| 1 | RMO of I.E.I works, Air conditioner, CCTV camera system, Wi-Fi router, Compound light, Firefighting i/c sprinkler system, Fire extinguisher, Fire alarm, PA system, Mechanical ventilation system, DG Set and Operation of lift at Aarambh Library (Community Hall) M-Block Vikaspuri, Community Hall BG-6 Paschim Vihar, Community Hall GH-9 Paschim Vihar and Community Hall GH-6 Paschim Vihar as per inventory, terms and conditions attached by deploying the following staff:-i) Operator Gr-II 1 No. in general shift on alternative days and as and when required for all the sites.ii) Operator Gr-I – 01 No. Electrician cum Operator for 6 AM to 2PM as and when required for aarambh library.iii) Operator Gr-I 01 no Technician cum Operator for 2 PM to 10 PM as and when required for aarambh library.iv) Khallasi-1 No. fortnightly for cleaning solar PV panel and other all E/M equipments as and when required for all the sites. (Note:- The agency shall arrange for obtaining NOC from Delhi Fire Service and renewal of lift license at community hall BG-6 Paschim Vihar as per term & condition attached.) |
| 2 | Supplying & replacement of following accessories/items i/c connection, installation, commissioning, testing etc. in all respect complete as required.2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 3 | 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 4 | 4 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor wire. |
| 5 | S.P. 5/6 amps, one way switch, piano type ISI marked. |
| 6 | S.P. 15/16 amps, one way switch, piano type ISI marked. |
| 7 | 6 pin 15/16 & 5/6 amps socket outlet, piano type ISI marked. |
| 8 | S.P. 5/6 amps, one way modular switch, ISI marked. |
| 9 | S.P. 15/16 amps, one way modular switch, ISI marked. |
| 10 | 6 pin 15/16 amps modular socket outlet, ISI marked. |
| 11 | 3 pin 5/6 amps modular socket outlet, ISI marked. |
| 12 | Stepped type Modular Fan regulator (1 module). |
| 13 | Stepped type Fan regulator (1 module) piano type. |
| 14 | Pvc batten 25x16mm. |
| 15 | 6 amps. to 32 amps. ratings , SP MCB, “C” curve, 10 KA breaking capacity. |
| 16 | 32 amps, DP MCB, “C” curve, 10 KA breaking capacity. |
| 17 | 100 Amp FP MCCB, 30kA breaking capacity. |
| 18 | 63Amps, DP MCB 'C' curve 10 KA breaking capacity. |
| 19 | 25 mm dia pvc conduit. |
| 20 | 3 pin, 5/6 amps socket outlet, piano type ISI marked. |
| 21 | Pvc flexible conduit 25mm. |
| 22 | Supplying & replacement of suitable size of phenolic laminated sheet 3mm thick cover in front etc. as reqd. i/c cutting for switches / socket, fixing of piano type switch, connection testing etc. as required. |
| 23 | Supplying and replacement following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door. |
| 24 | LED Batten light (System lumen efficacy >105<120lm/Watt)Supplying, installation, testing & commissioning of LED surface mounted Batten light of following body material and construction as per IS:10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating volatge AC 140-24 volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10% P.F.> 0.95, IP-20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000 K/ 4000K/ 5700K/6000K/6500K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and fixture shall be relevant BIS standard and trade mark certificate (T.C.). Manufacturer Word Mark/Name Engraved/Embossing/Screen printing on housing complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >105<120 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90OC). CRCA sheet body (thickness > 0.50mm)a) 18-22 watt |
| 25 | Supplying & replacement of following capacity of capacitor in the existing desert cooler/fan i/c connection, testing etc complete as required. a) 3.15 MFD |
| 26 | Brush Less Direct Current (BLDC) MotorSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos., canopies, shackle kit, safety rope, copper winding, steel/AI body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS: 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including saferty pin, nut bolts, washers, temperature rise = 75 degree C (max.) insulation resistance more than 2 mega ohm, suitbale for 230 V, 50 Hz, single phase AC Ceiling Fan complaint to IS 374:2019 fan supply, earhting etc. complete as req.a) 1200 mm, service value > 5.1 CM/Min/Watt, air delivery 130 CM/Min. |
| 27 | Supplying and replacement of 300 mm sweep size exhaust fan with complete in all respect with louvers suitable for single phase 230 volt,50 Hz AC supply i/c connection, testing etc. complete as required. |
| 28 | Supplying & replacement of suitable size polycarbonated double combined junction box i/c providing & fixing 2 no. 6 pin 5/6 & 15/16 amp socket outlet & 2 no. 15/16 piano type switch, connections etc. complete as required. |
| 29 | Internet recharge of wifi of router speed upto 300 mbps. |
| 30 | Supplying of high speed diesel for operation of DG set i/c cartage, storage, filling and arrangement of minimum 200 ltrs capacity tank at site in tank etc. complete as required. |
| 31 | Supplying of following sizes of XLPE insulated of 1.1 KV Grade Al. cond. armoured power cable including laying as per site requirement with clamping and saddling, connection, testing etc. as required.a)3.5 x35 sq. mm. |
| 32 | Servicing of 82.5 KVA D.G Set i/c replacement of lubrication oil, mobil oil, air filter, oil filter, coolant in radiator, diesel filter, battery terminal etc. complete as required. |
| 33 | Servicing & overhauling of 60 HP Electric driven Main fire Pump Set i/c greasing, painting and re-fixing the same after effecting necessary repairs / replacement of all internal defective parts etc., testing & commissioning, complete as required. |
| 34 | Servicing & overhauling of 60 HP Sprinkler pump set i/c greasing, painting and re-fixing the same after effecting necessary repairs / replacement of all internal defective parts etc., testing & commissioning, complete as required. |
| 35 | Servicing & overhauling of 72 HP Diesel driven fire pump set i/c painting, greasing, coolant topping, lube oil change, and re-fixing the same after effecting necessary repairs/replacement of all internal defective parts etc. testing & commissioning, complete as required. |
| 36 | Servicing & overhauling of 12.5 HP Electric Driven Jockey Pump Set i/c painting, greasing and re-fixing the same after effecting necessary repairs/ replacement of all internal defective parts etc. testing & commissioning, complete as required. |
| 37 | Servicing of 5.5 HP Clear water booster Pump Set i/c painting, greasing and re-fixing the same after effecting necessary repairs/ replacement of all internal defective parts etc. testing & commissioning, complete as required. |
| 38 | Servicing of 5.5 HP drinking water Pump Set i/c painting, greasing and re-fixing the same after effecting necessary repairs/ replacement of all internal defective parts etc. testing & commissioning, complete as required. Please Enable Macros to View BoQ information |