| 1 | DSR Item No.1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 Sq mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 Sq mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group-C |
| 3 | DSR Item No. 1.15Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. |
| 4 | Group-C |
| 5 | DSR Item No.1.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 6 | 3 x 1.5 Sq.mm |
| 7 | 3 x 2.5 Sq.mm |
| 8 | 3 x 4 Sq.mm |
| 9 | 4 x 6 sq. mm |
| 10 | DSR item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 25 mm |
| 12 | DSR item 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 13 | 5/6 Amp switch |
| 14 | 3 pin 5/6 Amp socket outlet |
| 15 | 15/16 A switch |
| 16 | 6 pin 15/16 A socket outlet |
| 17 | Bell Push |
| 18 | DSR item No.1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate asrequired. |
| 19 | DSR item No.1.27Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 20 | 4 Module (125mmX75mm) |
| 21 | 6 Module (200mmX75mm) |
| 22 | 8 Module (125mmX125mm) |
| 23 | 12 Module (200mmX150mm) |
| 24 | DSR item 1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. |
| 25 | 150 mm X 75 mm X 60 mm deep |
| 26 | 180 mm X 100 mm X 60 mm deep |
| 27 | 200 mm X 150 mm X 60 mm deep |
| 28 | DSR Item No. 1.33Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 29 | DSR item No 2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 30 | 8 way, Double door |
| 31 | Supplying and erection of MCCB BDB of following ways surface/ recess mounting, vertical type, MCCB 415 V, BDB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCCBs 4 pole with MCBs and incomer as required to complete the job. The job includes cost of all labour and other petty material required to complete the job to the entire satisfaction of Engineer in charge of the work. The make should be of Lauritz Knudsen/ Hager/ ABB/ Legrand/Schneider only. |
| 32 | 8 way (4 + 24), Double door |
| 33 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/ 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | Single pole |
| 35 | Double pole |
| 36 | DSR Item No. 2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 37 | DSR ITEM NO.2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 38 | DSR Item No. 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 39 | DSR Item No. 5.1Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 40 | DSR Item No. 5.12Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 41 | DSR Item No. 1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 42 | Supply and Erection of B.L Holder (ISI marked) of make Anchor Penta/ Havells (Reo)/ Goldmedal only on the existing junction box/ wooden block including making the connection etc as required. The job includes the all labour and petty material charges required to complete the job to the entire satisfaction of E.I.C. of work. |
| 43 | DSR 9.2 Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 44 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min(Minimum) |
| 45 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole in existing wall suitable size of above fan making in original shape of wall. The size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. |
| 46 | Size 15 inches (380mm) Sweep, 900 RPM Heavy Duty Exhaust Fan (Single Phase) with louver of Havells make (Turbo Force SP)/ Crompton make (EXHD380-6-1)/ Bajaj make (Supreme Plus)/ Orient make (Industrial Heavy Duty)/ Usha make (Turbo HDEF) make only. |
| 47 | S/E of M.S. angle iron board covered with 16 GMS sheet fixed in to the nitch for mounting switchgear. The switches/ BDB’s/ ELCB shall be provided with required no. of supporting member of M.S. flat 25mmx5mm to bring all the switchgear in one level including bonding the board switchgear etc. to the existing earth. The board shall be fabricated out of 40mmx40mmx5mm angle iron frame and shall be covered with a 16 GMS sheet duly welded for erection of switchgear items on it. The board shall be 2 coat of painted with approve shade of superior quality paint after one coat of primer. The rates includes carriage from factory to site, erection charges in the niche and other petty material required at site of work. |
| 48 | 8.10 LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver& electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 49 | 36 watt |
| 50 | Supply & Laying of PVC insulated sheathed aluminium conductor un armored cable 10 mm. sq. 2 core flat with 6 SWG G.I. earth wire on existing surface with suitable clamps / hanger etc. including making connection and petty material etc. as required. |
| 51 | 8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver& electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 52 | 150 watt |
| 53 | Supply and fixing of G.I box of size 200 mm x 150 mm suitable for accommodate the following accessories along with Modular switch with modular plate and cover for switches in recess / surface etc as required for Computer Point with 4 Nos. 5/6 Amp. Modular type switch and 4 Nos. 3 pin 5/6 Amp. Modular type socket outlet. The job includes the cost of making interconnections with suitable copper wire, painting of box with approved paint and other petty material required to complete the job to the entire satisfaction of Engineer-in-Charge at site. |
| 54 | 8.7 LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135lm/Watt)Supplying, installation, Testing & Commissioning of Panel light2x2 ft., of following body material and construction as per IS :10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, freq 50/60 hz,Operating temp range -5 deg to 40 deg centigrade, internalsurge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) < 19, Flicker free, (flicker should be below 5 %), lifetime (LED,Driver& electrical circuitary), of minimum 50000Burning Hours with , 70% of initial Lumen maintained till lifeends,CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin), SDCM (Standard Deviation Color Matching) <3,Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standardand trade mark certificate ( T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing.complete in all respect i/c external connections with 1.5 sqmm FRLS/HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 year OEMwarranty. System lumen efficacy ≥120 <135 lm/Watt output.LM79 & LM80 Test report and all testing required for LEDfixtures as per BIS shall be submitted. Shape size and CCTshall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing suchthat LED junction temperature shall not rise above 90°C).Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 55 | 36 watt |
| 56 | DSR 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 57 | 100 A,30KA,FPMCCB Please Enable Macros to View BoQ information |