| 1 | Excavation in trenches n.exc 1.5 M wide and n. exc 1.5 M depth and getting out in hard/dense soil for removing / taking out burnt cables complete all specified and as directed. |
| 2 | Returning, filling in include spreading levelling, watering and well ramming in layers n.exc.25cm thick complete all specified and as directed. |
| 3 | Removing excavated material to a distance n.exc 50 M and depositing where directed at a level n.exc 1.5 M above the starting point complete all specified and as directed. |
| 4 | Spreading and compacting of riddled earth obtained from trenches for cable ducts / trenches for cable cushion on both top and bottom of cable, including ramming as specified and directed by Engineer-in-Charge.(Note :- Punned thickness only will be measured) |
| 5 | Supply and laying burnt bricks of old size sub-class B for cable protection complete all as directed & as specified. |
| 6 | Testing and taking out old unserviceable Moulded Case Circuit Breakers in the existing feeder pillar box with and replacement with new MCCB including connecting the incoming and out going cables by using suitable cable glands and jumpers/cable with the bus bar of following capacity complete as specified and directed by Engr-in-Charge. |
| 7 | (a) MCCB 4 pole 800 Amps 50 KA. Make L&T Cat No-CM96111OOOOX1 |
| 8 | (b) MCCB 4 pole 630 Amps 50 KA Make L&T Cat No-CM93008OOOOX1 |
| 9 | (c) MCCB 4 pole 250 Amps 36 KA. Make L&T Cat No-CM93003OOOOX1 |
| 10 | (d) MCCB 4 pole 200 Amps 36 KA. Make L&T Cat No-CM93003OOOOX1 |
| 11 | (e) MCCB 4 pole 160 Amps 25 KA Make L&T Cat No-CM90642OOMO |
| 12 | (f) MCCB 4 pole 125 Amps 25 KA Make L&T Cat No-CM90642OOMO |
| 13 | (g) MCCB 4 pole 100 Amps 25 KA Make L&T Cat No-CM91712OOKOOG |
| 14 | Testing and taking out old unserviceable Miniature Circuit Breakers in the existing feeder pillar box and replacement with new MCB including connecting the incoming and out going cables by using suitable cable lugs and connector with the bus bar of following capacity complete as specified and directed by Engr-in-Charge. |
| 15 | (a) MCB 4P, 32 Amp, 10 KA, 'C' Series Make L&T Cat No-BB40320C |
| 16 | (b) MCB 4P, 63 Amp, 10 KA, 'C' Series Make L&T Cat No-BB40630C |
| 17 | (c) MCB TP, 32 Amp, 10 KA, 'C' Series Make L&T Cat No-BB30320C |
| 18 | (d) MCB 4P, 80 Amp, 15 KA, 'C' Series Make L&T Cat No-AU15S40803C |
| 19 | (e) MCB 4P, 40 Amp, 10 KA, 'C' Series Make L&T Cat No-BB40400C |
| 20 | (f) MCB DP, 40 Amp, 10 KA, 'C' Series Make L&T Cat No-BB20400C |
| 21 | (g) MCB DP, 32 Amp, 10 KA, 'C' Series Make L&T Cat No-BB20320C |
| 22 | (h) MCB 4P, 16 Amp, 10 KA, 'C' Series Make L&T Cat No-BB40160C |
| 23 | (j) MCB SP, 6-32 Amp, 10 KA, 'C' Series Make L&T or equivalent |
| 24 | Material & Labour for opening the cover of LT Panel, checking for tightness of all connections/ joints, cleaning dust and dirt from busbar, checking for ACB 4000/3200/1600/800 A, 440V, 4P, dismantling, servicing of fixed and moving contacts, repair and replacement of fixed copper terminal/contacts (male and female ), insulation tubes including other connected items to functional of ACB including panel board , lamp indicators , cleaning the fixed and moving contact inside the ACBs properly , checking of EDO/MDO mechanism, servicing and greasing all movable mechanism , replacement of defective fuses , wiring, shunt coil, trip coil etc and reassembling and testing and serviceability check complete all as specified and directed by Engineer-in-Charge and manufacturer instructions. |
| 25 | Non comprehensive maintenance and submitting health check report by OEM for 30 KVA UPS system along with battery bank and checking battery terminal for tightness or replacement, connection cable including other connected items to functional of UPS , lamp indicators ,meters, lubricating battery terminal, replacement of defective fuses , wiring, IGBT card, Control Card, rectifier unit with air exhaust system, capacitor and reassembling,testing and serviceability check,replacement of unserviceable spares complete all as per the direction of Engineer in Charge and manufacturer instructions. Note: Spares used for repair and replacement will be measured and paid separately. |
| 26 | Supply only online UPS Control card of 30 KVA UPS of approved make required as per site complete all as directed & as specified by Engr-in-Charge |
| 27 | Supply only online UPS IGBT card of 30 KVA UPS of approved make required as per site complete all as directed & as specified by Engr-in-Charge |
| 28 | Supply only online UPS Charger card of 30 KVA UPS of approved make required as per site all as directed & as specified by Engr-in-Charge |
| 29 | Supply only online UPS Power supply card of 30 KVA UPS of approved make required as per site all as directed & as specified by Engr-in-Charge |
| 30 | Checking and servicing of PLC panel for fault and rectification by providing skilled technician, and testing after rectification complete all as specified and directed. |
| 31 | Material & Labour for laying and levelling stone aggregate loose filling using 40 mm graded stone aggregate around the transformer yards after removing the existing debris and stacking the existing aggregate complete all as specified and directed. |
| 32 | Material & Labour for taking out LT UG cable any type and checking for fault, rectifying and relaying after repair with help of required tools and plant as required all as specified and directed.Note:(i) Excavation, returning filling shall be measured and paid separately.(ii) Necessary tools and plants shall be arranged by the contractor and no extra payment shall be paid. |
| 33 | Taking down burnt/ damaged LT cable of any size complete all as directed. |
| 34 | Material & Labour for laying LT UG cable, 1100 volts grade, XLPE insulated and sheathed, armoured, multistranded, heavy duty electric cable with aluminium conductor laid in trenches, ducts, on poles, walls, through pipes etc including identification tags over on cable complete for the following sizes including cable glands on both side terminations where necessary complete all as specified and directed by Engr-in-Charge. |
| 35 | (a) 4 core 10 Sqmm |
| 36 | (b) 4 core 25 Sqmm |
| 37 | Material & Labour for repair to LT panel door with repair/ replacement of hinges, welding, replacement of defective packing/ rubber beading of panel including fabrication of any type and making good the disturbed surfaces at site with powder coating paint complete all as specified and directed by Engr-in-charge. |
| 38 | Supply and Fixing ACB Bezel for 4000 Amp L & T for model CN-CS 4000 HO make of suitable size including taking down old existing complete all as specified and directed by Engr-in-Charge. |
| 39 | Supply and Fixing ACB Bezel for 1600 Amp L & T for model CN-CS 1600 S1 make of suitable size including taking down old existing complete all as specified and directed by Engr-in-Charge. |
| 40 | Supply and Fixing ACB Bezel for 800 Amp L & T for model CN-CS 800 S1 make including taking down old existing of suitable size as specified and directed by Engr-in-Charge. |
| 41 | Supply and Fixing in repair interlocking key assembly as specified in ACB of existing make and grade/model all as specified and directed. |
| 42 | Supply and Fixing in repair 230V Control and Power on indication lamp complete of existing make all as specified and directed. |
| 43 | Supply and Fixing in repair TP 9 Amp contactor, 230 Volts complete of existing make all as specified and directed. |
| 44 | Supply and Fixing in repair 4 C/O Relay, 24 V complete of existing make all as specified and directed. |
| 45 | Supply and Fixing in repair 8 channel relay module, 24 V complete of existing make all as specified and directed. |
| 46 | Supply and Fixing in repair 4 channel relay module, 24 V complete of existing make all as specified and directed. |
| 47 | Supply and Fixing in repair DC SMPS 6 Amp, 230/24 Volts complete of existing make all as specified and directed. |
| 48 | Supply and Fixing in repair annunciator 12 window complete of existing make all as specified and directed. |
| 49 | Supply and Fixing in repair Hooter complete of existing make all as specified and directed. |
| 50 | Supply and Fixing in repair selector switch 16 Amp 2 position complete of existing make all as specified and directed. |
| 51 | Supply and Fixing in repair breaker control switch complete of existing make all as specified and directed. |
| 52 | Supply and Fixing in repair emergency stop push button complete all as specified and directed. |
| 53 | Supply and Fixing in repair air exhaler fan mounted on PLC panel of existing make complete all as specified and directed. |
| 54 | Supply and Fixing in repair spring charging motor for ACB of existing make complete all as specified and directed. |
| 55 | Supply and Fixing in repair fixed arcing contact for ACB of existing make complete all as specified and directed. |
| 56 | Supply and Fixing in repair moving arcing contact for ACB of existing make complete all as specified and directed. |
| 57 | Supply and Fixing in repair under voltage release coil, 240 V for ACB of existing make complete all as specified and directed. |
| 58 | Material & Labour for checking of shunt release coil and repair/ replacement of shunt release coil for ACB as per sample, 'complete all as specified and directed by Engr-in-Charge. |
| 59 | Supply and Fixing in repair including taking down closing coil, 24 V for ACB of existing make complete all as specified and directed. |
| 60 | Supply and Fixing in repair side plate assembly with EDO kit for ACB of existing make complete all as specified and directed. |
| 61 | Supply and Fixing in repair motor limit switch for ACB of existing make complete all as specified and directed. |
| 62 | Supply and Fixing in repair jaw contact male & female for ACB of existing make complete all as specified and directed. |
| 63 | Supply and Fixing in repair cradle assembly for ACB of existing make complete all as specified and directed. |
| 64 | Supply and Fixing Energy meter 3 phase, of accuracy class 1.0, input voltage measurement 50-520 Volt, AC, flush mounting type including taking down old unserviceable complete all as specified and as directed. |
| 65 | Supply and Fixing Voltmeter 3 phase, of accuracy class 1.0, input voltage measurement 50-520 Volt, AC, flush mounting type including taking down old unserviceable complete all as specified and as directed. |
| 66 | Supply and Fixing Ammeter 3 phase, of accuracy class 1.0, AC, flush mounting type including taking down old unserviceable complete all as specified and as directed. |
| 67 | Material and labour for maintenance and servicing of resistor LOAD BANK of capacity 2000 KW, checking for preventive maintenance of system, motor operation repair if required including limit switch control, blade condition repair/ replacement if required, checking of SFU unit and fuses replacement of fuses if required, serviceability tightness of fuses and terminal, checking of resistors set, porcelain separator/insulator serviceability and replacement if required, Servicing of ACB and relays, Insulating pad check and repair/replace if required, complete all as specified and directed by Engr-in-Charge. |
| 68 | Material & Labour for checking of tightness of LT bushing side by opening cover of LT side transformer, opening cover of main LT Panel and checking for tightness of all bolts by torque wrinch, replacement of defective bolts and nuts, checking for bus duct adopter joints and tighten as required complete all as specified and directed by Engr-in-Charge. |
| 69 | Supply and Fixing cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured Al conductor cable of size 10-16 sqmm complete all as specified and directed by Engr-in-Charge. |
| 70 | Supply and Fixing cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Al conductor cable of size 25-35 sqmm complete all as specified and directed by Engr-in-Charge. |
| 71 | Supply and Fixing cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Al conductor cable of size 70 sqmm complete all as specified and directed by Engr-in-Charge. |
| 72 | Supply and Fixing cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured Al conductor cable of size 150 sqmm complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |