| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender inviting Authority: AGE (I) AYODHYA Name of Work: PROVISION OF ELECTRIC CONNECTION FOR MOLTI PROJECT AT UNIT AREA OF 5 MRARATHA LI AND PROVN OF 04 X 1.5 TON SPLIT AC WITH STABILIZER AT 146 INF BDE SIG COY UNDER AGE(I) AYODHYA CANTT Contract No: AGE(I) /AYD/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Serial Item No. Description of item of work in brief Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE in Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT in Words |
| 2 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soilcomplete all as specified and directed by Engr-in-Charge. |
| 4 | Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. |
| 5 | M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid separately |
| 6 | Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge. |
| 7 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sq mm, 3.5 core complete all as specified and as directed. |
| 8 | Supply & installation and testing & Commissining CPRI approved outdoor cubical type IP 54,LT feeder piller box suiable for 415 V, 3 phase 50 Hz , AC supply system, dust,weather & vermin proof, made of 3.15 mm thick CRCA sheet, powder coated with 7 tank process,TPN copper busbars of rating 250 Amp Cap.Bottom base channel of MS section not less then 45mmx45mmx5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x5mm at the rear with 2 no earth stud,double door both side opening single door system lockable/openable by key from both sides having flush pattern fancy locks with louvers. cable entry with glands, foundation/grouting on & including PCC as per site requirement with the following :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulator 250 Amp,4 pole, not less then 45 CM long mounted on insulators for incoming supply - 1 Set (Set of 4 strips) (b) Phase indicator lamp RYB LED type - 1 Set (Set of three). (c) Digital Voltmeter & Ammeter - 02 Nos(d) CT of suitable ratio (Set of three)Incoming: (a) MCCB 160 Amp, 415V, 50 Hz, FP, ,25 ka, Ics= 100% Icu fixed type, complete all as specified and directed by Engr-in-Charge.Note :- 1. Panel shall be installed at least 60 cm above ground 2. All civil/electrical work & material is deemed to be included in the quoted rates3. Drawing of LT feeder panel shall be got approved from Accepting Officer/AGE(I)4. panel shall confirm to IEC - 61439 updated to date. |
| 9 | M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including GI Strip of size 32 X 6 mm and light grade protection pipe of 40 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete including testing on completion all as specified and directed.(GI strip upto 7.5m including testing consider in this item). |
| 10 | Labour for Horizontal boring in soft/loose soil/under roads/path of any width by manual arrangements for inserting GI pipe up to 100mm bore for passing cables complete all as specified and directed by Engr-in-Charge. Note : GI pipe shall be measured and paid separately. |
| 11 | Supply & laying steel tubing, galvanized light grade bores, for passing LT/HT cable under road or PCC floor or fixed on wall/on pole or drain etc or whenever protection is required including necessary clamps and nut bolts with GI fitting complete all as directed and specified for size GI Pipe 50mm dia. |
| 12 | Supply and fix heat shrinkable End termination joint kits and accessories for Outdoor/ indoor type of 35 to 50 Sqmm 3.5 core size cable, 1.1 KV grade complete all as specified and as directed |
| 13 | Supply, install,commissioning and testing of hi wall split type air conditioner inverter type of capacity 1.5 TR single phase suitable for 230 V + 10 %, 50Hz AC supply complete with cordless remote control unit using Non CFC refrigerant Gas,minimum 5 star rating and energy efficient 3.2 complete comprising of following :-(a) indoor unit with three speed blower fan with motor of appropriate capacity including PCB,thermostatic control,air filter and drain for condensing water(b) Outdoor unit comprising hermetically sealed rotary compressor compressor ,air cooled copper condensor with fan and motor unit shall be installed outside the building / on roof(c) Refrigerant copper pipe for suction and discharge line with insulation ,condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safty accessories including control wiring for evaporator & condensing Unit with suitable size of copper cable. Note :- (i). The quoted rate shall be deemed to be inclusive of the cost of necessary cutting of hole and making good to the disturbed surfaces, copper tubing up to 5m, drain pipe extend upto ground level with fixing on wall with clamp, wall mounted iron stand suitable for outdoor unit.(ii) Electrical cable required to connect outdoor unit wih indore unit and indore unit to voltage stabilizer inclusive in above rate. (iii) Powder coated MS bracket/wall stand for fixing out door unit in wall or rooftop with necessary grouting MS hold fast ,bolts etc is included above rate. |
| 14 | Supply and fix Voltage stabilizer for automatic operation,Digital Display with colour changing LED rings,Intelligent time dealy system Protection, single phase naturally air cooled indoor type & designed for input variation between 130 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA including wall mouting cabinet all as specified and directed by Engr-in-charge. Make- V-Guard model no ID4 Ace 5540 or equivalent |
| 15 | M&L of sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC concealed and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note : Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.0 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose. |
| 16 | S&F Modular DBOXX AC Box for 25 A SP MCB, as per IS-13032& IS-8623 with surface mounted unbreakable heavy duty Sheet steel enclosure including 1 no. ISI marked Plug Top and 1 no. 25 A SP modular MCB complete all as specified and directed. |
| 17 | S&F copper pipe 5/8 inch dia for suction line AC indoor/ Out door including tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete all as specified and directed. |
| 18 | S&F copper pipe 1/4 inch dia for discharge line AC indoor/ Out door including tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |