/s supply 0.8 Pfrunning @ 1500 RPM self excited ,self regulated, mounted on strong fabricated steel frame,suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be confirming to BS-2613 or IS -4722 |
| 34 | C. Control Panel Alternator control panel to be canopy mounted with internal copper wiring with copper conductor cable of suitable size for 62.5 KVA alternator 415V,3 phase,4 wire 50Hz fabricated out 1.5mm thick MS sheet painted externally with two coats of synthetic enamel paint over acoat of primer including following accessories (a) Digital AMP, volt, Frequency, KW, KWH, Meters in the Engine controller with Scrollable selector switch (b) CTs of suitable range -01 set (c) MCCB -01 No ( For incoming )as recommended by manufacture (d) Set of Aluminum bus bar suitable capacity (e) Set indicating lamps (f) Set of instumental fuses. |
| 35 | D. Other fittings (i)Battery charger having electric circuit consisting of triodes , capacitor and resistances etc. The battery charger should be able to charge the battery at all times whenever the electric supply given to battery charger through control panel or electric power point.(ii) In built Fuel tank of suitable capacity as per manufacturers instructions capable for12 hrs running of DG Set inside the canopy base with all connecting pipes upto fuel pump and including oil level indicating gauge drain air vent plug etc. |
| 36 | Supply ,installation,commissioning and testing of diesel engine driven generating set capacity 100KVA ,415 volts with latest CPCB Norms, mounted on common base frame ,1500RPM with silencer pipe (acustic enclosure) protected with asbestos rope independently supported from engine to outside power houseupto 1 mtr ,AVM pads foundations as per manufacure design battery start with suitable size of cable for connecting upto panel board . DG Set should be capable of operating in temperture range (-25* C to + 35*C) fitted with Cold starting kit with and including the following . Make Cummins/CG KIRLOSKAR/KOELGREEN |
| 37 | A. Prime mover Vertical diesel engine of suitable capacity water cooled closed circuit as per BS-649 or IS-10002 direct injection type turbo charged electric starting system having rated speed 1500 RPM. The DG Set shall be capable of running 24hrs continuously with 10% over loading for one hrs continuously in every 12 hrs as per BS -649. Engine shall be eqipped with with all standrd fitting and mounted on common base frame with following fittings |
| 38 | B. Alternator Alternator rating 100KVA,3 phase,4wire,415 Volts 50C/s supply 0.8 Pfrunning @ 1500 RPM self excited ,self regulated, mounted on strong fabricated steel frame,suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be confirming to BS-2613 or IS -4722 |
| 39 | C. Control Panel Alternator control panel to be canopy mounted with internal copper wiring with copper conductor cable of suitable size for 100 KVA alternator 415V,3 phase,4 wire 50Hz fabricated out 1.5mm thick MS sheet painted externally with two coats of synthetic enamel paint over acoat of primer including following accessories (a) Digital AMP, volt, Frequency, KW, KWH, Meters in the Engine controller with Scrollable selector switch (b) CTs of suitable range -01 set (c) MCCB -01 No ( For incoming )as recommended by manufacture (d) Set of Aluminum bus bar suitable capacity (e) Set indicating lamps (f) Set of instumental fuses. |
| 40 | D. Other fittings (i)Battery charger having electric circuit consisting of triodes , capacitor and resistances etc. The battery charger should be able to charge the battery at all times whenever the electric supply given to battery charger through control panel or electric power point.(ii) In built Fuel tank of suitable capacity as per manufacturers instructions capable for12 hrs running of DG Set inside the canopy base with all connecting pipes upto fuel pump and including oil level indicating gauge drain air vent plug etc. |
| 41 | Supply ,installation,commissioning and testing of diesel engine driven generating set capacity 125KVA ,415 volts with latest CPCB Norms, mounted on common base frame ,1500RPM with silencer pipe (acustic enclosure) protected with asbestos rope independently supported from engine to outside power houseupto 1 mtr ,AVM pads foundations as per manufacure design battery start with suitable size of cable for connecting upto panel board . DG Set should be capable of operating in temperture range (-25* C to + 35*C) fitted with Cold starting kit with and including the following . Make Cummins/CG KIRLOSKAR/KOELGREEN |
| 42 | A. Prime mover Vertical diesel engine of suitable capacity water cooled closed circuit as per BS-649 or IS-10002 direct injection type turbo charged electric starting system having rated speed 1500 RPM. The DG Set shall be capable of running 24hrs continuously with 10% over loading for one hrs continuously in every 12 hrs as per BS -649. Engine shall be eqipped with with all standrd fitting and mounted on common base frame with following fittings |
| 43 | B. Alternator Alternator rating 125KVA,3 phase,4wire,415 Volts 50C/s supply 0.8 Pfrunning @ 1500 RPM self excited ,self regulated, mounted on strong fabricated steel frame,suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be confirming to BS-2613 or IS -4722 |
| 44 | C. Control Panel Alternator control panel to be canopy mounted with internal copper wiring with copper conductor cable of suitable size for 125 KVA alternator 415V,3 phase,4 wire 50Hz fabricated out 1.5mm thick MS sheet painted externally with two coats of synthetic enamel paint over acoat of primer including following accessories (a) Digital AMP, volt, Frequency, KW, KWH, Meters in the Engine controller with Scrollable selector switch (b) CTs of suitable range -01 set (c) MCCB -01 No ( For incoming )as recommended by manufacture (d) Set of Aluminum bus bar suitable capacity (e) Set indicating lamps (f) Set of instumental fuses. |
| 45 | D. Other fittings (i)Battery charger having electric circuit consisting of triodes , capacitor and resistances etc. The battery charger should be able to charge the battery at all times whenever the electric supply given to battery charger through control panel or electric power point.(ii) In built Fuel tank of suitable capacity as per manufacturers instructions capable for12 hrs running of DG Set inside the canopy base with all connecting pipes upto fuel pump and including oil level indicating gauge drain air vent plug etc. |
| 46 | Supply and fixing installation, commissioning and testing LT panel indoor cubical floor mounted channel type of size not less than (L-2.mxB-0.5xH-1.2m) openable to front and back both side made out of 2mm thick CRCA sheet duly powder coated complete with bus bar 625 Amps rating made of copper strip duly drilled holes for conections and mounted on epoxy based post insulators for 3 phase 4 wire 415V 50Hz power supply system suitable for and including the folowing : Apporved make in Zonal specification |
| 47 | (a) MCCB, 4 Pole,415 volt - 50 Hz 350 Amps 35 KA , 01 Nos as incoming Make C & S Cart Part No CSC5N4 thermal megnetic release, fixed overload, fixed fault or equivaalent in siemen, legrand (MDS)with adjustable magnetic and adjustable thermal release protection - 01 Nos for incoming, Make: Legrand/ABB/Havells(b) MCCB, 4 Pole,415 volt - 50 Hz 200 Amps 35 KA , 02 Nos as outgoing Make C & S Cart Part No CSC5N4 thermal megnetic release, fixed overload, fixed fault or equivaalent in siemen, legrand (MDS)with adjustable magnetic and adjustable thermal release protection - 01 Nos for incoming, Make: Legrand/ABB/Havells(c) MCCB, 4 Pole,415 volt - 50 Hz 150 Amps 35 KA , 02 Nos as outgoing Make C & S Cart Part No CSC5N4 thermal megnetic release, fixed overload, fixed fault or equivaalent in siemen, legrand (MDS)with adjustable magnetic and adjustable thermal release protection - 01 Nos for incoming, Make: Legrand/ABB/Havells(d) Indicator set RYB 1 set of 3 pcs |
| 48 | (e) Digital voltmeter of size 96x96mm range 0 to 500volts of AE Make or equivalent of Make L & T with in built in selector switch 01 set(f) Digital ammeter of size 96x96mm range 0 to 500A of AE Make or equivalent of Make L & T with in built in selector switch complete with CTs of approved ration 01 Set(g) On load changeover switch 4 pole I-O-II 200A-02 Nos Make C & S cat part No ECSCS200DM4CO DM type or equivalent in make L & T, legrand All accessories perwired with suitable size copper conductor cable strip and suitable foundation as per manufactures recommendationNote : (i) Drawing of the panel will be approved by the Engr-in-Charge (ii) Factory testing will be carried by the manufacturer in the presence of Engr-in-Charge,any changes in the design will be in corporated |
| 49 | Supply and fixing installation, commissioning and testing LT panel indoor cubical floor mounted channel type of size not less than (L-2.mxB-0.5xH-1.2m) openable to front and back both side made out of 2mm thick CRCA sheet duly powder coated complete with bus bar 300 Amps rating made of copper strip duly drilled holes for conections and mounted on epoxy based post insulators for 3 phase 4 wire 415V 50Hz power supply system suitable for and including the folowing : Apporved make in Zonal specification |
| 50 | (a) MCCB, 4 Pole,415 volt - 50 Hz 160 Amps 35 KA , 01 Nos as incoming Make C & S Cart Part No IHLASF0100 thermal megnetic release, fixed overload, fixed fault or equivaalent in siemen, legrand (MDS)with adjustable magnetic and adjustable thermal release protection - 01 Nos for incoming, Make: Legrand/ABB/Havells(b) MCCB, 4 Pole,415 volt - 50 Hz 50 Amps 35 KA , 02 Nos as outgoing Make C & S Cart Part No IHLANF0050 thermal megnetic release, fixed overload, fixed fault or equivaalent in siemen, legrand (MDS)with adjustable magnetic and adjustable thermal release protection - 01 Nos for incoming, Make: Legrand/ABB/Havells(c) Indicator set RYB 1 set of 3 pcs(d) Digital voltmeter of size 96x96mm range 0 to 600 volts of AE Make or equivalent of Make L & T with in built in selector switch 01 set |
| 51 | (e) Digital ammeter of size 96x96mm range 0 to 500A of AE Make or equivalent of Make L & T with in built in selector switch complete with CTs of approved ration 01 Set(f) On load changeover switch 4 pole I-O-II 200A-02 Nos Make C & S cat part No ECSCS200DM4CO DM type or equivalent in make L & T, legrand All accessories perwired with suitable size copper conductor cable strip and suitable foundation as per manufactures recommendationNote : (i) Drawing of the panel will be approved by the Engr-in-Charge(ii) Factory testing will be carried by the manufactrer in the presence of Engr-in-charge, any changes in the design will be incrporated |
| 52 | Material and labour for trial bore hole suitable for 200mm bore MS casing pipe in any type of strata including soft/hard rock by DTH/ODES/Rotary combination rig and getting out for upto 26 to 50 mtr depth below ground level Note : The diameter of the bore hole should be sufficient lagre enough for lowering well assembly of 200mm casing pipe and packing of gravel around MS casing from to bottom (03 Nos Bore well) |
| 53 | All as per item No 4.30 above but depth from 51 to 75 mtr below ground level |
| 54 | All as per item No 4.30 above but depth from 76 to 100 mtr below ground level |
| 55 | All as per item No 4.30 above but depth from 101 to 125 mtr below ground level |
| 56 | All as per item No 4.30 above but depth from 126 to 150 mtr below ground level |
| 57 | The development of bore well using 250 PSI compressed air and suitable capacity submersible pump set by pumping muddy water until sand free clear water is obtained from the well or any CGWB approved method complete all as specified and directed. (03 Nos bore well) |
| 58 | Well cap fabricated out of 6mm thick MS sheet for 200mm dia bore pipe in two pieces having 50mm dia hole in centre with external bracket of flat iron of size 100mm*6mm thick complete with nuts, bolts and washers etc. including painting with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and directed. |
| 59 | Yield test with submersible pump for determining the head/ drawn of water per yield of the well by continuously pumping for 16 hours to determine safe pumping yield |
| 60 | Supply, laying/ fixing cable for flat submersible with stranded copper conductor 3 core 1100 volts grade 4 Sqmm cross sectional area confirming to relevant IS complete all as specified and directed.Make: - Finolex/ Plaza/ Havells |
| 61 | Supply and fixing casing cap 200mm dia highly tempered with (MS-AN4Z) grade made out of MS sheet 3 mm thick and fixing with MS clamps 50x6 mm FI with nuts, bolts and washers complete in all respect all as specified and directed. |
| 62 | Strainer Y type conforming to IS Size 80mm (3\\") dia complete all as specified and directed. |
| 63 | Supply, installation, testing and commissioning of Pressure sand filter(vertical) single deck pressure vessels provided with face piping,inlet and out let valves,filter and sand media, under bed plate system, piping and distribution system, fitted with PVC Stariner pressure gauges, manholes, hand holes, air vent system, coagulant feeder, chlorine dosing unit, air compresser (air blower) of suitable capacity for back wash. The unit will conside to cater turbid upto 40 ppm during mansoon while designing.Standard capacity 15000 gal./hr complete all as specified and directed Make RMCO Model No VSM 101530 FP /Aqua flow Engrs/Pearl. |
| 64 | Supply, installation, commissioning and testing LT feeder pillar box, outdoor cubical type, floor mounted, factory made,CPRI approved, fabricated out of 3.15 mm thick mild steel sheet mounted on frame of mild steel angle iron 50 mm X 50 mm X 6 mm, 45 cms above the ground level duly supported and grouted in PCC foundation in PCC (1:2:4), type B-I, using 20 mm graded crushed stone aggregate. LT feeder pillar box shall be totally enclosed weather proof and vermin proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for 415 volts, 3 phase, 4 wire having TPN copper bus bars of 100 Amps rating duly drilled holes for connections, RYB insulated with different color code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs/ gland complete all as specified and directed. and comprissing of following:- (Pump House Panel Open well & submersible pump set) |
| 65 | (a) MPCB TPN 20 Amp, 415V, 50 KA (Short circuit protection) thermal magnetic release - 01 No (Incomer). (b) MPCB TPN 20A 50 KA - 01 No.(outgoing) (c) Digital voltmeter 0-500V - 01 No.(d) Digital Ammeter 0-100 Amp with CT & selector switch - 02 No. (e) Phase Indicator (RYB) set - 01 No.(f) Phase sequence corrector with single phase preventor - 01 No. (g) Low voltage and high voltage tripping system.(h) Fully automatic Star-delta starter 3-phase 415 Volt suitable for 7.5 HP/ 5.5 KW comprising of 4 Pole Main/Delta contactor MNX 32, Star contactor MNX 9 Over laod relay MN2 , overload relay range 6-10 Amps with over load protection relay 50 Hz, single Phase sequence corrector, time relay delay, microprocessor relay , electronic timer - Make: L&T/ Havells/equivalent- 02 Nos (j) Internal wiring of panel board with copper cable of appropriate size single core including control fuses and Cable glands, lugs of suitable size for incoming and out going cables Earthing terminals and cable glands. |
| 66 | Supply, installation, commissioning and testing LT feeder pillar box, outdoor cubical type, floor mounted, factory made,CPRI approved, fabricated out of 3.15 mm thick mild steel sheet mounted on frame of mild steel angle iron 50 mm X 50 mm X 6 mm, 45 cms above the ground level duly supported and grouted in PCC foundation in PCC (1:2:4), type B-I, using 20 mm graded crushed stone aggregate. LT feeder pillar box shall be totally enclosed weather proof and vermin proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for 415 volts, 3 phase, 4 wire having TPN copper bus bars of 100 Amps rating duly drilled holes for connections, RYB insulated with different color code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs/ gland complete all as specified and directed. and comprissing of following:- (Pump House Panel Centrifugal pump set ) |
| 67 | (a) MPCB TPN 63 Amp, 415V, 15 KA (short circuit protection) Thermal magnetic release - 01 No (Incomer). (b) MPCB TPN 63 Amp 15 KA - 01 No.(outgoing) (c) Digital voltmeter 0-500V - 01 No.(d) Digital Ammeter 0-100 Amp with CT & selector switch - 02 No. (e) Phase Indicator (RYB) set - 01 No.(f) Phase sequence corrector with single phase preventor - 01 No. (g) Low voltage and high voltage tripping system.(h) Fully automatic Star-delta starter 3-phase 415 Volt suitable for 20 HP/ 11 KW comprising of 4 Pole Main/Delta contactor MNX70, Star contactor MNX 25 Over laod relay MN5 , overload relay range 14- 23 Amps , 50 Hz, single Phase sequence corrector, time relay delay, microprocessor relay , electronic timer - Make: L&T/ Havells/equivalent - 02 Nos (j) Internal wiring of panel board with copper cable of appropriate size single core including control fuses and Cable glands, lugs of suitable size for incoming and out going cables Earthing terminals and cable glands. |
| 68 | M&L for best quality pea gravel of mixed siz varing 4 mm to 8 mm and packing the same around casing pipe from top to filter portion in the atmost top complete all as specified and directed. |
| 69 | Schedule 'A' Part-V (Sec-II) (External Electrification)Note : This schedule is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only. |
| 70 | Provision of new generation energy saving & enviromental friendly long life versatile pressure die-cast alumininum roadway laminaire with high power as 80W LED 6000K suitable for pole dia 54mm maximum complete all as specified and directed by Engr-in-Charge. Make : Havells Cat part No. LHETAXU7PN6J060 or equivalent Bajaj/Philips |
| 71 | Provision of bracket for fixing of street light fittings bend to shape, made out of 32mm dia GI pipe light grade upto 1.5 mtr long fixed with and including clamps made from Flat iron of size 40x5mm, MS clamps bolt, nuts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as directed |
| 72 | PVC line separators of various types lines 4 way/3 way/2 way complete all as specified and directed. |
| 73 | Supply and fix junction box IP 66 protected out door for outdoor installation of size 167x185x32mm with provn of one single pole MCB SP 6 Amp for connecting of security light complete all as specified and directed. Please Enable Macros to View BoQ information |