| 1 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 300Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed .Havells/Paragon/SCI/Polycab/Plaza |
| 2 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 240Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza |
| 3 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 150Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza |
| 4 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 120Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza |
| 5 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 70Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza |
| 6 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 50Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza |
| 7 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 25Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza |
| 8 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 16Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza |
| 9 | Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 10Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza |
| 10 | Excavation in trenches in soft/loose soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 11 | Excavation in trenches in any type of soil not exc 1.5 mtr wide and exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed. |
| 12 | Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. |
| 13 | Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 14 | Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation complete all as specified and directed. |
| 15 | Supply and laying PCC cable cover of size 250 x150 x 40 mm, laid in trench flat for protection of cable complete all as specified and directed by Engr in charge. |
| 16 | Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 63mm, inner dia 50 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 105 mm, inner dia 95 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge. |
| 18 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge. |
| 19 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge. |
| 20 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge. |
| 21 | Supply & fixing GI tube 50 mm bore light grade with all fittings for laid in trenches/fixed along with poles/walls & floor of buildings etc under crossing of road for protection of cables including demolition and taking down of the old existing pipe including repair of the floor/wall and matching with the existing surface if required complete as directed by Engineer-in-Charge. |
| 22 | S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed. |
| 23 | M&L for painting of steel tubuler 11/9 mtr poles any type complete incl flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint (Ist quality of manufacturer )and also including numbering of poles with white paint are located on different locations complete all as specified and directed . |
| 24 | M & L for cutting of road up to 0.75m deep suitable for laying underground cable/MS tubes of any size/dia including GI pipe of 50mm dia and making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50mtrs complete all as specified and directed. |
| 25 | Trimming of tree branches touching to over head lines, upto 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearence of HT/LT pole and sub station premises all as directed by Engg-in-charges. Note: (i) Trimming of all branches of trees falling under one span between two pole shall be shall be considered as as one span only. (ii) Contractor have to arrange all T&P , safty equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishapning occured due to negelency of safty aspects. |
| 26 | Trimming of tree branches touching to over head lines, upto 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearence of HT/LT pole and sub station premises all as directed by Engg-in-charges. Note: (i) Trimming of all branches of trees falling under one span between two pole shall be shall be considered as as one span only. (ii) Contractor have to arrange all T&P , safty equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishapning occured due to negelency of safty aspects. |