| 1 | Taking down existng unserviceable street/security light fittings along the perimeter wall/fencing by using ladder in hill areas, HPSV/HPMV/MH/Tube light/LED fittings of any capacity any type from pole/wall afte disconnection the connecting wires , carrying to store yard for necessry repair/replacement of spares etc complete all as specified and as directed. |
| 2 | Refixing only the street light fittings after repair along the perimeter wall/fencing by using ladder in hill areas, obtained from item No.01 here in before incuding making connections with cables and testng complete all as specified and as directed. Note for Item no 1 &2 : (a) Any new spares including cable required to be replaced shall be measured and paid separately. (b) Necessary T&P, Safety Belt, Aluminium Ladder, Vehivle etc reqd for taking down will be arranged by the Contractor and cost for the same shall deemed to be included in the Quoted Unit Rate. |
| 3 | Supply and laying, of XLPE under ground insulated,,armoured,heavy duty LT 1100 volts 16 Sqmm 4 core grade cable with aluminium conductor ISI marked, laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands complete all as directed incl taking out the old burnt out cables all as specified and directed by Engr-in-Charge. |
| 4 | Description all as per ser item No 3.00 above but of size 4 core 25 Sqmm |
| 5 | Description all as per ser item No 3.00 above but of size 3.5 core 35 Sqmm |
| 6 | Description all as per ser item No 3.00 above but of size 3.5 core 50 Sqmm |
| 7 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed. |
| 8 | Excavation in trenches exceeding 1.5 M wide and exceeding 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable all as specified and directed. |
| 9 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed. |
| 10 | Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc . 1.5M above the starting point |
| 11 | Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness only measured and paid |
| 12 | M & L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed. |
| 13 | M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for making pole base and stay foundation. |
| 14 | M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole fixing all as directed. |
| 15 | M & L for PCC 1:2:4 type B 1 using 20 mm graded stone aggregate including use and waste of form work for pole coping/ any description all as directed. |
| 16 | Dismantling old and unserviceable pre stressed concrete /Steel poles any type including breaking cement concrete complete, Supply and fix with Material and erection of steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-55 ( 11mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and derected by engir-in charge. (note- Excavation and PCC Included in same item ) |
| 17 | S & F in repairs Cable Junction Box/Distribution Board IP 65 with metric knockouts for cable entry of size 10 to 50 sq mm x 4 core including fastening clamp with LT pole, of suitable size, with locking arrangements including with terminals TPN strip, complete all as specified and directed. |
| 18 | M&L for tube light grade galvanised with all fittings for cable protection fixed with poles of 50 mm bore including complete all as specified and directed. |
| 19 | M&L for Sub Main wiring using FR Insulated unsheathed, multistrand copper conductor FR-LS PVC cable 2 runs of size 2.5 sqmm for phase and neutral and 1.5 Sq mm for earthing. drawn through rigid PVC conduit 20 mm dia with clamps for fixed on pole for connection from junction box to light fittings / switch complete all as directed by Engr-in-Charge. Note: Two runs of cable for phase / neutral and one run of cable for earth incl conduit will be measured and paid as one unit length. |
| 20 | M&L GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.20 Metre long bent to shape as per specified for fixing Street Light Fitting including suitable size of clamps and applying Two coats of Aluminium Paint over a coat of Aluminium Primer including taking down old unserviceable GI Pipe Bracket with clamps, complete all as specified and as directed. |
| 21 | M&L in repairs for Earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia light grade protection pipe and salt etc and connected to earthing test point incl necessary earth work complete all as specified and as directed. |
| 22 | M & L in repair Electronic Driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 150 Watt, as per existing make and type complete all as specified and directed. |
| 23 | All as item no 22 above but for LED Light Fitting of capacity 100/120 Watt. |
| 24 | All as item no 22 above but for LED Light Fitting of capacity 60/72/75 Watt. |
| 25 | All as item no 22 above but for LED Light Fitting of capacity 45 Watt. |
| 26 | M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 2.5 sqmm including takingdown existing unserviceable wire complete all as specified and directed by Engineer-in-Charge. |
| 27 | M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 6 sqmm including takingdown existing unserviceable wire complete all as specified and directed by Engineer-in-Charge. |
| 28 | M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 10 sqmm including takingdown existing unserviceable wire complete all as specified and directed by Engineer-in-Charge. |
| 29 | M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 16 sqmm including takingdown existing unserviceable wire complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and fix LED flood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed by Engineer-in-Charge. |
| 31 | Description all as per ser item No 30.00 above but of 200 Watts complete all as specified and directed by Engineer-in-Charge. |
| 32 | Description all as per ser item No 30.00 but of 250/240 Watts complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fix LED street light fitting 45 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket duly removing existing unserviceable street light fitting complete all as specified and directed by Engineer-in-Charge. |
| 34 | Description all as per ser item No 33.00 but of 60 watt. |
| 35 | Description all as per ser item No 33.00 but of 70 watt. |
| 36 | Description all as per ser item No 33.00 but of 90 watt. |
| 37 | Description all as per ser item No 33.00 but of 120 watt. |
| 38 | Supply and fix LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection 40 watts with high efficiency long life LEDs In-built replaceable electronic driver complete fixing on existing bracket duly removing existing unserviceable light fitting complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fix post top light/garden light fitting pin type holder, pvc round or ovel shape of size 6' dia complete with LED bulb pin type 15 watt along with .6 mtr pole and fixing arrangement on existing pole/bracket duly removing existing unserviceable light fitting/pole complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and fix Integral LED aviation light luminaire comprising of yellow painted LM6 aluminium alloy housing polycarbonate enclosure including takingdown existing unserviceable aviation light fitting complete all as specified and directed by Engineer-in-Charge.Make: Bajaj / Crompton Greaves/ Havells/Wipro |
| 41 | Taking down in repair of high mast light, Hot dip galvanised Mast 15/16meter high and Luminaires carriage duly opening of nut & bolt at bottom with the help of Hydra/Crane for repair/replacement of old UNSV Winch and steel wire ropes (as per existing) complete with ratchet, limit switches etc as per standard engineering practice to avoid falling of carrirer during raising or lowering and re-installation, testing at site and comissioning after satifactorily repair complete all as specified and directed. |
| 42 | M & L for Painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia all as directed by Engr in charge. |
| 43 | Taking down of old unserviceable street light timer switch board of any type and Supply, installed test and commissioning street light distribution boards 12 KW, Digital 24 Hour capacity, 3 pole, 415 volt, made out of CRCA Sheet Steel with front openable door fitted with necessary hinges, door locking by Panel lock and provision for Pad Locking duly phosphatized and powder coated and conforming to IP 54 degree of protection, complete suitable for wall mounting/ pole mounting with suitable clamps, nuts & bolts etc, internally pre-wired with suitable guage of copper wires and connecting up all incoming and outgoing cables with suitable cable glands, lugs, nuts, bolts and washers complete suitable for accommodating and including provision of following switchgears/ components :-a) Incoming MCB 63 Amp TPN - 01 No.b) 3 pole contactor 65 Amp - 01 No.d) Timer switch Digital type, 24 Hour - 01 No.e) Auto/Manual selector Switch - 01 No. |
| 44 | Taking down of old unserviceable street light timer switch board of any type and Supply, installed test and commissioning street light distribution boards max load 6 KW, Digital 24 Hour capacity, 230 volt, made out of CRCA Sheet Steel with front openable door fitted with necessary hinges, door locking by Panel lock and provision for Pad Locking duly phosphatized and powder coated and conforming to IP 54 degree of protection, complete suitable for wall mounting/ pole mounting with suitable clamps, nuts & bolts etc, internally pre-wired with suitable guage of copper wires and connecting up all incoming and outgoing cables with suitable cable glands, lugs, nuts, bolts and washers complete suitable for accommodating and including provision of following switchgears/ components :-a) Incoming MCB 40 Amp SPN - 01 No.b) 3 pole contactor 32 Amp - 01 No. d) Timer switch Digital type, 24 Hour - 01 No.e) Auto/Manual selector Switch - 01 No. Make: Havells cat No IHXSS01060 or equivalent in L&T/HPL/Indo asian. |
| 45 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum Please Enable Macros to View BoQ information |