| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Wiring for 2 way controlling light point with 3 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type 2 way switch, cover plate, surface modular switch board including connection etc as required:- |
| 6 | Long Point :- |
| 7 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 8 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 9 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 10 | 2 X 1.5 sq mm |
| 11 | 2 X 2.5 sq mm |
| 12 | 2 X 4 sq mm |
| 13 | 4 X 4 sq mm |
| 14 | 4 X 6 sq mm |
| 15 | 4 X 35 sq mm |
| 16 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 17 | 1 X 1.5 sq mm |
| 18 | 1 X 2.5 sq mm |
| 19 | 1 X 4 sq mm |
| 20 | 1 X 6 sq mm |
| 21 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 22 | 1-2 module plastic switch board:- |
| 23 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 24 | 1-2 module :- |
| 25 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 26 | 3/6 pin 16/20 amps socket outlet (2M):- |
| 27 | 20/25 amps single phase motor starter switch (2M):- |
| 28 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 29 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 30 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 31 | Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals. |
| 32 | Supply and fixing of the following sizes GI prong with necessary nuts & bolts etc as required grouted on roof for Lightning protection. |
| 33 | G.I Prong 1000 mm long |
| 34 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 35 | Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:- |
| 36 | Supplying & installation of 300 mm sweep 900 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 37 | Making different sizes of hole in the wall for fixing of exhaust fan including finishing the same with cement plastering and painting etc as required: |
| 38 | Supplying and fixing of following vertical storage water heater 5 star catagory complete with 15 amps top, connection pipes including necessary connection etc as required. |
| 39 | 25 litre storage capacity:- |
| 40 | Supplying and fixing of following luminaries complete with necessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
| 41 | Decorative wall mounting fancy bracket light fixture suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 42 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 43 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 44 | Recessed/Surface mounted 1ft x 1ft decorative 16/18 watt LED panel light with integral driver and high quality polycarbonate diffuser:- |
| 45 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 46 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 47 | 60 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 48 | 150 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 49 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 50 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 51 | 20 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 52 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 53 | 200/250 amps kitkat porcelain fuse unit with base(rewireable):- |
| 54 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 55 | (2+6) / 8 way SPN MCB DB (double door):- |
| 56 | (2+10) / 12 way SPN MCB DB (double door):- |
| 57 | 6 way horizontal TPN MCB DB (Double door):- |
| 58 | 8 way horizontal TPN MCB DB (Double door):- |
| 59 | 12 way vertical TPN MCB DB suitable for FP MCCB incomer upto 250 amps (Double door):- |
| 60 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 61 | 6 to 32 amps SP MCB:- |
| 62 | 6 to 32 amps DP MCB:- |
| 63 | 40/50/63 amps TP MCB:- |
| 64 | 40/50/63 amps FP MCB:- |
| 65 | Supplying & installation of Surge Protection Device (SPD) of following ratings in the existing Panels/MCB DBs including necessay connections etc as required:- |
| 66 | Surge Protection Device (SPD, withdrawable) (Type-2) with Imax 15 KA (3P+N) :- |
| 67 | Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):- |
| 68 | 250 amps FP MCCB, Breaking capacity 36KA (Thermal Magnetic) :- |
| 69 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 70 | 3 core 4 Sq mm |
| 71 | 3.5 core 95 Sq mm |
| 72 | Supplying and laying of following sizes XLPE insulated PVC sheathed copper conductor Un-armoured cable including necessary connection etc as required. |
| 73 | 3 core 1.5 Sq mm |
| 74 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : - |
| 75 | 50 sq mm |
| 76 | 95 sq mm |
| 77 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
| 78 | 1.5 sqmm - 4 sqmm Cable:- |
| 79 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 80 | 25 mm dia |
| 81 | Supplying & fixing of 40mmx6mm MS clamp for installation of ceiling fan/luminaries on cross bar including necessary accessories etc as required:- |
| 82 | Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- |
| 83 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 84 | Supplying and fixing of following Cable tray made of hot dip galvanised iron:- |
| 85 | 54 mm x 100 mm |
| 86 | 105mm x 150mm |
| 87 | Supplying, installation, testing and commissioning of following ratings inverter with Square/ sine wave technology, noiseless operation, inbuilt advance PCB programming, microprocessorwith all accessories including necessary connections etc. as required:- |
| 88 | 1500VA, 24V DC, 1 Ph input/1 Ph output inverter(Sine wave technology):- |
| 89 | Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:- |
| 90 | 12 V/ 200AH tall tubular/ flat plate Battery:- Please Enable Macros to View BoQ information |