| 1 | Taking down old and unserviceable alumunium point wiring in batten/ conduit and make good the disturbed surface to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 2 | Taking down old and unserviceable submain wiring any size of two core including earth wire complete including batten/ conduit and make good the disturbed surface to match the existing surface complete all as directed by Engr-in-charge. |
| 3 | Taking down old and unserviceable, distribution board any type including/ sheet metal enclosures, after removing all connection and make good the disturbed surface all as directed by Engr-in-chanrge |
| 4 | M&L for Point wiring using FRLSLH PVC insulated unsheathed, multistranded copper conductor cable 1.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc fo concealed conduit wiring with modular flush box metal of GI sheet minimum 1.5 mm thick with earth terminal for safety, flush metal GI box of required modules as per site requirement and modular cover plate with support frame white in colour of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for one light/fan/bulb point controlled by one switch 6 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note:- (a) wiring shall be done by using colour coding (b) Earth wire shall be of green colour. (Make:-Finolex/Grandlay/Polycab/L&T/KEI/Havells) |
| 5 | Description all as per ser item No 4.00 above One 3 pin socket outlet, 5/6 Amp socket outlet on same board with other switches. |
| 6 | Description all as per ser item No 4.00 above but One 3 pin socket outlet, 5/6 Amp socket outlet on independent board. |
| 7 | Description all as per ser item No 4.00 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size. |
| 8 | Description all as per ser item No 4.00 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 9 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 10 | M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 11 | M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge. |
| 12 | M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 13 | M & L for point wiring to one 3 pin 15/16 Amps socket outlet independent switch board, using FRLS-H PVC insulated unsheathed, multistranded copper conductor cable 2.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc for concealed conduit wiring with modular flush box metal of GI sheet minimum 1.2 mm thick with earth terminal for safety, flush metal GI box of required modules as per site requirement and modular cover plate with support frame white in colour of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for power point controlled with cables, 2.5 sq. mm size, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. |
| 14 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge. |
| 15 | M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 16 | Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for flush type switch with cover plate, cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green) |
| 17 | Description all as per ser item No 16.00 above but One 3 pin 5 amps socket outlet point on same board complete all as specified and directed. |
| 18 | Description all as per ser item No 16.00 above but One 3 pin 5 amps socket outlet point on independent board complete all as specified and directed. |
| 19 | Description all as per ser item No 16.00 above but wiring with cable 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 20 | Description all as per ser item No 16.00 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 21 | Supply and fixing in repair Bell push,flush type 5 Amps complete all as specified and directed. |
| 22 | Supply and fixing buzzer dingdong AC 230 Volts, single pole, 50 Hz complete all as specified and directed. |
| 23 | Supply and fixing in repair Socket outlet 2 in 1, 3 pin, 5 amp flush type ISI marked for the same board complete all as specified and directed. |
| 24 | Supply and fixing in repairs switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 25 | Supply and fixing in repair Switch piano, flush type single pole, one way 5 Amps 3 pin, ISI marked for the same board complete all as specified and directed. (Make:- Havells or equivalent in Indoasian/Legrand/Anchor) |
| 26 | Supply and fixing in repair Socket outlet 3 pin, 15 Amp, flush type , ISI marked complete all as specified and directed. |
| 27 | Supply and fixing in repair Switch piano 15 Amp, flush type single pole, ISI marked 16 AX Amps One Way switch omplete all as specified and directed. |
| 28 | Supply and fixing in repair Ceiling rose, 3 phase/PVC/polycarbonate, isolated body type complete all as specified and directed. |
| 29 | Supply and fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed. |
| 30 | Supply & Fixing in repair only LED lights fitting 20 W LED 6000K (4Ft),(Warm/ Warm White) 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 31 | Supply and fixing in repair LED light fitting 2 feet, 10 watt 220 V AC (Warm/ White) decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 32 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.Notes:- (i) Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit. |
| 33 | M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 6 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 6 Sqmm single run for earthing. |
| 34 | M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 10 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 10 Sqmm single run for earthing. |
| 35 | Supply and fixing in repair modular 5 stepped type electronic fan regulator- 2M 100W laser marking as reqd at site complete all as per specified and directed. |
| 36 | Supply and fixing in repair round shape slim fit down light LED 15/18 Watt round recess (Warm/ Warm White) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completecomplete all as specified and directed. |
| 37 | Supply and fixing in repair square shape 36 watt 220 volts AC recessed mounting type low depth aesthetically designed LED 2x2 feet flat (Warm/ Warm White) panels, with high efficiency PMMA diffuser soft glare free light (Warm/ Warm White) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 38 | Supply and fixing in repair Sheet Metal enclosure double door for DBs when MCBs to be used TPN-4 Way with 200 Amp rated bus bar complete all as specified and directed. |
| 39 | Supply and fixing in repair Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 8 Way with 200 Amp rated bus bar complete all as specified and directed. |
| 40 | Description all as per ser item No 39.00 above but SPN - 12 Way complete all as specified and directed. |
| 41 | Supply and fixing in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volts complete all as specified and directed. |
| 42 | Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) TPN and current carrying capacity 63 Amp in the DB complete with connection testing and commissioning . |
| 43 | Supply and fixing in repair amp rating 240V, 10KA 'B'curve miniature circuit breaker (MCB) SPN and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning |
| 44 | Supply and fixing repair amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) SP and current carrying capacity 5-32 Amps in the MCB DB complete with connection testing and commissioning |
| 45 | Supply and fixing socket out let 5 Amps 3 pin flush type for the same board complete all as specified and directed. |
| 46 | Supply and fixing in repairs witch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 47 | Supply and fixing in repair switch socket combination out let 5/16 Amps 5 in 1 flush type complete all as specified and directed. |
| 48 | Supply and fixing in repair switch socket combination out let 5/16 Amps 2 in 1 in Box type complete all as specified and directed. |
| 49 | Supply only LED lights fitting 18 W LED 6000K (4Ft),(Warm/ Warm White) 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 50 | Supply and fixing in repairs switch socket combination 5 Amps 2 in 1 box type multipurposes for independent board complete all as specified and directed. |
| 51 | Supply and fixing in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 52 | Supply and fixing in repair Bell push,flush type 5 Amps complete all as specified and directed. |
| 53 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 54 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 55 | S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 56 | M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 57 | M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 58 | Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 59 | Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 60 | Supply and fixing Ventilating Fan 200 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 61 | S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge . |
| 62 | Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed. |
| 63 | M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. Length of wire of each roll is not less than 90 mtr. |
| 64 | Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge. |
| 65 | Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 66 | Supply & Fix white cover plate with frame 1 module complete all as specified and directed by Engineer in charge. |
| 67 | Supply & Fix white cover plate with frame 2 module complete all as specified and directed by Engineer in charge. |
| 68 | Supply & Fix white cover plate with frame 3 module complete all as specified and directed by Engineer in charge. |
| 69 | Supply & Fix white cover plate with frame 4 module complete all as specified and directed by Engineer in charge. |
| 70 | Supply & Fix white cover plate with frame 6 module complete all as specified and directed by Engineer in charge. |
| 71 | Supply & Fix white cover plate with frame 8 module complete all as specified and directed by Engineer in charge. |
| 72 | Supply & Fix Sheet 4\\" x 4\\" two cuttings suitable for two piano switches |
| 73 | Supply & Fix Sheet 4\\" x 7\\" three cuttings suitable for three piano switches |
| 74 | Supply & Fix Sheet 4\\" x 7\\" one cutting for 6 Amp socket and two cuttings for piano switches |
| 75 | Supply & Fix Sheet 8\\" x 10\\" incl cuttings for switches and sockets 6/16Amps as directed. |
| 76 | Supply & Fix Sheet 10\\" x 12\\" incl cuttings for switches and sockets 6/16Amps as directed. |
| 77 | Supply and fix LED 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 25,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. |
| 78 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |