| 1 | Excavation in Foundation |
| 2 | Excavation in foundations in ordinary soil (Loam clay or sand ) including lift up to 1.5 m and lead up to 30.0 meter and including filling, watering and ramming of excavated earth in to the trenches or into the space between the building and the sides of foundation trenches or in to the plinth and removal and disposal of surplus earth as directed by the Engineer- in charges up to a distance of 30 m from the foundation trenches |
| 3 | Cement Concrete |
| 4 | Providing and laying cement concrete in 1:6:12 (1 cement: 6 Fine sand: 12 Brick ballast 40 mm gauge) |
| 5 | Laying cement concret with cement, c.sand and 20 mm stone grit in 1:2:4 |
| 6 | RCC Work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 in lintels of door and window excluding supply of reinforcement and its bending, but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, Tools and plants etc. required foe proper completion of work including cost of binding wire. The rate excludes making of drip course which shall be paid extra. |
| 7 | 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) for Raft foundation and Footing And RCC Floor |
| 8 | RCC Work with cement, approved coarse sand and 2 cm gauge approved stone grit in proportions of 1:1.5:3 in lintels of door and window excluding supply of reinforcement and its bending, but including its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and supply of all materials, labour, Tools and plants etc. required foe proper completion of work including cost of binding wire. The rate excludes making of drip course which shall be paid extra. |
| 9 | 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) for Raft foundation and Footing And RCC Floor |
| 10 | Mild Steel work for reinforcement |
| 11 | First class brick work in 1:4 cement and coarse sand mortar in Foundation & Filling one brick thick including supply of all materials, labour and T & P etc. required for proper completion of work. |
| 12 | 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:3 (1 cement: 3 fine sand) |
| 13 | Providing and fixing 3 layer PP-(Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti -microbial fusion welded, having thermal stability for hot & cold water supply, including all PP -R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. External work PN10 Pipe, 110 mm OD (SDR-11) |
| 14 | Supply and Fixing RCC Frame and Cover on MH in Heavy duty 700x600 as required at site including all complete |
| 15 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction Engineer in Charge (Concealed work including cutting chases and making good the walls etc.) 25mm nominal outer dia Pipes |
| 16 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):(i) 25mm nominal bore |
| 17 | Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.(1) 32 Α, ΤΡΝ |
| 18 | Supplying and fixing of following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing as required. (But without MCB/RCCB/Isolator) etc.(i) 8 way (4+24), Double door Each |
| 19 | Wiring for circuit/ submain Rm. wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(i) 4 X 10 sq. mm + 2 X 6 sq. 1.7.1 mm earth wire meter |
| 20 | Supply, boring and fixing 1.50 HP single phase submersible pump including all T&P, labour, material, all connections and wiring as per atteched specifications and as per directed Engineer in Charge |
| 21 | Supply, boring and fixing 1.50 HP single phase submersible pump including all T&P, labour, material, all connections and wiring as per atteched specifications and as per directed Engineer in Charge |
| 22 | Supply and Fixing Elephant Combo of air compressor 30 Ltr. And 60ml Artmaster air Brusher With PU Pipe ad fitting (AC 30C-AC60) With hose pipe 5 Mtr.and as per specification given by engineer in charge |
| 23 | GST @ 18% Please Enable Macros to View BoQ information |