| 1 | Part-l: Erection 11KV OH 3Ph 3W Line with AAAC-55mm2 -0.5KM with 11mtr WPB, Cradle Gard @ Road Crossing -2No.s WPB 160x1S2 (30.44KG/Mtr.),11mtr as per RE Specification including cost of all material, labour, labourcess, T&P, taxes, conveyances ,contigency,salvage etc. Complete required for the work as per direction of the Engineer-in-charge |
| 2 | Straight Cross Arm Channel 100X50X6mm, 9.2 KG/Mtr., each channel lenxth 1.2 mtr. |
| 3 | Straight Cross Arm Top Channel 100X50X6mm,9.2 KG/mtr, each channel length 0.306 Mtr. |
| 4 | Fish Plate 50X8 mm., 3.14kg/Mtr., each 0.280 mtr. Length |
| 5 | Danger Plate, 1no |
| 6 | Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1no |
| 7 | GI barbed wire anticlimbing device 3 Kg. Persupport |
| 8 | Back Clamp for anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's |
| 9 | 11KV,5KN pin insulator polymer |
| 10 | 11kV V cross Arm (GI) |
| 11 | GI Back Clamp for 11kV 'V’ Cros Arm |
| 12 | Top bracket 100X50X5mm GI channel |
| 13 | HW fitting(T&C) 45 KN |
| 14 | Disc insulator(B&S)45 KN polymer |
| 15 | Earthing of Support ( Coil Tyee I |
| 16 | No-8 Gi wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtrs For connecting pole with Coil earthing |
| 17 | PG Clamp for 55 mm2 AAAC conductor |
| 18 | GI Nut , Bolt & Washer of different sizes |
| 19 | H.T. Stay clamp |
| 20 | H.T. Stay set (Complete ) |
| 21 | H.T. Stay insulator |
| 22 | 7/10 SWG Stav Wire |
| 23 | AAA conductor,55 mm2 |
| 24 | Black Paint |
| 25 | Yellow Colour Paint for Background |
| 26 | Sunderies |
| 27 | Guarding @ Road Crossing -2 No.s Guarding cross arm of 75X40X6mm GI Channel 2.2 mtr long 4Nos @7.14Kg/mtr |
| 28 | No. 10 GI wire cross lacing (0.08Kg/mtr) |
| 29 | No. 8 GI wire cross lacing (0.131Ke/mtr) |
| 30 | No-6 G I wire (Dia 4.8mm) (0.182kg/mtr) |
| 31 | Eye hook |
| 32 | GI Nut , Bolt & Washer of different sizes |
| 33 | GI pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long |
| 34 | 25x6 mm GI flat for earthing |
| 35 | Part-II : Erection of DSS 11/.4KV -100KVA Pole-mounted -1no. WPB 160x152 (30.44KG/Mtr.),11 mtr |
| 36 | Top Pressure channel (100x50x6) MM M' 2.8Mtr.long , 2Nos. (9.2kg/Mtr) |
| 37 | Transformer mounting channel (100x50x6) MM MS, 2.8Mtr. long , 2 Nos. (9.2kg/Mtr) |
| 38 | HG Fuse and AB Switch mounting channel (75x40x6) MM MS, 2.8Mtr. ling, 4Nos.(6.8Kg/Mtr) |
| 39 | Transformer Belting (50x50x6)MM MS angle,2.8Mtr long, 2Nos.(4.5kg/mtr) with sideangle(total 7.0 Mtr long) |
| 40 | Cuntiliver channel for supporting HG fuse (75x40x6) MM MS, 1.0 Mtr. ling,2Nos.(6.8Kg/Mtr) |
| 41 | Cuntiliver angle for supporting HG fuse (50x50x6) MM MS, 1.5 Mtr. ling, 2Nos.(4.5Kg/Mtr) |
| 42 | Angle for mounting LT Distribution box (35x35x5) MM MS, lMtr long , 2 Nos.(3.5Kg/Mtr) |
| 43 | AB Switch side support channel100x50x6mm, 9.2Kg/Mtr, each chanel length 0.35Mtr, 2nos of chanel required |
| 44 | Channel support for down pipe 75x40x6mm,6.8Kg/mtr, each channel length 0.8Mtr, 1No |
| 45 | Danger Plate |
| 46 | Back Clamp for danger Plate 25X3 mm. flat, length of 0.510mtr |
| 47 | GI barbed wire anticlimbing device |
| 48 | Back Clamp for Barbed wire anticlimbing device 25X3mm. flat,length of 0.510mtr |
| 49 | 11 KV A.B Switch (200A, 3Pole, 50Hz) |
| 50 | 11 KV HG Fuse (200A, 3Pole ) with PI |
| 51 | 11kV,5KN pin insulator polymer |
| 52 | HW fitting(T&C) 45 KN |
| 53 | Disc insulator(B&S)45 KN polymer |
| 54 | PG Clamp for 55mm2 AAA Conductor |
| 55 | Fish Plate 50X6mm., 2.36kg/Mtr., each 280 mtr. Leneth |
| 56 | 25 X 6 mm GI Flat(For others) |
| 57 | 25 x 4 mm GI Flat(For Lightning Arrestor) |
| 58 | 12KV 10KA 11 KV Lighting Arrestor |
| 59 | Earthing Support (Coil Type) |
| 60 | No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2M for connecting pole with coil earthing |
| 61 | H.T. Stay set complete |
| 62 | H.T. Stay Insulator |
| 63 | H.T. Stay CIamp (1.9Kg/pair) |
| 64 | 7/10 SWG G.I. Wire (Grade-2) |
| 65 | 5mm2 AAA Conductor |
| 66 | 3.5 C x 120 MM2 LT PVC cable (Un armoured) |
| 67 | LT distribution box with MCCB, Aluminium Busbar for Two Bay with Kit Kat fuse for 100KVA S/S |
| 68 | 100KVA, 11/0.4KV (AL)Transformer, BIS Energy level-II. |
| 69 | GI pipe Earthing 40 mm dia medium uge(3.25 mm thick ness) 3 mtr long |
| 70 | GI Bolts, Nuts & washers |
| 71 | Black Paint |
| 72 | Yellow Colour Paint for Background |
| 73 | Sundries |
| 74 | Part III : Erection of LT Line With XLPE LT ABC -3x50 +1x35+1x16 mm2 - 1.9KM 8Mtr long PSC Pole |
| 75 | RCC Base plate |
| 76 | 1.1KV LT AB Cable 3x50+3x35+1x16 mm2 |
| 77 | LT stay Set (Complete) |
| 78 | LT Stay Insulator |
| 79 | LT Stay Clamp |
| 80 | 7/12 SWG GI stay wire |
| 81 | Suspension clamp with Eye hook |
| 82 | Dead End Clamp suitable for XLPE Cable |
| 83 | EYE hook for (XLPE Aerial bunched Cable) |
| 84 | Pole clamp for Eye Hook (For AB Cable) |
| 85 | insulated piercing connector type-A main 16-95mm2 & tap 2.5 to 10 sqmm |
| 86 | insulated piercing connector type-B main 16-95 mm2 & tap 2.5 to 10 sqmm |
| 87 | Danger Plate, 1 no |
| 88 | Back Clamp for danger Plat 25X3 mm, flat, 0.59Kg/Mtr. Flat of 0.510mtr 1no |
| 89 | GI barbed wire anticlimbing device 3 Kg. Per support |
| 90 | Back Clamp for anticlimbing device 25X3mm.flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's |
| 91 | Earthing Support (Coil Type) |
| 92 | No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2M’ for connecting pole with coil earthing |
| 93 | G.I. Nuts and Bolts |
| 94 | Black Paint |
| 95 | Yellow Colour Paint for Background |
| 96 | Sunderies |
| 97 | Civil Service Cement concreting for stay anchor plate withC.C. 1:2:4, 0.2 Cum @ 6177.92/- |
| 98 | Concreting of 8/9Mtr Poles in ratio 1:1.5:3=0.375Cum. @6648.85 |
| 99 | Couping of support in ratio C.C. 1:1.5:3, 0.45 Cum @6648.85/- for 11Mtr. Joist Pole/WPB |
| 100 | Couping of support in ratio C.C. 1:1.5:3, 0.1125 Cum |
| 101 | Material for earthing including masonary workfor earth pit, and cement plate cover with salt,charcoal etc. |
| 102 | Boundary Wall for 100KVA 3Mx3M |
| 103 | GIS Services for LT Line |
| 104 | GIS Services for HT Line |
| 105 | GIS Services for DSS |
| 106 | Dismantling Part Dismantle of RSI/WPB Dole 9/11 Mtr. |
| 107 | Dismantling of 9/8m PSC Poles |
| 108 | Dismantling of steel structure |
| 109 | Dismantling of HT line conductor 34-55 sqmm AAAC Conductor |
| 110 | Dismantling of DT 100KVA |
| 111 | Dismantling of LT ABC |
| 112 | Part-l: Erection 11kV OH 3Ph 3W Line with AAAC-55mm2 -0.17KM, with 9Mtr PSC & 10 Mtr PSC Pole @ road Crossing, Cradle Guard -1no. 10 Mtr long 330kg PSC pole |
| 113 | 9Mtr long 330kg PSC pole (Stud) |
| 114 | Base Plate for PSC Pole |
| 115 | Straight Cross Arm Channel 100X50X6mm, 9'2 KG/Mtr., each channel length 1.2 mtr. |
| 116 | Straight Cross Arm Top Channel 100X50X6mm,9.2 KG/mtr, each channel length 0.306 Mtr. |
| 117 | Fish Plate 50X8 mm., 3.14kg/Mtr., each 0.280 mtr. Leneth |
| 118 | Danger Plate, 1 no |
| 119 | Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1 no |
| 120 | GI barbed wire anticlimbing device 3 Kg. Persupport |
| 121 | Back Clamp for anticlimbing device 25X3mm. flat, 0.59Kg/Mtr. Flat of 0.510 mtr length 4 no's |
| 122 | 11kV,skN pin insulator polymer |
| 123 | 11kV V cross Arm (GI) |
| 124 | GI Back Clamp for 11kV ’V’ Cros Arm |
| 125 | Top bracket 100X50X5mm GI channel |
| 126 | HW fitting(T&C) 45 KN |
| 127 | Disc Insulator(B&S)45 KN polymer |
| 128 | Earthing of Support ( Coil Type ) |
| 129 | No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr‘ For connecting pole with Coil earthing |
| 130 | PG Clamp for 55 mm2 AAAC conductor |
| 131 | GI Nut , Bolt & Washer of different sizes |
| 132 | H.T. Stay clamp |
| 133 | H.T. Stay set (Complete ) |
| 134 | H.T. Stay Insulator |
| 135 | 7/10 SWG Stay Wire |
| 136 | AAA conductor,55 mm2 |
| 137 | Black Paint |
| 138 | Yellow Colour Paint for Background |
| 139 | Guarding @ Road Crossing -01 No.s Guarding cross arm of 75X40X6mm GI Channel 2.2 ntr long 4Nos @7.14Kg/mtr |
| 140 | No. 10 GI wire cross lacing (0.08Kg/mtr) |
| 141 | No. 8 GI wire cross lacing (0.131Kg/mtr) |
| 142 | No-6 G I wire (Dia 4.8mm) (0.182ke/mtr) |
| 143 | Eye hook |
| 144 | GI Nut , Bolt & Washer of different sizes |
| 145 | G.I. pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long |
| 146 | 25x6 mm GI flat for earthing |
| 147 | Sunderies |
| 148 | Part II : Erection of LT Line With XLPE LT ABC -1.3KM 8Mtr long PSC Pole |
| 149 | 9Mtr long PSC Pole |
| 150 | RCC Base plate |
| 151 | 1.1KV LT AB Cable 3x50+1x35+1x16 mm2 |
| 152 | LT Stay Set (Complete) |
| 153 | LT Stay Insulator |
| 154 | LT Stay Clamp |
| 155 | 7/12 SWG GI stay wire |
| 156 | Suspension clamp with Eye hook |
| 157 | Dead End Clamp suitable for XLPE Cable |
| 158 | EYE hook for (XLPE Aerial bunched Cable) |
| 159 | Pole clamp for Eye Hook (For AB Cable) |
| 160 | insulated piercing connector type-A main 16-95 mm2 & tap 2.5 to 10 sqmm |
| 161 | insulated piercing connector type-B main 16-95mm2 & tap 2.5 to 10 sqmm |
| 162 | Danger Plate, 1 no |
| 163 | Back Clamp for danger Plate 25X3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr 1no |
| 164 | GI barbed wire anticlimbing device 3 Kg. Per support |
| 165 | Back Clamp for anticlimbing device 25X3mm.flat, 0.59 |
| 166 | Earthing Suppon (Coil Type) |
| 167 | No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing |
| 168 | G.l. Nuts and Bolts |
| 169 | Black Paint |
| 170 | Yellow Colour Paint for Background |
| 171 | Sunderies |
| 172 | Civil Service Cement concreting for stay anchor plate withC.C. 1:2:4, 0.2 Cum @ 6177.92/- |
| 173 | Concreting of 8/9Mtr Poles in ratio 1:1.5:3=0.375Cum. @6648.85 |
| 174 | Concreting of 10Mtr Poles in ratio 1:1.5:3=0.415Cum. @6648.85 |
| 175 | Concreting of support C.C. 1:1.5:3, 0.45 Cum. @6648.85/- for 11 Mtr. Joist Pole/WPB |
| 176 | Material for earthing including masonary work tor earth pit, and cement plate cover with salt, charcoal etc. |
| 177 | GIS Services LT |
| 178 | GIS Services HT |
| 179 | Dismantling Part Dismantling of 9/8m PSC Poles |
| 180 | Dismantling of HT line conductor 34-55 sqmm Conductor |
| 181 | Dismantling of LT ABC Please Enable Macros to View BoQ information |