| 1 | Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etcand removal of entire debris as ordered outside MD land complete all as directed. |
| 2 | Demolition of cement concrete (un-reinforced) of any description & in any description and removal of entire debris as ordered outside MD land complete all as directed. |
| 3 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick above or below ground level and removal of entire debris as ordered outside MD land complete all as directed. |
| 4 | Demolition of brickwork , precast concrrete block walling or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etcand removal of entire debris as ordered outside MD land complete all as directed. |
| 5 | Dismantling of fencing wire mesh any type etc complete all as specified. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and neatly stacking at site where directed. |
| 7 | Dismantling wall and ceiling board fibre, uplp insulation etc or insulation boards any thickness including cover fillets complete all as directed. |
| 8 | Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MD land complete all as directed. |
| 9 | Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out in hard/ dense soil and removing surplus soil to a distance exceeding 500 m and making good surface. |
| 10 | Removing excavated surplus soil to a distance exc 250 mts but not exceeding 500mts . and depositing where directedcomplete all as directed. |
| 11 | M & L for PCC 1 :4 : 8 type D2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed |
| 12 | Providing precast ce- ment concrete Type B1 1:2 :4 using 20 mm graded crushed stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry),string courses, copings. kneelers, apex stones, pier caps, columns, posts , boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets,etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match Set in cement mortar 1:4 complete all as directed. |
| 13 | M&L for broken glass coping on top of walls in cement mortar 1:3 including taking out old broken glass coping complete all as specified & as directed |
| 14 | M&L for Brick work with well burnt best quality locally available bricks, old size bricks, straight or curved on plan to any radius built in any description in cement mortar 1:4 complete all as directed |
| 15 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:6 complete all as specified & as directed. |
| 16 | S & F for Aluminium composite panel cladding on external façade with water tight system either curved or straight on concrete / masonry surfaces, size of panel as ordered. The panel aluminium composite panel shall be of 4mm thick with combination of aluminium skin material of 0.5mm thick aluminium sheet of alloy grade 3105 H 14 cover material natural polyethylene aluminium cladding panel coated on external side with PVDF (Poly vinyledene fluride) of KYNAR PVDF coating containing 70% KYNAR 500 resins for anti fungal & anti bacterial properties and the central core should be with opaque white polyethylene virgin grade , UV stabilized with a combination of 70% LDPE grade 22 FA 002 and 30% HDPE grade E5201 and the core should be bonded to the aluminium skip on both sides with DUPONT adhesive film of 30 to 50 of approved colour/shade fixed with extruded aluminium basis frame (50x25x1.50mm) angle cleats, weather sealants, rivets, GI brackets all as approved, using suitable chemical/anchor bolts on structural steel work including necessary accessories complete in all respects, the surface protection with 80 microns self adhesive peel off film with two layers of white and black tested to withstand for 45 days exposure to local weather condition, without loosing the original peel off characteristic or causing stains or other demages with silicon sealent of sil proof NB/Weeker El 305 or Dowcorning 789 or Wacker EL 305 or GE etc, including all scaffolding and structural steel backup frame as per manufacturers instructions. |
| 17 | S&F mild steel work in hard rails , winds ties post and structs in fencing screwed or welded to shaped as directed , including all necessary drilling ,bolting or welding etc, and similar work confroming Fe-290 Gde-E-165. |
| 18 | S&F rolled MS in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 290 Gde E-165. Please Enable Macros to View BoQ information |
| 19 | S&F rolled MS in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 290 Gde E-165. Please Enable Macros to View BoQ information |