|
| 1 | Lifting of cover from manhole / Gully trap and taking out waste soil, sludge and other foreign materials from gully trap / manhole etc, volume not exc 1.5 cum each, removal of sludges in water sealed container to a distance not exc 50 m and washing manhole / gully trap with adequate quantity of water and refixing the cover in the same location complete all as specified and directed. |
| 2 | Cleaning by rodding/ bamboo split and taking out waste soil sludge and other foreign materials from sewage line any dia removed in sealed container (from WC to onward upto septic tank/soak well) and flushing with water etc complete all as specified and directed. |
| 3 | M&L for pumping out sludge water from manhole of any section for cleaning blocked sewage line, depth of manhole exc 1.20 mtr but not exc 1.80 mtr complete all as specified and directed. |
| 4 | Cleaning of existing open or covered drain of any section and depth by removing mud, sludge or foreign materials from existing storm water drain/covered drain, static tanks etc, flushing with adequate quantity of water and removing the sludge to a distance not exc 50 m complete all as specified and directed. |
| 5 | Cleaning of blocked WC by using vaccum pump including opening and refixing/CI cover to bend and branch pieces and finally cleaned with adequate quantity of water complete all as specified and directed. |
| 6 | Demolition and breaking up drain pipes of 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and taking out of trenches if required complete all as specified. |
| 7 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan area in hard / dense soil and getting out complete all as specified and directed. |
| 8 | Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed. |
| 9 | Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed. |
| 10 | Supply, laying and jointing 150 mm nominal bore dia DWC(HDPE double wall corrugated), socketed and sewage pipes having 6.0 M length, conforming to IS 16098 (Part-2) of SN-4 Stiffiness with and including necessary jointing matrials etc complete all as specified and directed. |
| 11 | Demolition reinforced cement concrete in slab, beams, staircase, landings, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 12 | S&F SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal dia conforming to IS 12592, total weight of cover and frame to be not less than 182 Kg, fixed in PCC 1:2:4 Type B1 (Using 20 mm graded stone aggregate) work for cover slab of drain / manhole complete all as specified and directed. |
| 13 | S& F pultruted FRP gratings for drain civer with mesh size 38mmx 38 mm of weather resistance corrosion resissance omplete all as specified and directed. |
| 14 | Complete removing the plants from the surfaces of the building with complete roots, applying recommended chemical to prevent further growth as directed, making good the disturbed surface with cement mortar 1:3 and applying the same surface finish of the existing surface and finished to match with the surrounding surfaces including removal of debris etc., out side the premises complete all as required complete all as specified and as directed. |
| 15 | Cleaning of CI/PVC SWR pipe of any dia by rodding or with bamboo split including removing and refixing inspection eye door cover in existing position etc complete all as specified and directed. |
| 16 | Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed |
| 17 | S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 18 | Fixing only 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.(Note: Pipe retrive from taking down of rain water pipe here-in-before shall be re-used.) |
| 19 | S & F 75 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 20 | S & F in repair 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 21 | S & F in repair 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 22 | S & F in repair 110 mm bore, PVC (SWR) vent cowl of any radius complete all as specified and directed. |
| 23 | Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity exc 250 Ltrs but not exc 500 Ltrs, and from mouths of circulating pipes, etc complete all as specified and directed. |
| 24 | Cleaning and removing all scale and dirt, etc, from PVC/RCC tanks of capacity exc 500 Ltrs but not exc 1000 Ltrs, and from mouths of circulating pipes, etc complete all as specified and directed. |
| 25 | S & F 500 litres capacity rotational moulded polyethylene water storage tanks , double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. |
| 26 | S & F 1000 litres capacity rotational moulded polyethylene water storage tanks , double layer construction, ISI marked (Cylindrical vertical with closed top), hoisted and fixed in position including taking down old unserviceable one as specified in SSR Part I and directed. |
| 27 | S&F in repairs 25 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 28 | S&F in repairs 20 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 29 | S&F in repairs 15 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 30 | S&F in repairs gun-metal, globe or gate valves of 25mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 31 | S&F in repairs gun-metal, globe or gate valves of 20mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 32 | S&F in repairs gun-metal, globe or gate valves of 15mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 33 | S & F in repair fancy type Bib taps with wall flange, cromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete complete all as specified and directed. Make: Jaquar Cat Part No. FUS-29037 or Equivalent make as per list of Makes in PS. |
| 34 | S & F in repair fancy type Two way Bib taps with wall flange, cromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.Make: Jaquar Cat Part No. FUS-29041 or Equivalent make as per list of Makes in PS. |
| 35 | S & F in repair Wall Mixer 3-in-1 System with Provision for both Hand Shower and Overhead Shower Complete with 115mm Long Bend Pipe, Connecting Legs & Wall Flange complete all as specified and directed. Make: Jaquar Cat Part No. FUS-29281or Equivalent make as per list of Makes in PS. |
| 36 | S & F in repair CP Sink Cock with Provision for Connection to RO from rear side & Swinging Spout complete all as specified and directed. Make: Jaquar Cat Part No. FLR5355N or Equivalent make as per list of Makes in PS. |
| 37 | S & F in repair CP Basin Mixter Single Lever Tall Boy with 150mm Extension Body Fixed Spout without Popup Waste System with 600mm Long Braided Hoses Make: Jaquar Cat Part No. FUS-29005NB or Equivalent make as per list of Makes in PS. |
| 38 | S&F in repair Overhead Shower 180mm dia Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System complete all as specified & directed.Make: Jaquar Cat Part No. OHS-1755 or Equivalent make as per list of Makes in PS. |
| 39 | S&F in repair Hand Shower 105mm dia Round Shape Single Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System complete all as specified & directed.Make: Jaquar Cat Part No. OHS-1709 or Equivalent make as per list of Makes in PS. |
| 40 | S&F in repair of CP fancy type angular stop cock 15mm dia with wall flange complete all as specified & directed.Make: Jaquar Cat Part No.FLR-5053N or Equivalent make as per list of Makes in PS. |
| 41 | S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 42 | S & F in repair Single Towel Rail 600mm Long, Stainless Stee complete all as specified & directed. (Make: Jaquar Cat Part No. ACN 1111SM or Equivalent make as per list of Makes in PS.) |
| 43 | S & F in repair Toilet paper Roll Holder with Stainless Steel Flap complete all as specified & directed. (Make: Jaquar Cat Part No. ACN-1153S or Equivalent make as per list of Makes in PS.) |
| 44 | S & F in repair towel rack with lower hanger (stainless steel) with hook complete all as specified & directed. (Make: Jaquar Cat Part No. AHS-1581H or Equivalent make as per list of Makes in PS.) |
| 45 | S & F in repair Health Faucet spray with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook complete all as specified & directed Make: Jaquar Cat Part No.ALD-565 or Equivalent make as per list of Makes in PS. |
| 46 | S&F in repair, Sheet Glass Shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 47 | S&F in repair, 600 mm x 450 mm bevelled edge looking mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated brass screws & cup washers complete all as specified and directed. |
| 48 | S&F in repair 32 mm dia flexible PVC waste pipe for basin, sink & urinal etc complete all as specified and directed. |
| 49 | S&F in repair vitreous China wash hand basin, white, flat back, size 630 x 450 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed. |
| 50 | S&F in repair, 15 mm dia of bore, fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe & fixed complete all as specified and directed. |
| 51 | S&F Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/ off white, closed pattern incl all necessary accessories like rag bolts/ gel gasket, 'S' trap, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified. |
| 52 | S&F in repairs plastic water closet seat cover of any description colour match to existing closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinge device (Indian / Anglo indian) complete all as specified and as directed. |
| 53 | S & F in repairs, 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 54 | S&F in repairs sinks with drainage board made of stainless steel l mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 55 | Taking down steel tubing and connections incl cleaning for refixing or removal form site for 15mm bore pipe complete all as specified and directed. |
| 56 | Taking down steel tubing and connections incl cleaning for refixing or removal form site for 20mm bore pipe complete all as specified and directed. |
| 57 | S&F 20 mm CPVC pipes SDR 11 shall be fixed with requisite special type of fittings on walls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed.(Note: Necessary special fittings shall be measured and paid under relevant supply only items.) |
| 58 | S&F 25 mm CPVC pipes SDR 11 shall be fixed with requisite special type of fittings on walls(conceled) & ceiling or laid in floors for internal water supply complete all as specified and directed.(Note: Necessary special fittings shall be measured and paid under relevant supply only items.) |
| 59 | Supply only 20mm brass elbow for jointing CPVC pipe all as specified and directed. |
| 60 | Supply only 20mm brass elbow (3/4 X ½) for jointing CPVC pipe all as specified and directed. |
| 61 | Supply only 20mm brass Tee for jointing CPVC pipe all as specified and directed. |
| 62 | Supply only 20mm male brass threaded adaptor (MTA/ MBTA) for jointing CPVC pipe all as specified and directed. |
| 63 | Supply only 20mm female brass threaded adaptor (FTA/ FBTA) for jointing CPVC pipe all as specified and directed. |
| 64 | Supply only 20mm Union for jointing CPVC pipe all as specified and directed. |
| 65 | Supply only CPVC reducer 15 mm to 25 mm for CPVC pipe all as specified and directed. |
| 66 | Supply only 25mm brass elbow for jointing CPVC pipe all as specified and directed. |
| 67 | Supply only 25mm brass Tee for jointing CPVC pipe all as specified and directed. |
| 68 | Supply only 25mm male brass threaded adaptor (MTA/ MBTA) for jointing CPVC pipe all as specified and directed. |
| 69 | Supply only 25mm female brass threaded adaptor (FTA/ FBTA) for jointing CPVC pipe all as specified and directed. |
| 70 | Supply only 25mm Union for jointing CPVC pipe all as specified and directed. |
| 71 | Supply only 25mm tank adopter for jointing CPVC pipe all as specified and directed. |
| 72 | Dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing), removal servicable tiles to store and rubbish off the premises complete all as specified and directed. |
| 73 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 74 | Material and labour for Glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 75 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish off the premises complete all as specified and directed. |
| 76 | M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 77 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 78 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 79 | Demolition of cement concrete (un-reinforced) of any description in ground floors and paving's not exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 80 | M&L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed. |
| 81 | Claning of septic tank/soak pit 50 to100 users capacity and filter bed of any depth by removing of sludge, silt, sand or material of any description by dewatering of septic tanks and filter beds including blocking/diversion of inlet line by means of mechanical process for the period and removing the material obtained to outside MD land including cleaning of surface completely with water complete in foul position (Solid material will be measured and dewatering is included in rate) complete all as specified and directed. Please Enable Macros to View BoQ information |