| 2 | Excavating over areas, n exc 1.5 m deep and getting out in dense soil complete all as specified and as directed. |
| 3 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in Hard / Dense soil complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm using available soil obtained from excavation complete all as specified and as directed. |
| 5 | Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 6 | M&L PCC 1:4:8 type D2(using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed. |
| 7 | M&L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in Cement Mortar 1:4 all complete all as specified and as directed. |
| 8 | M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in built in Cement Mortar 1:4 complete all as specified and as directed. |
| 9 | M&L 10mm thk internal plastering in CM 1:6 finished even & smooth without using extra cement complete all as specified and as directed. |
| 10 | M&L 10mm thk backing coat in CM 1:6 for external plastering and 5mm thk in CM 1:4 finished mixed with WPC complete all as specified and as directed. |
| 11 | M&L 5mm thk plaster in CM 1:3 finished even and smooth without using extra cement, on ceiling complete all as specified and as directed. |
| 12 | M&L preparation of RCC roof surface with wire brush, Picking,sweeping clean and washing down with water to remove dust. While doing the treatment on existing roof , concrete should be thoroughly inspected for any significant distress. Such distress, if any repaired / rehabilitated and treated. NOTE: (a) Pipes Over roof Should be realigned. (b).Supplying and applying High build elastomeric waterproofing coating based on pure, hydrophobic Aliphatic Single Component Liquid applied polyurethane Membrane Asian Paints Smartcare 1K PU Aqua, cold applied of spray / brush applied, membrane with an elongation of >400±50% and tensile strength of > 1.5 mpa as per ASTM D 2370, crack bridging ability of upto 4mm as per AS-NZ 4548, Solid Content - 60 ± 2 % as per ASTM C 1250, SRI index (>100) . The system includes final base preparation,Asian Paints SC HFP 130/120 Primer using a Roller or Brush @ 150-200g/sqm consumption and applying Asian Paints SmartCare 1K PU Aqua in two to achieve a min.consumption as 1.8kg/sqm/2coats to achieve 800±10% Microns thick. after the epoxy primer coating for the better adhesion and etc. complete as per Manufacturere specifications. Application of Primer, Asian Paints Smartcare HFP 130/120 are packed in two separate pack, having the correct predetermined mixing ratio by weight and apply the primer by using a Roller or Brush @ 150-200g/sqm consumption. Filling of bug holes and pinholes with OPC mixed with SC HFP 130 B+H. Tentative mixing ratio would be 3:1 (Silica sand) and If the substrate has white patches, then apply a second coat of primer after 4 hours and before 6 hours of 1st application. After completion of satisfactory surface preparation and complete drying, Asian Paints SmartCare PU Aqua Coating is applied with lamb wool roller/brush/Machine at a dosage consumption as 1.8kg/sqm/2coats to achieve 1mm thick. Allow the first coat to be cured at-least of 6-8 hours subjected to weather condition, then apply the second coat of Polyurethane coating in cross wire direction. |
| 13 | Allow the SmartCare PU Aqua to cure to a firm rubber, [Min. 24 hours at 23°C, 50% RH], the coating achieves full cure in 7 days. Any subsequent activities (including testing, if any) on the coating can be carried out after 7 days prior to water ponding complete all as specified and as directed. |
| 14 | Water proofing compound added with finishing coat external plaster complete all as specified and as directed. |
| 15 | M & L Hard core, broken to gauge n exc 63 mm complete all as specified and as directed. |
| 16 | M&L Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) 100 mm complete all as specified and as directed. |
| 17 | M&L Glazed Ceramic Tiles, Coloured, of size 350x 250x 7mm/ 450X 350X 7mm thick as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of 10mm thick in cement mortar 1:3 complete all as specified and as directed. |
| 18 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick (Square / rectangular) area of each tiles exc 0.06 Sqm but n. exc 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm thick screed bed of CM (1:4) bedding complete all as specified and as directed. |
| 19 | M & L RCC chajjas complete all as specified and as directed. |
| 20 | M&L RCC design mix M-30 Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 21 | M&L RCC M-30 Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and as directed. |
| 22 | M&L RCC M-30 Design mix in Columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 23 | M&L RCC Design mix M-30 in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns etc; basement slabs, under reamed piles and mass concrete complete all as specified and as directed. |
| 24 | M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, cooking platform and similar work; not exceeding 200mm thick complete all as specified and as directed. |
| 25 | M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter complete all as specified and as directed. |
| 26 | M&L formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc. complete all as specified and as directed. |
| 27 | M&L formwork Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 28 | M&L MS TMT bars 10mm dia and over out to length, bent to shape required, including cranking, bending including necessary welding as required & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with the clips complete all as specified and as directed. |
| 29 | M&L Steel reinforcement works- mild steel bars (TMT) cut into length bent into required shape, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire, 8mm as in stirrups complete all as specified and as directed. |
| 30 | M&L Preparing newly plastered surfaces for applying two coat of oil bound distemper over a coat of alkali resistant primer on walls complete all as specified and as directed. |
| 31 | M&L Preparing newly plastered surfaces for applying two coat of cement base paint over a coat of alkali resistant primer on walls all as specified and directed. |
| 32 | M&L Preparing the newly plastered surfaces and applying three coats of white wash on Undecorated Surfaces ceiling complete all as specified and as directed. |
| 33 | M&L broken stone or boulder hard core of gauge not exceeding 63mm, deposited, spread levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 34 | M&L 100 mm thick, PCC 1:4:8, Type D-2 (using 40mm graded stone aggregate) as in Sub base for flooring complete all as specified and as directed. |
| 35 | M&L Plinth protection including PCC 75mm thick complete all as specified and as directed. |
| 36 | M&L 25 mm thick in PCC type B0 Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and as directed. |
| 37 | M&L Pressed steel frames 105X 60 for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. |
| 38 | M&L Plain Cement Concrete Type C1 1:3:6 (using 20 mm graded stone aggregate) cast in situ in lintels up to 1.5m span, cills and other similar bands, plinth courses, parapets, copings, bed plates, back filling of pressed steel door frames, troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and as directed. |
| 39 | S&F flush shutter 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides including 6mm thick wooden lipping around the edges of shutter complete all as specified and as directed. |
| 40 | Supply and fixing factory made uPVC white colour Two track two panels sliding window above 1.50 m height made of (big series) fram 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 + 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 2.50 sqm. upto 4.00 sqm.) comprising of uPVC multicha mbered frame, with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and as directed.. (Glass or wiremesh shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. complete all as specified and as directed. |
| 41 | S & F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 42 | M&L Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red/zinc oxide primer complete all as specified and as directed. |
| 43 | M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and as directed. |
| 44 | M&L Factory Made Solid PVC Moulded Door Shutter,wood free EPS 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face, supplying & fixing in frame at site as per specification complete all as specified and as directed. |
| 45 | S& F 100 mm length butt hinges, heavy weight, cold rolled mild steel, and fixed complete all as specified and as directed. |
| 46 | S & F 150 mm long Aluminium anodised barrel tower bolts of extruded sections complete all as specified and as directed. |
| 47 | S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 150mm long complete all as specified and as directed. |
| 48 | S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 49 | S & F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 50 | S & F Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated with crutch or butterfly handle, screwed down for iron pipe etc complete all as specified and as directed. |
| 51 | S & F Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, screwed down high pressure with crutch or butterfly handle for iron pipe etc complete all as specified and as directed. |
| 52 | S & F Tubular towel rail, brass chromium plated 20mm dia, D type, 60cm long between flanges complete all as specified and as directed. |
| 53 | S & F in repairs Vitreous China Wash hand basin, white flat back size 550x400 mm including brackets including Pillar Tap 15 mm bore Chromium plated cast copper alloy with capstan heads, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts & PVC waste pipe and 600mm long PVC connection 15mm, complete all as specified and as directed. |
| 54 | S & F water closet ‘Orissa’ pattern, size 630X450 mm white, with integral foot rests setting the trap and pan in cement concrete min 150 mm thick all round and finished just below level of rim of pan to reive the floor finishing inluding 10 lit flushing cistern, p or s trap etc all other fitting as per specification and manufactural instruction complete all as specified and as directed. |
| 55 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 56 | S & F GI water tubing of 20 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed. |
| 57 | S & F GI water tubing of 25 mm bore, medium grade conforming to IS - 1239 [Part - 1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed. |
| 58 | S & F 500 Lit rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed. |
| 59 | S&F 25 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 60 | S & F 25 mm bore dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 61 | Demolition of cement concrete (unreinforced) in ground floor & paving not exceeding 15 cm thick below or above ground level. complete all as specified and as directed. |
| 62 | Rolling and consolidating formation surfaces in cutting with exc 8 but nexc 12 tonne power roller complete all as specified and as directed. |
| 63 | M & L soling (or sub base) 150mm with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed. |
| 64 | M&L laying and compacting 150 mm thick (compacted thickness) Granular Sub Base Course (GSB) grading as per Grade III as specified Table 400-1 of MoRTH specifications for Road and Bridge works, 2013, in a single layer over compacted subgrade with naturasand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-1 00 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MaRTH specifications for Road and Bridge works, 2013. complete all as specified and as directed. |
| 65 | M & L laying and compacting 150 mm thick WMM laid in two layers of 75 mm each. (compacted thickness) Wet Mix Macadam (WMM) grading as pe table 400-13 of MoRTH specifications for Road and Bridge works 2013 manufactured in WMM plant material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and rolling with vibratory roller of capacity 80-100KN static weight and consolidating to required gradient and camber complete all as specified and directed. The finished surface tolerances to be as per Table 900-1 of MaRTH specifications for Road and Bridge works 2013 complete all as specified and as directed. |
| 66 | M & L Applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate o application of 0. 7-1 kg/sqm on surface o WMMIWBM as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer complete all as specified and directed . |
| 67 | M & L Applying evenly a tack coat of Cationic Bitumen Emulsion (RS-1) conforming to IS: 8887 at a rate of application of 0.2-0.3 kg/sqm on bituminous surface as specified in Table 500-5 of MaRTH specification for road and bridge wo rks 2013, using mechanica sprayer after cleaning of existing surface as specified and directed. |
| 68 | M&L for premix bituminous, macadem with 4% paving bitumen VG 30 laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less) complete all as specified and as directed |
| 69 | M&L Bituminous premix semi dense asphaltic concrete 40 mm consolidated thickness, with 5.5% binder content by weight of total mix using of VG 40 grade paving bitumen, spread rolled and compacted to required camber and gradient using machanical pavour and power vibratory roller complete all as specified and as directed |
| 70 | M&L preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed |
| 71 | M &L for cement concrete Type B0 1:2:4 (12.5 mm graded aggregate) in kerbs fixed and set in CM 1:4 including necessary formwork complete all as specified. |
| 72 | All as per item no 01 above but exc 1.50 m and n exc 3mm, complete all as specified and as directed. |
| 73 | M&L Plain cement concrete 1:3:6 type C2 (using 40 mm graded aggregate) in foundation, filling and mass concrete and sub base complete all as specified. |
| 74 | Demolition of cement concrete (unreinforced) in ground floor & paving not exceeding 15 cm thick below or above ground level. complete all as specified and as directed. |
| 75 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided. complete all as specified and as directed. |
| 76 | Dismantling floor, earth or wall tiling including CM bedding, removing rubbish off the premises complete all as specified and as directed. |
| 77 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 78 | M&L rendering 15mm thick in CM 1:6 on fair faces of brick or concrete work making surfaces even and fair without using extra cement, complete all as specified and as directed. |
| 79 | M&L rendering 15mm thick in CM 1:6 on fair faces of brick or concrete work making surfaces even and fair without using extra cement, complete all as specified and as directed. |