| 1 | Dismantling and taking down carefully defective/non fuctional light fittings from its existing position and refixing the same after repairing/replacement with new of unserviceable spare parts including re-assembling and testing complete all as specified and directed.(Note : Spare parts/component of street light fitting shall be measured and paid separately under respective items as \\"Supply only\\") |
| 2 | Supply only LED light driver suitable for LED Street light fitting as per sample of capacity 45/ 50/60 Watt complete all as specified and directed. |
| 3 | Supply only LED light driver suitable for LED Flood light fitting as per sample of capacity 100/120 watt complete all as specified and directed. |
| 4 | Supply only LED light driver suitable for post top lantern/bollard LED light as per sample of capacity 10/20 watt complete all as specified and directed. |
| 5 | Supply and fixing in replacement of old unserviceable Street light fitting with new generation energy saving & environmental friendly long life LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum housing with toughened glass and heat resistant and indvidual high power LED's ,high efficiency >120 lm/W complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 66 protection including making electric connection with three core copper cable with all accessories complete all as specified and directed. Note-street light will be fitted on pole of 8 to 10 mtr height approx |
| 6 | Same as above item no. 5 but capacity 90 watt |
| 7 | Supply and fixing in replacement of old unserviceable flood light fitting with new generation energy saving & environmental friendly long life LED flood light 30 watt 230 V AC outdoor type with high pressure die cast aluminum housing with toughened glass and heat resistant and indvidual high power LED's with thermal management in multiple optics,high efficiency >120 lm/W and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including making electric connection with three core copper cable with all accessories complete all as specified and directed.Note-flood light will be fitted on wall/ pole as per site requirement |
| 8 | Same as above item no. 7 but capacity 50 watt |
| 9 | Same as above item no. 7 but capacity 100 watt |
| 10 | Same as above item no. 7 but capacity 150 watt |
| 11 | Supply and fixing in replacement of old unserviceable post top lantern with new decorative LED post top lantern 20 watt 230 V AC outdoor type whether proof with powder coated die cast aluminum alloy housing suitable for 40 to 50 mm mounting pipe high efficiency >120 lm/W and equipped with IP66 protection, with driver and lamp including making electric connection with three core copper cable with all accessories complete all as specified and directed. |
| 12 | Supply and fixing in replacement of old unserviceable bollard light with new LED Bollard 10/12 watt,environmental friendly ,new generation,energy saving ,long life,high efficiency aesthetically designed aluminium landscape IP 66 luminarie for diffused lighting with high power LED as light source with driver and lamp including making electric connection with three core copper cable with all accessories complete all as specified and directed. |
| 13 | Supply and fixing in repair old rusted street light bracket, clamps, nuts and bolt with new bracket for street light fittings made out of 32 mm dia \\"medium grade\\" galvanized steel (GI) tubing of 1.5 m long, bent to required shape (having an angle 120 degree) including necessary FI clamp (02 Nos of size 40 x 5 mm) nuts, bolts and washers and fixing to the pole complete after taking down old unserviceable bracket from the pole complete all as specified and directed. |
| 14 | S & F in repair service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tap and over all PVC sheathed of size 6 Sqmm 2 core complete all as specified and directed. |
| 15 | S & F in repair service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tap and over all PVC sheathed of size 4 Sqmm 2 core complete all as specified and directed. |
| 16 | S&F LT cable junction box dust and whether proof made out of PVC non metallic sheet FRP type, factory made out of PVC non metalic sheet FRP type, size of box 250mm x 200 mm x 100 mm deep with swivelling cover and locking clamp, MS clamps and nuts, bolts, for fixing the box on steel tubular pole, consisting of aluminium bus bar strip 150mm x 30 mm x 3 mm - 04 Nos mounted on pole and provision of incoming and outgoing PVC insulated cable with grommets including inbuilt 6 Amp MCB SP 10 KA-01 Nos complete all as specified and directed. Make : Sintex /Havells/ Hensel. |
| 17 | Taking out unserviceable LT cable of any size from trenches/duct etc carefully including bricks and keeping in safe custody either for relaying or disposal complete all as specified & directed |
| 18 | Supply and Laying in trenches / fixed to wall/ drawn in pipe/duct/laid in floor XLPE insulated screened,PVC bedded and sheathed and steel wire/strip armoured cable 1100V grade with stranded aluminum conductor of cross sectional area 16 Sqmm 4 core complete all as specified and directed. |
| 19 | Same as above item no 18 but size 10 sqmm 2 core |
| 20 | Excavation in trenches not exc 1.5 m in depth and not exc 1.5 mtr wide including getting out in soft/loose soil complete all as specified and as directed. |
| 21 | Returning filling in including leveling spreading watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed . |
| 22 | Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed. |
| 23 | M&L for spreading clean dry sand in cable trenches for cushioning of cable protection complete all as directed. Note :- Sand will be measured after punning. |
| 24 | Material & labour for bricks sub-class`B' (Old size), laid flat in trenches for cable protection all as specified and directed. |
| 25 | M & L for boring of holes under road, pavement, hard standing by trenchless boring manually or by machine for insertion of GI pipe of size upto 40 mm dia suitable complete all as specified and directed. |
| 26 | S&F GI pipe 40 mm light grade with all fitting fixed to electric pole and laid in road crossing/along the pole for cable protection with suitable size clamp, nut bolt and washers all as directed. Make : Tata/Jindal/swastik |
| 27 | M&L for painting of existing LT/HT pole upto 9 / 11 meter height with two coat of aluminium paint complete including preparation of old painted surfaces and including making blue / black colour paint strip of 15 cm width including writing the Pole Nos. complete all as specified and directed. |
| 28 | Supply and fixing in repair MCB single pole 6 to 32 Amps, 240 Volts 50 HZ, 10 KA breaking capacity, 'C' curve complete all as directed. |
| 29 | Supply and fixing in repair Power contactor with new power contactor 3 pole AC, with 415 volt coil, 70 Amp rating complete all as specified and directed. |
| 30 | Supply and fixing in repair analog time switch with new analog time switch in time span 15 minutes ,in street light circuit to control the ON/OFF timing of street/parameter light complete all as specified and directed by the Engineer-in-Charge. |
| 31 | Supply and fixing in repair aviation light fitting with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure capacity 20 Watt complete all as specified and directed by Engineer-in-charge. |
| 32 | Dismantling and taking out street light steel tubular poles of any size embedded in concrete upto bottom of foundation with the help of crane,hydra or suitable T&P and transporting/ Stacking for re-use and refixing steel pole to new location within Manauri AF campus incl all necessary excavation & earth work in any type of soil for foundation of poles, PCC in foundations below GL and in plinth block(coping) above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, including necessary form work and providing 3 Nos of 30cm wide circular bands with Aluminium & blue paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed . inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.Note- Rate is inclusive of Necessary excavation and PCC work. |
| 33 | M & L for plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) for foundation of poles, Stay assembly, struts, etc. including all necessary formwork complete all as specified & as directed. |
| 34 | S&F in repair MCCB 125 Amp 4 Pole and 25KA rupturing capacity with adjustable thermal magnetic release type complete all as specified and directed. |
| 35 | S&F in repair MCCB 100 Amp 4 Pole and 16KA rupturing capacity with adjustable thermal magnetic release type complete all as specified and directed. |
| 36 | S&F in repair MCCB 63 Amp 4 Pole and 16KA rupturing capacity with adjustable thermal magnetic release type complete all as specified and directed. |
| 37 | S&F in repair MCB TPN 40 to 100 Amp 415 Volt ,'C' curve type and 10KA rupturing capacity all as specified and directed. |
| 38 | M& L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cmx6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part-I including and connecting to earthing test point block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and testing on completion with and including 15 mm bore light grade G.I. protection pipe (upto 7.5 M beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 Nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 40 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work including Earthing pit marker/ identifier of Iron plate of size 300mm X 200mm X 3mm and alongwith 1 meter long medium grade GI pipe of size 15 mm dia weilded with steel plate including painting with applying one coat of red oxide and two coat of painting with synthetic enameled paint of approved quality including writing letters as specified ny EIC complete |
| 39 | Supply and installation in repair of maintenance free battery lead acid type of capacity 12 Volt 150 AH suitable for solar light panel installed at various locations Complete all as specified & approved by Engineer-in-charge. |
| 40 | Supply and fixing in replacement Energy saving tri colour(orange-white-green) LED flood light fitting 150 watt with powder coated PDC aluminium body with toughened glass , equipped with secondary optical PC lenses efficiency >120Lm/w, 5700K CCT, IP 66 protection, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 41 | Supply and fixing in replacement Energy saving tri colour(orange-white-green) LED flood light fitting 150 watt with powder coated PDC aluminium body with toughened glass , equipped with secondary optical PC lenses efficiency >120Lm/w, 5700K CCT, IP 66 protection, input voltage from 120-270 V power factor above 0.95 complete fitting including all accessories complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |