| 1 | CIVIL WORKS |
| 2 | Clearing grass and removal of rubbish upto a distance of 50 m outside the periphery of the area |
| 3 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in a) All kinds of soil |
| 4 | Earthwork in excavation in trenches for all leads & lifts in all type of strata comprising of any type of materials either in full or part as the case may be adopting any method/methods as may be convenient as permitted excluding blasting in all conditions such as dry, moist, foul, saturated, submerged, etc,. including dressing of sides, planking & strutting, timbering ,ramming of bottom ,pumping and bailing out water ,barricading danger lighting guarding, getting out excavated soil & stacking as directed by Engineer for all leads & lifts etc. complete |
| 5 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer . |
| 6 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 7 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in cm. 1 : 5 (1 cement : 5 coarse sand) in foundation upto plinth level |
| 8 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in cm. 1 : 5 (1 cement : 5 coarse sand) in foundation upto plinth level for laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 9 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:All works upto plinth level |
| 10 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in b) In retaining walls , return walls(any thk) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level. |
| 11 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) All works upto plinth level |
| 12 | Providing and laying upto floor five level cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size) including smooth finishing to exposed surfaces, with cement mortar 1:3 (1 cement: 3 fine sand) including centering and shuttering etc.Moulding as in cornices, window sills etc. exceeding 15 cm in girth. |
| 13 | Providing and laying in position ready mixed concrete (RMC) manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continious agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineer-in-charge. All works upto floor V level. M-25 grade of concrete |
| 14 | Centering & shuttering including Strutting, Propping & removal of forms for :Foundations, Footings, Bases for columns |
| 15 | Centering & shuttering including Strutting, Propping & removal of forms for :Vertical surfaces such as retaing walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like |
| 16 | Centering & shuttering including Strutting, Propping & removal of forms for :Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan) |
| 17 | Centering & shuttering including Strutting, Propping & removal of forms for :Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth |
| 18 | Centering & shuttering including Strutting, Propping & removal of forms for :Suspended floors, roofs landings, shelves & their supports |
| 19 | Centering & shuttering including Strutting, Propping & removal of forms for sloping or battering surface (slabs, beams, louvers, etc) including folded plates. Cornices & Mouldings |
| 20 | Extra to be added for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m, for every additional height of 1m or part thereof. (Plan area to be measured) Suspended floors, roofs, landings, beams and balconies (plan area to be measured) |
| 21 | Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) ) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 22 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 23 | Providing water proofing treatment over the new R.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab and laying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 ( 1 cement : 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square. The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost of initial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m. |
| 24 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer : Flamed finish granite stone slab. |
| 25 | Rounding of edges of marble slab to semi circular slope |
| 26 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, area of slab over 0.50 sqm. Jet black |
| 27 | Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. Size 600 x 500 x 75 mm with steel reinforcement not less than 2.25 kg per unit |
| 28 | Providing and laying jet black mirror polish granite flooring and dado over 20mm thick base of cement mortar 1:4 laid over and jointed with cement slurry including rubbling complete Granitic slab (jet blck with mirror polish) 20 mm thick add q0% wastage 1.00 |
| 29 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm. 60 mm thick in all colours except grey (M35 grade) |
| 30 | Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) a) 20 mm thick. |
| 31 | Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in charge. |
| 32 | Add for providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth upto610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 33 | Providing and fixing Prince or equivalent make PVC SWR half round eaves gutter with bolts, nuts and flat iron brackets 40 x 3 mm size complete.140 mm nominal size |
| 34 | Extra for providing flat iron bracket 50 x 3 mm size instead of 40 x 3 mm size with necessary bolts nuts, washers etc. for fixing A.C. gutters to purlins. |
| 35 | Extra for providing and fixing prince or equivalent make PVC SWR short stop ends for socketed half round eaves gutters. 140 mm nominal size |
| 36 | Brick work using common burnt building bricks in cement mortar 1:3 (1 cement : 3 coarse sand) with bricks of class designation 40 kg / cm2 (wire cut bricks) In superstructure upto floor five level. |
| 37 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 38 | Removing white or colour wash by scrapping, sand papering and preparing surface smooth including necessary repairs to scratches etc. complete. |
| 39 | Forming & Finishing the 20 mm groove in plastered surface & repair the edges as per specifications and directions of the Engineer In Charge. |
| 40 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield,APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 41 | Applying one coat of cement primer of approved brand and manufacture on wall surface. |
| 42 | Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture in all shade or new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture to give an even shade |
| 43 | Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 44 | Dismantling steelwork in built up sections in angles, tees, flats and channels including all gusset plates bolts, nuts, cutting dismembering and staking within 50 mts. lead |
| 45 | Dismantling doors, windows and clearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt. Lead Of area 3 sq.m. and below |
| 46 | Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead |
| 47 | Taking out existing CC interlocking paver blocks from footpath/ central verge, includingremoval of rubbish etc., disposal of unserviceable material to the dumping ground,for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charg |
| 48 | Providing and fixing statues (Lion statue 3D view) made up of POP of size 3.45ft x 4ft including all fitting fixtures , Finish should be similar to the photo features references,concepts of historic era's including all tools, plants, labour and materials, leads, lifts etc complete. as directed by Engineer-In-Charge. |
| 49 | Supplying & Planting shrubs, creepers, ground covers, as listed below as per the nursery size (0.3 - 0.45 m tall) including providing, spreading preparing soil mixture , adding fertilizers as per planting schedule,garden earth, manure and cocopeat etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Betel Nut Trees |
| 50 | Supplying & Planting shrubs, creepers, ground covers, as listed below as per the nursery size (0.3 - 0.45 m tall) including providing, spreading preparing soil mixture , adding fertilizers as per planting schedule,garden earth, manure and cocopeat etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation. Lawn Selection one |
| 51 | Supplying and stacking of good earth at site including royalty and carriage upto 1 km. (earth measured in stacks will be reduced by 20% for payment). |
| 52 | Spreading of sludge, dung manure or/and good earth in required thickness (cost of sludge, dung manure or/and good earth to be paid separately). |
| 53 | Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm. as per MORTH Specification 307 |
| 54 | Maintenance of lawns or Turfing of slopes(rough grassing) for a period of one year including watering etc. as per MORTH Specification 307 |
| 55 | Providing, Installating and commissioning weather proof, shock proof Arihant or equivalent make Double Arc Swing using Galvanized Steel, Pure Polyester, Nylon, Natural Rubber & finished with metal colours/roto colours/FRP colours with following details Product Size: 3.2m X 1.5m,Play Area: 4.2m X 2.5m, including Concrete foundation, holding down bolts, grouting with PCC of ratio (1:2:4) etc complete with One year Warranty as directed by Engineer-in-charge. |
| 56 | Providing, Installating and commissioning weather proof, shock proof Arihant or equivalent make Double Arc Swing using Galvanized Steel, Pure Polyester, Nylon, Natural Rubber & finished with metal colours/roto colours/FRP colours with following details Product Size: 3.2m X 1.5m,Play Area: 4.2m X 2.5m, including Concrete foundation, holding down bolts, grouting with PCC of ratio (1:2:4) etc complete with One year Warranty as directed by Engineer-in-charge. |
| 57 | ELECTRICAL WORKS |
| 58 | Supply of 4 core armoured PVC insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part II) with latest amendments of following size. 4 Core 25 sq.mm |
| 59 | Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 4 core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.4 x 25 Sq. mm. |
| 60 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.4 Core 10 sq.mm |
| 61 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.(4) 4 x 10 Sq. mm. |
| 62 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed lenghtwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. (b) In rocky strata |
| 63 | Supplying and laying 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode as required |
| 64 | Supply of 3 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.3 Core 2.5 sq.mm |
| 65 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs. d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement.(a) In rocky strata |
| 66 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 67 | SITC of outdoor stand mounted feeder pillar made up of 16 SWG CRCA sheet with 32A TPN MCB incomer, single dial timer, 25A cotactor for automatic switching of luminaries , power tool control with 2 no. 9A contactors and raise lower push button, incoming 35 sq.mm and outgoing 16 & 2.5Sq.mm terminals with outgoing mcbs 6 nos. |
| 68 | Supply, installation, testing and commissioning of Architectural designed Pole of 3mtr Height Post top pole made of galvanised iron sections of 114mm & 60mm dia. This architecturally designed pole is structurally sound. Windspeed considered in design 50m/s, IS875:PART 3:1987•Material for tubes steel of grade YST210.•Material for base plate steel of grade E250 to IS2062; 2011. The pole will be provided with an inbuilt junction box to fix 32Amp Connectors & 6Amp MCB inside the cut window of the bottom pipe the inbuilt box should have a flush door of suitable size with Allenkey locking on bothside. The Decorative pole will be mounted on a square base plate of size 200X200mm having 10mm thickness. The base plate shall have 4 hole suitable for M16/450 foundation bolts ensuring firm grouting in the specially designed RCC foundation. The galvanized zinc coat should not be less than 65+/ 10microns. The Galvanised pole should be painted in 3layer coating (Coating thickness should not be than 80microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy zinc primer & 3rd final layer with PU Paint with overall 100 +/- 10 microns. Including Foundation bolts, FRP connectors and MCB Preferred Make:- Suncity,Reytek, Havells, Leksa, La Luminite, Dwarka Casting , K-LITE as directed by the engineer incharge |
| 69 | Supply installation testing and commissioning of 40W decorative luminaire made of spun aluminium body withpressure die-cast heat management (PDCHM) and the IP65 opticalcompartment with high power LED/s is comprised of a deep drawnchemically polished and co-extruded, thermoformed polycarbonate protectorstabilized agent UV rays suitable for 50W LED. Fitting shall be Post topmounting type fixture. System Wattage: 50W LED, Protection class:IP65,Driver Integral: Constant Current, Input Voltage: 230-240 Vac, Frequency:50-60Hz, Operating Voltage:1200- 277Vac, Operating Temperature: 0deg to+50deg C, single phase ac supply.● light Source : Bridegelux, LEDLumens:6000lm, CRI(Ra):>80, LED Colour Temperature: 4000K, LifeSpan:>59,000 Hours,, ● Physical Body: Die cast Aluminium Base, BodySpun Aluminium, Diffuser: Convex Type Translucent / V TranslucentPolycarbonate glass, Mounting: Suitable for 48mm OD Pipe, Finish: PowderCoated Black, ●Driver Power Factor:>0.95, THD:<7.8%,Surge Protection:4KV, Efficiency:>87%. Fitting should have inbuilt driver with efficiency >0.9and having surge protection device of 4KVA and external surge protectiondevice of 10KVA make Philips. LED's of Osram & Driver to be of makePhilips. LM79-2019 report to be provided.(Preferred Make:-:- Suncity,Reytek, Havells, Leksa, La Luminite, Dwarka Casting , K-LITE as directed by the engineer incharge Please Enable Macros to View BoQ information |