| 1 | Demolition of brickwork built in cement mortar or cement lime mortar complete all as specified and directed. |
| 2 | M&L brick work with sub class 'B' bricks, straight or curved on plan exc. 6 mtr mean radius built in CM(1:6) complete all as specified and directed. |
| 3 | Taking down cement plaster on brick/stone surface of wall/RCC wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 4 | M & L rendering 15mm thick cement plaster 1:4 on fair faces of brick work or concrete surface and finishing even and fair complete all as specified and directed. |
| 5 | M & L for preparation of new surface and applying two coat of cement base paint over a coat of primer all as specified and directed |
| 6 | M & L for preparation of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50gm/ltr and UV resistance as per IS 15489:2004, alkali & fungal reistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon aditives at 1.43 ltr/10sqm over and including priming coat of exterior primer applied at 0.90ltr/10sqm all as specified and directed by Engineer-in-Charge. |
| 7 | Demolition of cement concrete reinforced in ground floors and pavings n exc 15cm thickness in any psition etc complete all as specified and directed by Eng-in-Charge.. |
| 8 | M&L for RCC 1:2:4 nominal mix beams, cantilevers, bressummers, lintels over 1.5m span and like all as specified and directed by Engineer-in-Charge. |
| 9 | Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, ressummers, lintels, cantilevers, shelves, lintel band, chhajja including sup- ports, overhangs,etc. also splays between floors and beams, etc. complete all as specified and directed. |
| 10 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion of concrete above GL or below GL complete all as specified and directed. |
| 11 | Dismantling chain link fencing any type complete all as specified and directed. |
| 12 | Supply & Fixing 3'' x 3'' (75mmx75mm) mesh size & 3.4 mm dia of wire chain link MS galvanised fencing complete including line wires, rails, straining bolts etc, including provision of binding wire complete all as specified and directed. |
| 13 | S&F Rolled Mild Steel Framed work as in doors or Gates, grills, fencing post, support on wall of angle or other section confirming to Fe 410 -W (Gde-, E- 250) A quality-with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and directed. |
| 14 | Dismantling/Removing of existing barbed wire/razor wire of any discreption/pattern complete all as specified and directed. Note: Each line of wire will be measured. |
| 15 | S&F galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised complete all as specified and directed. |
| 16 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed by Eng-in-Charge. |
| 17 | M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded stone aggregate as in sub base to floor etc complete all as specified and directed by Engr-in-charge. |
| 18 | M & L for 40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor Finishing surfaces of concrete topping even and fair complete all as specified and directed by Engineer-in-Charge. |
| 19 | M & L for PCC 1:2:4 type B-1, using 20 mm graded stone agg as in foundation, complete all as specified and directed. |
| 20 | M&L for PCC1:2:4 type B-0 using 12.5mm graded stone aggregate as in copping,plinth course,bed plates and the like including necessary use and waste of formwork complete all as specified and directed by Engr-in-charge. |
| 21 | M&L providing Chequered cement concrete tiles 25cm x 25cm x 20-22mm thick, set, jointed and pointed in neat cement mortar 1:3 in floors with grey cement and pigment laid over and including screed bed or bedding layer 20 mm thick in cm 1:6 as in floors complete all as specified and directed. |
| 22 | M & L for exterior grade heavy duty full body outer designer parking tiles 400 x 400 x 10 mm, in floors etc. of colour and design as approved by Engr-in-Charge, set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 20 mm thick screed bed with CM (1:6) complete all as specified and directed. |
| 23 | Dismantling of paver blocks of any desciption and any thickness in floors, laid dry complete all as specifed and directed. |
| 24 | M&L for rubber moulded precast concrete interlocking paver block any shape and size,with gray cement and pigment glossy finish confirming to IS 15658-2006 of 80 mm thickness M-40 Grade complete all as specified and directed. |
| 25 | M & L for rubber moulded precast concrete interlocking paver block any shape and size with gray cement and pigment glossy finishconfirming to IS 15658-2006 of 60 mm thickness M-40 Grade complete all as specified and directed. |
| 26 | M&L for sand filling under floors as in cusioning and like including watering and consolidation complete all as specified and directed. |
| 27 | M&L in applying two coats of synthetic enamel paints over a coat of red oxide primer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed. |
| 28 | M&L 75mm thick PCC (1:2;4) type B-1 using 20mm graded coarse aggt in plinth protection laid in alternate bays and joint filled with bituminious mastic and like including neccesry form workcomplete all as specified and directed. |
| 29 | M&L for preparation of old surfaces and applying one coat of synthetic enamel paint on surfaces over 10 cm width or girth complete all as specified and directed.Note : The painting is to be done on steel sections fixed on boundary wall/gates/doors and similar places. |
| 30 | Excavation in trenches not exc 1.5mtr wide and n.exc. 1.50m deep as in foundation of drain n.exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.. |
| 31 | Returning, filling in, including spreading, levelling, watering and well ramming in layers,soil not exc 25 cm complete as specified and directed. |
| 32 | M&L for PCC1:3:6 type C-2 using 40mm graded stone aggregate,as in surface channels and drains filling & mass concrete etc complete all as specified and directed. |
| 33 | M&L brick work with sub class 'B' bricks(old size bricks) straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1 : 4 and external face of brick work pointed flush in the same mortar as the work proceeds, complete as specified and directed. |
| 34 | M & L rendering 15mm thick cement plaster 1:4 on fair faces of brickwork or concrete surface and finishing even and smooth without using extra cement all as specified and directed. |
| 35 | M&L PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, acing courses, parapets and railings upto 60 cm in height, copings,benching, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating,complete as specified and directed. |
| 36 | M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified & as directed. |
| 37 | Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc.complete all as specified & as directed. |
| 38 | S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed. |
| 39 | Providing precast cement concrete type B-1 (1:2:4) using 20 mm grade aggregate set in 1:4 cement mortar in but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, complete all as specified & as directed. |
| 40 | M&L 12 mm dia TMT bar, cut to length, bent to shape required for rcc pre cast cover slab, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified & as directed. |
| 41 | M&L for old size brick laid flat in floors, bedded, jointed in CM 1:6 and pointed with CM 1:3 complete as specified and directed. |
| 42 | Ditto but laid on edge complete as specified and directed. |
| 43 | S & F in repairs 110 mm PVC (SWR) Pipes single socketed in any length with rubber ring joints fixed to wall and floors complete as specified and directed. |
| 44 | S&F 110mm PVC (SWR) bends any radius complete as specified and directed. |
| 45 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri Please Enable Macros to View BoQ information |