| 1 | Permanent restoration of Flood damage at Batengoo, Shoul, Uranhall/Khod, Baliyar and Panjpora Feeders of ESD Bijbehara, Langalbal, Batkote , Kothal Versiran , Nalah Overa , Overa , Shalberan , Wahdaan , Dalseer , Numbal , Sakhras , Amad Wagad of KPDCL Subdivision Aishmuqam and Replacement of 11/0.433 2X250 KVA (Dalseer Wahdan & KV Pora Marhama),1X100 KVA(kerkadal Takiyabal), 2X63 KVA(Gujjarbasti Langalbal & New Colony Hatigam) Distribution Transformers by Level II Fresh DTs of same capacity. |
| 2 | Supply,loading, unloading at site ,installtion, testing & commissioning of 250 kVA 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Copper wound , and with LV Cable Box having detachable Aluminium Gland plate at DALSEER Wahdan , and KV Pora Marhama |
| 3 | Supply,loading, unloading at site ,installtion, testing & commissioning of 100kVA,11/0.433KV, 3-phase Distribution Transformers (level-II) with LV Cable box having detachable Aluminium Gland Plate at Kerkadal Takiyabal Bijbehara |
| 4 | Supply,loading, unloading at site ,installtion, testing & commissioning of 63kVA,11/0.433KV, 3-phase Distribution Transformers (level-II) with LV Cable box having detachable Aluminium Gland Plate at Gujjarbasti Langalbal & New Colony Hatigam Bijbehara |
| 5 | Loading of old existing DTs from site of installation, carraiage and unloading at Divisional Stores Bijbehara of 2x250KVA ,1x100KVA and 2X 63 KVA from Dalseer wahdan,KV pora Marhama,Kerkadal Takiyabal,Gujjarbasti Langanbal and New Colony hatigam |
| 6 | Supply,loading, unloading at site Erection, testing & commissioning of S.T Pole 8mtr Long SP-15 with base plate & cap for LT. Strictly as per REC standards |
| 7 | Supply,loading , unloading at site ,Laying, stringing, tensioning & binding of ACSR 30mmsq (weasel) Conductor. |
| 8 | Supply/Fixing & commissioning of GI Channel/Angle/Flat of Sizes including clamps |
| 9 | Supplying and fixing of pole Earthing Complete by Spike Earthing Rod 20mm 2.5 Mtr long with GI strip (25x3)mm to each LT and HT pole |
| 10 | Painting of poles with one coat of red oxide and two coats of Aluminium paint as per Standards. This also includes numbering of ploes with paint, submission of Pre and Post Execution photographs duly anthenticated by AEE concrened. |
| 11 | Supply,fixing, testing & commissioning of 11KV Pin Polymer Insulators with GI pins complete. |
| 12 | Cement bottoming 1:2:4 mix as per REC Standards 0.4cum/pole |
| 13 | Supply and fixing of Almumunium Thimbles of suitable Sizes for fixing cables/Conductor with LT fuse Units |
| 14 | Providing & fixing of 11 kV polymeric composite disc insulator 12 kV , min failing load 45 kN, lighting impulse 75 kV positive and 80 kV negative, creepage distance 320mm |
| 15 | Providing & fixing of LT Shackle with mukhi clamps including nuts & bolts |
| 16 | Capturing of pre- and post-execution Geo Tagged photographs of the worksite and developing the same on photo paper for documentation purposes. Supply and fixing of a vitreous-enameled mild steel (MS) plate, minimum 1.6 mm thick, of size 200 mm x 150 mm, suitable for medium voltage installations. The plate shall be duly enameled/painted with the inscription 'SASCI 2026-27' prominently displayed, to be installed on all poles and DTs. The item also includes the cost of all necessary fixtures, including suitable clamps, for secure installation. |
| 17 | Providing and Fixing of GI Nuts and Bolts. |
| 18 | Supply, installtion of Danger Plates with Clamps |
| 19 | Supply and fixing of LT Fuse Unit as per the approved drawings of KPDCL Please Enable Macros to View BoQ information |