| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recess heavy class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge |
| 2 | Group C |
| 3 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy duty PVC conduit as required.Make:-Plaza/Finolex/polycab as approved by Engineer-In-Charge |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Make:-Anchor/Plaza/Finolex as approved by Engineer-In-Charge |
| 9 | 3 x 1.5 sq. mm |
| 10 | 3 x 2.5 sq. mm |
| 11 | 3 x 4 sq. mm |
| 12 | Supplying and fixing of following sizes of Heavy class PVC Conduit along with accessories in surface/recess including cutting the wall and making good as required.Make Diplast/BEC/Polyfit.or as approved by Engineer-In-Charge |
| 13 | 25 mm |
| 14 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit including conections,as required. |
| 15 | Supplying and fixing D- link DGS-1008A 8-port 10/100/1000 Base - T Unmanaged standalone gigabit switch in desk top (green ethernet) for getting blazing speed of giga bite that delivers power performance and reliability i.e increasing the speed of net work server in large in switching protocol storing and forwarding as required .Make:- D-Link Digilink/ Cisco/ as approved by Engineer-in-Charge. |
| 16 | Supplying and fixing Loaded Wall- Wall Mount 2u Dimensions 44 X57 X20 CM Front Glass Door(tinted,toughened) with LOCK &KEY, 2PAIRS OF I9\\" Mounting Rail with U-Marking welded Side walls !U Cable Manager (1) Hardware Packet (1Pkt)3 socket 5amp .power distribution Unit(1NO) .Make:- D-Link Cisco/ Digi link as approved by Engineer-In-Charge |
| 17 | Supplying and fixing Computer board comprising 2 nos 5 amp modular switches & Sockets , G.I box 2 module for jack box and G.I Box 6 module for 5 amp switchs and 5 amp sockets comprising frame and cover plate for each 2 module metal box and 6 module metal box , one no computer jack (RJ-45) with shutter including connections etc as required..Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) or as approved by Engineer-In-Charge |
| 18 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Er-In-Charge |
| 19 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) as approved by Engineer-In-Charge |
| 20 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) or as approved by Engineer-In-Charge |
| 21 | Supplying and fixing Computer board comprising metal box 200 mmx150 mmx75 mm for 3 nos 5 amp piano type switches and 3 Nos 5 amp sockets, 1 No RJ 45 socket, comprising 3 mm thick phenolic laminated sheet cover for metal box, G.I. metal box 2 module with sheet cover including connections etc as required. |
| 22 | Supplying and fixing following piano switch/ socket on the existing box including connections but excluding phenolic laminated sheet etc. as required. |
| 23 | 5/6 amp switch |
| 24 | 5 pin 5/6 amp Socket |
| 25 | 15 amp switch |
| 26 | 15 amp socket |
| 27 | Bell Push |
| 28 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 29 | Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required.Make :-Anchor (Roma classic )/L&T(Entice)/Legrand(Myrius) or as approved by Engineer-In-Charge |
| 30 | Supplying and fixing batten/ angle holder including connection etc. as required. |
| 31 | Providing and installation of following Watts LED Lamp with base cap as per post top lantern polycarbomate diffuser and aluminium heat sink , 100 lumen per watt, fincluding connections,etc. as required.:Make Jaquar/wipro/Philips as approved by Engineer-in-Charge( Five year warranty) |
| 32 | 9 watt |
| 33 | Providing, Installation, testing and commissioning of ceiling fan 1200 mm with socket type regulator,including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mmtwin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as req uired: Make:- Usha Five star/ Orient/Crompton as approved by Engineer-in-charge(Five YEAR WARRANTY) |
| 34 | Providing and fixing of surface mounted Luminaire LED batten 25 watts ,having high Quality design aluminium extruded decorative end caps and it should be compatible with specification i.e. P.F >.9,THD<10% Lumens per watt 130, and luminius flux 3250, CRI> 80 suitable for input voltage: AC 220-240 V, 50/60Hz, Burning hours >50000@L70 ,SPD 4KV complete with all accessories, connections, testing and commissioning etc as:Make Jaquar/Panasonic/Wipro /Philips as approved by Engineer-In-Charge( Five year warranty) |
| 35 | Supplying and fixing surface/recess round type LED of following watts, 6500k,with clear glass cover with die cast aluminium housing and it should be compatible with specification i.e. Power Factor > .9, Harmonic Distortion<10% and efficacy 100 Lumens per watt,& luminous flux 1800 lm suitable for input voltage: AC 220-240 V, 50/60Hz, life span >50000 hrs @L70,SPD 4KV complete with all accessories, connections, testing and commissioning etc. Make:- Jaquar/panasonic/Philips/wipro as approved by Engineer-in-Charge |
| 36 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral busbar, earth bar,din bar, detachable gland plate, interconnections, with appropriate rating copper lugs, gland , powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)Make L&T, Hager,ABB or as approved by Engineer-in -charge.(five year warranty) |
| 37 | MCBDB 12 WAY Double Door |
| 38 | Supplying and fixing , 240/415 volts, 10 kA, “C” curve,miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- L&T/ Legrand/ Hager/ ABB as approved by Er-In-Charge (five year warranty) |
| 39 | Single pole 5-32 amp |
| 40 | Supplying and fixing of following rating, four pole, (single phase and neutral),10 ka breaking capacity 240 volts, residual current Breaker with Overcurrent Protection (RCBO), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.-Make L&T/ Hager/ABB or as approved by Engineer-In -Charge.(five year warranty) |
| 41 | 63 AMP |
| 42 | Supplying and erection of following depth Indoor type Indoor cubical panel, as per the standards IEC 61439-1&2 as tested assembly, IP 42 fabricated CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning& finishing complete with 7 tank process powder coating in approved shade,, DMC/ SMC bus bar supports,bottom base channel of MS section not lessthan100 mmx 50 mmx 5 mm thick, fabrication shall be done in transportable sections, form of separation shall be form 4b with metallic separation only,the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level, thick.The size of control wiring in cubical panel FR-LSH 1.5 sqmm.The panel should be approved /Tested from the CPRI lab. make of switcgear L&T, Schneider,ABB as approved by Engineer-in -charge.( Five year warranty)-The panel should be approved /Tested from the CPRI lab.& should confirmed to IEC-61439 (Part I &II)Makeof switchgear:- L&T/ Legrand/ Hager/ ABB or as approved by Engineer-in -charge. |
| 43 | 300 Deep |
| 44 | Supplying and fixing of following rating and breaking capacity with spreader links thermal magnet in release complete with connection ,testing and commissioning etc as required. Make:- L&T, Legrand, Hager, ABB or as approved by Engineer-in -charge. |
| 45 | 200-250 Amp-25 KA |
| 46 | Supplying and fixing copper strip bus-bars suitable for 200 Amp. 415 volts capacity 4 No. each of cross-sectional area (25mmx5mm),in the existing enclosure with all accessories including connections etc. as required:- |
| 47 | S/F indicator set RY &B with 3 Nos Kit kat (LED type) to shown the three indicating in the existing pannel complete etc as required.Make L&T/ Schneider/ABB as approved by Engineer-in -charge. |
| 48 | supplying and fixing CT coil 500/5 amp with burden of VA 15 accuracy class -1 Make:- Automatic Electric Ltd/ L&T/ Legrand . |
| 49 | Supplying and fixing of ammeter inbuilt selector switch CT/PT site programmabe accuracy class1.0;0.5 complete with connection testing and commissioning etc Make L&T/ Schneider/ABB as approved by Engineer-in -charge. |
| 50 | Supplying and fixing of voltmeter inbuilt selector switch CT/PT site programmabe accuracy class1.0;0.5 complete with connection ;testing and commissioning etc as required Make L&T/ Schneider/ABB as approved by Engineer-in -charge. |
| 51 | Supplying and fixing true power make advanced earthing system having GI pipe 3 meter long 50 mm dia with terminal size 50x6 mm ,internal strip size 25x3 with 50 Kg compound including exvation of pit and refiling the same and making earthing pit cover 12 inch dia as required complete in all respect. make :-True power /Earth plus/Ashloka as per best satisfaction of Engineer-in -charge. |
| 52 | Providing and fixing 6 SWG G.I wire on surface or in recess for loop earthing as required. |
| 53 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.Make:Finolex /Plaza/Havells or as approved by Engineer-in-Charge |
| 54 | Armoured cable 120 sqmm(3.5 core) Please Enable Macros to View BoQ information |