| 1 | Supply, installation, Testing and commissioning of One (1) no. 50 KVA 415V, 3 phase, 50Hz Diesel Generator set with acoustic enclosure &AMF Control PanelatIMG Regional Centre, Kozhikode |
| 2 | OD23539/2023-2024 - SITC of 50 kVA Diesel Generator set complete with integral acoustic enclosure as per existing CPCB II norms and as per technical details given below 1. Engine a) Make of Engine - Cummins/ Kirlosker/Volvo/Catterpiller b) Type of Engine - Diesel Engine c) No. of Cylinders- 4. d) Method of Cooling – Liquid cooled with radiator. e) Aspiration -Turbo charged, charge air cooled. f) Design - Suitable for generating set operating. g) Output- As per manufactures standards. 2. Standard accessories with Diesel Engine. a) Fly wheel to suit flexible coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f) Mechanical governor g) Fuel filter h) Exhaust silencer i) Exhaust Muffler j) Lubricating oil filter. k) Battery Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or button. b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter. e) Battery charging Ammeter. 4. Safety Controls for Engine. a) Trip for low lubricating oil pressure. b) Trip for high water temperature. 5.Fuel pipe: Oil resistance flexible hoses of 20mm dia or nearest size MS pipe as per manufacturer's standard, 6 Brush less Alternator a) Make - Stamford/Kirlosker/KEL/LS b) Type - Self exited and self-regulated, brush less c) Capacity – 50 kVA/ 40 K W @ 0.8PF d) System of Voltage - 3 phase, 415 V, 4 wire system. e) Speed - 1500 rpm f) Voltage regulation band - +/-2.5% of rated voltage g) Frequency - 50 Hz h) Insulation - Class -F/H .The Alternator should confirm to IS 4722. Routine tests as per relevant ISS shall be conducted and test reports of the same shall be furnished at the time of delivery.Operation and service manual, spares and tools shall be provided. . 7.Fuel Tank Suitable size built in type integrated with the acoustic enclosure. Fuel connection shall be done as per standards.7. Battery. Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per Manufactures requirement. 8. Automatic Battery charger. Push button switch for ON/OFF - 1 set. Metallic DNB - 1No Solid state phase indication lamp for supply ON/OFF with HRC protection Supply of HSD for load test run, The standard Electric control panel integrated with acoustic enclosure comprising of the following. a) 125A,30/35KA,(63-80A rating) 4Pole MCCB having adjustable setting, b) Digital Multi function meter with accuracy class 1 to read parameters such as KW, KVA, PF, voltage, Current Frequency,Runing hour counter etc: c) Digital type single function KWH meter with accuracy class 1, d) LED type phase indication Lamp for indicating the presence of supply on all phases,10.Exhaust Piping ,Exhaust Piping shall be vent to the top of the nearest tallest building if required . If the pipe cannot be clamped/fixed to the building or any other structure of permanent nature necessary fabricated structures usingchannel section or angle iron sections of adequate mechanical strength, duly painted with 2 coats of Heat retardant aluminium paint shall be provided for the support of the exhaust pipe. (Additional piping will be measured excluding the standard length of pipe supplied by the manufacturer.),The DG set shall be tested as per relevant IS standards. Block load testing shall also be conducted. Droop characteristics shall also be tested and adjusted for enabling parallel operation. The load required for testing shall be made available at site by the selected agency at his own expenses.The DG shall be guaranteed for 3 years from the date of commissioning .Any of the spares /components which are found to be defective during this period shall be replaced immediately free of cost |
| 3 | 90.17.7.6 - Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia |
| 4 | OD23540/2023-2024 Providing Aluminum Claddings for DG Exhaust pipe |
| 5 | OD23541/2023-2024 Supply of High speed diesel (HSD) for fuel tank of DG set including conveyance, loading and unloading |
| 6 | Supply and installation AMF panel suitable 50KVA D.G fabricated from CRCA sheet as per IS 8623 approved design including bus bar relay and contactor/MCCB indication lamp push button Auto/ Manual Selector switch etc as required incluing 6 pair copper control cable from generator to panel Board |
| 7 | 90.16.1.6 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG) |
| 8 | 90.16.5.6 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG) |
| 9 | 90.12.7.29 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core70 sq mm with factory made clamp |
| 10 | 90.12.39.21 Supply & laying of one number PVC insulated and PVC sheathed armoured Auminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 70 sq mm |
| 11 | 90.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 12 | 90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 13 | 90.16.5.3 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 14 | 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 15 | 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 16 | 5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 17 | 9.1.20 Supplying and making end termination with brass compression gland and aluminium lugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2X70sq.mm (28mm) |
| 18 | 90.12.10.2 Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size |
| 19 | OD54965/2023-2024 Multifunction meter to read, Wh or VA, Vah or V AR, V ARh or PF - 3 phase accuracy class 1 LED. |
| 20 | OD54966/2023-2024 supply and fixing Red, Green, blue, yellow, orange colors LED indicator, AC/DC, as required |
| 21 | OD54967/2023-2024 Supply, Installation, Testing and commissioning of 250/5 A, 5 VA, accuracy class 1, Resin Cast Metering CT |
| 22 | OD23543/2023-2024 Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision. |
| 23 | OD23544/2023-2024 Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength. |
| 24 | Charges for preparation of Electrical Schematic diagram per A3 sheet for first copy, |
| 25 | OD23546/2023-2024 Copying charges of fire Drawing per A3 sheet additional copies |
| 26 | 14.10 Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 27 | OD213924/2024-2025 Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel |
| 28 | 14.12 Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 29 | Charges for getting Approval from Electrical inspectrate including necessary drawing Electrical inspectrate fees ete - LS Please Enable Macros to View BoQ information |