| 1 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in straight or open area including dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of diversion for traffic, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. |
| 2 | Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work. |
| 3 | First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth |
| 4 | 10mm thick Cement Plaster 1:3 |
| 5 | Providing & fixing 225 mm alpha valve including carriage, rehandling, loading, unloading, testing, etc. complete in all respect as per PWD specifications or instructions of the engineer in charge. |
| 6 | Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications 225 mm O/d UPVC pipe of 2.5 Kgf. / sqcm |
| 7 | Providing & fixing 225 mm Dia. Equal Tee (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 8 | Providing & fixing 225 mm Dia. Short OR long Bend (90 Degree)(6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 9 | Providing & fixing 225 mm PVC BENDS OF 45 DEGREE (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 10 | Providing & fixing 225 mm Dia. Socket (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 11 | Providing & fixing 225mm Tail end point 6kg with M.S./C.I. flange(6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 12 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer incharge)(A) Class PN-1 as per ISI (g)250 mm i/d Sluice Valves flanged |
| 13 | Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing all carriages complete C.I Single air valve Screwed(Size 50mm) |
| 14 | Providing & fixing 200x50 mm Dia. MS Service saddle (6 kg/cm2 pressure) conforming to IS codes with latest amendments if any at site of work including loading, unloading and rehandling if any complete in all respects as per design and P.W.D. specifications and instructions of engineer in charge. |
| 15 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6 m. x 0.6 m. |
| 16 | Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.9 m. x 0.9 m. |
| 17 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring. |
| 18 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering). Complete in all respect as per Designs, Specifications and Instructions of Engineer-in-charge. |
| 19 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. |
| 20 | Providing, laying, fixing, testing and commissioning of C Class heavy duty MS Pipe conforming to IndianStandard IS:1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nutsbolts, gasketsetc. fixing the pipe on the wall /ceiling with suitable clamp sandpainting with two or more coats of synthetice paint of required shade complete in all respects. (G)50mm internal diameter |
| 21 | Any Other Item (CSR + SP) Please Enable Macros to View BoQ information |