| 1 | Preliminary work per kilometer of 220 KV transmission line which including:- |
| 2 | Expenses for Geoglogical investigations and earth resistivity recording along the trans. Line. Survey instruments & equipment. submission of line profile and schedule. investigations. Surveying, reconnaissance of terrains, line route, detail survey including check survey, jungle clearance & fixing of stone burjees |
| 3 | Design, Engineering, Supply, vetting of design (by CPRI/CEA/JKPTCL/Power Grid/authorised agensies) of Towers, 220 KV, D/C, Non-Snow Zone type |
| 4 | A+3 type tower including stubs and nuts and bolts for 2 no towers |
| 5 | D type towers including stubs and nuts and bolts for 4 no towers |
| 6 | D+6 type tower including stubs and nuts and bolts for 1 no tower |
| 7 | NBB type tower including stubs and nuts and bolts for 2 no towers |
| 8 | B type tower including stubs and nuts and bolts for 1 no tower |
| 9 | C type tower including stubs and nuts and bolts for 1 no tower |
| 10 | Monopole including foundation bolts and nuts and bolts for 1 no. |
| 11 | 220 KV D/C Gantry superstructure along with stubs and nuts and bolts 2 nos. |
| 12 | 220 KV S/C Gantry superstructure along with stubs and nuts and bolts 1 no. |
| 13 | Tower acessories |
| 14 | Danger Plates 1 No Per Tower |
| 15 | Phase Plates 3 No Per Tower for S/C |
| 16 | Number Plates 1 No Per Tower |
| 17 | Circuit Plates 1 No. Per Tower for S/C |
| 18 | Anti Climbing Devices 1 No Per Tower |
| 19 | Conductor and Accessories |
| 20 | 400 mm² ACSR Conductor(a) Alumunium=54/3.18 mm(b) Steel=7/3.18 mm Overall dia 28.62mm.Approximate Wt 1621Kg/Km Ultimate breaking Load=130.32 KN;including 1.5%sag and jumpering |
| 21 | Mid Span Joints 3 No/Km |
| 22 | Vibration Dampers 2 No/Phase/Tower |
| 23 | Repair Sleeves For Conductor 9 No / Km for D/C |
| 24 | Aluminium Tape 1 No Per Km Of Line |
| 25 | Arching horn |
| 26 | Earth Wire and Accessoreis |
| 27 | Earth wire 7/3.15 |
| 28 | Mid Span Joints 2No/Km |
| 29 | Vibration Dampers 2 No / Tower |
| 30 | Insulators |
| 31 | Disc Insulators 120 KN KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected. |
| 32 | Disc Insulators 90 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.3 No for S/C,6 No for D/C supension strings |
| 33 | Hardware fittings for conductor |
| 34 | Single Suspension Fittings for Zebra shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 16mm. |
| 35 | Single Tension Fittings for Zebra shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. |
| 36 | Double Tension Fittings |
| 37 | Hardware fitting for Earth wire |
| 38 | Tension/Suspension Clamps S/C |
| 39 | Misc. work |
| 40 | Provinding of galvanised Missing member including n/bolts |
| 41 | Spares @ 5% of material from S no. 1.03 to 1.39 |
| 42 | Erection, testing, commissioning of Superstructure, conductor, Earthwire and acessories in all respect |
| 43 | A+3 type tower including stubs and nuts and bolts for 2 no towers |
| 44 | D type towers including stubs and nuts and bolts for 4 no towers |
| 45 | D+6 type tower including stubs and nuts and bolts for 1 no tower |
| 46 | NBB type tower including stubs and nuts and bolts for 2 no towers |
| 47 | B type tower including stubs and nuts and bolts for 1 no tower |
| 48 | C type tower including stubs and nuts and bolts for 1 no tower |
| 49 | Monopole including foundation bolts and nuts and bolts for 1 no. |
| 50 | 220 KV D/C Gantry superstructure along with stubs and nuts and bolts 2 nos. |
| 51 | 220 KV S/C Gantry superstructure along with stubs and nuts and bolts 1 no. |
| 52 | Tower acessories |
| 53 | Danger Plates 1 No Per Tower |
| 54 | Phase Plates 3 No Per Tower for S/C |
| 55 | Number Plates 1 No Per Tower |
| 56 | Circuit Plates 1 No. Per Tower for S/C |
| 57 | Anti Climbing Devices 1 No Per Tower |
| 58 | Conductor and Accessories |
| 59 | 400 mm² ACSR Conductor(a) Alumunium=54/3.18 mm(b) Steel=7/3.18 mm Overall dia 28.62mm.Approximate Wt 1621Kg/Km Ultimate breaking Load=130.32 KN;including 1.5%sag and jumpering |
| 60 | Mid Span Joints 3 No/Km |
| 61 | Vibration Dampers 2 No/Phase/Tower |
| 62 | Repair Sleeves For Conductor 9 No / Km for D/C |
| 63 | Aluminium Tape 1 No Per Km Of Line |
| 64 | Arching horn |
| 65 | Earth Wire and Accessoreis |
| 66 | Earth wire 7/3.15 |
| 67 | Mid Span Joints 2No/Km |
| 68 | Vibration Dampers 2 No / Tower |
| 69 | Insulators |
| 70 | Disc Insulators 120 KN KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected. |
| 71 | Disc Insulators 90 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.3 No for S/C,6 No for D/C supension strings |
| 72 | Hardware fittings for conductor |
| 73 | Single Suspension Fittings for Zebra shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 16mm. |
| 74 | Single Tension Fittings for Zebra shall have minimum failing load of 100% ultimate strength of Bundle cnductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. |
| 75 | Double Tension Fittings |
| 76 | Hardware fitting for Earth wire |
| 77 | Tension/Suspension Clamps S/C |
| 78 | Misc. work |
| 79 | erection galvanised Missing member including n/bolts |
| 80 | Tag welding of towers upto 2 stories including material (25 tower+3 gantries) |
| 81 | tightening of jumpers/conductor |
| 82 | Tightening of Super structures |
| 83 | Branch cutting of line corridor upto 16 mtr |
| 84 | Replacement of damaged Disc insulators |
| 85 | Painting of the black members including stubs |
| 86 | Dismantling of structure and write back to the divisional store at Narwal or use at different sites (as per site condition) |
| 87 | Destringing of conductor along with acessories and write back to the divisional store at Narwal or use at different sites (as per site condition) |
| 88 | Civil works including material and carraige in all respect |
| 89 | designing, vetting and Laying of foundation and Stub setting |
| 90 | A+3 type tower |
| 91 | D type towers |
| 92 | D+6 type tower |
| 93 | NBB type tower |
| 94 | B type tower |
| 95 | C type tower |
| 96 | Monopole |
| 97 | 220 KV D/C Gantry |
| 98 | 220 KV S/C Gantry |
| 99 | Earthing of Towers including material in all respect |
| 100 | Normal Type/Counter Poise(19 towers+3 Gantry) |
| 101 | Excavation work/benching |
| 102 | All kind of soil |
| 103 | Hard rock,manually. (Blasting Prohibited) |
| 104 | Disposal of escavated material average lead upto 500 mts. |
| 105 | Protection work |
| 106 | Excavation work |
| 107 | Providing/Laying PCC |
| 108 | Providing RRM |
| 109 | Backfilling (filter stone) Please Enable Macros to View BoQ information |