| 1 | Excavation in trench not exceeding 1.5 M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed. |
| 2 | Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in road/hardstanding and getting out complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. |
| 4 | Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed. |
| 5 | Demolition of cement concrete (un-reinforced) not exc 15cm thick in ground floor and paving (below or above ground level) complete all as specified and directed. |
| 6 | M & L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and directed. |
| 7 | M & L PCC 1:2:4 type B-2 using 20 mm graded stone aggregate as in surface channels and drains etc complete all as specified and directed. |
| 8 | M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection or similar places, laid in alternate bays, surface finished even and fair without using extra cement complete all as specified and directed. |
| 9 | M & L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed. |
| 10 | M & L 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth using without extra cement complete all as specified and directed. |
| 11 | M & L for heavy duty coloured ceramic floor tiles of size 300 x 300x 10 mm thick, suitable for high traffic external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.(MAKE : JOHNSON, Model : ENDURA or equivalent model in other makes listed in the tender) |
| 12 | M&L Chequered cement concrete tiles 30cm x30cm x 25mm thick,set, jointed and pointed in neat with grey cement pigment slurry in floors including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 13 | Taking out of interlocking paver block, any shape or size and Re-laying the same after removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed.(NOTE: Sand, if required for correction of cushioning level will be measured and paid seperately. Replacement of broken paver block shall be paid seperately as \\"Supply only\\") |
| 14 | M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 15 | Supply and laying 60 mm thick factory made chamfered edge precast glazed cement concrete paver block of M-35 grade confirming to IS 15658-2006 with approved colour, design & pattern as in footpath,Parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.(NOTE: Cost of sand cushioning is deemed to be included |
| 16 | Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 17 | M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring benching to drain, coping, etc and the like edge slightly rounded or chamfered including necessary use and waste of form work complete all as specified and as directed. |
| 18 | Dismantling of 100mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and as directed . |
| 19 | Dismantling of 150 mm bore cast iron (sand cast) soil, waste or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required all as specified and as directed . |
| 20 | S&F 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and directed (Note : Earthwork to be measured and paid separately). |
| 21 | S&F 150 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints fixed on floor or trenches complete all as specified and directed (Note : Earthwork to be measured and paid separately). |
| 22 | S&F 100 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints fixed on wall complete all as specified and directed |
| 23 | S&F 150 mm dia Cast soil waste and vent pipes in any length with or without ears with cement joints fixed on wall complete all as specified and directed |
| 24 | S&F in repair 100mm CI bends (any radius),diminishing pieces or tapers (larger bore measured) any radius with oval access doors complete all as specified and directed |
| 25 | S&F in repair 150mm CI bends any radius complete all as specified and directed |
| 26 | S & F in repair PVC (SWR) pipe 75 mm bore single socketed in any length with rubber ring, fixed on wall complete all as specified and directed. |
| 27 | S & F in repair PVC (SWR) pipe 110 mm bore single socketed in any length with rubber ring, fixed on wall complete all as specified and directed. |
| 28 | S & F in repair PVC bend 110 mm borel complete all as specified and directed. |
| 29 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 150 mm set in cement mortar complete all as specified and directed. |
| 30 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 200 mm set in cement mortar complete all as specified and directed. |
| 31 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 300 mm set in cement mortar complete all as specified and directed. |
| 32 | Supply and laying 150 mm bore reinforced concrete pipe of Class NP-2, with collars, laid and jointed complete all as specified and as directed by the Engineer-in-Charge. |
| 33 | Supply and laying 200 mm bore reinforced concrete pipe of Class NP-2, with collars, laid and jointed complete all as specified and as directed by the Engineer-in-Charge. |
| 34 | Supply and laying 300 mm bore reinforced concrete pipe of Class NP-2, with collars, laid and jointed complete all as specified and as directed by the Engineer-in-Charge. |
| 35 | M/L for PCC (1:3:6) type C2 using 40mm graded broken stone aggregates for bed concrete to drain pipe packing under haunching for sides for 100 mm dia pipe lines complete all as specified and as directed. |
| 36 | M/L for PCC (1:3:6) type C2 using 40mm graded broken stone aggregates for bed concrete to drain pipe packing under haunching for sides for 150 mm dia pipe lines complete all as specified and as directed. |
| 37 | M/L for PCC (1:3:6) type C2 using 40mm grades broken stone aggregates for bed concrete to drain pipe packing under hunching for sides for 200 mm dia pipe lines complete all as specified and as directed. |
| 38 | M/L for PCC (1:3;6) type C2 using 40mm graded broken stone aggregates for bed concrete to drain pipe packing under haunching for sides for 300 mm dia pipe lines complete all as specified and as directed. |
| 39 | Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate), finished smooth and reforming benching for 100mm bore pipe as required and as directed by the Engineer-in-Charge. |
| 40 | S & F as in repair RCPC (Reinforced Cement Polymer Concrete) grating slab on size 1200mmX450mmX75mm thick fixed in proper position complete all as specified and directed. |
| 41 | S & F as in repair RCPC (Reinforced Cement Polymer Concrete) grating slab on size 900mmX450mmX75mm thick fixed in proper position complete all as specified and directed. |
| 42 | S & F as in repair RCPC (Reinforced Cement Polymer Concrete) grating slab on size 600mmX450mmX75mm thick fixed in proper position complete all as specified and directed. |
| 43 | Taking down cement plaster on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 44 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed. |
| 45 | M&L for 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished rendering surfaces even and smooth (without using extra cement) complete all as specified and directed. |
| 46 | M & L two coats of cement based paint on newly plastered surface of wall including preparation and one coat of chalk white of serfaces complete all as specified and directed. |
| 47 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 48 | M&L brick work with Fly ash bricks old size brick straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 49 | M&L brick work with Fly ash bricks' old size brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified and directed. |
| 50 | S &F as in repair cast iron Grade FG 150 grating, railing, frame manhole cover fire and stoot doors, dompers, stop valve box and similar articles etc (weight exc 3 Kg each ) including frame different size fixed in concrete cover as directed by Engr in Charge. |
| 51 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. |
| 52 | M&L non skid ceramic colour tiles of area of each tile exc .06 Sqm but n exc exc .11 Sqm and 6 to 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 15 mm thick screed bed cement mortar 1:6 complete all as specified and directed. all as specified and directed . |
| 53 | M&L non skid ceramic colour tiles/dark colour of area of each tile exc .18 Sqm but n exc exc .38 Sqm and 8-10 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement complete including 15 mm thick screed bed cement mortar 1:6 complete all as specified and directed. all as specified and directed . |
| 54 | M&L non skid ceramic colour tiles of area of each tile exc .11 Sqm but n exc exc .18 Sqm and 6 to 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 55 | Supply and fix non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and incl 10 mm rendering in CM 1:3 complete all as directed. |
| 56 | Supply and fix non skid ceramic coloured tiles 8 to 10 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n exc 0.36 sqm in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and incl 10 mm rendering in CM 1:3 complete all as directed. |
| 57 | M & L glazed ceramic colour tiles size 450 mm x 300 mm x 6 to 7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match including10 mm thick rendering of mortar as in backing coat of tiles on fair face of brick wall or concrete surface in cement mortar 1:4 complete all as specified and directed. |
| 58 | Dismantling of post struts (wood,steel or RCC )any section incl Taking out embedded portion in concrete and making good disturbed ground all as specified and directed |
| 59 | Site clearance around the fencing/ wall 1.5 mtr both side complete all as specified and directed. |
| 60 | Excavation in post holes each n exc 0.5 cum getting out returning filling in and removing earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50m and making good surface as in soft /loose soil. |
| 61 | S&F Mild steel angle iron as posts and struts in fencing including cutting tops to shape as directed, drilling hole including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E 165 complete all as specified and directed |
| 62 | Supply only chain link fenching of size 75x75 mm mesh of cages with 3.15 to 4 mm dia Mild Steel Galvanised Wire, complete all as specified and as directed. |
| 63 | Fixing only Chain Link Fencing 75X75mm Mesh or Cages with 3.15 to 4 mm dia Mild Steel Galvanised Wire lapped, Straining and Binding with including Mild Steel Wire (annealed) not less than 0.9 mm dia, complete all as specified and as directed. |
| 64 | S&F 4 mm dia PVC Coated galvanised mild steel chain link fencing of mesh size 50x50 mm fixed with string bolts includinh provn of binding wire etc complete all as specified |
| 65 | Re-Fixing only 4 mm dia PVC Coated galvanised mild steel chain link fencing of mesh size 50x50 mm fixed with string bolts includinh provn of binding wire etc complete all as specified |
| 66 | M&L Mild Steel Flat as Bands, etc. to Fencing Post with Ends of Bar shouldered and/or riveted or forged into Spikes, Framed Guard Bars and Similar Work, etc. conforming to Fe-410-0 or Fe-310-0 including all necessary drilling, bolting or riveting, etc., complete all as specified and as directed. |
| 67 | M&L Mild Steel Screw Bolts (Machine Made) with Hexagonal Head at one End and screwed the other Ends, each screwed End to be fitted with Washers and One Hexagonal Nut, diameter of Shank 5 to 10mm Length of Bolt exc. 100mm but not exc. 150mm, complete all as specified and as directed. |
| 68 | S&F MS round bar Fe-410-W(Gde E-250) for holding chain link fencing nibs etc with fencing posts complete all as specified and directed. |
| 69 | M & L preparation of new surface & applying two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces exc 10 cm girth complete all as specified and directed. |
| 70 | M & L PCC (1:3:6) type C2 (using 40 mm graded aggregate) as in filling and mass concrete etc complete all as specified and directed. |
| 71 | S&F in repair 35mm precast cement concrete type B0 1:2:4 using (12.5mm graded stone aggregate louvers and jallies including all mouldings set in CM 1:4 complete all as specified and directed. |
| 72 | S&F in repair 45 mm precast cement concrete type B0 1:2:4 using (12.5mm graded stone aggregate louvers and jallies including all mouldings set in CM 1:4 complete all as specified and directed. |
| 73 | M & L for Disconnecting existing water tanks capacity exc 500 ltr n exc 1000 ltr , setting aside (or lowering if required) for cleaning,repairs, leaning, etc. and hoisting using cleaning agents (chemical coumpound) if required all as specified and directed. |
| 74 | M & L for Disconnecting existing water tanks capacity exc 1000 ltr n exc2000 ltr , setting aside (or lowering if required) for cleaning,repairs, leaning, etc. and hoisting using cleaning agents (chemical coumpound) if required all as specified and directed. |
| 75 | S&F 1000 Liter Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed |
| 76 | S&F 2000 Liter Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and didrected |
| 77 | S&F 20 mm dia Ball brass valves,high pressure,with polythene float and flynut complete,screwed for iron pipe or brassferrule complete all as specified and directed. |
| 78 | M & L for Disconnecting existing water tanks capacity exc 250 ltr n exc 500 ltr , setting aside (or lowering if required) for cleaning,repairs, leaning, etc. and hoisting using cleaning agents (chemical coumpound) if required all as specified and directed. |
| 79 | M & L for Disconnecting existing water tanks capacity exc 500 ltr n exc 1000 ltr , setting aside (or lowering if required) for cleaning,repairs, leaning, etc. and hoisting using cleaning agents (chemical coumpound) if required all as specified and directed. |
| 80 | M & L for Disconnecting existing water tanks capacity exc 1000 ltr n exc2000 ltr , setting aside (or lowering if required) for cleaning,repairs, leaning, etc. and hoisting using cleaning agents (chemical coumpound) if required all as specified and directed. |
| 81 | Cleaning of sewage line of 450mm bore by mechanically operated pump including dewatering, desilting and well flushing the line with water complete as directed by the Engineer-in-Charge. ( Note: Sewage line clean by diesal runing vehicle mounting hydraulic operated high pressure suction cum jetting machine ) |
| 82 | Cleaning of sewage line of 300mm bore by mechanically operated pump including dewatering, desilting and well flushing the line with water complete as directed by the Engineer-in-Charge. ( Note: Sewage line clean by diesal runing vehicle mounting hydraulic operated high pressure suction cum jetting machine ) |
| 83 | Cleaning of sewage line of 200 mm bore by mechanically operated pump including dewatering, desilting and well flushing the line with water complete as directed by the Engineer-in-Charge.( Note: Sewage line clean by diesal runing vehicle mounting hydraulic operated high pressure suction cum jetting machine ) |
| 84 | Cleaning of sewage line of 150 mm bore by mechanically operated pump including dewatering, desilting and well flushing the line with water complete as directed by the Engineer-in-Charge.( Note: Sewage line clean by diesal runing vehicle mounting hydraulic operated high pressure suction cum machine ) |
| 85 | Cleaning of sewage line of 450mm bore manually (by pushing a piece of bamboo split, tied with gunny bags at one end from one manhole to another manhole) or by pump including dewatering, desilting and well flushing the line with water complete as directed by the Engineer-in-Charge. |
| 86 | Cleaning of sewage line of 300mm bore manually (by pushing a piece of bamboo split, tied with gunny bags at one end from one manhole to another manhole) or by pump including dewatering, desilting and well flushing the line with water complete as directed by the Engineer-in-Charge. |
| 87 | Cleaning of sewage line of 200 mm bore manually (by pushing a piece of bamboo split, tied with gunny bags at one end from one manhole to another manhole) or by pump including dewatering, desilting and well flushing the line with water complete as directed by the Engineer-in-Charge. |
| 88 | Cleaning of sewage line of 150 mm bore manually (by pushing a piece of bamboo split, tied with gunny bags at one end from one manhole to another manhole) or by mechanically operated pump including dewatering, desilting and well flushing the line with water complete as directed by the Engineer-in-Charge |
| 89 | Cleaning of sewage line of 100 mm bore manually (by pushing a piece of bamboo split, tied with gunny bags at one end from one manhole to another manhole) or by mechanically operated pump including dewatering, desilting and well flushing the line with water and testing on completion complete as directed by the Engineer-in-Charge. |
| 90 | Cleaning of blocked water closet (of any type / pattern) including connected CI pipe line (of any bore) up to 1st manhole blocked nahni / floor trap (of any size /type), sink / urinal / wash- hand basin including connected GI / CI pipe line (of any bore) up to gully trap / 1st manhole as directed by the Engineer-in-Charge. Note:-(Attend Day to Day Complaints through complaints cell of MES by manually and Complaints shoulde be attend within 24 hours) directed by the Engineer-in-Charge. |
| 91 | Cleaning of manhole chamber of depth up to 1.0 metre each, by taking out accumulated sludge, silt, mud etc and removing the same at a distance not exceeding 50 metre (where directed), washing and well flushing of the manhole chamber with water complete as directed by the Engineer-in-Charge. |
| 92 | Cleaning of manhole chamber of depth exceeding 1 metre but not exceeding 2.5 metre each, by pumping out deposited water, taking out accumulated sludge, silt, mud etc and removing the same at a distance not exceeding 50 metre (where directed), washing and well flushing of the manhole chamber with water complete as directed by the Engineer-in-Charge. |
| 93 | Cleaning of manhole chamber of depth exceeding 2.5metre but not exceeding 3.5 metre each, by pumping out deposited water, taking out accumulated sludge, silt, mud etc and removing the same at a distance not exceeding 50 metre (where directed), washing and well flushing of the manhole chamber with water complete as directed by the Engineer-in-Charge. |
| 94 | Cleaning of existing covered / uncovered (partly / semi or fully filled up) drain, of any opening width and depth by removing and re-fixing of cover-slab (wherever applicable) taking out accumulated silt, mud, earth, rubbish, vegetation etc from the drain and removing the same at a distance exceeding 500 metre but not exceeding 1 Kilometre where directed, washing of the drain with water complete all as directed by the Engineer-in-Charge. |
| 95 | Taking up old manhole cover with frame (heavy duty) and raising / re-fixing in proper position, set in cement mortar 1:3 and haunching with PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) concrete surround finished even and smooth without using extra cement all as directed by the Engineer-in-Charge. |
| 96 | Taking up/down plants or vegetation groth wall upto roof level by means of cutting hole into brickwall and making good the surface of dismantled portion (not exc 150 Sqm cm superfical area and not exc one brick depth) using bricks bats / aggragate and plastering in cement mortar (1:4) to distributed portion and applying two coat of cement base paint to match the existing surfaces up to forth floor complete all as specified and directed by Engr in Charge. |
| 97 | Demolition of cement Concrete(reinforcement cut as required to facilitate demolation) Roof, floors (other than ground floors), beams, staircase, landing, chajjas and similar suspended work complete all as specified and directed. |
| 98 | M & L RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall,beam and columns in floor, roof landing,, balconies,conopies, deck slab and shelves etc complete all as specified and directed. |
| 99 | M & L providing pre-cast cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in landing, cover slab for manholes etc, chullah, hoods, chajjas, water trough, mangers, shelves and similar articles with plan face including chamfered weathering, throating etc including necessary use and waste of form work complete all as specified and as directed. |
| 100 | S & F mild steel deformed bar 8 to 10 mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 101 | S & F in repairs vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete all as specified and directed. |
| 102 | S & F in repair 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve and handle including bracket and flush pipe complete all as specified and directed. |
| 103 | S&F in repairs vitreous china (coloured) wash down water closet pan (pedestal pattern) with 'P' or 'S' trap front or back inlet, fixing bolts (except flushing cistern and flush pipe) incl plastic water closet seat cover (white) and mild steel chromium plated or aluminium hinging device complete all as specified and directed. |
| 104 | S&F Mono block water pressure pump set of capacity 0.50 HP single phase , discharge range 36-60 Lpm , working in voltage range 220-240 V with operating pressure range 1.4 -2.4 (Bar) complete including with closed discharge valve and connected fittings complete all as specified and as directed . |
| 105 | S&F in repair Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed.(Make : JAQUAR, Cat No: CON-59KN / PARRYWARE, Cat No: G1453A1 / ESS ESS, Cat No: C-206 / CERA, Model: OCEAN / PRAYAG, Cat No: 9210 / HINDWARE, Cat No: F330043) or equivalent make specified in tender. |
| 106 | Supply and fix, as in repair, 15 mm bore bib taps, fancy type, chromium plated long neck cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified. |
| 107 | Supply and fixed fancy type Pillar taps, cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete al as specified and directed. |
| 108 | S&F in repair Chromium plated brass Wall mixer, concealed type, with concealed body, with overhead shower arrangement fixed with 15 mm bore Iron pipe including taking down existing mixer complete all as specified and directed. (Make : Jaquar, Cat No : CON-273KNUPR / PRAYAG, Cat No: 9275 / CERA, Model: OCEAN / PARRYWARE, Cat No: G1417A1 / HINDWARE, Cat No: F200020 / ESS ESS, Cat No: C-216) or equivalent make specified in tender. |
| 109 | S&F in repair 15mm bore chromium plated two way bib cock with flange, fancy type complete all as specified and as directed.(Make : Ess Ess, Cat No: C-203 / JAQUAR, Cat No: CON-041KN/ PARRYWARE, Cat No: G1434A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9212/HINDWARE, CAT No: F330004CP) or equivalent make specified in tender. |
| 110 | S&F in repair chromium plated Hand shower (health faucet), brass body with 1.2 metre long flexible tube in chrome finish with wall hook complete all as specified and directed.(MAKE : JAQUAR, Cat No : ALD-573/ PARRYWARE, Cat No : T9941A1 / ESS ESS, Cat No: C-232D / CERA, Cat No: F8030401AB / HINDWARE, Cat No: F160002) or equivalent make specified in tender. |
| 111 | S&F in repair various china coloured flat back counter top wash hand basin of size 560mm x 430mm incl providing 32mm dia CP wasted coupling,CP bottle trap bracket, 32mm dia PVC waste pipe including taking down/out unserviceable Wash Hand Basin and making all necessary connections as di rected by Engr-in-Charge. |
| 112 | S&F in repair various china white flat back counter down wash hand basin of size 560mm x 430mm incl providing 32mm dia CP wasted coupling,CP bottle trap bracket, 32mm dia PVC waste pipe and making all necessary connections, fixed as directed by Engr-in-Charge. |
| 113 | S&F in repair vitreous china floor mounted coupled closet (Pedestal pattern) coloured including low level vitreous china valveless syphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, PVC white coloure seat cover and connecting fittings including taking down existing water closet complete all as specified and directed.(Make : PARRYWARE, Model : Cascade NXT / CERA, Model : CLAIR / HINDWARE, Model: CONSTELLATION or equivalent make specified in tender. |
| 114 | S&F in repair glass shelf 450/600 mm with brass brackets, as in repair complete all as specified and directed. (Make: PRAYAG, Cat No: BEA-44 / JAQUAR, Cat No: ACN-1173 / PARRYWARE, Cat No: T6010A1 / CERA, Cat No: F5005102) or equivalent make specified in tender. |
| 115 | S&F in repair CP bottle trap with internal portion 32mm size with 190mm long wall connection pipe complete all as specified and directed(Make: JAQUAR, Cat No: ALD-769L250x190 / ESS ESS, Cat No: C-231C / HINDWARE, Cat No: F850003 / CERA, Cat No: F8060302/ PRAYAG, Cat No: BEA-26) or equivalent make specified in tender. |
| 116 | S & F 10.0 mm thick Toughned glass good quality as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes as required complete all as specified and directed. |
| 117 | S&F 15 mm bore Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm125gms) All as specified and directed. |
| 118 | M & L two coats of cement based paint on old surface of wall including preparation complete all as specified and directed. |
| 119 | M & L one coat of oil bound distemper on old plastered surface of wall including preparation one coat of chalk white on wall by brush and finish with roller complete all as specified and directed. |
| 120 | Material & labour for preparing old exterior emulsion paint surfaces of walls by washing, rubbing down stopping of painted surfaces and applying one coat of exterior emulsion paint weather coat, complete all as specified and as directed. |
| 121 | Material & labour for preparing old exterior emulsion paint surfaces of walls by washing, rubbing down stopping of painted surfaces and applying two coat of exterior emulsion paint weather coat over one coat of primer over wall care putty avg thickness 1-2 mm, complete all as specified and as directed. |
| 122 | Cleaning of debris,broken concrete,tiles,buliding materials,mud, earth, rubbish, vegetation etc from the cantonment area and removing the same outh side of MOD land complete all as directed by the Engineer-in-Charge. |
| 123 | Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ. Please Enable Macros to View BoQ information |