| 1 | Providing, Fitting, Installation, testing and commissioning of 20,000 GPH x 91 mts. Head HC Pump set (slow speed) along with allied works at T/well cum P/stn. Deeli old. The Job involves dismantling of HC pump set by way of disconnecting all electrical connections, removing the existing old damaged pump set from base plate after disengaging pump and motor and then shifting it to proper location with the help of Crane and manual labour. Construction of reinforced cement concrete block of suitable size for HC pump set of 20,000 GPH x 91 mts head by way of excavation of existing block to finish with required dimensions at bottom with suitable depth at least 3 feet. Removal of the excavated material and disposing off the same to suitable place. Laying of thick layer of cement sand aggregate in the ratio of 1:1.5:3. Fabrication of Steel mesh which includes form work sand aggregate. Placing of base frame over the mesh and levelling the base frame horizontally as well as vertically. Providing and fixing of foundation bolts fabricated out of MS round with threads on length of one side. Properly anchoring the bolts with steel mesh by welding with welding electrodes. Providing and fixing of nuts for foundation bolts. Filling of cement concrete aggregate of proper ratio in the foundation block. Plastering of the foundation block in the ratio of 1:4. Complete job including cost of material i.e. cement aggregate, steel, shuttering material, foundation bolts, welding electrodes, providing of welding apparatus, and labour charges of skilled as well as semi - skilled labour, transport etc.Placing the HC pump set 20,000GPH x 91 mts and prime movers on the base frame and tighten with nuts and bolts, making the alignment, coupling the pump with motor, bushes and bolts and tightening them properly.Dismantling of old existing suction and delivery pipe line and then Laying in Position of M.S. Suction Pipe line as per the design of the pump from service reservoir at site up to Suction of HC pump 30 mtrs. (approx.) in length by way of providing, cutting to size assembling by welding/ flanged joints of M.S pipe along with flanges, bends, reducers/ expanders other required fittings in position, providing & Fitting of CI sluice valve as per the design of the pump suitable size with flanges and flange suitable to suction head flange of pumping unit with nuts/bolts, rubber gaskets, to ensure water-tight flange joints. Providing and laying in position of M.S delivery pipe line as per the design of the pump from delivery side of HC pump up to the manifold 30 mtrs in length (approx.) by way of providing, cutting to size assembling by welding/ flanged joints of M.S pipe along with flanges, bends, reducers/ expanders other required fittings in position, providing & Fitting of CS sluice valve and reflux valve as per the design of pump suitable size one no. each for pump on delivery line along with connection flanges and flange suitable to delivery head flange of pumping unit with nuts/bolts, rubber gaskets, to ensure water-tight flange joints . Complete job including cost of pump sets, material, labour charges, hire charges of tools and plants, carriage, loading/unloading, handling of material required for the execution of the complete work. The Pump, pipes and valves shall be of reputed make / ISI standard. The job includes Providing and fitting of single core 35 sq. mm capacity copper cable from motor to LT control panel 6 lengths 5 mtrs each after proper thimbling and crimping both ends of the cable. The cables shall be of reputed make / ISI standard. Complete job includes cost of material, labour charges and any other miscellaneous items / part required during execution of the job. The job should be completed in all respect. Note: All valve (including sluice and reflux valve) should have class 150.Designing, fabrication, installation. Testing and commissioning of automatic LT control Panel suitable for running H.C pump sets of capacity 20,000GPH x 91 mts head for 440- volt, AC-3 phase, 50 HZ, power supply . The panel should be dust and vermin proof fabricated out of 14/16 SWG CR sheet supported on MS angle suitable size and having provision for fixing it on the floor with the help of bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti-rust primer and two coats of steel grey enamel paint. The panel should be equipped with following components/ features.MCCB:- The panel should be fitted with a three phase four pole MCCB 250 Amps. Capacity and a set of RYB indicators at incoming side.Star Delta Starter:- The panel should be fitted with fully automatic star delta starter of suitable size comprising of three nos. three phase three pole Power contactors of capacity 140 Amps.- 02 Nos. and 110 Amps- 01 no., timer 01 no. for change - over of the supply of motor from star to delta, 02 nos. push buttons for start and stop operation of motor, 01 no. indicator, 01 no. MCB 6 Amps. for protection of internal control wiring with proper internal control wiring with flexible copper cables to complete the star delta circuit of outgoing supply.Protection devise/fault analyser: - A protection devise/fault analyser shall be fitted with the panel with capability to:-a. Protect the motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical fault which my otherwise damage the motor windings:-Voltage related fault: - Single phasing, under voltage, over voltage, unbalance voltage.Current related fault: - Over current/load, dry running, unbalance current/load, earth leakage, short circuiting.Mechanical fault: - Locked rotor, broken shaftDisplay line current of RYB Phase and also line voltage of RY and YB phase.Display and record trip counts and indicate trip status for over load, under load, single phase, unbalance, earth fault, over voltage, under voltage respectively.Analyze, display & record no. of operation and duration of motor running.Bimetal overload relay:- A bimetal overload relay of suitable range should be fitted in the panel as an extra protection to protect the motor in case of failure of fault analyzer with an isolation/ bye pass switch to by-pass the fault analyzer.The job also includes providing and fitting of 120 sq. mm 3.5 core Armoured aluminium Cable from Panel to Stabilizer 5 mtrs in length after thimbling and insulating properly both the ends of the cables. Testing control Panel on no load and then on full load. The Job also includes providing/fitting of 400 ampere four pole three phase HRC fuse unit steel encased disconnector (Main Switch) along with 150 sq. mm 3.5 core Armoured aluminium cable from main switch to Voltage Stabilizer 6 mtrs. In length and 150 sq. mm 3.5 core Armoured aluminium cable. from transformer to 400 Amp. Main switch 15 mtrs in length with proper thimbling and insulation Testing control Panel on no load and then on full load. Complete job including cost of material, labour, testing and commissioning charges. The MCCB/MCB, Timer , fault analyzer, power contactors relays shall be of reputed make Conforming to BIS/IEC standard. |
| 2 | Providing, Fitting, Installation, testing and commissioning of 12,000 GPH x 100 mts. Head slow speed HC Pump set (slow speed) along with allied works at T/well cum P/stn. Doodhi Gujjar. The Job involves dismantling of HC pump set by way of disconnecting all electrical connections, removing the existing old damaged pump set from base plate after disengaging pump and motor and then shifting it to proper location with the help of Crane and manual labour. Construction of reinforced cement concrete block of suitable size for HC pump set of 12,000 GPH x 100 mts head by way of excavation of existing block to finish with required dimensions at bottom with suitable depth at least 3 feet. Removal of the excavated material and disposing off the same to suitable place. Laying thick layer of cement sand aggregate in the ratio of 1:1.5:3. Fabrication of Steel mesh which includes form work sand aggregate. Placing of base frame over the mesh and levelling the base frame horizontally as well as vertically. Providing and fixing of foundation bolts fabricated out of MS round with threads on length of one side. Properly anchoring the bolts with steel mesh by welding with welding electrodes. Providing and fixing of nuts for foundation bolts. Filling of cement concrete aggregate of proper ratio in the foundation block. Plastering of the foundation block in the ratio of 1:4. Complete job including cost of material i.e. cement aggregate, steel, shuttering material, foundation bolts, welding electrodes, providing of welding apparatus, and labour charges of skilled as well as semi - skilled labour, transport etc.Placing the HC pump set 12,000GPH x 100 mts and prime movers on the base frame and tighten with nuts and bolts, making the alignment, coupling the pump with motor, bushes and bolts and tightening them properly.Dismantling of old existing suction and delivery pipe line and then Laying in Position of M. S. Suction Pipe line as per the design of the pump from service reservoir at site up to Suction of HC pump 8 mtrs. In length by way of providing, cutting to size assembling by welding/ flanged joints of M.S pipe along with flanges, bends, reducers/ expanders other required fittings in position, providing & Fitting of CI sluice valve of as per the design of the pump suitable size with flanges and flange suitable to suction head flange of pumping unit with nuts/bolts, rubber gaskets, to ensure water-tight flange joints. Providing and laying in position of M.S delivery pipe line as per the design of the pump from delivery side of HC pump up to the manifold 4 mtrs. In length (approx.) by way of providing, cutting to size assembling by welding/ flanged joints of M.S pipe along with flanges, bends, reducers/ expanders other required fittings in position, providing & Fitting of CS sluice valve and reflux valve as per the design of the pump one no. each for pump on delivery line along with connection flanges and flange suitable to delivery head flange of pumping unit with nuts/bolts, rubber gaskets, to ensure water-tight flange joints . Complete job including cost of pump sets, material, labour charges, hire charges of tools and plants, carriage, loading/unloading, handling of material required for the execution of the complete work. The Pump, pipes and valves shall be of reputed make / ISI standard. The job includes Providing and fitting of single core 35 sq. mm capacity copper cable from motor to control panel 6 lengths 5 mtrs. each (approx) after proper thimbling and crimping both ends of the cable. The cables shall be of reputed make / ISI standard. Complete job includes cost of material, labour charges and any other miscellaneous items / part required during execution of the job. The job should be completed in all respect. Note: All valve (including sluice and reflux valve) should have class 150.Designing, fabrication, installation. Testing and commissioning of automatic LT control Panel suitable for running H.C pump set of capacity 12,000GPH x 100 mts head for 440- volt, AC-3 phase, 50 HZ, power supply. The panel should be dust and vermin proof fabricated out of 14/16 SWG CR sheet supported on MS angle suitable size and having provision for fixing it on the floor with the help of bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti-rust primer and two coats of steel grey enamel paint. The panel should be equipped with following components/ features.MCCB:- The panel should be fitted with a three phase four pole MCCB 250 Amps. Capacity and a set of RYB indicators at incoming side.Star Delta Starter:- The panel should be fitted with fully automatic star delta starter of suitable size comprising of three nos. three phase three pole Power contactors of capacity 110 Amps.- 02 Nos. and 95 Amps- 01 no., timer 01 no. for change - over of the supply of motor from star to delta, 02 nos. push buttons for start and stop operation of motor, 01 no. indicator, 01 no. MCB 6 Amps. for protection of internal control wiring with proper internal control wiring with flexible copper cables to complete the star delta circuit of outgoing supply.Protection devise/fault analyser: - A protection devise/fault analyser shall be fitted with the panel with capability to:-a. Protect the motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical fault which my otherwise damage the motor windings:-Voltage related fault: - Single phasing, under voltage, over voltage, unbalance voltage.Current related fault: - Over current/load, dry running, unbalance current/load, earth leakage, short circuiting.Mechanical fault: - Locked rotor, broken shaftDisplay line current of RYB Phase and also line voltage of RY and YB phase.Display and record trip counts and indicate trip status for over load, under load, single phase, unbalance, earth fault, over voltage, under voltage respectively.Analyze, display & record no. of operation and duration of motor running.Bimetal overload relay:- A bimetal overload relay of suitable range should be fitted in the panel as an extra protection to protect the motor in case of failure of fault analyzer with an isolation/ bye pass switch to by-pass the fault analyzer. The job also includes providing and fitting of 120 sq. mm 3.5 core Armoured aluminium Cable from Panel to Stabilizer 5 mtrs. In length after thimbling and insulating properly both the ends of the cables. Testing of control Panel on no load and then on full load. The Job also includes providing/fitting of 400 ampere four pole three phase HRC fuse unit steel encased disconnector (Main Switch) along with 150 sq. mm 3.5 core Armoured aluminium cable from main switch to Voltage Stabilizer 6 mtrs in length and 150 sq. mm 3.5 core Armoured aluminium cable. from transformer to 400 Amp. Main switch 15 mtrs. In length with proper thimbling and insulation. Testing of LT control Panel on no load and then on full load. Complete job including cost of material, labour, testing and commissioning charges. The MCCB/MCB, Timer , fault analyzer, power contactors relays shall be of reputed make Conforming to BIS/IEC standard. Complete job |
| 3 | Providing, Fitting, Installation, Testing and Commissioning of 14,000 GPH X 130 mtr. Head HC Pump set (Slow Speed) along with allied works at T/well cum P/stn. Malik market. The Job involves dismantling of existing old damaged HC pump set by way of disconnecting all electrical connections, removing the pumpset from base plate after disengaging pump and motor and then shifting it to proper location with the help of Over Head Crane and manual labour. Construction of reinforced cement concrete block of suitable size for HC pump set of 14,000 GPH x 130 mts head by way of excavation of existing block to finish with required dimensions at bottom with suitable depth at least 3 feet. Removal of the excavated material and disposing off the same to suitable place. Laying of thick layer of cement sand aggregate in the ratio of 1:1.5:3. Fabrication of Steel mesh which includes form work sand aggregate. Placing of base frame over the mesh and leveling the base frame horizontally as well as vertically. Providing and fixing of foundation bolts fabricated out of MS round with threads on length of one side. Properly anchoring the bolts with steel mesh by welding with welding electrodes. Providing and fixing of nuts for foundation bolts. Filling of cement concrete aggregate of proper ratio in the foundation block. Plastering of the foundation block in the ratio of 1:4. Complete job including cost of material i.e. cement aggregate, steel, shuttering material, foundation bolts, welding electrodes, providing of welding apparatus, and labour charges of skilled as well as semi - skilled labour, transport etc.Placing the HC pump set 14,000 GPH X 130 mts and prime movers on the base frame and tighten with nuts and bolts, making the alignment, coupling the pump with motor, bushes and bolts and tightening them properly.Dismantling of old existing suction and delivery pipe line and then Laying in Position of M.S Suction Pipe line as per design of the pump 15 mtrs in length (approx.) from pump to service reservoir/available suction connection at site up to Suction HC pump as per site requirement by way of providing, cutting to size assembling by welding/ flanged joints of M.S pipe along with flanges, bends, reducers/ expanders other required fittings in position, providing & Fitting of CI sluice valve as per the design of the pump with flanges and flange suitable to suction head flange of pumping unit with nuts/bolts, rubber gaskets, to ensure water-tight flange joints. Providing and laying in position of M.S delivery pipe line as per the design of the pump from delivery side of HC pump up to the manifold 10 mtrs in length (approx.) by way of providing, cutting to size assembling by welding/ flanged joints of M.S pipe along with flanges, bends, reducers/ expanders other required fittings in position, providing & Fitting of CS sluice valve and reflux valve of as per the design of the pump one no. each for pump on delivery line along with connection flanges and flange suitable to delivery head flange of pumping unit with nuts/bolts, rubber gaskets, to ensure water-tight flange joints. Complete job including cost of pump set, material, labour charges, hire charges of tools and tackles, carriage, loading/unloading, handling of material required for the execution of the complete work. The Pump, pipes and valves shall be reputed make / ISI standard. Job also includes providing/fitting of mono submersible pumpset of capacity 14000 GPH X 8 MTR head, along with LT Control, panel cable and allied accessories in the Suction line of 14,000 GPH X 130 mtr. Head HC Pump set. The job includes Providing and fitting of single core 70 sq. mm copper cable from motor to control panel in length 30 meters (approx.) after proper thimbling and crimping both ends of the cable. Copper cables are reputed make / ISI standard. Testing of H C pumpset on no load and then on full load. Complete job includes cost of material, labour charges and any other miscellaneous items / part required during execution of the job. The job should be completed in all respect. Note: All valve (including sluice and reflux valve) should have class 150.Designing, fabrication, installation. Testing and commissioning of automatic LT control Panel suitable for running H.C pump sets of capacity 14,000GPH x 130 mts head for 440 volt, AC-3 phase, 50 HZ, power supply for above mentioned Horizontal Centrifugal pump set. The panel should be dust and vermin proof fabricated out of 14/16 SWG CR sheet supported on MS angle suitable size and having provision for fixing it on the floor with the help of bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti-rust primer and two coats of steel grey enamel paint. The panel should be equipped with following components/ features.MCCB:- The panel should be fitted with a four phase three pole MCCB 400 Amps. Capacity and a set of RYB indicators at incoming side.Star Delta Starter:- The panel should be fitted with fully automatic star delta starter of suitable size comprising of three nos. three phase three pole Power contactors of capacity 225 Amps.- 02 Nos. and 195 Amps- 01 no., timer 01 no. for change - over of the supply of motor from star to delta, 02 nos. push buttons for start and stop operation of motor, 01 no. indicator, 01 no. MCB 6 Amps. for protection of internal control wiring with proper internal control wiring with flexible copper cables to complete the star delta circuit of outgoing supply.Protection devise/fault analyzer:- A protection devise/fault analyzer shall be fitted with the panel with capability to:-a. Protect the motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical fault which my otherwise damage the motor windings:- Voltage related fault:- Single phasing, under voltage, over voltage, unbalance voltage.Current related fault:- Over current/load, dry running, unbalance current/load, earth leakage, short circuiting.Mechanical fault:- Locked rotor, broken shaftDisplay line current of RYB Phase and also line voltage of RY and YB phase.Display and record trip counts and indicate trip status for over load, under load, single phase, unbalance, earth fault, over voltage, under voltage respectively.Analyze, display & record no. of operation and duration of motor running.Bimetal overload relay :- A bimetal overload relay of suitable range should be fitted in the panel as an extra protection to protect the motor in case of failure of fault analyzer with an isolation/ bye pass switch to by-pass the fault analyzer. The MCCB/MCB, Timer , fault analyzer, power contactors relays shall be reputed make / ISI standard. The job also includes providing and fitting of 185 sq. mm 3.5 core Armored aluminium Cable from Panel to Stabilizer 10 mtrs in length (approx.) after thimbling and insulating properly both the ends of the cables. Testing control Panel on no load and then on full load. The Job also includes providing/fitting 240 sq. mm 3.5 Core Armored aluminium cable from Electric Transformer to main Switch 30 mtrs in length (approx.) with proper thimbling and tapping, providing/fitting of four pole three phase 630 Amp. MCCB for existing Voltage Stabilizer. Complete job including cost of material, labour, testing and commissioning charges. Complete job. Please Enable Macros to View BoQ information |