| 1 | Tender for Construction of SAA Building at Utkal Bala Ashram Baripada, Mayurbhanj, Odisha including Architectural Consultancy Services Tender for Construction of SAA Building at Utkal Bala Ashram Baripada, Mayurbhanj, Odisha including Architectural Consultancy Services NIT No: PCO/BBSR/1027/248 dated 18.04.2026 SUMMARY Sl. No. Description of Works Amount in Rs. |
| 2 | Civil Work (SAA Building) |
| 3 | Interior Work (SAA Building) |
| 4 | Civil Work (Toilet Renovation) |
| 5 | Civil Work (Kitchen Renovation) |
| 6 | Civil Work (Office Renovation) |
| 7 | Civil Work (Music Rm. Renovation) |
| 8 | Civil Work (Site Renovation) |
| 9 | Civil Work (Library) |
| 10 | Civil Work (Play Shed) |
| 11 | Electrical Work |
| 12 | PH work |
| 13 | Furniture Work (SAA Building) |
| 14 | Total (1 TO 12) |
| 15 | Architectural Consultancy Services Grand Total (13+14) 32068603.09 Say 32068603.0 Rupees: Three Crore Twenty Lakh Sixty Eight Thousand Six Hundred & Three Only Tender for Construction of SAA Building at Utkal Bala Ashram Baripada, Mayurbhanj, Odisha including Architectural Consultancy Services NIT No: PCO/BBSR/1027/248 dated 18.04.2026 SL.No. ITEMS DESCRIPTION UNIT QTY RATE AMOUNT (Rs.) SAA BUILDING EARTH WORK |
| 16 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.8 metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. ected by the Engineer in charge. a. All Kind of Soil CUM 214.04 206.06 44105.08 |
| 17 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed bythe Engineer-In-charge. |
| 18 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment). |
| 19 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge. CIVIL WORK |
| 20 | Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. |
| 21 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m. |
| 22 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. at all floors and all heights. a) Foundation CUM 31.11 8316.61 258729.74 b) Pedestal CUM 2.31 15823.22 36551.64 c) Column upto plinth lvl CUM 2.96 15823.22 46836.73 d) Plinth Beam CUM 21.59 8760.93 189148.48 e) Column from plinth lvl to 1st floor lvl CUM 8.64 15823.22 136712.62 f) Roof beam Ground floor roof CUM 11.46 17066.1 195577.51 g) Roof Slab Ground floor roof CUM 17.85 13403.28 239248.55 h) Column from 1st floor lvl to 2nd floor lvl CUM 8.64 15823.22 136712.62 i) Roof beam 1st floor roof CUM 11.45 17066.1 195406.85 j) Roof Slab 1st floor roof CUM 17.84 13403.28 239114.52 k) Column from 2nd floor lvl to 3rd floor lvl CUM 2.16 18552.3 40072.97 l) Roof beam 2nd floor roof CUM 1.67625 18552.3 31098.29 m) Roof Slab 2nd floor roof CUM 2.06 15089.7 31084.78 n) Lintel In ground floor CUM 1.82 12699.42 23112.94 o) Lintel In first floor CUM 1.82 13292.1 24191.62 p) Staircase In ground floor CUM 2.11 14475.68 30543.68 q) Staircase In first floor CUM 2.11 15512.6 32731.59 |
| 23 | Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only. a) Foundation Kg 3732.48 83.09 310131.76 b) Pedestal Kg 219.45 83.09 18234.1 c) Column upto plinth lvl Kg 562.25 83.09 46717.35 d) Plinth Beam Kg 2374.63 83.09 197308.01 e) Column from plinth lvl to 1st floor lvl Kg 1641.6 83.09 136400.54 f) Roof beam Ground floor roof Kg 2004.41 83.42 167207.88 g) Roof Slab Ground floor roof Kg 1962.91 83.42 163745.95 h) Column from 1st floor lvl to 2nd floor lvl Kg 1641.6 83.77 137516.83 i) Roof beam 1st floor roof Kg 2176.21 83.77 182301.11 j) Roof Slab 1st floor roof Kg 1962.91 83.77 164432.97 k) Column from 2nd floor lvl to 3rd floor lvl Kg 410.4 84.14 34531.06 l) Roof beam 2nd floor roof Kg 318.4875 84.14 26797.54 m) Roof Slab 2nd floor roof Kg 226.6275 84.14 19068.44 n) Lintel Ground Kg 191.31 84.53 16171.43 o) Lintel In first floor Kg 191.31 83.42 15959.08 p) Staircase In ground floor Kg 221.76 83.09 18426.04 q) Staircase In first floor Kg 221.76 83.42 18499.22 |
| 24 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with Pozolona Portland slag cement(PPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 25 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with Pozolona Portland cement(PPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. In ground Floor CUM 45.16 6252.44 282360.19 In first floor CUM 45.16 6581.5 297220.54 In Second floor CUM 7.80125 6959.9 54295.92 FINISHING WORK |
| 26 | 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. In ground Floor SQM 233.5 226.69 52932.12 In first floor SQM 233.5 232.17 54211.7 In Second floor SQM 30.87 237.81 7341.19 |
| 27 | 12mm cement plaster on internal RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 305.71 206.41 63101.6 In first floor SQM 312.53 211.08 65968.83 In Second floor SQM 36.1025 215.9 7794.53 |
| 28 | 16mm cement plaster on external smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 231.42 294.03 68044.42 In first floor SQM 228.56 305.69 69868.51 In Second floor SQM 73.6675 317.94 23421.84 |
| 29 | Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 770.63 80.15 61765.99 In first floor SQM 774.6 82.16 63641.14 In Second floor SQM 140.64 84.23 11846.11 |
| 30 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. In ground Floor SQM 231.425 81.5 18861.14 In first floor SQM 228.56 83.14 19002.48 In Second floor SQM 73.6675 84.86 6251.42 |
| 31 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 539.21 103.12 55603.34 In first floor SQM 546.04 105.02 57345.12 In Second floor SQM 66.9725 106.97 7164.05 |
| 32 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturer to make an even finished surface over a coat of primer with water bond cement primer, Putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. In ground Floor SQM 539.21 119.7 64543.44 In first floor SQM 546.04 121.8 66507.67 In Second floor SQM 66.9725 123.97 8302.58 |
| 33 | Providing and laying Vitrified flooring tiles 1200x600 mm (thickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 245.28 2136.46 524030.91 |
| 34 | Providing and laying Vitrified Skirting tiles 1200x600 mmthickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 24.53 1858.39 45586.31 |
| 35 | Providing and laying Matte Finish Vitrified floor tiles600x600 mm (thickness to be specified by themanufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, vory,grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. In ground Floor SQM 18.19 2234.62 40647.74 |
| 36 | Providing and fixing 1st quality Ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of approved make in all colours, shades except burgundy, bottle green, black of size 300x600 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including jointing in white cement mixed with pigment of matching shade complete as per direction of Engineer-In- charge. In all floors and all heights. In ground Floor SQM 88.37 1607.54 142058.31 |
| 37 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish and groove in staircase where required etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In ground Floor SQM 61.48 3305.9 203246.73 |
| 38 | Providing and laying grading conc. 40 mm (avg. thickness) cement concrete of required slope of mix 1:2:4 (1cement:2sand:4 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. |
| 39 | Providing & applying Waterproofing for Toilet/Sunken Slab: Surface Preparation & Crack Filling & Checking the leakage &seepage with pond testing - The surface shall be prepared by chipping all loose materials/mortar with wire brush or coir brush in order to remove all loose and deleterious matter, dust etc. (as per IS 1443-1972). If any cracks found cutting the cracks by 3mm/3mm & filling the same with Geolite Gel - epoxy mineral thixotropic gel with high wettablity and impregnation with excellent bonding to concrete, wood, steel, PVC etc. Junction treatment - All horizontal/vertical corners are treated with approved kerakoll Aquastop 120 - flexible NBR waterproof tape fixing with Nanoflex - single component, polymer modified, waterproofing adhesive.Joints sealing of all inlets and outlets pipes with the help of GEOLITE GEL. Application of 2 coats of NANOFLEX over the Roof mother slab and wall followed by aprotection screed (1:1.5:3) or tiles complete as per manufacturing specification and direction of Engineer-in-Charge. Make :- Kerakoll |
| 40 | Providing & applying Waterproofing for Roof Top Surface: Surface Preparation & Crack Filling & Checking the leakage &seepage with pond testing - The surface shall be prepared by chipping all loose materials/mortar with wire brush or coir brush in order to remove all loose and deleterious matter, dust etc. (as per IS 1443-1972). If any cracks found cutting the cracks by 3mm/3mm & filling the same with Geolite Gel - epoxy mineral thixotropic gel with high wettablity and impregnation with excellent bonding to concrete, wood, steel, PVC etc. Junction treatment - All horizontal/vertical corners are treated with approved kerakoll Aquastop 120 - flexible NBR waterproof tape fixing with Nanoflex - single component, polymer modified, waterproofing adhesive.Joints sealing of all inlets and outlets pipes with the help of GEOLITE GEL. Application of 2 coats of NANOFLEX over the Roof mother slab followed by aprotection screed (1:1.5:3) in pannel of size 2mtr *2mtr to drain the water towords the rain water pipe &finally filled the joints grooves(10mm*10mm) with fugabella Pu 40 complete as per manufacturing specification and direction of Engineer-in-Charge. Make :- Kerakoll |
| 41 | Providing, fitting, fixing UPVC Window of Fenesta make or equivalant with choukhat and 5mm reflective toughened glass alongwith locking arrangements and all requisite fitting including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P etc complete as per direction of Engineer-in-charge. |
| 42 | Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, i.e. Baan Code-LKYPDC527), 125x75x3mm (code no-7912) SS201 hinges, etc. of approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge |
| 43 | Providing and fixing factory made 3layers Wood polymer composite (WPC) Door Frame of the size 125 x 65mm with high density rigid solid wood polymer composite of 0.7D WPC foam sheet, mitre cut at two corners and joined and The two vertical door profiles are to be reinforced to horizontal member. The door frame shall be fixed to the wall using 6nos 150mm long M.S. holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work. |
| 44 | Providing and fixing M.S grill and structure of required patterns for windows/verandahs/rof etc. with M.S flats, square or round bars,box section and plate etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). |
| 45 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. |
| 46 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. SUB TOTAL SAA BUILDING 8754475.77 BOQ OF INTERIOR WORK FOR PROPOSED SAA BUILDING AT UTKAL BALA ASHRAM BARIPADA, MAYURBHANJ. |
| 47 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. |
| 48 | Providing and fixing and finishing Gypsum Board False Ceiling as per drawing made from 60mm x 36mm G.I. 'C' main supports suspended from the ceiling by means of 25 mmx 18 mm G.I suspenders fitted to the ceiling above with anchor fasteners and rowl plugs as required and as per design, having pattas/ concealed coves as indicated in drawings. Fixing 12.5 mm thick gypsum board on GI channels using good quality self-tapping screws, finishing and jointing two boards with adhesive and jointing tapes finished complete in lines and level including coves, providing cutouts for light fittings and extra frame work as necessary for ACgrills and/or any other cutouts etc. complete in all respects. Quoted rate to include cost of making opening for light fittings, grills, diffusers, etc. coves for fitting of diffused lights etc. as required and making good the same. Cost of additional frame required and as directed shall also be included). It may be noted that the vertical surfaces shall also be measured for payments and the quoted rates should take into account this area. |
| 49 | Providing & fixing Roller blind of black out quality to restric sunlight into the space with approve shade, texture & patten of approved makes for Mac / Marvel / Vista with necessary hardwares like pully, bearing thered and roller complete in all respect with all cost ,labour,T & P,Taxes etc as per direction of the Engineer - in - charge. |
| 50 | Supplying and fixing of wall paneling made of aluminium anodised section framing conforming to standrad aluminium section as horizontal and vertical memebers with atleast 600mm c/c with 0mm thick BWR block ply and 4mm thick veneer finished with melamine polished complete |
| 51 | Artistic painting on boundary wall including labour and material etc. complete as per direction of Engineer-In-Charge at all floors and all heights. SUB TOTAL INTERIOR WORK 1147622.45 BOQ OF CIVIL RENOVATION WORK (TOILET) FOR UTKAL BALA ASHRAM BARIPADA, MAYURBHANJ. CIVIL WORK |
| 52 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment). Sqm 108.8 180.0 19584.0 |
| 53 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m. CUM 29.76 1662.04 49462.31 FINISHING WORK |
| 54 | 12mm cement plaster on internal RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 108.8 206.41 22457.41 |
| 55 | 16mm cement plaster on external smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 161.7 294.03 47544.65 |
| 56 | Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 270.5 80.15 21680.58 |
| 57 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. In ground Floor SQM 161.7 81.5 13178.55 |
| 58 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 108.8 103.12 11219.46 |
| 59 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturer to make an even finished surface over a coat of primer with water bond cement primer, Putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. In ground Floor SQM 108.8 119.7 13023.36 |
| 60 | Providing and laying Matte Finish Vitrified floor tiles600x600 mm (thickness to be specified by themanufacturer) 1st quality conforming to IS: 15622 of approved make, colours & shades, except white, vory,grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement:4coarse sand) including pointing the joints with white cement and matching pigments, etc. complete as per direction of Engineer-In-Charge at all floors and all heights. In ground Floor SQM 112.553 2234.62 251513.18 |
| 61 | Providing and fixing 1st quality Ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) minimum thickness 5mm of approved make in all colours, shades except burgundy, bottle green, black of size 300x600 in skirting and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including jointing in white cement mixed with pigment of matching shade complete as per direction of Engineer-In- charge. In all floors and all heights. In ground Floor SQM 277.2 1607.54 445610.09 |
| 62 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish and groove in staircase where required etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In ground Floor SQM 8.35 3305.9 27604.27 |
| 63 | Providing, fitting, fixing UPVC Window of Fenesta make or equivalant with choukhat and 5mm reflective toughened glass alongwith locking arrangements and all requisite fitting including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P etc complete as per direction of Engineer-in-charge. sqm 21.6 9568.4 206677.44 |
| 64 | Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, 125x75x3mm (code no-7912) SS201 hinges, etc. of approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge SQM 35.28 12865.41 453891.66 |
| 65 | Providing and fixing factory made 3layers Wood polymer composite (WPC) Door Frame of the size125 x 65mm with high density rigid solid wood polymer composite of 0.7D WPC foam sheet, mitre cut at two corners and joined and The two vertical door profiles are to be reinforced to horizontal member. The door frame shall be fixed to the wall using 6nos 150mm long M.S. holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work. MTR 73.5 1947.2 143119.2 |
| 66 | Providing and fixing M.S grill and structure of required patterns for windows/verandahs/rof etc. with M.S flats, square or round bars,box section and plate etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). KG 504.0 146.6 73886.4 |
| 67 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. SQM 123.204 160.61 19787.79 |
| 68 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. KG 123.2 413.1 50893.92 |
| 69 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) 0.50 mm thick at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. To be measured and paid separately) as directed by the Enigineer In Charge SQM 108.8 807.2 87823.36 SUB TOTAL TOILET RENOVATION 1958957.63 BOQ OF CIVIL RENOVATION WORK (KITCHEN) FOR UTKAL BALA ASHRAM BARIPADA, MAYURBHANJ. CIVIL WORK |
| 70 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment). Sqm 83.168 180.0 14970.24 |
| 71 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m. CUM 25.536 1662.04 42441.85 FINISHING WORK |
| 72 | 12mm cement plaster on internal RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 131.4 206.41 27122.27 |
| 73 | 16mm cement plaster on external smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 196.56 294.03 57794.54 |
| 74 | Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 327.96 80.15 26285.99 |
| 75 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. In ground Floor SQM 196.56 81.5 16019.64 |
| 76 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 131.4 103.12 13549.97 |
| 77 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturer to make an even finished surface over a coat of primer with water bond cement primer, Putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. In ground Floor SQM 131.4 119.7 15728.58 |
| 78 | Providing and laying Vitrified flooring tiles 1200x600 mm (thickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 166.335 2136.46 355368.07 |
| 79 | Providing and laying Vitrified Skirting tiles 1200x600 mmthickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 16.634 1858.39 30912.46 |
| 80 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish and groove in staircase where required etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In ground Floor SQM 7.15 3305.9 23637.19 |
| 81 | Providing, fitting, fixing UPVC Window of Fenesta make or equivalant with choukhat and 5mm reflective toughened glass alongwith locking arrangements and all requisite fitting including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P etc complete as per direction of Engineer-in-charge. sqm 33.75 9568.4 322933.5 |
| 82 | Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, 125x75x3mm (code no-7912) SS201 hinges, etc. of approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge SQM 23.52 12865.41 302594.44 |
| 83 | Providing and fixing factory made 3layers Wood polymer composite (WPC) Door Frame of the size125 x 65mm with high density rigid solid wood polymer composite of 0.7D WPC foam sheet, mitre cut at two corners and joined and The two vertical door profiles are to be reinforced to horizontal member. The door frame shall be fixed to the wall using 6nos 150mm long M.S. holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work. MTR 45.5 1947.2 88597.6 |
| 84 | Providing and fixing M.S grill and structure of required patterns for windows/verandahs/rof etc. with M.S flats, square or round bars,box section and plate etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). KG 1914.6 146.6 280680.36 |
| 85 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. SQM 122.245 160.61 19633.77 |
| 86 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) 0.50 mm thick at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. To be measured and paid separately) as directed by the Enigineer In Charge SQM 99.75 807.2 80518.2 SUB TOTAL KITCHEN RENOVATIOON 1718788.67 BOQ OF CIVIL RENOVATION WORK (OFFICE) FOR UTKAL BALA ASHRAM BARIPADA, MAYURBHANJ. CIVIL WORK |
| 87 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment). Sqm 160.0 180.0 28800.0 FINISHING WORK |
| 88 | 12mm cement plaster on internal RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 160.0 206.41 33025.6 |
| 89 | 16mm cement plaster on external smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 252.0 294.03 74095.56 |
| 90 | Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 412.0 80.15 33021.8 |
| 91 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. In ground Floor SQM 252.0 81.5 20538.0 |
| 92 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 160.0 103.12 16499.2 |
| 93 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturer to make an even finished surface over a coat of primer with water bond cement primer, Putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. In ground Floor SQM 160.0 119.7 19152.0 |
| 94 | Providing and laying Vitrified flooring tiles 1200x600 mm (thickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 160.0 2136.461155548 341833.78 |
| 95 | Providing and laying Vitrified Skirting tiles 1200x600 mmthickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 16.0 1858.3942927425 29734.31 |
| 96 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish and groove in staircase where required etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In ground Floor SQM 25.2 3305.9 83308.68 |
| 97 | Providing, fitting, fixing UPVC Window of Fenesta make or equivalant with choukhat and 5mm reflective toughened glass alongwith locking arrangements and all requisite fitting including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P etc complete as per direction of Engineer-in-charge. sqm 48.33 9568.4 462440.77 |
| 98 | Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, 125x75x3mm (code no-7912) SS201 hinges, etc. of approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge SQM 30.24 12865.41 389050.0 |
| 99 | Providing and fixing factory made 3layers Wood polymer composite (WPC) Door Frame of the size125 x 65mm with high density rigid solid wood polymer composite of 0.7D WPC foam sheet, mitre cut at two corners and joined and The two vertical door profiles are to be reinforced to horizontal member. The door frame shall be fixed to the wall using 6nos 150mm long M.S. holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work. MTR 58.2 1947.2 113327.04 |
| 100 | Providing and fixing M.S grill and structure of required patterns for windows/verandahs/rof etc. with M.S flats, square or round bars,box section and plate etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). KG 2385.8 146.6 349758.28 |
| 101 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. SQM 37.08 160.608584 5955.37 SUB TOTAL OFFICE RENOVATION 2000540.39 BOQ OF CIVIL RENOVATION WORK (MUSIC ROOM) FOR UTKAL BALA ASHRAM BARIPADA, MAYURBHANJ. CIVIL WORK |
| 102 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment). Sqm 83.1675 180.0 14970.15 |
| 103 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m. CUM 25.536 1662.041286125 42441.89 FINISHING WORK |
| 104 | 12mm cement plaster on internal RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 131.4 206.41 27122.274 |
| 105 | 16mm cement plaster on external smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 161.7 294.03 47544.65 |
| 106 | Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 293.1 80.15 23491.97 |
| 107 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. In ground Floor SQM 161.7 81.5 13178.55 |
| 108 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 131.4 103.12 13549.97 |
| 109 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturerto make an even finished surface over a coat of primer with water bond cement primer, Putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. In ground Floor SQM 131.4 119.7 15728.58 |
| 110 | Providing and laying Vitrified flooring tiles 1200x600 mm (thickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 83.1675 2136.461155548 177684.13 |
| 111 | Providing and laying Vitrified Skirting tiles 1200x600 mmthickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 8.31675 1858.3942927425 15455.8 |
| 112 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish and groove in staircase where required etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In ground Floor SQM 7.15 3305.9 23637.19 |
| 113 | Providing, fitting, fixing UPVC Window of Fenesta make or equivalant with choukhat and 5mm reflective toughened glass alongwith locking arrangements and all requisite fitting including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P etc complete as per direction of Engineer-in-charge. sqm 33.75 9568.4 322933.5 |
| 114 | Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, 125x75x3mm (code no-7912) SS201 hinges, etc. of approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge SQM 23.52 12865.41 302594.44 |
| 115 | Providing and fixing factory made 3layers Wood polymer composite (WPC) Door Frame of the size125 x 65mm with high density rigid solid wood polymer composite of 0.7D WPC foam sheet, mitre cut at two corners and joined and The two vertical door profiles are to be reinforced to horizontal member. The door frame shall be fixed to the wall using 6nos 150mm long M.S. holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work. MTR 45.5 1947.2 88597.6 |
| 116 | Providing and fixing M.S grill and structure of required patterns for windows/verandahs/rof etc. with M.S flats, square or round bars,box section and plate etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). KG 1914.6 146.6 280680.36 |
| 117 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. SQM 122.25 160.608584 19634.4 |
| 118 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) 0.50 mm thick at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. To be measured and paid separately) as directed by the Enigineer In Charge SQM 99.75 807.2 80518.2 SUB TOTAL MUSIC ROOM RENOVATION 1509763.65 BOQ OF SITE RENOVATION WORK FOR UTKAL BALA ASHRAM BARIPADA, MAYURBHANJ. EARTH WORK |
| 119 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.8 metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. ected by the Engineer in charge. a. All Kind of Soil CUM 271.6 206.06 55965.9 |
| 120 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed bythe Engineer-In-charge. CUM 181.07 203.28 36807.91 |
| 121 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge. CUM 172.2 1105.39 190348.16 CIVIL WORK |
| 122 | Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. CUM 26.6 7183.0 191067.8 |
| 123 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. at all floors and all heights. a) Drain CUM 67.2 8316.61 558876.19 |
| 124 | Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only. a) Drain Kg 8063.73 83.09 670015.33 |
| 125 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with Pozolona Portland cement(PPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. In ground Floor CUM 32.73 6252.44 204642.36 FINISHING WORK |
| 126 | 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. In ground Floor SQM 31.1025 226.69 7050.63 |
| 127 | 16mm cement plaster on external smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 203.0 294.03 59688.09 |
| 128 | Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 3772.102 80.15 302333.98 |
| 129 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. In ground Floor SQM 3741.0 81.5 304891.5 |
| 130 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 31.1025 103.12 3207.29 |
| 131 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturer to make an even finished surface over a coat of primer with water bond cement primer, Putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. In ground Floor SQM 31.1025 119.7 3722.97 |
| 132 | Providing and fixing M.S grill and structure of required patterns for windows/verandahs/rof etc. with M.S flats, square or round bars,box section and plate etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). KG 4713.6 146.6 691013.76 |
| 133 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. SQM 2.52 160.61 404.74 |
| 134 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. KG 240.0 413.1 99144.0 |
| 135 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRCSP - 63:2018. SQM 280.0 608.4 170352.0 SUB TOTAL SITE RENOVATION 3549532.61 BOQ OF CIVIL WORK FOR PROPOSED LIBRARY BUILDING AT UTKAL BALA ASHRAM BARIPADA, MAYURBHANJ. EARTH WORK |
| 136 | Earthwork in excavation in all types of soil for site leveling, foundation, pits, trenches and other civil works upto and including 1.8 metre depth and stacking the soil upto a lead of 100 metre and including dewatering, removing slush,shoring and strutting (as required), complete as per specification and as directed by the Engineer-In-Charge. ected by the Engineer in charge. a. All Kind of Soil CUM 76.99 206.06 15864.56 |
| 137 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed bythe Engineer-In-charge. CUM 51.33 203.28 10434.36 |
| 138 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment). Sqm 27.44 180.0 4939.2 |
| 139 | Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-charge. CUM 24.0 1105.39 26529.36 CIVIL WORK |
| 140 | Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in foundation and plinth etc. including tempering, curring, shuttering etc. complete all depth and height. CUM 5.708 7183.0 41000.56 |
| 141 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m. CUM 14.52 1662.04 24132.82 |
| 142 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. at all floors and all heights. a) Foundation CUM 8.168 8316.61 67930.07 b) Pedestal CUM 1.485 15823.22 23497.48 c) Column upto plinth lvl CUM 1.17 15823.22 18513.17 d) Plinth Beam CUM 4.725 8760.93 41395.39 e) Column from plinth lvl to 1st floor lvl CUM 2.97 15823.22 46994.96 f) Roof beam Ground floor roof CUM 4.725 17066.1 80637.32 g) Roof Slab Ground floor roof CUM 4.7 13403.28 62995.42 h) Lintel In ground floor CUM 0.414375 12699.42 5262.32 |
| 143 | Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only. a) Foundation Kg 980.1 83.09 81436.51 b) Pedestal Kg 141.08 83.09 11722.34 c) Column upto plinth lvl Kg 181.35 83.09 15068.37 d) Plinth Beam Kg 590.625 83.09 49075.03 e) Column from plinth lvl to 1st floor lvl Kg 460.35 83.09 38250.48 f) Roof beam Ground floor roof Kg 732.375 83.42 61094.72 g) Roof Slab Ground floor roof Kg 611.52 83.42 51013.0 h) Lintel Ground Kg 58.01 84.53 4903.59 |
| 144 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with Pozolona Portland slag cement(PPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. CUM 2.205 6219.1 13713.12 |
| 145 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with Pozolona Portland cement(PPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. In ground Floor CUM 11.79 6252.44 73716.27 FINISHING WORK |
| 146 | 6 mm cement plaster on RCC surfaces at ceiling/slab soffit and other locations with cement mortar of mix 1:4 (1 cement : 4 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights. In ground Floor SQM 58.66 226.69 13297.64 |
| 147 | 12mm cement plaster on internal RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 51.9225 206.41 10717.32 |
| 148 | 16mm cement plaster on external smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 40.81 294.03 11999.36 |
| 149 | Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 151.39 80.15 12133.91 |
| 150 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. In ground Floor SQM 40.81 81.5 3326.02 |
| 151 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 110.5825 103.12 11403.27 |
| 152 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturer to make an even finished surface over a coat of primer with water bond cement primer, Putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. In ground Floor SQM 110.577 119.7 13236.07 |
| 153 | Providing and laying Vitrified flooring tiles 1200x600 mm (thickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 31.36 2136.46 66999.39 |
| 154 | Providing and laying Vitrified Skirting tiles 1200x600 mmthickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 2.24 1858.39 4162.79 |
| 155 | Providing and fixing 20mm thick Granite stone flooring (sample of Granite stone should be approved by EIC) for stair case trade, riser and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge etc. laid over 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish and groove in staircase where required etc. complete as per direction of Engineer-in-charge. In all floors and all heights. In ground Floor SQM 2.465 3305.9 8149.04 |
| 156 | Providing and laying grading conc. 40 mm (avg. thickness) cement concrete of required slope of mix 1:2:4 (1cement:2sand:4 graded stone aggregate of 10 mm nominal size) mixed with approved water proof compound as per manufacturer's specification on top of slab including cement slurry, all complete, including the cost of water proofing admixture, which should be approved by the Engineer-In-Charge prior to material procurement by the contractor. SQM 37.21 574.71 21384.96 |
| 157 | Providing & applying Waterproofing for Roof Top Surface: Surface Preparation & Crack Filling & Checking the leakage &seepage with pond testing - The surface shall be prepared by chipping all loose materials/mortar with wire brush or coir brush in order to remove all loose and deleterious matter, dust etc. (as per IS 1443-1972). If any cracks found cutting the cracks by 3mm/3mm & filling the same with Geolite Gel - epoxy mineral thixotropic gel with high wettablity and impregnation with excellent bonding to concrete, wood, steel, PVC etc. Junction treatment - All horizontal/vertical corners are treated with approved kerakoll Aquastop 120 - flexible NBR waterproof tape fixing with Nanoflex - single component, polymer modified, waterproofing adhesive.Joints sealing of all inlets and outlets pipes with the help of GEOLITE GEL. Application of 2 coats of NANOFLEX over the Roof mother slab followed by aprotection screed (1:1.5:3) in pannel of size 2mtr *2mtr to drain the water towords the rain water pipe &finally filled the joints grooves(10mm*10mm) with fugabella Pu 40 complete as per manufacturing specification and direction of Engineer-in-Charge. Make :- Kerakoll SQM 37.21 603.5 22456.24 |
| 158 | Providing, fitting, fixing UPVC Window of Fenesta make or equivalant with choukhat and 5mm reflective toughened glass alongwith locking arrangements and all requisite fitting including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P etc complete as per direction of Engineer-in-charge. sqm 13.367 9568.4 127900.8 |
| 159 | Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, i.e. Baan Code-LKYPDC527), 125x75x3mm (code no-7912) SS201 hinges, etc. of approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge SQM 10.9 12865.41 140232.97 |
| 160 | Providing and fixing factory made 3layers Wood polymer composite (WPC) Door Frame of the size125 x 65mm with high density rigid solid wood polymer composite of 0.7D WPC foam sheet, mitre cut at two corners and joined and The two vertical door profiles are to be reinforced to horizontal member. The door frame shall be fixed to the wall using 6nos 150mm long M.S. holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work. MTR 5.45 1947.2 10612.24 |
| 161 | Providing and fixing M.S grill and structure of required patterns for windows/verandahs/rof etc. with M.S flats, square or round bars,box section and plate etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). KG 294.03 146.6 43104.8 |
| 162 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. SQM 43.15 160.61 6930.32 |
| 163 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. KG 76.8 413.1 31726.08 SUB TOTAL LIBRARY BUILDING 1429893.64 BOQ OF CIVIL WORK FOR PROPOSED PLAY SHED BUILDING AT UTKAL BALA ASHRAM BARIPADA, MAYURBHANJ. CIVIL WORK |
| 164 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 25 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. at all floors and all heights. a) Column from 1st floor lvl CUM 5.1 15823.22 80698.42 b) Roof beam 1st floor roof CUM 9.457 17066.1 161394.11 c) Lintel In 1st floor CUM 3.108 12699.42 39469.8 |
| 165 | Cutting,Straightening coiled or bent up M.S plain HYSD/TMT reinforcement bars welding or jointing if necessary bending,binding,tying the grills as required for R.C.C works,providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance,loading, unloading & taxes of M.S plain/HYSD/TMT reinforcement bars and binding wires of 18 to 20 gaugo required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S plain/HYSD/TMT reinforcement bars consumed in the work only. a) Column from 1st floor lvl Kg 1020.0 83.42 85088.4 b) Roof beam 1st floor roof Kg 1654.89 83.42 138050.92 c) Lintel In 1st floor Kg 295.26 83.42 24630.59 |
| 166 | First class Fly ash Brick masonry using bricks of size 25cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with Pozolona Portland cement(PPC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. In ground Floor CUM 23.398 6252.44 146294.59 FINISHING WORK |
| 167 | 12mm cement plaster on internal RCC/brick surfaces in cement plaster 1:6 (1 cement : 6 coarse sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 119.53875 206.41 24673.99 |
| 168 | 16mm cement plaster on external smooth side of RCC/brick surfaces with cement mortar of mix 1:6 (1 cement : 6 fine sand) including necessary scaffolding, curing etc. all complete at all floors and all heights as direction of Engineer-In-charge. In ground Floor SQM 153.03 294.03 44995.41 |
| 169 | Providing & Applying priming coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 272.57 80.15 21846.49 |
| 170 | Providing and applying to outside walls with two or more coats of Anti-Fungal Weather coat water proofing paint including scaffolding and cleaning the surface before application of approved colour and manufacture as per specification, instruction of Engineer-In-Charge at all elevations including all material labour complete. In ground Floor SQM 153.03 81.5 12471.95 |
| 171 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. In ground Floor SQM 119.53875 103.12 12326.84 |
| 172 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) interior grade of approved make & shade manufactured by reputed manufacturer to make an even finished surface over a coat of primer with water bond cement primer, Putty in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. In ground Floor SQM 119.53875 119.7 14308.79 |
| 173 | Providing and laying Vitrified flooring tiles 1200x600 mm (thickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 200.12 2136.46 427548.38 |
| 174 | Providing and laying Vitrified Skirting tiles 1200x600 mmthickness to be specified by the manufacturer) 1st quality of approved make, colours & shades laid on 12 mm thick cement mortar 1:3 (1cement: 3coarse sand ) including pointing the joints with matching epoxy grout , etc. complete as per direction of Engineer-In- Charge at all floors and all heights. In ground Floor SQM 5.71 1858.39 10611.41 |
| 175 | Providing, fitting, fixing UPVC Window of Fenesta make or equivalant with choukhat and 5mm reflective toughened glass alongwith locking arrangements and all requisite fitting including cost, conveyance, loading, unloading and taxes of all materials, cost of all labour, T&P etc complete as per direction of Engineer-in-charge. sqm 48.84 9568.4 467320.66 |
| 176 | Providing, fitting and fixing of approved make 35mm thick (laminate finished thickness of the door) factory made flush doors of the followings size finished with 1mm thk. laminate of approved colour & shade to both side fixed to the teak wood bidding, complete in all respect bidding/lipping as per drawing/design. The door will be provided with all necessary fittings & fixtures, 125x75x3mm (code no-7912) SS201 hinges, etc. of approved make with all materials, labour, T&P, taxes etc. as per direction of Architect/Engineer-in-Charge SQM 10.9 12865.41 140232.97 |
| 177 | Providing and fixing factory made 3layers Wood polymer composite (WPC) Door Frame of the size125 x 65mm with high density rigid solid wood polymer composite of 0.7D WPC foam sheet, mitre cut at two corners and joined and The two vertical door profiles are to be reinforced to horizontal member. The door frame shall be fixed to the wall using 6nos 150mm long M.S. holdfastners through the frame by using etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work. MTR 5.45 1947.2 10612.24 |
| 178 | Providing and fixing M.S grill and structure of required patterns for windows/verandahs/rof etc. with M.S flats, square or round bars,box section and plate etc. including applying a coat of approved steel primer and two or more coats of synthetic enamel paint of approved make & shade, all complete as per drawing & specification. (All steel sections contractor's own supply). KG 4781.53 146.6 700972.3 |
| 179 | Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete. SQM 133.163 160.61 21387.31 |
| 180 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand ralling using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm X 32mm X 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm X 32mm X 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes, all materials, labour, T&P etc. required for the complete in all respect. KG 76.8 133.14 10225.15 |
| 181 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) 0.50 mm thick at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. To be measured and paid separately) as directed by the Enigineer In Charge sqm 252.0 807.2 203414.4 SUB TOTAL PLAY SHED 2798575.12 INTERNAL ELECTRICAL WORKS I WIRING-: |
| 182 | Recess Wiring for light point/ fan point/ exhaust fan/wall fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with 1way modular switch, modular plate, suitable GI box including supplying the same and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required including the cost of labor & material T & P as required as EIC. First Point a Group A point 60.0 586.0 35160.0 b Group B point 45.0 881.0 39645.0 c Group C Point 25.0 1255.0 31375.0 d 2way point point 0.0 586.0 0.0 Looping Point .(Looping Point) (Controled by same switch-Gr.A wire Only) point 68.0 498.0 33864.0 |
| 183 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required including the cost of labor & material T & P as required as EIC. a 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for 6A PP & 80W bay Light looping & inverter wiring. Metre 450.0 166.0 74700.0 b 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire for 15A PP & Switch Boards & Computer points Metre 650.0 180.0 117000.0 c 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire for AC & Geyser Point. Metre 80.0 205.0 16400.0 d 2 X 6.0 sq. mm + 1 X 4 sq. mm earth wire forToilet DB & UPS wiring. Metre 0.0 235.0 0.0 e 4 X 4 sq. mm + 2 X 2.5 sq. mm earth wire for L .DB Metre 0.0 280.0 0.0 f 4 X 6 sq. mm + 2 X 4 sq. mm earth wire for C.DB Metre 0.0 343.0 0.0 g 4 X 10 sq. mm + 2 X 6 sq. mm earth wire for P.BDB,. Metre 0.0 476.0 0.0 h 4 X 16 sq. mm + 2 X 10 sq. mm earth wire for P.BDB Metre 0.0 662.0 0.0 i 2 X 10.0 sq. mm + 1 X 6.0 sq. mm earth wire AC Point. Metre 0.0 301.0 0.0 |
| 184 | Supplying and drawing following pair 0.5 sq mm FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required including the cost of labor & material T & P as required as EIC. 2 Pair Metre 0.0 58.0 0.0 |
| 185 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required including the cost of labor & material T & P as required as EIC. |
| 186 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as requiredincluding the cost of labor & material T & P as required as EIC. a 25 mm Metre 74.0 170.0 12580.0 |
| 187 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required including the cost of labor & material T & P as required as EIC. a 20 mm Metre 100.0 128.0 12800.0 b 25 mm Metre 100.0 130.0 13000.0 c 32 mm Metre 60.0 138.0 8280.0 |
| 188 | Supplying and fixing metal box of 1.63 mm thick following sizes (nominal size) on surface or in recess without cover including cutting the wall and making good the same in case of recessed conduit ,also including painting etc as required including the cost of labor & material T & P as required as EIC. a 75 mm X 75 mm X 60 mm deep Each 12.0 148.0 1776.0 b 100 mm X 100 mm X 60 mm deep Each 6.0 159.0 954.0 c 150 mm X 75 mm X 60 mm deep Each 4.0 165.0 660.0 d 200 mm X 125 mm X 60 mm deep Each 4.0 210.0 840.0 e 250 mm X 300 mm X 60 mm deep Each 4.0 332.0 1328.0 8-a Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required including the cost of labor & material T & P as required as EIC. Each 60.0 537.0 32220.0 b Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3nos 3 pin 5/6 amps modular socket outlet with 2nos 5/6 amps modular switch, connection etc. as required including the cost of labor & material T & P as required as EIC. Each 20.0 1271.0 25420.0 c Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2nos 3 pin 5/6 amps modular socket outlet with 2nos 5/6 amps modular switch, connection etc. as required. Each 8.0 941.0 7528.0 |
| 189 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 10-a Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular switch, connection etc. as required including the cost of labor & material T & P as required as EIC. Each 6.0 481.0 2886.0 b Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular Socket , connection etc. as required including the cost of labor & material T & P as required as EIC. Each 6.0 585.0 3510.0 |
| 190 | Supplying and fixing of Telephone socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required including the cost of labor & material T & P as required as EIC. |
| 191 | Supplying and fixing of TV antenna socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required including the cost of labor & material T & P as required as EIC. |
| 192 | Installation, testing and commissioning of wall bracket /ceiling fittings /LED down light of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required including the cost of labor & material T & P as required as EIC. |
| 193 | Supplying and fixing brass batten/ angle holder including connection etc. as requiredincluding the cost of labor & material T & P as required as EIC. |
| 194 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 195 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required including the cost of labor & material T & P as required as EIC. |
| 196 | Installation, testing and commissioning of ceiling fan on down rod or wall fan on the existing ceiling /surface, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required including the cost of labor & material T & P as required as EIC. |
| 197 | Installation of exhaust fan with shutters/louvers in the existing opening, including making good the damage, connection, testing, commissioning etc. as required including the cost of labor & material T & P as required as EIC. Upto 450 mm sweep Each 14.0 872.0 12208.0 |
| 198 | Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required including the cost of labor & material T & P as required as EIC. |
| 199 | Supplying and fixing of support arrangement for fixing of cable tray, light fittings ,Panel Board etc with MS angles / flats / rods /anchor flashner/extra rod for fan & Lights including jointing the steel sections of the support arrangement with nuts & bolts / welding / Febicating complete as required including the cost of labor & material T & P as required as EIC. SUB TOTAL WIRING 523672.0 II SDB'S, MCB, ISOLATOR,CABLE,PANELS-: |
| 200 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as requiredincluding the cost of labor & material T & P as required as EIC. (But without MCB/RCCB/Isolator) a 4 way (4 + 12), Double door Each 2.0 2235.0 4470.0 b 6 way (4 + 18), Double door Each 4.0 2578.0 10312.0 0.0 |
| 201 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required including the cost of labor & material T & P as required as EIC.. (But without MCB/RCCB/Isolator) a 8 way (2 + 6), Double door Each 0.0 1701.0 0.0 b 12 way (2 + 6), Double door Each 0.0 1973.5 0.0 0.0 0.0 |
| 202 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required including the cost of labor & material T & P as required as EIC. a Single pole Each 35.0 149.0 5215.0 0.0 |
| 203 | Supplying and fixing following rating, four pole, (three phase andneutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required including the cost of labor & material T & P as required as EIC. a 25amps Each 0.0 2300.0 0.0 b 63amps Each 8.0 2704.0 21632.0 c Supplying and fixing 40A rating, single pole, 240volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required including the cost of labor & material T & P as required as EIC. Each 0.0 1959.0 0.0 0.0 |
| 204 | Supplying the following Size ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required including the cost of material T & P as required as EIC. a 3 core 6 sq.mm mtr 0.0 180.0 0.0 b 4 core 10 sq.mm- mtr 0.0 216.0 0.0 c 4 core 16 sq.mm- mtr 0.0 260.0 0.0 d 3 1/2 core 25 sq.mm mtr 400.0 360.0 144000.0 e 3 1/2 core 70 sq.mm- mtr 0.0 779.0 0.0 0.0 |
| 205 | Laying and fixing of one number of following size of cable on wall surface as required, ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required a Upto 25 sq. mm mtr 25.0 115.0 2875.0 b Above 25 sq. mm and upto 120 sq. mm mtr 0.0 171.0 0.0 0.0 |
| 206 | Laying and fixing of one number .following size cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. ISI mark Aluminum/copper conductor, XLPE insulated cable, FRLS PVC, galvanized steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - I) with latest amendments & complete all as required a upto 25 sq. mm mtr 305.0 175.0 53375.0 b Above 25 sq. mm and upto 120 sq. mm mtr 0.0 201.0 0.0 0.0 |
| 207 | Supplying and making end termination with brass compression gland and aluminium lugs/copper for following size of PVC insulated and PVC sheathed / XLPE aluminium/copper conductor cable of 1.1 KV grade as required including the cost of labor & material T & P as required as EIC.. a a- 4 core 10 sq.mm nos 0.0 231.0 0.0 b a- 4 core 16 sq.mm nos 0.0 246.0 0.0 c a- 3 1/2 core 25 sq.mm nos 12.0 431.0 5172.0 d a- 3 1/2 core 70 sq.mm nos 0.0 500.0 0.0 0.0 0.0 0.0 |
| 208 | Panels . Design, supply, installation, testing and commsioning of cubicle main panel for indoor/Outdoor installation of wether prrof design as per IP 44 class, made out of 2 mm thick CRCA sheet as per the drawing with cubicle type inernal arrangement of 1.6 mm thick sheet and with front & back opening system suitable for mounting following switch gears, busbars, metering unit, including painting with powder coated paint of approved colour and shed with earthing the body etc as reqd including the cost of labor & material T & P as required as EIC.(drawing shall be approved by engineer -in charge) 0.0 |
| 209 | Main Panel Board = (Indoor Floor mounted type-) Incommer:- 01 no. 125A., 25KA FP MCCB 0.0 Busbar:- 04 nos. 200A. Al. bus bar duly sleeved. 0.0 Outgoing:-i)63A FP ,10KA, MCB-3nos ,63A., 16KA FP MCCB-1, 32A FP ,10KA, MCB-4nos , 40A SPN ,10KA, MCB-1nos 0.0 32A DP ,10KA, MCB-4nos 0.0 Instrument:- i) 03 nos. phase indicating lamp with control MCB 0.0 ii) 01 Set of (0-125)A CT Coil 0.0 ii) 01 Set of MFM Digital Meter 0.0 (Duly factory wired) 0.0 0.0 |
| 210 | External Light Panel Board = (Outdoor Floor mounted type-) Incommer:- 01 no. 63A., 16KA FP MCCB ,TIMER with Contactor for auto on/Off 0.0 Busbar:- 04 nos. 100A. Al. bus bar duly sleeved. 0.0 Outgoing:-i)32A FP ,10KA, MCB-2nos , 0.0 10-16A SPN ,10KA, MCB-12nos 0.0 Instrument:- i) 03 nos. phase indicating lamp with control MCB 0.0 ii) 01 Set of 0-500V Voltmeter 0.0 (Duly factory wired) 0.0 0.0 |
| 211 | Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete including the cost of labor & material T & P as required as EIC. 0.0 |
| 212 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall including the cost of labor & material T & P as required as EIC.. 0.0 |
| 213 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required including the cost of labor & material T & P as required as EIC.. a 100 mm dia mtr 15.0 542.84 8142.6 b 150 mm dia mtr 0.0 593.68 0.0 Sub Total Cost = 534739.6 III Earthing |
| 214 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including the cost of labor & material T & P as required as EIC. 0.0 |
| 215 | Earthing with CU earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including the cost of labor & material T & P as required as EIC. 0.0 |
| 216 | Supplying and laying 25 mm x 5 mm CU earth strip ISI marked at 0.5 meter below grond level as strip arth electrode including soldering etc. as required including the cost of labor & material T & P as required as EIC. 0.0 |
| 217 | Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked at 0.5 meter below grond level as strip earth electrode including soldering etc. as required including the cost of labor & material T & P as required as EIC. Sub Total Cost = 21974.0 IV FITTING & FIXTURE INTERNAL-: |
| 218 | Supplying of of PVC Exhaust fan 250 mm dia suitable to work on 230/250 volts, 50HZ complete with mounting Frame and louvers including making the hole to suit the size of above fan, making good the damage, connections, with 1.5 sq.mm PVC insulated, copper conductor, single core cable etc as per EIC of approved makeincluding the cost of labor & material T & P as required as EIC. 0.0 2a Supplying of 1200 mm sweep ceiling fan ,BEE 5star Rated, Brush Less direct current(BLDC)motor,class of Insulation:B , 3nos Blade,30cm long Rod,2nos canopies,shakel kit,safety rope,copper winding, Power factor not less than 0.9, service value (CMM/W) minimum 6.85 ,Air deliver minmum 215 CMM ,350 RPM (tolearance as per IS-2019).THD not less than 10% with Remote for speed control remaining all other accessories like safety pin, nut bolts,washer, temperture rise 75degree C. max,insulation resitance more than 2-Megaohm suitable for single phase 230v,50Hz AC supply ,earthing including the cost of labor & material T & P as required as EIC. each 35.0 2730.0 95550.0 0.0 b Supplying of two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required including the cost of labor & material T & P as required as EIC. Each 35.0 349.0 12215.0 0.0 |
| 219 | Supply, Installation, Testing, and commissioning of 400mm sweep energy efficient Wall mounted fan complete with 1.5 sq.mm PVC insulated, copper conductor,single core cable etc as requiredincluding the cost of labor & material T & P as required as EIC. 0.0 |
| 220 | Supplying of surface mountedsqure warm White LED downlighter including 12W LED fitting of approved make including the cost of labor & material T & P as required as EIC. 0.0 |
| 221 | Supply, Testing & commissioning of Surface or wall mounting 1 x 20W LED tube light fitting including 1 no. of 20watt LED luminairs as per EIC of approved make including the cost of labor & material T & P as required as EIC. 0.0 |
| 222 | Supply, Testing & commissioning of Surface or wall mounting 1 x 10W LED tube light fitting including 1 no. of 10watt LED luminairs as per EIC of approved make including the cost of labor & material T & P as required as EIC. 0.0 |
| 223 | Supply, Testing & commissioning of wall mounting 1 x 10W LED wall mounted IP-65 bulk head / Outdoor wall light fitting including 10watt LED luminairs (4000K)as per EIC of approved make including the cost of labor & material T & P as required as EIC. 0.0 |
| 224 | Supplying of Recess /Surface mounted squre LED Luminaire (6000K)with high efficiency complete diffuser with for 1 x36W LED inluding of approved make including the cost of labor & material T & P as required as EIC. 0.0 |
| 225 | Supplying of recess mounted round White LED downlighter with pressure die cast aluminium housing & PMMA diffuser suitable for 12W LED fitting includded luminairs (6000K)of approved make including the cost of labor & material T & P as required as EIC. 0.0 |
| 226 | Supply, of recess mounted round Warm White LED COB spot downlighter with aspecial frosted diffuser suitable for 6W LED fitting including 6 watt LED luminairs (3000K)of approved make including the cost of labor & material T & P as required as EIC. 0.0 |
| 227 | Supply, Installation,Testing & commissioning of indoor Flexible Warm White LED strip Light of 15W/Spool with Driver for cove light(3000K)including the cost of labor & material T & P as required as EIC. 0.0 |
| 228 | Supply, Testing & commissioning of LED recess mounted under canopy light including 80W LED fitting (3000K) including the cost of labor & material T & P as required as EIC. Sub Total Cost = 508032.0 V Data Networking,WIFI,CCTV System |
| 229 | Supply and laying of Cat6 4-pair 23AWG UTP Cable in the existing ISI marked PVC conduits for data and voiceincluding the cost of labor & material T & P as required as EIC. 0.0 |
| 230 | Supply, installation and commissioning of RJ-45Jack of Category 6 with Single-port British-style Face plate 86x86 mm with Curveture and Wall Mout Box l(G.I/PVC) , to be fixed in concealed manner in partition/wall by necessary bolts & nuts including the cost of labor & material T & P as required as EIC. 0.0 |
| 231 | Supply and Installation of Cat6 24-port loaded, Modular Jack Panel having 24-port individually replaceable module including the cost of labor & material T & P as required as EIC. 0.0 |
| 232 | Supply, installation of Cat6 UTP 24AWG LSZH Patch Cord as required including the cost of labor & material T & P as required as EIC. For 1 mtr. Long No. 22.0 245.0 5390.0 For 2 mtr. Long No. 22.0 270.0 5940.0 0.0 |
| 233 | Supplyand Installation of 9U/500D Wall mounting Server Rack with FAN, 6skt 6/16AMP PDU, Horizontal manager and H/W Screw Pk t.including the cost of labor & material T & P as required as EIC. 0.0 6-a Supply and Installation of 24portt PoE 10/100/1000Mbps Managed Switch with Two Combo ports and minimum PoE power budget of 370W, Support IPv6 management, CLI/ WEB/ SNMP Management including 3years product warranty including the cost of labor & material T & P as required as EIC. No. 2.0 48500.0 97000.0 0.0 b Supply and Installation of 24portt 10/100/1000Mbps Managed Switch with Two Combo ports including 3years product warranty including the cost of labor & material T & P as required as EIC. No. 1.0 38100.0 38100.0 0.0 |
| 234 | Supply and Installation of Dual band 802.11ac Wave2 2x2 MU-MIMO indoor WiFi-6 AP with inbuilt Mobility Express image for adopting 100 AP as centralised Wireless Controller without any extra licence and hardware supporting Gigabit 802.11 af n at PoE interface and console port including the cost of labor & material T & P as required as EIC. 0.0 |
| 235 | Termination & link testing of LAN cable at both the end including the cost of labor & material T & P as required as EIC. 0.0 |
| 236 | Supply and Installation of Indoor Dome IR Network Camera (1/2.7\\" CMOS sensor, Mini. Pixel of 2560*1920 or higher video quality, frame rate of Up To 25fps @ 4MP, H.265, H.264 & MJPEg video compression, 2.8mm Fixed lens, physical ICR filter of both day and night, 30mtr IR Distance,120dB WDR ,3Streams Supported, WDR , 3D-DNR for noise reduction, BLC, ICR, EXIR, Audio In and Out, Alam in and Out. IPv4/IPv6 network supported, IP67, IK10 rated for weatherproofing, ONVIF ver 2.2 or higher, PoE IEEE 802. 3af (UL, FCC, CE, BIS certified.) including the cost of labor & material T & P as required as EIC. 0.0 |
| 237 | Supply and Installation of Indoor Bullet IR Network Camera (1/2.7\\" CMOS sensor, Mini. Pixel of 2560*1920 or higher video quality, frame rate of Up To 25fps @ 4MP, H.265, H.264 & MJPEg video compression, 2.8mm Fixed lens, physical ICR filter of both day and night, 30mtr IR Distance,120dB WDR ,3Streams Supported, WDR , 3D-DNR for noise reduction, BLC, ICR, EXIR, Audio In and Out, Alam in and Out. IPv4/IPv6 network supported, IP67, IK10 rated for weatherproofing, ONVIF ver 2.2 or higher, PoE IEEE 802. 3af (UL, FCC, CE, BIS certified.) including the cost of labor & material T & P as required as EIC. 0.0 |
| 238 | Supply and Installation of 16CH NVR Support 12MP/8MP / 5MP / 4MP / 3MP / 1080P / 960P IP Adopt standard H.265 high profile compression format, With 4k Video Output, Compression Standard H.265, Network Access Bandwidth 320Mbps, HDD SATA × 8(Upto 10TB Supported), 1- e-SATA And 2-way Audio RCA × 1, Local Output RCA × 1, USB 2.0 × 2 (one in the front panel and the other in the rear panel), USB 3.0 × 1 (rear panel) (UL, FCC, CE, BIS certified) including the cost of labor & material T & P as required as EIC. |
| 239 | SITC of 4 TB Storage Capacity,including the cost of labor & material T & P as required as EIC. 0.0 |
| 240 | Supply and Installation of 43\\" UHD (3,840 x 2,160) TV with 300 nits brightness,10W+10W Audio Output,Crestron Connected®, NTP sync timer, BEACON, Embedded CM (contents manager), Soft AP, WiFi , Screen Share (Miracast), DIAL, Bluetooth Audio Playback,Hotel Mode , Welcome Screen (Splash Image), Insert Image, One Channel Map, IP Channel Manager, External Speaker Out , Remote jack pack, Moving Picture Playback, Auto Off / Sleep Timer,Smart Energy Saving, Motion Eye Care,USB Cloning, WOL, Interface : Set Side - HDMI In 3, USB 1, CI Slot, RF In, Digital Audio Out (Optical), RS-232C, RJ45 , External Speaker Out,Power Consumption(Typ.)-145 W, with 3years Warranty including the cost of labor & material T & P as required as EIC. 0.0 |
| 241 | SITC of IP Based PoE Phone, 2 SIP accounts, 2 line keys, 3-way conferencing, 3 XML programmable context-sensitive soft keys, Dual-switched 10/100 mbps ports, integrated PoE, HD audio on speakerphone and handset including the cost of labor & material T & P as required as EIC. Sub Total Cost = 972320.0 VI 6 KVA UPS |
| 242 | Supply, Installation ,testing, and commissioning of 6kVA true online double conversion UPS system having 1 Ph. 230 V AC, 50 Hz Input & 230V ,50Hz 1Ph AC Output, comes with inbuilt Isolation Transformer. including 15 Minuets Backup. (Battery 12V* 18AH-16 numbers 3456VAH)(Warranty: 1 Year/APC/Numeric) including Battery for 15 minutes back up: 16 nos 12V*18AH Battery for 15 Minutes Backup including Rack & InterlinksHSN code: 8507. Warranty: 1 Year and other connecting accessories including the cost of labor & material T & P as required as EIC.. Supply, Installation ,testing, and commissioning of 6kVA true online double conversion UPS system having 1 Ph. 230 V AC, 50 Hz Input & 230V ,50Hz 1Ph AC Output, comes with inbuilt Isolation Transformer. including 15 Minuets Backup. (Battery 12V* 18AH-16 numbers 3456VAH)(Warranty: 1 Year/APC/Numeric) including Battery for 15 minutes back up: 16 nos 12V*18AH Battery for 15 Minutes Backup including Rack & InterlinksHSN code: 8507. Warranty: 1 Year and other connecting accessories including the cost of labor & material T & P as required as EIC.. No. 1.0 162126.0 162126.0 Sub Total Cost = 162126.0 VII AIRCONDITIONING SYSTEM-: |
| 243 | Supplying of Hi Wall type split air-conditioning units suitable for operation on 230±10% volt, 50 Hz, 1 phase power supply, with air-cooled evaporator with coil, fan, and fan motor, air-cooled condenser with hermetically sealed rotary / scroll compressor/Gas/Remote/Control Cable etc . a 1.0 TR ( Invereter - 5* ) Nos. 2.0 53325.0 106650.0 b 1.5 TR ( Invereter - 5* ) Nos. 8.0 60480.0 483840.0 c 2.0 TR ( Invereter - 5* ) Nos. 0.0 82080.0 0.0 0.0 |
| 244 | Supply of Inverter 3-Star, 1-Ph wiring Cassette units including compressor, condenser, supports, with cordless remote controller, etc as per the specifications of the following capacities. Cassette unit shall be 4-way. Cassette units shall have supply and return air grill and have drain pump /Gas/Remote/Control Cable etc. a 2.0 TR Nos 0.0 112000.0 0.0 0.0 0.0 INSTALLATION ,TESTING & COMMISSIONING-: 0.0 0.0 |
| 245 | Testing,Commissioning of Hi-Wall Unit 0.0 |
| 246 | Testing and Commissioning of Cassette air conditioners 0.0 |
| 247 | Supplay, Installation, Testing & Commissioning of the Copper refrigerant pipes with 13mm/9mm with nitrile rubber tube insulation & control cable for Hi-wall Unit 0.0 |
| 248 | SITC of Soft copper piping for Cassette ac units , clamping, fittings, etc. Both the pipelines shall be insulated with nitrile tubular insulation, shall be of Class \\"O\\". Exposed piping insulation . 0.0 |
| 249 | SITC of PVC drain pipes with 6 mm nitrile rubber insulations complete with supports as per drawings and specifications of below sizes.including all cost of labour ,material, conveyance,taxes (excluding GST) ,T & P etc. complete and as per the directions of Engineer-in-charge. a 25mm inner dia(for Split) Rmt 150.0 391.0 58650.0 b 32mm inner dia(for Cassettet) Rmt 0.0 446.0 0.0 0.0 |
| 250 | Supply, Installation, Testing and Commissioning of Flexible drain pipe 0.0 |
| 251 | SITC of FRLS PVC insulated copper conductor, PVC sheathed Aluminum armoured control cable of 1.1 KV grade confirming to IS:7098 Part-I ISI marked. including all cost of labour ,material, conveyance,taxes (excluding GST) ,T & P etc. complete and as per the directions of Engineer-in-charge. 4C x 1.5 sq. mm Rmt 120.0 244.0 29280.0 0.0 |
| 252 | Making grooves in brick walls vertically and horizontally to the required depth and width for fixing of copper and drain pipes,for MS Brackets and filling the grooves with cement mortar (1:4) to bring te surface to original level including the cost of materials, curing and conveyance of materials etc all complete as per the direction of Engineer In Charge. 0.0 |
| 253 | Supply of ODU Bracket for AC, vibration pads Sub Total Cost = 798120.0 Total Electrical Works 3520983.6 PH WORK A INTERNAL WATER SUPPLY & SANITATION WORKS - |
| 254 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Ground Floor i 32 mm dia Mtr 43.2 554.0 23932.8 ii 20 mm dia Mtr 193.624 279.0 54021.1 First Floor 0.0 i 32 mm dia Mtr 28.8 554.0 15955.2 ii 20 mm dia Mtr 63.962 279.0 17845.4 Terrace 0.0 i 50 mm dia Mtr 178.38 1159.0 206742.42 0.0 |
| 255 | Supplying all materials, Labour, T & P & fitting and fixing of following different water supply fitting as per ASTMD-2846 with supply of all necessary joint materials etc all complete as per direction of engineer-in-charge i 50mm dia UPVC ball valve Each 4.0 3340.0 13360.0 ii 32mm dia UPVC ball valve Each 12.0 1637.0 19644.0 iii 25mm dia UPVC ball valve Each 2.0 795.0 1590.0 0.0 |
| 256 | Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete 15mm to 32mm dia pipe 0.0 Ground Floor Mtr 193.624 225.0 43565.4 First Floor Mtr 63.962 225.0 14391.45 0.0 |
| 257 | Providing and Fixing water closet, squatting pan (Indian type W.C pan) conforming to IS 2556 : Part 32004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification i Porcelain 20\\" I.W.C (Orissa Pan) 0.0 Ground Floor Each 12.0 3222.0 38664.0 First Floor Each 0.0 3222.0 0.0 |
| 258 | Providing and Fixing in cement mortar (1:3) a pair of foot rest for I.W.C Pan Ground Floor Each 12.0 707.0 8484.0 First Floor Each 0.0 707.0 0.0 |
| 259 | Providing and Fixing 100mm size ‘P’ or ‘S’ trap (with horn or without horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1) as per specification. Ground Floor Each 12.0 418.9 5026.8 First Floor Each 0.0 418.9 0.0 |
| 260 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. Ground Floor Each 12.0 1951.4 23416.8 First Floor Each 0.0 1951.4 0.0 |
| 261 | Providing & Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification i PORCELAIN E.W.C WITH S-TRAP (POPULAR) COLOUR Each 12.0 4471.0 53652.0 |
| 262 | Fixing PVC Standard seat cover (Colour) for wash down water closet with chromium plated brass hinges and rubber buffers all complete as per specification |
| 263 | Providing and fixing P.V.C. 10 litre capacity (low level ) (Colour) ( with fittings, accessories and flush pipe) with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. Ground Floor Each 12.0 2219.6 26635.2 |
| 264 | Providing and Fixing wash basins with hole for pillar taps confirming to IS 2556 Part 4-2004 with cast iron or M.S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification Below counter Wash Basin 0.0 Ground Floor Each 10.0 3935.0 39350.0 First Floor Each 10.0 3935.0 39350.0 |
| 265 | Providing and Fixing PVC waste pipe with fittings of following nominal diameter for wash basin or sink including brass check nut complete as per specification. Ground Floor Each 10.0 125.0 1250.0 First Floor Each 10.0 125.0 1250.0 0.0 |
| 266 | Providing and Fixing Chromium Plated brass waste coupling of the following nominal diameter for wash basin and sink as per specification Ground Floor Each 10.0 381.0 3810.0 First Floor Each 10.0 381.0 3810.0 |
| 267 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (24\\" x 18\\" x 10\\" steel sink single blow (Parrware) |
| 268 | Providing and Fixing PVC 32mm x 1150mm long waste pipe with fittings of following nominal diameter for wash basin or sink including brass check nut complete as per specification. Ground Floor Each 2.0 125.0 250.0 |
| 269 | Providing and Fixing Chromium Plated brass waste coupling of the following nominal diameter for wash basin and sink as per specification Ground Floor Each 2.0 329.0 658.0 0.0 |
| 270 | Supplying all materials, labour, taxes,T&P for fitting & fixing of different water supply CP, Brass or GM concealed fitting and fixtures of ISI approved make of following sizes and specification with leak proof threaded joints tightened with spun yam and white zinc or any other method as required and directed including testing and rectification of defects after testing,including cost of all labours,materials,conveyance,loading and unloading,all taxs and royalies, sundries and T&P etc all compete as per direction of the Engineer-in-charge. i Pillar Cock Nos 20.0 901.0 18020.0 ii 2 in 1 Bib cock Nos 24.0 1299.0 31176.0 iii Angular stop cock Nos 45.0 923.0 41535.0 iv CP Health Faucet with 1.01 RM PVC tube Nos 24.0 810.0 19440.0 v Soap Dish Nos 24.0 320.0 7680.0 vi Towel Ring Nos 15.0 553.0 8295.0 vii TOWEL RAIL Nos 24.0 1015.0 24360.0 viii GLASS SHELF Nos 20.0 730.0 14600.0 ix Bathroom mirror 600x600 mm Nos 20.0 1393.48 27869.6 x Toilet paper Holder Nos 12.0 373.0 4476.0 xi Sink Cock Nos 2.0 1977.0 3954.0 xii SHOWER ARM Nos 19.0 211.0 4009.0 xiii OVERHEAD SHOWER Nos 19.0 450.0 8550.0 xiv Longbody Bibcock Nos 19.0 980.0 18620.0 xv Concealed stop cock Nos 19.0 1995.0 37905.0 xvi CP Flange small Nos 109.0 27.93 3044.37 xvii 110mm dia pvc nahani trap without jally Nos 45.0 132.55 5964.75 xviii CP extension piece Nos 129.0 111.19 14343.51 xix CP Grating Nos 45.0 47.89 2155.05 0.0 |
| 271 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 272 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expension,(i) Single socketed pipes. 110MM OD P.V.C SWR S/S PIPE(ISI TYPEA) Mtr 100.8 374.0 37699.2 |
| 273 | Supply all material, labour ,T&P ,fitting and fixing UPVC SWR Type B pipes & fitting of approved make conforming to IS-13592 including jointing of approved solvent cement non-heat application method including testing of as per stanard specification, both below & above ground level/floor & on walls including supply of bobbins,nains,screws,wooden cleant,pipe clamps as per requirement including cutting walls & floor & making good the damages with cement concrete (1:2:4) with hard granite chips, including scaffolding wherever necessary all complete with requisite testing as per direction of the EIC i 75mm dia OD PVC SWR S/S PIPE (ISI TYPE-B) 0.0 Ground Floor Mtr 66.785 362.0 24176.17 First Floor Mtr 62.485 362.0 22619.57 ii 110mm dia OD PVC SWR S/S PIPE (ISI TYPE-B) 0.0 Ground Floor Mtr 118.1775 543.0 64170.38 First Floor Mtr 85.0 543.0 46155.0 iii 110mm p.v.c s/j with door Nos 6.0 228.77 1372.62 iv 110mm p.v.c swr plain bend 87.5 Nos 6.0 140.03 840.18 v 110mm pipe clip Nos 347.0 24.93 8650.71 vi 110mm dia p.v.c vent cowl Nos 3.0 34.45 103.35 vii 110mm dia p.v.c swr coupler Nos 28.0 91.87 2572.36 viii 110mm dia p.v.c Y with door Nos 4.0 412.64 1650.56 ix 110x110x110 mm dia pvc swr Tee Nos 10.0 196.66 1966.6 0.0 |
| 274 | Providing and fixing pvc gully trap compete with grating brick masonry chamber with water tight SFRC cover with frame of 300*300 mm size(inside)the weight of cover to be notless than 4.50kg and frame to be not less than 2.70kg as per standard design:100*100 mm size P type .including cost of all labours,material,conveyance,loading and unloading,all taxes and royalties,sundries and T&P etc all complete as per direction of the Engineer-in-change. With flyash bricks of minimum compressive strength 75 kg/sqcm (Size 300 x 300 x 300 mm) Nos 8.0 2882.3 23058.4 |
| 275 | Constructing brick masonary chamber for underground SFRC inspection chamber and bends with brick in cement mortar 1:4 (1 cement :4 coarse sand )SFRC cover with frame 455*610mm internal dimensions ,total weight of cover with frame be not less than 38kg (weight of cover 23kg and weight of frame 15 kg), R.C.C TOP SLAB WITH 1:2:4mix(1 cement:2 coarse sad:4 graded stone aggregate 20mm nominal size ),foundation concrete 1:5:10(1 cement :5 fine sand :10 graded stone aggregate 40mm nominal size)insideplastering 12mm thick with cement mortar 1:3(i cement:3 coarse sand),finished smooth with a floating coat of neat cement on walls and bed concrete etc.compete as per standard design Including all cost of labour,material,T&P etc.all compete as per the engineer-in-charge. Inside dimensions 600*850mmand 45cm deep for pipe line with three or more inlets. Nos 9.0 6928.9 62360.1 0.0 |
| 276 | Supplying Blue Star Fully Stainless Steel body Water Cooler Model - PC - 151503T (1 Plain & 2 Cold) Storage Capacity -150 Litres, Cooling Capacity - 150 Litres etc all complete as per the direction of Engineer-in-charge. 0.0 |
| 277 | Supplying, laying, jointing,fitting and fixing, testing and commission-ing uPVC foam core structured pipes confirming to IS certification with SN4 or SN8 Solvent Cement joints with or without rubber ring for Soil Pipes and coupler complete for external sewerage system, including supply of bobbins, nails, screws, wooden cleats, pipe clamps as per requirement.including cost of all labours, materials, conveyance, loading and unloading, all taxes and sundries and T&P etc all complete as per direction of the Engineer -in-charge. a) 160 mm dia UPVC S/S SN-8 Foam Core Pipe Mtr 138.281 1395.07 192911.67 0.0 |
| 278 | Constructing RCC manhole in with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 6 mm thick with cement mortar 1:4 (1 cement : 4 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : all complete as per the direction of Engineer in charge. Inside size 90x80 cm and 45 cm deep including CI Cover with frame 455x610 mm internal diameter, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) Nos 2.0 11015.52 22031.04 0.0 |
| 279 | Providing and laying in trench cement concrete ( 1:4:8 ) with 40mm size hard granite metal in the following type of surrounding or encasing salt-glazed stoneware pipes of the following internal diameter including concrete for bedding and curing complete as per PH specification . 0.0 |
| 280 | Supplying all materials,labour,T&P and fixing PVC water storage tanks of as required capacity confirming to IS:12701-1996 including cutting holes through the tank and fixing pvc pipe and fittings and providing extre sockets and jam nuts,fixing ball valve etc,including conveyance of all materials to work site etc all complete as per specification and direction of Engineer-in-charge.(Sintex/Equivalent) TOTAL 1848917.18 SAY 1848917.0 RCC SEPTIC TANK WORK inner size 5.4x2.4x1.85m Liquid depth of 2 year cleaning interval. |
| 281 | Earth Work: a) Earth work in ordinary soil with initial lead and lift including rough dressing in layers not exceeding 0.3m in depth and the Earth transported by transport vehicles as directed by the Engineer-in-charge. i) Upto 1.50m initial lift Cum 40.154 473.632 19018.22 ii) From 1.50m to 3.00m lift Cum. 4.514 473.632 2137.97 |
| 282 | Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour , T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC. 2/3rd rate of respective item of work Cum 26.775 151.802 4064.5 |
| 283 | Filling the pipe line trenches with sand including watering & ramming etc. complete including all labour, T&P, cost of sand, conveyance, taxes, royality, loading & unloading as per specification & direction of EIC. Cum 3.564 677.998 2416.38 |
| 284 | Cement concrete (1:3:6) with 12mm size hard broken granite chips. Cum 2.376 6113.0 14524.49 |
| 285 | R.C.C. work M-25 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting and laying with Centering & shuttering. RCC base Cum 2.0 7616.25 15232.5 RCC / Baffle wall Cum 6.207 13599.63 84412.9 RCC Slab Cum 1.62 11823.65 19154.31 |
| 286 | Providing M.S. reinforcement for R.C.C. work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge. Take 0.88qntl/cum of concrete for all RCC works Qntl 10.81 9200.081 99452.88 |
| 287 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment. Per 1 Sqm Sqm 31.896 179.779 5734.23 |
| 288 | Providing plaster with cement mortar including cement punning/ bitumen painting where required finished smooth over brick work with waterproofing cement based compound of approved quality including finishing smooth to proper slope and plane including cost of all materials with conveyance, royalty, taxes, watering, scaffolding and curing, all labour and T&P etc. complete as per specification & direction of EIC. 12mm thick C.P. 1:4 with punning Sqm 38.047 163.14 6206.99 |
| 289 | Providing, fitting & fixing of following sizes of precast factory made RCC man hole cover with frame including locking arrangement. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. 500mm dia clear opening RCC man hole cover with frame.(medium duty) No. 2.0 1263.0 2526.0 |
| 290 | Providing, fitting & fixing of Poly Propylene man hole steps of approved quality & size in two parallel line of 300mm spacing in vertical walls with centre to centre 375mm (staggered).The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. |
| 291 | Providing, fitting & fixing of 110 diax1.80m long UPVC SWR pipe (Type-A) of approved make confirming to IS-13592/1992 with Vent Cowl including construction of cement concrete pedestal (1:2:4) of size 0.30mx0.30mx0.45m ht. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. |
| 292 | Providing, fitting & fixing of 150mm dia S.W. Tee. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. |
| 293 | Providing all labour, T&P for benching & making Channel for inlet & outlet chamber. ---------------- Total Rs. 279659.67 TOTAL PH WORKS 2128576.85 FURNITURE WORK SL ITEM UNIT QTY RATE TOTAL LOBBY |
| 294 | RECEPTION TABLE |
| 295 | SOFA 2 SEATER PISA |
| 296 | CENTRE TABLE, PISA |
| 297 | SIDE TABLE, PISA DINNING AND KITCHEN 0.0 |
| 298 | DINNING TABLE |
| 299 | DINNING CHAIR |
| 300 | PANTRY TABLE |
| 301 | MODULAR KITCHEN DORIMITORY - 1 NEW BORN 0.0 |
| 302 | LUVLAP BABY WOODEN COT WITH DETACHABLE NEWBORN CRADLE C-80 |
| 303 | CUPBOARD .9mx1.2m STAFF ROOM 0.0 |
| 304 | SIDE TABLE |
| 305 | CUPBOARD PLAY AREA 0.0 |
| 306 | OK PLAY FUNSTATION MODEL NO.8 (SKU: OKP_FNSP_08) |
| 307 | OK PLAY 3 IN 1 SLIDE ALONG WITH ROCKER & BASKET BALL – EASY TO ASSEMBLE & USE. (1-7 YEARS) (SKU: FGD0006149) |
| 308 | OK PLAY PENGUIN SWING (SKU: FTFT000416) |
| 309 | Ok Play Coaster Car l ATV Style Push Ride On Toy Car For Toddler 2-4 Age Kids (Green Colour) |
| 310 | OK PLAY BABY SLIDE SENIOR – YELLOW/RED (SKU: FTFT000015) OFFICE ROOM 0.0 |
| 311 | TABLE |
| 312 | CHAIR |
| 313 | VISITOR CHAIR |
| 314 | ALMIRAH |
| 315 | WORKSTATION Table |
| 316 | CHAIR LOBBY 0.0 |
| 317 | SOFA 2 SEATER PISA |
| 318 | CENTRE TABLE, PISA |
| 319 | SIDE TABLE, PISA DORIMITORY - 3 0.0 |
| 320 | Marge Kids Bed with Storage | (72x36 inch) | Engineered Wood Kids Single Bed with Underbed Storage |
| 321 | CUPBOARD .9mx1.2m STAFF ROOM 0.0 |
| 322 | SIDE TABLE |
| 323 | CUPBOARD SICK ROOM 0.0 |
| 324 | TABLE |
| 325 | CHAIR |
| 326 | VISITOR CHAIR TOTAL 1312168.0 Architectural Consultancy Services Architectural Consultancy Services Lot 1.0 238724.09 238724.09 TOTAL 238724.09 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail