|
| 1 | Civil |
| 2 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonary and making good the damages to walls, flooring and jambs complete to match the existing surface including disposal to mulba/rubbish to the nearest municipal dumping ground,all complete as per the direction of Engineer-in-charge. |
| 3 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. |
| 4 | Providing and laying approved polished Granite stone In flooring , walls, skirting, steps, ramps and similar area with edge moulding where ever required all colours, shades ,design and patterns,thickness minimum 18-20mm laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. |
| 5 | 2.6 Earth work in excavation by mechanical means (Hydraulic excavator )/manual means over areas (exceeding 30 cm in depth ,1.5m width as well as 10 sqm on plane) including getting out and disposal of excavated earth lead upto 50m and for all lift,as directed by Engineer-in-charge 2.6.1 All kind of soil |
| 6 | Providing and laying in position plain cement concrete for levelling course for all works in foundations The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevent IS code machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lift ,cost of materials of quality ,labour |
| 7 | 4.1 providing and laying in position of cement concrete of specifed grade excluding the cost of centering and shuttering -All work up to plinth level:1:1.5:3 (1 cement ,1.5 coarse sand (zone II ) derived from natural sources : 3 graded stone aggregates 20mm nominal size derived from natural sources |
| 8 | Providing and laying cement concrete in retaining walls,return walls ,walls (any thickness ) including attached pilasters,column,piers,abutments,pillers,posts,struts,buttresses ,string or lacing courses ,parapets,coping,beams,bed blocks,anchor blocks,plain window sills, fillets,sunken floor etc up to floor five levels ,excluding the cost of centering ,shuttering and finishing 1:1.5:3 (1 cement ,1.5 coarse sand (zone II ) derived from natural sources : 3 graded stone aggregates 20mm nominal size derived from natural sources |
| 9 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. |
| 10 | 26.68 Providing and laying factory made precast concrete solid blocks of 200 mm thickness of grade M 10 made of C&D waste from approved manufacturer in foundation ,plinth and superstructure 26.98.1 cement morter 1:6 (1 cement :6 coarse sand ) |
| 11 | 26.64 Centering and shuttering with 12 mm thick shuttering plywood confirming to IS 4990:2011 and removal of form at all height .plywood will be supported on lock bars 26.64.1 Suspended floor,roofs ,retaining walls ,landings, balconies and access platform |
| 12 | Steel reinforcement for R.C.C work including supply ,installaing, straightening, cutting, bending, placing in position and binding all complete upto all levels (including all dia of bars )Thermo-Mechanically Treated bars of grade Fe-550D as per direction of Engineer-in-charge |
| 13 | 13.80 Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer ,over the plastered wall surface to prepare the surface even smooth and complete |
| 14 | Chemical Anchor Eastener: Providing and supplying approved injection adhesive with internally Threaded rod(16-20mm depth 150-200 mm).the product should be approved bt ETA,ICC,CSTB,COLA,BZS with shock approval,Seismic (C1,C2 ) approval ,Fatigue and Fire approvals in anchors to use in cracked concrete ,tested for service temperature of -40 deg .C to +80 deg. c. The chemical should have an ETA approval for 100 years age testing .Anchoring with approved chemical to be designed as per guidelines of TR 029 using manufactures Engineering software.Drilling hole with double flute type drill bits/ hollow drill bits to the required depth by rotary hammer drill,cleaning with brush and jet of clean air ,filling resin and hardner using serreted nozzel to eliminate mixing error with approved standard with piston plug.The installation and the setting instructions sholud be strictly followed as per the manufactures recommendations.All tools, labour, scaffolding and curing as per sire direction of Engineer-in-charge |
| 15 | Providing and fixing scaffolding system(cup lock type) on the exterior & interior side of buildings for all quaters upto 15 metre height above the ground level ,including additional rows of scaffolding in stepped manner as per requirement of site ,made with 40 mm dia M.S tube ,placed 1.5metre centre to centre ,horizondal & vertical tubes joint with cup & lock system with M.S tubes M.S tube challis M.S clambs and staircase system in the scaffolding for working platform etc and maintaining it in a serviceable condition for execution of work of cleaning and or pointing or applying chemical and removing it thereafter ,including material supply ,erection lead and lift etc complete. |
| 16 | Supply and installation,Testing & Commisioning (SITC) of 1nos of Passaenger Elevator Quantity 1 ( One ) unit(s)Model meta100 MRLAssembled Product Passenger ElevatorCapacity 13 persons, 884 kgSpeed 1.00 m/sStops & Openings 3 Stops, 3 OpeningsFloor designations G,1,2Machine type & Location meta100 MRL - Gearless machine located in the shaft on top of the guiderailsControl Simplex Collective Selective ControlDrive ACVVVFPower supply 415 volts (+10 / -15%), 3 phase, 50 Hz (+/- 5%), AC.Hoist way dimensions 1950mm wide x 2400mm deepCar travel 6700mmOverhead 4500mmPit depth 1500mmCar dimensions 1100 mm wide x 2000mm deep x 2200mm highDoor opening 800mm wide x 2100mm highCar door 2 panel automatic center opening door with ACVF drive in Stainless steel Silver Sky finishLanding door (Group1) 2 panel automatic center opening door in Stainless Steel Silver Sky finish on 3 floorsCar design PrimeCar flooring 20mm recess provided for granite/marble flooring (by customer)Handrail Round handrail in Stainless Steel finish provided on rear wall of carLanding operating panel Individual landing operating panel for each elevator |
| 17 | Supply and installation of Electrical works for the lift as per lift specifications which includes the electric materials,labour,lead,lift accessories etc., complete. |
| 18 | Lift License which is mandatory bidder have to get the license from concerned department and submitted to Client .The Central Electricity Authority (CEA) Lift License Certificate shall be included within the contractor’s scope of work. The contractor shall be fully responsible for obtaining all necessary approvals, inspections, and certifications from the CEA or relevant statutory authority before handover. |
| 19 | Supply and installation of Anti skid flooring mat which includes the lead,labour etc., complete. |
| 20 | Removal of Existing door and Design, supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts,non staining weather sealants of approved make,Teflon/ nylon bushes and separators to prevent bimetallic contacts, all complete to perform as per …….. temporary services all fitting fixers nut bolts, washer,Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment,actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. Please Enable Macros to View BoQ information |