| 1 | Pumping MachineryBore Well-IProviding and installing submersible pump in 125 mm dia bore well confirming to IS 8034-2002 with uptolatest ammendments along with a directly coupled submersible type squirrel case electric induction motorsuitable for operation on 3 Phase connection. AC supply with water lubricated bearings, provided withpivoted segment type thrust bearings to with stand vertical pressure with minimum wear and tear andwith device to take up the expansion of water with heating of motor complete in all respect of makeCROMPTON / KSB/Kirloskar and other reputed make approved by Jal Shakti Vibhag.125 mm dia near intake of LWSS Kaller Chharol on the left bank of Gambhrolla Kahd in Village Sai Kanaita1x7.50 HP=7.50 HPDischarge:- 3.00 LPS,Total Dynamic head:- 115.00 Mtr,Dia of Rising main:-80 mm dia, Length of R/Main:-50 Rmt, Pumping Hours:-16 Hours,The job shall include following items:-(Note the rate of below mentioned items shall be quoted against item No. 1 only) |
| 2 | Supply , Installation, Testing and Commissioning of Push Buttoon type starter having required capacity ofL&T, HAvvels & other approved make of JSV. The Starter Panel shall be made out of 16 Gauge sheet,powder coated dust and vermin proof, wall/base mounted and front opening door type with copperinsulated wiring suitable to operate as per requirement. Starter shall be comprising of various requisiteaccessories such as suitable volt meter, Amp meter, indicators MCB TPN, DOL starter etc Starter shouldbe capable enough to handle the following faults like short circuit, over current, under current, overvoltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, PowerQuality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted complete in all respects in lead and lifts and entire satisfaction of Engineer-in-Charge.Quantity- 1 No. |
| 3 | Providing and fixing copper PVC insulated submersible cable of approved brand such as havells, L&T andother approved brand by JSV from pump inside bore well upto the starter to be installed within thepumping station. The length of cable shall be as per actual requirement at site.Quantity- 1 Job |
| 4 | Supply of Kirlosker/Kilburn/BHEL/Leader make cast iron PN 1.60 double flanged swing check type refluxvalve having size equal to delivery of Pump including cost of fitting, flanges, welding and nut bolts etc. Quantity- 1 No. |
| 5 | Providing, installation/lowering & testing of suitable size (as per delivery of pump) PPR pipe of superiorquality and grade as per nominal pressure of brand Astral, Finelax, Appolo, Vectus, Jain Irrigation etc.Complete in all respects having length to be decieded by department during lowering of submersible pump.Quantity- 1 Job |
| 6 | Supplying and fixing rope wire of required thickness suitable to bear the weight of submersible motorpumps set and its accessories.Quantity- 1 Job |
| 7 | Supply and fixing of supporting clamps to submersible pump set as per entire satisfaction of Engineer-in-Charge.Quantity- 1 Job |
| 8 | Testing of all the above equipments.Quantity- 1 Job |
| 9 | Bore Well-IIProviding and installing submersible pump in 175 mm dia bore well confirming to IS 8034-2002 with uptolatest ammendments along with a directly coupled submersible type squirrel case electric induction motorsuitable for operation on 3 Phase connection. AC supply with water lubricated bearings, provided withpivoted segment type thrust bearings to with stand vertical pressure with minimum wear and tear andwith device to take up the expansion of water with heating of motor complete in all respect of makeCROMPTON / KSB/Kirloskar and other reputed make approved by Jal Shakti Vibhag.175 mm dia near intake of LWSS Kaller Chharol on the left bank of Gambhrolla Kahd in Village Sai Kanaita1x10.00 HP=10.00 HPDischarge:- 5.00 LPS,Total Dynamic head:- 95.00 Mtr,Dia of Rising main:-80 mm dia, Length of R/Main:-50 Rmt, Pumping Hours:-16 Hours,The job shall include following items:-(Note the rate of below mentioned items shall be quoted against item No. 1 only) |
| 10 | Supply , Installation, Testing and Commissioning of Push Buttoon type starter having required capacity ofL&T, HAvvels & other approved make of JSV. The Starter Panel shall be made out of 16 Gauge sheet,powder coated dust and vermin proof, wall/base mounted and front opening door type with copperinsulated wiring suitable to operate as per requirement. Starter shall be comprising of various requisiteaccessories such as suitable volt meter, Amp meter, indicators MCB TPN, DOL starter etc Starter shouldbe capable enough to handle the following faults like short circuit, over current, under current, overvoltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, PowerQuality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted complete in all respects in lead and lifts and entire satisfaction of Engineer-in-Charge.Quantity- 1 No. |
| 11 | Providing and fixing copper PVC insulated submersible cable of approved brand such as havells, L&T andother approved brand by JSV from pump inside bore well upto the starter to be installed within thepumping station. The length of cable shall be as per actual requirement at site.Quantity- 1 Job |
| 12 | Supply of Kirlosker/Kilburn/BHEL/Leader make cast iron PN 1.60 double flanged swing check type refluxvalve having size equal to delivery of Pump including cost of fitting, flanges, welding and nut bolts etc. Quantity- 1 No. |
| 13 | Providing, installation/lowering & testing of suitable size (as per delivery of pump) PPR pipe of superiorquality and grade as per nominal pressure of brand Astral, Finelax, Appolo, Vectus, Jain Irrigation etc.Complete in all respects having length to be decieded by department during lowering of submersible pump.Quantity- 1 Job |
| 14 | Supplying and fixing rope wire of required thickness suitable to bear the weight of submersible motorpumps set and its accessories.Quantity- 1 Job |
| 15 | Supply and fixing of supporting clamps to submersible pump set as per entire satisfaction of Engineer-in-Charge.Quantity- 1 Job |
| 16 | Testing of all the above equipments.Quantity- 1 Job |
| 17 | Rising Mains from bore wells to WTPExcavation in foundation and trenches etc.(in pipes and pits) in all kinds of soils such as pick work, jumperwork, blasting in soft / hard rock, chiselling/wedging out of rock/where blasting prohibited) saturated soilstacking the excavated earth within all leads and lifts clear from the edge of excavation and then returningthe stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating eachdeposited layer by ramming and watering and then disposing of all surplus excavated earth as directed bythe Engineer –in-charge. |
| 18 | Laying in excavated trenches of below mentioned GMS tube with Butt welded Joint by means of electric arcwelding complete in all respect within all leads & lifts as per entire satifaction of engineer in charge. (Costof butt welding and excavation shall be paid seperately) 80 mm dia GMS(M/L) IS 1239 |
| 19 | Providing Circumferencial Butt Welded joints by electrical arc welding for 80 mm dia GI PipesLight/medium / heavy class, welded in requisite number of weld runs (Minimum Three) so as to achievethe minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using weldingelectrodes of 2.5 mm to 6.3 mm of Advani Oerlikon (Adore) - CITOJET / ESAB make, conforming to IS 814-1991, at site of work complete in all respects, including manual / mechanical handling of pipes in all leadsand lifts to the entire satisfaction of Engineer-in-Charge. Please Enable Macros to View BoQ information |