| 1 | Supply &Laying of following size of PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade on surface/ in panel etc as reqd |
| 2 | 4x25Sqmm cable |
| 3 | Supply & Laying of following size of PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade etc as reqd in the existing RCC/ HUME/ METAL pipe/ccable trench as required. |
| 4 | 4x25Sqmm cable |
| 5 | Supply & Laying of following size of PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade in the ground i/c excavating the earth upto a depth of 2.5 feet without bricks and sand cushtion etc as reqd |
| 6 | 4x25Sqmm cable |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 8 | 4 X 25 sq. mm (22mm) |
| 9 | Supplying and laying of following size pipe ISI marked along with all accessories like bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 10 | 40mm dia HDPE PE100,PN6 |
| 11 | 40mm dia GI B class |
| 12 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 13 | Supply and fixing of 63 A onload change over switch with Sheet steel Encloser with all accessories on the surface of wall etc as reqd |
| 14 | Supply & Fixing of 63A TPN SDFU switches on surface of wall in sheet Steel Enclosure with HRC fuses etc complete as required. |
| 15 | S/F of the 63A porcelain fuse cutout in the board on pole/meter box with all accessories etc as reqd |
| 16 | Overhead Servie connection arrnangement with 4 x 16 sq.mm size PVC insulated Al. conductor wire in the following manner |
| 17 | With 2 runs of stay wire and insulators |
| 18 | In loose looping/existing pipe |
| 19 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 20 | 4 way (4 + 12), Double door |
| 21 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker/isolators suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 22 | Single pole(6 to 32A MCB) |
| 23 | Triple pole MCB |
| 24 | 40 A FP Isolator |
| 25 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 26 | Group A |
| 27 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 28 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 29 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 30 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 31 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 32 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 33 | 1 x 1.5 sq. mm |
| 34 | 2 x 1.5 sq. mm |
| 35 | 3 x 2.5 sq. mm |
| 36 | 3 x 4 sq. mm |
| 37 | 2 x 6 sq. mm |
| 38 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 39 | 20 mm |
| 40 | 25 mm |
| 41 | 32 mm |
| 42 | 40 mm |
| 43 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. |
| 44 | 75 mm X 75 mm X 60 mm deep |
| 45 | 100 mm X 100 mm X 60 mm deep |
| 46 | 150 mm X 75 mm X 60 mm deep |
| 47 | 180 mm X 100 mm X 60 mm deep |
| 48 | 200 mm X 300 mm X 60 mm deep |
| 49 | 250 mm X 300 mm X 60 mm deep |
| 50 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 51 | 5/6 amps switch |
| 52 | 15/16 amp switch |
| 53 | 3 pin 5/6 amp socket outlet |
| 54 | 6 pin 15/16 amp socket outlet |
| 55 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 56 | Supplying and fixing 4P sheet steel enclosure on surface/ recess complete with connections, testing and commissioning etc. as required..(Standard or SS Make) |
| 57 | Supplying and fixing of 20W LED Batten on surface of wall / ANG partition i/c connections with 1.5 sqmm copper conductor cable etc. Complete as reqd. (Make: Crompton / Philips / similar superior) |
| 58 | Supplying and fixing of 20A AC metalclad box with suitable MCB etc as reqd |
| 59 | Installation, Testing and commissioning of new 1.5TR split AC unit along with copper piping, insulation, including mounting of indoor unit with suitable arrangements and outdoor units on existing frame work, etc. as required |
| 60 | Installation, Testing and commissioning of dismantled 1.5TR split AC unit along with copper piping, insulation, PVC drain pipe and wiring up to the standard length etc.,including mounting of indoor unit with suitable arrangements and outdoor units on existing frame work, pressure testing,vacumissation, gas charging the refrigerant system etc. as required |
| 61 | Providing and fixing suitable size copper pipes of additional length for hot gas & liquid line along with tubular foam insulation for the above 1.5TR S/T AC unit etc.as reqd. |
| 62 | S/L of 4 core x 2.5 sq.mm chord wire for 1.5TR S/T AC units in the existing pvc pipe etc complete as required. |
| 63 | S/F of R32 Gas Topping up for star rated 1.5TR Splt AC units upto rquired level |
| 64 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 65 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 66 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 67 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 68 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 69 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc.as required. |
| 70 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area / zone covered, complete with all onnections, interconnections as required. a) 4 Zone |
| 71 | Supplying, installation, testing & commissioning of smokedetector with builtin LED and mounting base complete with all connections etc. as required. |
| 72 | SITC of Electonic type hooter on the existing system etc as reqd(make:Ravel/Agni) |
| 73 | SITC of Manual call Point (MCP) on the existing system etc as reqd(make:Ravel/Agni) |
| 74 | SITC of 12volts, 7AH Battery connected for fire alarm panel (Exide make) |
| 75 | S/L of 2 core x 1.5 sq.mm fire alarm armoured cables on surface of wall with all accessories etc complete as required. Please Enable Macros to View BoQ information |