| 1 | Surface dressing n exc 15 cm deep getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in in soft/loose soil complete all as specified and as directed. |
| 3 | Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in in hard/dense soil complete all as specified and as directed. |
| 4 | Excvation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose of soil complete all as specified and as directed. |
| 5 | Excvation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense of soil complete all as specified and as directed. |
| 6 | M&L for Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) n exc 1.5 mtr including getting out and disposal of excavated earth in hard dense soil and .lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge |
| 7 | All as per item No. 6 here in befoe, but depth exc. 1.5m but n. exc. 3.00 m. |
| 8 | M & L for hand packing of broken stone ( any thickness) at back of the retaining wall etc and raising and lowering to required level complete all as specified and directed. |
| 9 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling, mass concrete, sub-base & apron etc complete all as specified and directed. |
| 10 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate) as in foundation & mass concrete bed of manhole etc. complete all as specified and directed. |
| 11 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate) as in bed of drain pipes, laid to falls including packing under, haunching against the sides of pipes after they are laid, jointed and tested for 150mm bore pipe complete all as specified and directed. |
| 12 | M&L for cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundation, filling, mass concrete including haunching etc complete all as specified and directed. |
| 13 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 14 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc. |
| 15 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for Columns, pillars, piers, posts and struts etc. complete all as specified and as directed. |
| 16 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchion , Circular on plan or etc. complete all as specified and as directed. |
| 17 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for beams, cantilevers, bressummers, lintels, lintel beam, roof beams etc. complete all as specified and as directed. |
| 18 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams etc. complete all as specified and as directed. |
| 19 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc. complete all as specified and as directed. |
| 20 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc. complete all as specified and as directed. |
| 21 | M &L RCC M-25 (using 20mm graded stone aggregate) design mix for chajja, sun shed etc. complete all as specified and as directed. |
| 22 | Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edge etc.complete all as specified and as directed. |
| 23 | M&L for RCC M-25 design mix as in walls, retaining walls, basement walls, ballast walls and the like of any thickness above top of footing including attached pilasters and buttresses complete all as specified and directed. |
| 24 | M&L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in precast cement concrete, manhole covers including all use of forms, moulds or machine moulds and setting the blocks, slabs etc in cement mortar 1:6,complete all as specified and directed. |
| 25 | Use and waste of form work to walls, retaining walls, basement walls, ballast walls and the like including attached pilasters and buttresses and similar work vertical or to batter, flat, fair finished surface of concrete complete all as specified and directed. |
| 26 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc. |
| 27 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 28 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. |
| 29 | Removing Excavated soil exceeding 250 M but not exceeding 500M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 30 | M&L for loose filling with brick bats of size 80 to 150mm in soakage wells complete all as specified and as directed. |
| 31 | M&L Brickwork with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1:6). complete all as specified and as directed. |
| 32 | M&L Brickwork with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1:4). complete all as specified and as directed. |
| 33 | M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4). complete all as specified and as directed. |
| 34 | M&L for brick work with old size full brick th in Honey comb wall, brick subclass ‘B’ burnt clay bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4) complete all as specified and directed. |
| 35 | M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 36 | All as per item No. 35 here in before, but 6mm to 8mm dia. |
| 37 | All as per item No. 35 here in before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 38 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed |
| 39 | M&L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface. |
| 40 | M&L 75mm thick PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base of floors etc. complete all as specified and as directed. |
| 41 | M&L 25mm thick PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in sub base of floors etc. complete all as specified and as directed. |
| 42 | M&L for Mirror polished Kota Stone slab flooring/ treads of 20-25 mm thick over cement screed bed 15mm thick in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 43 | M&L for Kota Stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed bed 10mm thick in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 44 | M&L Joint free Non - skid coloured ceramic tiles 7 to 10 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry over screed bed of 10 mm thick in cement mortar 1:4 and pointed in white or coloured cement to match complete. |
| 45 | M&L Glazed coloured ceramic tiles in verticle surfaces 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match with backcoat of screed bed or bedding layer 10mm thick in cement mortar 1:3 and pointed in white or coloured cement to match complete all as specified.. |
| 46 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls by adding 17-19% of potable water by weight of material for thickness above 15mm it is recommended to be applied in multiple layers. ready mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the compressive strength @ 28 days 10-12 Mpa/Bulk density 1500-1600 Kg/m3. (Note : The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 Mtr height all as specified and directed) |
| 47 | M&L for preparation of new plastered surfaces of wall and two coats of oil bound distemper over a coat of primer complete all as specified & directed. |
| 48 | M & L for rendering 5 mm thick on fair faces of bricks/concrete surface in cement mortar (1:3) on RCC surfaces, celings, sides of beams, columns finishing the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 49 | M&L for Rendering 15mm thick in cement mortar 1:4, including finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 50 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer complete all as specified & directed. |
| 51 | M&L for extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete. |
| 52 | Material & Labour preparation of newly plastered surfaces of wall and applying wall care putty 2mm thick (averaging) in two coats on wall surfaces including cornics etc for proper levelling of plaster and applying a two coats of exterior emulsion paint over a priming coat (as per manufacturers instruction) including all preparation complete all as specified and directed |
| 53 | M & L for 75 mm thick PCC 1:3:6 type C-2 using 20mm using 40mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3. complete all as specified and directed as per Engr-in-Charge. |
| 54 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone for window cills in one pice including 15 mm thick screed bed in cement mortar (1:6) etc. complete all as specified and as directed. |
| 55 | S & F machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and as directed. |
| 56 | M&L for Water proofing treatment on \\"Non approachable / non accessible roof\\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer complete all as specified and directed(i) Applying approved bituminous based primer conforming to IS : 3384-1995 @ 0.3kg/Sqm to be applied on top surface of prepared surface till the surface is properly impregnated.(ii) Laying APP (Atactic polypropylene Polymer Modified preffabricated membrane) waterr proofing membrane of weight not less than 3 kg/sqm with minimum 100mm side overlap along the length from downward to upward completely sealed with torch application/hot blown lamps.(iii) Applying two cots of bituminous based aluminium paint @ 0.3 kg/Sqm complete all as specified and as directed. |
| 57 | S&F plain framed solid, chowkhats and frames, wrought rebated on solid rounded or chamfered put together with glue pinned supplied and fixed 2nd class hard wood complete all as specified and directed. |
| 58 | S&F for factory made prepainted 35mm thick flush shutters, solid core construction, with block board core and plywood face panesls, commercial type on bothe sides complete all as specified and as directed. |
| 59 | S&F Factory made single extruded WPC (wood polymer Composite) solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45 x 70 mm comprising of PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wwod powder/ rick husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms ) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded stat headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm 2 and resistance to spread of flame of Class A catogory with property of being termite/ borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast/lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). |
| 60 | S&F Factory made single extruded WPC (wood polymer Composite) solid plain flush door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/ cum and screw withdrwal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N mm2 modulus of elasticity 850 N / mm2 and resistance to spread of flame of Class A catogary with property of being termite/ borer proof, water/ moisture proof and fire retardanat and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-In-Charge (Note:- stainless steel butt hinges and necessary SS screws shall be paid separately. |
| 61 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 62 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 63 | M&L Anodised aluminium grills DG-104 powder Coating to Item No. 10087 above to (minimum thickness of powder coating 50 micron) , windows, ventilators including necessary C chanels, screws etc. complete all as specified and as directed. |
| 64 | S&F Aluminium anodised barrel tower bolt extruded section and fixed of size 150 mm complete all as specified and as directed. |
| 65 | S & F Stainless steel butt hinges 100 mm medium weight colled rolled complete all as specified and directed |
| 66 | M&L for aluminium 300 mm long sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or aluminium alloy and fixed complete all as specified and directed. |
| 67 | S & F 150mm long aluminium handles cast type, anodised complete all as specified and as directed |
| 68 | S&F Factory made precoated steel window and vents (Box Section) with glass shutter and fly proof shutter incl guard bars as per HQ CEBZ Drg No TD/158 of sh 1/2 & 2/2 with and including all precoated fittings .NOTE: (i) Payment under this item will be make combined for steel frames, steel shutters and Guard bard/Grill, However unit rate quoted shall deemed to include cost of beading, fittings such as handles, hinges,Telescopic stays, locking arrangements and fixing of glass and wiremesh etc.(ii) Supply only 4 mm thick sheet glass and stainless steel wire mesh be measured and paid separately. (iii) Weight of Grill/Guard Bars, handle, hinges and locking arrangements shall not be accounted for payment purpose seperately. |
| 69 | M&L Sheet glass 4.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 70 | M&L figured glass, pin headed 4.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 71 | S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 72 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick commercial plywood & aluminium angle frame and fixed to wooden plugs with chromium plated brass screws washers |
| 73 | Supply and fixing wash hand basin vitreous China table top type of size 460mmx460mm including cutting hole and pinning in ends of brackets or erecting stand with fixing 32mm dia waste coupling brass chromium plated suitable for wash basin and PVC waste pipe all as spd and directed . |
| 74 | S&F vitreous China squatting pan, Orissa pattern incl trap, size 580 x 440 mm white, with integral foot rests squat pattern closet also includes setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing (thickness as indicated) and making good floor complete all as specified incl cutting to the flush pipe and necessary repair to the floor complete all as specified and directed. |
| 75 | S&F PVC Flushing Cistern 10 litre capacity, Low Level Valve Less, Symphonic Action type, White, with Inlet, Ball Valve, Float and Handle including 32mm dia PVC Flush Pipe, a Pair of MS Brackets,CP flush bend including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 including taking down unserviceable Flushing Cistern and connected Items of any description, complete all as specified and as directed. |
| 76 | S & F Vitreous China urinal half stall white (minimum), with grating and union for discharge pipe, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistren with brackets brackets flush pipe, grating and union for discharge pipe in repairs complete all as specified and as directed. |
| 77 | S&F PVC (SWR) floor trap 75mm, including jointing with solvent cement complete all as specified and as directed. |
| 78 | S&F 450mm long PVC connection of approved quality with brass check nuts at both ends for 15mm bore pipe complete all as specified and directed. |
| 79 | S&F PVC (SWR) bends for 110mm dia PVC pipes with rubber ring joints complete all as specified and directed |
| 80 | S&F PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 81 | S&F PVC (SWR) pipes 110 mm single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed. |
| 82 | S&F PVC (SWR) pipes75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 83 | S&F PVC bends for 75 mm bore complete all as specified and directed |
| 84 | S&F PVC (SWR) 110 mm bore junction single, (Single T) equal or unequal complete all as specified and as directed. |
| 85 | S&F PVC (SWR) 75 mm bore junction single, (Single T) equal or unequal complete all as specified and as directed. |
| 86 | S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and as directed. |
| 87 | S&F cast iron (Spun pipes) 75mm soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and as directed. |
| 88 | M & L DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid in trenches and jointed as per IS complete all as specified and directed. |
| 89 | S&F Rotational moulded polythene water storage tanks, double layered (Cylindrical vertical with closed top) of capacity 1000 lit, with 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. minimum weight 20 mm - 210 gms and fixed to pipe 20mm hoisted and fixed in position as complete all as specified. |
| 90 | S&F gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of bore 20mm fixed as complete all as specified and directed. |
| 91 | S&F gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of bore 15 mm fixed as complete all as specified and directed. |
| 92 | S&F Angle stop cock fancy type, brass chromium plated with CP wall cap 15 mm bore after taking down of old brass stop valve complete all as specified. |
| 93 | S&F Bib tap cast copper alloy chromium plated, fancy type, with capstain head handle screwed down screwed for iron pipe and fixed to 15mm bore pipe after taking down of old brass bib tap complete all as specified. |
| 94 | S&F Steel water tubing medium grade 15mm bore galvanised with all fittings laid in trenches complete all as specified and directed. |
| 95 | S&F Steel water tubing medium grade 15mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 96 | S&F 20mm bore medium grade galvanized steel tubes with all fittings and fixed to wall and celing or laid in floors etc complete all as specified and directed. |
| 97 | M & L for cutting existing steel tubing of size 32 to 80mm for alterations or additions alongwith insertion of GI Tee of suitable size and connection material complete all as specified and directed. |
| 98 | S&F CP towel rail 600 mm long fixed with and including chromium plated brass screws and wooden / plastic cleats. |
| 99 | S&F glass shelf with CP railings 600 mm long fixed with and including chromium plated brass screws and wooden / plastic cleats complete all as specified and as directed. |
| 100 | S&F Brass CP Basin mixer for mixing hot & cold water screwed down for iron pipe and fixed bore of pipe 15mm complete all as specified |
| 101 | M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping,benching, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 102 | S & F Stainless Steel grating 125mm dia complete all as specified. |
| 103 | S & F for Plates Fe-410- W(Gde E-250) quality B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed. |
| 104 | Fe-410-W(Gde-E-250) quality-B Joists, channel, angle (45x45x6) or tee sections, fixed independently, without connecting, without connecting plates etc (cut to ordinary lengths complete all as specified and as directed. |
| 105 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS - 1161- 1979 grade St.-240 complete all as specified and as directed. |
| 106 | S&F Mild steel bolts exc 12 mm n exc 20 mm in dia purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and as directed. |
| 107 | S&F Mild steel bolts exc 12 mm n exc 20mm in dia purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. n 30cm long complete all as specified and as directed. |
| 108 | M & L preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. |
| 109 | S&F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall , fixed with self tapping screw as specified and directed |
| 110 | M&L Plain, galvanised 0.63mm thick, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all specified and directed. |
| 111 | S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed including necessary fittings like socket, bend, elbow, single/double tee etc in any length with rubber ring joints fixed with clamps of flat iron and including bolts and nuts and securing ends of stays to wall or roof complete all as specified and as directed. |
| 112 | Supply only WPC complete all as specified and directed. Please Enable Macros to View BoQ information |
| 113 | Supply only WPC complete all as specified and directed. Please Enable Macros to View BoQ information |