Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil. |
| 2 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 3 | 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 4 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 5 | 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. DSR-16.91.2 (Interlocking over 50mm Sand)DSR-16.91.2 |
| 6 | 2. MS Railing |
| 7 | Earth work in trenches for foundation for pipes.cable etc in oridinary soil incl. lift up to 1.5 m and lead upto50 m & dressing of dides & ramming the bottom & disposal of surplus earth as per direction of E/I |
| 8 | C.C. work with cement approved coarse sand and 40 mm gauge approved stone ballast in proportion of 1:2:4 incl. cost of form work in foundation & floor |
| 9 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting , hoisting, fixing in position and B+61 applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Electric resistance or induction butt welded tube. |
| 10 | Providing and laying cement concrete 1:1.5:3 (1 cement :1.5 coarse sand :a graded stone ballast 20 mm nominal size ) supply of all materials labour T & P etc . Required for proper completion of work and curing complete , including cost of form work in foundation and floors .For fixing of poles and struts |
| 11 | Painting 2 coats over one primer coat over new steel work including cost of all material and T&P etc required for proper completion of work |
| 12 | Fixing of posts and wire mesh |
| 13 | 3. SEATING BENCH |
| 14 | Modern zigzag-shaped elevated planter integrated into a wooden deck. Constructed from durable composite or metal material. Filled with ornamental grasses and flowering plants for aesthetic appeal. Suitable for terraces, rooftops, or urban outdoor settings |
| 15 | Nature-integrated, peanut-shaped layout with organic flow Key Features: - Two main green zones with trees and grass - Elevated wooden walkway with steps, providing circulation and seating- Minimalist design using natural materials - Accommodates both leisure and passive recreation Capacity: Small groups (3–5 people visible in use) Use Case: Urban retreat or pocket park in dense environments |
| 16 | Design Type: Urban furniture / Biophilic seating Structure: Integrated planter bench with modern aesthetics Materials: Wooden seat slats, metal or composite base Greenery: Tall, leafy plants embedded in central planter section Usage: Comfortable single or dual-person seating with natural ambiance Application: Ideal for urban plazas, indoor atriums, or office lobbiesIf you'd like this formatted for a catalog or design portfolio, I can adapt it further! |
| 17 | Design Element: Sculptural Urban Bench Form: Continuous wave-like seating accommodating multiple usersMaterial: Likely wood or composite slats over a curved frameworkNatural Integration: Two trees planted directly within the bench footprint, providing organic shadingSurroundings: Paved plaza with neutral-toned tiles Function: Social seating encouraging both solitude and interaction Ideal Setting: Urban parks, university campuses, or cultural public spaces |
| 18 | Project Type: Urban Micro-GardenDesign Elements: - Elevated wooden deck foundation - Multiple built-in planters with a mix of ornamental and flowering plants - Round white floor cushions as informal seating - Natural, cozy atmosphere for relaxation or contemplation Materials: Timber decking, fabric cushions, metal or ceramic planters Function: Compact social or meditative retreat in dense urban areas Ideal Location: Rooftops, balconies, narrow alleys, or pocket parks |
| 19 | 4 Decorative ight work |
| 20 | Supply & fixing of steel tubular pole 9 Metre long designated 410 SP 32 in 1:3:6 cement concrete foundation including excavation backfilling etc. complete in all respect. |
| 21 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect. CAT-AAA |
| 22 | Supply & Fixing Pipe Bracket with Clamp suitable for Fixing of 75/90 Watt LED Street Light Complete as per Direction of Engineer in Charge (MR) |
| 23 | Supply and laying of 16 sq. mm 4 core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade over head.as directed by the Engineer-Incharge, complete in all respect .The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 24 | Supply and fixing 40 A TPN capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch, metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect as per direction of the Engineer in charge. |
| 25 | Supply and laying of 16 sq. mm.plain or pin type aluminium in plated cable socket with end to end cable pieces, insulating with tape and making connection with pole & panel board as per direction of the Engineer-in-charge. |
| 26 | Supply & erection of stay set at least 3.5 Metres away from the pole complete with galvanised 19 mm dia x1.80 Metre long stay rod, 30 cm x 30 cm x 6.3 mm anchor plate, thimble stay clamps, stay insulator, 19 mm x 600 double screw tightening, 7/4.00 mm G.I. stay wire etc. in 1:3:6 cement concrete complete in all respect. |
| 27 | Aluminium White Outdoor Led Bollard Light, Mounting Type: Surface, B22 |
| 28 | 15w high beam narrow highlighter |
| 29 | 3w Aluminium LED In Ground Uplighter, For Outdoor, Voltage: 210V |
| 30 | 24 W Facade Light Designs, For Outdoor |
| 31 | 1. LED Meteor Shower Lights in TreeType: Waterproof, cascading/meteor shower LED lightsSize: Approx. 8 tubes x 30-50 cm eachQuantity (based on image): Approx. 10–12 sets2. Additional String Lights (Warm White)For outlining branches and tree structureLength required: Approx. 30–40 meters3. AccessoriesExtension wires, power adapters, fasteners4. Installation Labor ChargesDepends on tree height, complexity, and local labor rates |
| 32 | 5. FACADE LIGHT FOR GIRJA GHAR |
| 33 | Supply Installation Testing & Commissioning of Projector light for highlighting the architectural elements of Temples (Pillars/Walls/Temple domes/etc.),having the Minimum wattage 9W-14 W with 30/45/60° beam angle with high pressure die cast aluminum housing for efficient thermal management, sturdiness & excellent corrosion resistance ,with IP-66,IK-07,High efficiency long life COB LED mounted on MCPCB of fixture. Lumen efficacy of LED >140 lm/W, Minimum 1400 Lumen output at 3000K CCT,PF->0.95,THD-<10,CRI->80,Average Burning Hours Life-50000Hrsat L70B50, Electronic driver, Powered by an Built-In potted, electronic driver (SMPS based constant current supply) with lower THD, Output Open/ Short circuit protection, Surge voltage protection up to 4kV & other safety test as per IS:15885 Part 2/Sec 13. With 5 Years O&M Make:Havells/Ligman/Bega |
| 34 | Supply Installation Testing & Commissioning of Projector light for highlighting the architectural elements of Temples (Pillars/Walls/Temple domes/etc.),having the Minimum wattage 9W-14 W with 30/45/60° beam angle with high pressure die cast aluminum housing for efficient thermal management, sturdiness & excellent corrosion resistance ,with IP-66,IK-07,High efficiency long life COB LED mounted on MCPCB of fixture. Lumen efficacy of LED >140 lm/W, Minimum 1400 Lumen output at 3000K CCT,PF->0.95,THD-<10,CRI->80,Average Burning Hours Life-50000Hrsat L70B50, Electronic driver, Powered by an Built-In potted, electronic driver (SMPS based constant current supply) with lower THD, Output Open/ Short circuit protection, Surge voltage protection up to 4kV & other safety test as per IS:15885 Part 2/Sec 13. With 5 Years O&M Make:Havells/Ligman/Bega |
| 35 | Supply, Installation, Testing and Commissioning of exterior BIS registered LED flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness, of Total System wattage not exceeding 120W -140W with system lumen output > 11000 lm with all LEDs on , minimum system lumen efficacy > 90lm/w. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 364 mm±5% including surface mount base width 188 mm±5% , length 390 mm ±5% with constant locking hinges for simple position control from various angles without special tools.Fixture shall be suitable to operate at an ambient temperature range of -30°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9.The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79,Required CCT-3000k, BIS Report and LEDs Test Reports.Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.With 5 Years O&M Make:Havells/Ligman/Bega |
| 36 | SITC of exterior flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness, of Total System wattage not exceeding 70W-80W with system lumen output > 6500 lm with all LEDs on , minimum system lumen efficacy > 90lm/w. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 364 mm±5% including surface mount base width 188 mm±5% , length 390 mm ±5% with constant locking hinges for simple position control from various angles without special tools.Fixture shall be suitable to operate at an ambient temperature range of -20°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac,Required CCT-3000k, 50Hz with power factor > 0.9.The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports.Luminaire shall be conforming to BIS IS 15885 Part-2/ Sec 13,IEC60598-1. and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.With 5 Years O&M Make:Havells/Ligman/Bega |
| 37 | SITC of exterior flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness, of Total System wattage not exceeding 50W-60W with system lumen output > 4500 lm with all LEDs on , minimum system lumen efficacy > 90lm/w. Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 364 mm±5% including surface mount base width 188 mm±5% , length 390 mm ±5% with constant locking hinges for simple position control from various angles without special tools.Fixture shall be suitable to operate at an ambient temperature range of -20°C to 50°C and complete luminaire shall be IP66 and IK07 rated. LED Life time shall be at least L70B50 @ 70000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac,Required CCT-3000k, 50Hz with power factor > 0.9.The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports.Luminaire shall be conforming to BIS IS 15885 Part-2/ Sec 13,IEC60598-1. and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.With 5Years O&M Make:Havells/Ligman/Bega |
| 38 | SITC of exterior rated Architectural Linear LED Wall Washer luminaire; suitable for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, Total System wattage 60W- 70W with system lumen output should be Min.5400 lm in CCT-3000k with all LEDs on.The Fixture beam angle should be 25/40/17x35/30x65 degree, Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 80 mm ± 5% including surface mount base width 59 mm ± 5% , Min length 1000 mm ± 5% with constant locking hinges for simple position control from various angles without special tools. DMX enabler circuit should be inside the Luminaire only. The rated voltage of the Luminaire should be 230Vac, Luminaire shall be offered with a BIS Approved Potted Driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient, Led Driver should have Operating input voltage range: 90-305VAC, PF > 0.90 and must have safety operation range form 90V - 176Vac. Life time of LED driver should be > 80,000 hours and MTBF of LED driver should be ≥ 2,00,000 hrs, Led driver must have SELV output and Case temperature i.e. Tc > 90°C. Fixture shall be suitable to operate at an ambient temperature range of -20°C to +50°C and complete luminaire shall be IP66 and IK07 rated.CCT-3000k, LED Life time shall be at least L70B50 @ 50000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only.The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports.Luminaire shall be conforming to BIS i.e. IS 15885 (Part 2/Sec -13) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.With 5 Years O&M Make:Havells/Ligman/Bega |
| 39 | SITC of exterior rated Architectural Linear LED Wall Washer luminaire; suitable for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass of 4mm thickness and die casted end caps, Total System wattage 36W- 40W with system lumen output should be Min.2800 lm in CCT-3000k with all LEDs on.The Fixture beam angle should be 25/40/17x35/30x65 degree, Luminaire should be complete with dedicated Lens made up of UL/VDE approved PC for each LED, offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture should have Height 80 mm ± 5% including surface mount base width 59 mm ± 5% , Min length 1000 mm ± 5% with constant locking hinges for simple position control from various angles without special tools. DMX enabler circuit should be inside the Luminaire only. The rated voltage of the Luminaire should be 230Vac, Luminaire shall be offered with a BIS Approved Potted Driver of IP 66/67 rating made of extruded aluminium to make it more thermal efficient, Led Driver should have Operating input voltage range: 90-305VAC, PF > 0.90 and must have safety operation range form 90V - 176Vac. Life time of LED driver should be > 80,000 hours and MTBF of LED driver should be ≥ 2,00,000 hrs, Led driver must have SELV output and Case temperature i.e. Tc > 90°C. Fixture shall be suitable to operate at an ambient temperature range of -20°C to +50°C and complete luminaire shall be IP66 and IK07 rated.CCT-3000k, LED Life time shall be at least L70B50 @ 50000 burning hours at 50°C. LED should be with ceramic package of make Nichea, Osram, Cree, Lumiled only.The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports.Luminaire shall be conforming to BIS i.e. IS 15885 (Part 2/Sec -13) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.With 5 Years O&M Make:Havells/Ligman/Bega |
| 40 | Planning, Designing, Programming of all the light fixtures with integration into controller and making multiple programming in total of 5 different occasion. Synchronizing all fixtures into one. |
| 41 | Supply installation commissioning of following sizes of power and data cable as mentioned: |
| 42 | 3 x 2.5 sqmm Cu unarmored multistrand |
| 43 | 4 x 16 sqmm Al armoured |
| 44 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properlyconnected with the earth. |
| 45 | 16 sqmm |
| 46 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and makingconnection etc. |
| 47 | 4 sqmm |
| 48 | 16 sqmm |
| 49 | Supply and fixing of horizontal air termination (roof conductor) of 25mm x 3mm G.I. strip, G.I. clamps on surface complete inall respects |
| 50 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC)capable of reducing the soil resistivity with good mixture of retaining capacity |
| 51 | IP-67/68 Junction Box for Fixture connection |
| 52 | Supply, installation, testing and commissioning of cages for protection of light fixtures of suitable size made of stainless steel 304 grade having wire mesh with spacing of 1.5 - 2 inches and sturdy to avoid ohysical damage with base frame being made of 4mm thick strip |
| 53 | Supply, installation, testing and commissioning of PVC Pipe of size 20 mm as per requirement for cable layingand its protection. |
| 54 | Supply, installation, testing and commissioning of PVC Pipe of size 40 mm mm as per requirement for cable layingand itsprotection. |
| 55 | Supply, installation, testing and commissioning of Electrical panel with Servo Bypass swith on incomer having 63 A MCCB with Surge Protection Device for all phases with minimum 6 No outgoing of 6 A DP MCCB A compartment having twoswitches for safekeeping the controller and other necessary equipments |
| 56 | Supply, installation, testing and commissioning of Oil Cooled Servo Stabilizer of 25 KW Three Phase with Enclosure and connection to the main panel. with rating of 180-250 V stabilizong and maintaining a fixed voltage output of 220Volt for theentire system. |
| 57 | 6. DUSTBIN (As per quotation ) |
| 58 | MOFNA 100 L Silver Stainless Steel Open Top Dustbin 16x28 Inch, MSS712 |
| 59 | 7. COST OF CREATION OF SPRINKLE SET OR IRRIGATION WORK (FOR NURSERIES AND GRASS PATCHES.(As per quotation attached) |
| 60 | HDPE PIPE IS: 4984 - PE 100 PN 6 (Vinplast/rajkee/Equiv) |
| 61 | 63 mm 6kg/cm2 (Mtr) |
| 62 | FITTINGS & ACCESSORIES (Tee, bend, elbow,Endcap etc) |
| 63 | MINI RAINGUN SPRINKLER SYSTEM |
| 64 | 1-1/4\\" size bsp inlet sprinkler with socket for connection (automat/harit/equiv) |
| 65 | 1-1/4\\" size hydrant with ASTM nipple,thrust block & 6\\" valve box (harit/equiv) |
| 66 | 1-1/2 \\" ARV (Harit/equiv) |
| 67 | 63mm x 1-1/4\\" size pp clamp saddles PN 10 (imported) |
| 68 | 1-1/2\\" PRV (Harit/equiv) |
| 69 | 1-1/4\\" size steel key with connecting assembly |
| 70 | DRIP IRRIGATION FOR HERBS & SHRUBS |
| 71 | LLDPE PIPE 16MM WITH INLINE DRIPPER |
| 72 | VENTURY ASSEMBLY |
| 73 | FITTINGS & ACCESSORIES |
| 74 | INSTALLATION |
| 75 | Installation , Testing & Commissioning of Irrigation system |
| 76 | Earthwork excavation & Refilling 450 mm x 450 mm |
| 77 | 8. SELFIE POINT |
| 78 | Earth work in excavation by mechanical means {Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. DSR-2.6.1 |
| 79 | 1 :4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). DSR-4.1.8 |
| 80 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: DSR-6.1.2Cement mortar 1 :6 (1 cement : 6 coarse sand) |
| 81 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1 : 6 ( 1 cement : 6 coarse sand):DSR-6.3.1 |
| 82 | Kata stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): DSR-11.26.1 25 mm thick |
| 83 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1 :3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1 :2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : DSR-8.14.1.5 |
| 84 | Lawn as per detailed attached including all complete as per engineer in charge. (AR) |
| 85 | Mural work as per architehtural designing including all complete as per direction of engineer in charge. (As per quotation) |
| 86 | 12 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)(DSR-13.5.2) |
| 87 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(Outer surface)(DSR-13.47.1) |
| 88 | LED Strip Light 12W IP-65 (3000K warm white) |
| 89 | Aluminium Profile Channel for LED Strip |
| 90 | LED Driver 150W waterproof |
| 91 | Focus Light 12W (wall wash effect) |
| 92 | Downlight 9W concealed |
| 93 | Electrical wiring (Finolex 1.5 sq.mm + casing caping) |
| 94 | Control panel with MCB & connectors |
| 95 | Labour for installation, wiring & testing |
| 96 | 9 SIGNAGE |
| 97 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation (D.S.R.-2.6.1) |
| 98 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone ballast 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. D.S.R.-4.1.8 |
| 99 | Providing and laying in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone ballast 20 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. D.S.R.-4.1.3 |
| 100 | Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.(D.S.R.-10.1) |
| 101 | Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works)(D.S.R.-13.62.1) |
| 102 | Add for Letter writing |
| 103 | 10. PARKING |
| 104 | Providing & laying of 80 mm th. Inter locking C.C. Pavers 12 cm th. C.C. (1:4:8) with cement & coarse sand with 40 mm gauge stone ballast including 4 cm thick fine sand cushion and 3 cm th. local sand filling over entire surface of interlocking and gaps and corner filled with (1:3) cement mortar. incuding cost of all materials labour T & P.( D.S.R.-4.1.8) Cost of C.C. (1:4:8), 1x1x0.10 |
| 105 | Providing & Laying of interlocking tile of thickness 80 mm including levelling and dressing of surface to required level and slope, filling joints with local sand including the cost of all labour T&P etc complete but excluding the cost of all material . |
| 106 | 11. CANOPY (As per QUOTATION) |
| 107 | This is a unique, tree-like permanent canopy structure. It's made of a light-colored material with many irregular, organically shaped openings that allow natural light and greenery to filter through while providing shade. It's located in a park or urban green space made of frp |
| 108 | 12. SCUPLTURE |
| 109 | Pair of cupped hands holding a live tree FRP (Fibre Reinforced Plastic), GRC (Glass Reinforced Concrete), or cast resin with weatherproof coating.Fini+A127:G138sh: Matte or semi-gloss white finish, UV and weather resistant.Steel reinforcement inside for durability and strength Length: 2.5 to 3.0 meters Width: 2.0 to 2.5 meters Height: 1.2 to 1.5 meters (excluding the tree) Tree Height: 2.5 to 3.5 meters (varies by selection) |
| 110 | Artistic installation of seated human sculptures under trimmed topiary-style trees. Each tree appears to grow out of the sculpture, merging nature and art.Installed on a slightly raised mound for visual impact. Material: FiberglassSculpture Height: 4 ft set of 7 sculptures |
| 111 | Wings: FRP (Fiberglass Reinforced Plastic) / HDPE / Polymer Resin / Aluminum Base: Polished Stainless Steel or Granite Stone Finish: High-gloss white with UV-protective coatingSize (approximate): Height: 6–7 feetWidth: 8–9 feet (wing to wing)Depth: 2–3 feet |
| 112 | Structure: Mild Steel frame with fiber (FRP) & waterproof fabricFace & Flowers: Molded FRP or PVC with detailed hand paintingLighting: RGB LED lights (IP65), programmable with DMX controllerBase Platform: Reinforced wooden/FRP platform with floral elements Finish: Weatherproof & UV-resistant coating, high-gloss paintHeight: Approx. 12–14 feetDiameter (Canopy/Top): 10–12 feetPower Supply: 230V AC with power control box and timerFoundation: Base plate with MS anchor bolts or hidden foundation |
| 113 | 13. KIOSK (SHOPS) (As per QUOTATION) |
| 114 | which is a large, open-sided structure designed to provide shade and a focal point in an outdoor setting like a park. It features a distinctive, multi-tiered, wave-like roof structure, likely made of a woven or patterned material in an earthy tone, supported by several dark, arched pillars. Underneath, there appear to be seating areas or art installations, contributing to a modern and inviting outdoor space |
| 115 | 14. GAZEBOS (As per QUOTATION) |
| 116 | This is a large, architectural canopy structure with a striking design. It features a flowing white fabric roof supported by a network of curved, golden-colored framework, possibly bamboo or a similar material designed to mimic it. It appears to cover an outdoor public space, like an entrance to a building or a plaza, providing both shade and a distinctive aesthetic appeal |
| 117 | 15. LANDSCAPE |
| 118 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil |
| 119 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. |
| 120 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment) |
| 121 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm |
| 122 | Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). |
| 123 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 124 | Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded). |
| 125 | Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge |
| 126 | Supplying & Stacking of Selection No.1 doob grass turf at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of the officer in charge. |
| 127 | Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/edge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge. |
| 128 | Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge |
| 129 | For Trees/Plants |
| 130 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Trees Plant |
| 131 | For Trees/Plants |
| 132 | Hedges Plant/ Ground cover |
| 133 | Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big polybag of size 25 cm as per direction of the officer -in-charge. |
| 134 | Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big polybag of size 25 cm as per direction of the officer -in-charge. |
| 135 | Supply and stacking of Azadirachta indica (Neem) plant of height 120-130 cm. in big polybag of size 25 cm as per direction of the officer -in-charge. |
| 136 | Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 137 | Providing and stacking of Tabernaemontana coronaria (Chandni single) of height 90-105 cm.,bushy in big size HDPE bag as per direction of the officer-in-charge. |
| 138 | 16. TOILET RENOVATION |
| 139 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 140 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand). |
| 141 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 142 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (FLOORING) |
| 143 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 144 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (Both side laminated) |
| 145 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. Single leaf. |
| 146 | (b) Double leaf |
| 147 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, |
| 148 | including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerancein dimension i.e. in depth & width of profile shall be acceptable. |
| 149 | Three track three panels sliding window with two glazed & one wire mesh panels with alluminium channel for roller track, wool pile, nylon rollers with s.s. 304 body. |
| 150 | Using R2 series with foame (70mm & above)x(40 mm & above) & both glazed and fly screen sash (25 mm & above)x(50mm & above with zinc alloy (zamak) powder coated touch lock with hook (Height up to 1.20 meter) |
| 151 | Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and irection of Engineer-in-charge. |
| 152 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coat |
| 153 | Ground Floor |
| 154 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)(Outer surface) |
| 155 | Ground Floor |
| 156 | Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : Two coat |
| 157 | Ground Floor |
| 158 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 159 | Ground Floor |
| 160 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 161 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 162 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete |
| 163 | (a) 300 mm x 10mm |
| 164 | (b) 250 mm x 10mm |
| 165 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 166 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 167 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4 mm thick |
| 168 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail