| Sl. No. | Item Description |
| 1 | Providing, installing, commissioning and testing of VERTICAL TURBINE, self water lubricated above floor type pump at Jackwell Siddheshwar Dam with VHS motor capable of discharging water at the rate of 105 Cum/ Hr. at the duty point head of 92.50 M with suspension length of 14.00 mtrs. including bowl assembly and operating within the head range of 86 to 100 Mtr. with 1460 rpm with Vertical hollow shaft squirrel cage induction motor of capacity to run the pump of minimum 45 KW / 60 HP with \\"F\\" class insulation and B class temperature rise with thermostat protection embedded in stator winding complete operating on 440 V, 50Hz, 3 Ph, 1500 RPM AC power supply suitable to drive the pump complete with all accessories. Pump including stainless steel basket type strainer, bowl assembly, column assembly, discharge head , base plate of suitable size with minimum thickness of 24 mm, connecting stool etc. complete as per latest IS specifications. The column pipes shall be anufactured from ERW pipes of 10 mm thick and each of maximum 1.5 m length provided with anticorrosive and special treatment paint and all line shafts impellers shafts of stainless steel SS 410 and impeller should be of Bronze including all consumable materials, consumable materials, accurate digital type glycerin Pressure gauge to read entire range of pressure complete with necessary tubing. The pump should have flat efficiency characteristics between operating range as per detail item specifications |
| 2 | \\"Providing, installing, commissioning and testing of VERTICAL TURBINE, self water lubricated above floor type pump at Hingoli WTP with VHS motor capable of discharging water at the rate of 100 Cum/ Hr. at the duty point head of 60.00 M with suspension length of 3.10 mtrs. including bowl assembly and operating within the head range of 58 to 61 Mtr. with 1460 rpm with Vertical hollow shaft squirrel cage induction motor of capacity to run the pump of minimum 37 KW / 50 HP with \\"\\"F\\"\\" class insulation and B class temperature rise with thermostat protection embedded in stator winding complete operating on 440 V, 50Hz, 3 Ph, 1500 RPM AC power supply suitable to drive the pump complete with all accessories. Pump including stainless steel basket type strainer, bowl assembly, column assembly, discharge head of 200 mm dia, base plate of suitable size with minimum thickness of 24 mm, connecting stool etc. complete as per latest IS specifications. The column pipes shall be manufactured from ERW pipes of 8 mm thick and each of maximum 1.5 m length provided with anticorrosive and special treatment paint and all line shafts impellers shafts of stainless steel SS 410 and impeller should be of Bronze including all consumable materials, consumable materials, accurate digital type glycerin Pressure gauge to read entire range of pressure complete with necessary tubing. The pump should have flat efficiency characteristics between operating range as per detail item specifications \\" |
| 3 | Designing, Providing Erecting & commissioning LT panel 50 HP FCMA SOFT STARTER L.T. Panel with 1 Incomer and 2 Outgoing of 50HP FCMA , Auxiliary Feeder Panel fabricated from 14 Gauge CRCA MS sheet with powder coating including all accessories, switchgear, indicating lamps, push buttons, cables, meters, Copper busbar, foundation channel, with all self-contained inter connections, internal wiring with ferrules, suitable engraved designation labels etc |
| 4 | Supplying, erecting, testing & commisioning 25 kVAr, 440 V, 3 phase, 50 Hz., APFC panel with contactor logic with intelligent microprocessor relay, consisting of 1,2,2,5,5,5,5 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard per specification no. CP-ED/APFC. |
| 5 | Providing, erecting and commissioning single girder Electrically Operated Rectangular Over head Travelling Crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendant control block.LF 4-1) 5 Tonne CapacityLF 4-1-2) Above 6 m upto 8 m span |
| 6 | Square Bar / RailProviding, erecting and fixing square bar of EN 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and \\"J\\" bolts.LF 5 -1) 50 X 50 mm ( EN 8) |
| 7 | Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, nloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative Tolerance in thickness is permissible).Dia of Pipe : 200 mm (I. D.) Thickness of pipe6) 10 mm |
| 8 | Dia of Pipe : 400 mm (I. D.) Thickness of pipe :4) 10 mm. |
| 9 | Lowering, laying in position to correct line and level including M. S. pipes with / without any outcoating on pedestals or chairs upon prepared formation. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, and transportation upto 500 M. etc. completed as specified. 5 mm to 10 mm thicki)) Upto 400 mm. dia. |
| 10 | Welding in all positions with required number of runs, for M. S. pipes internally and / or externally including gauging wherever necessary, fixing appurtenances and other accessories in connection with pipe laying work as per specification.10 mm. |
| 11 | Gas cutting (either square cut or V cut) pipes, plates, etc. of thickness.ii) Above 5 mm. Upto 10 mm. |
| 12 | Providing, erecting and commissioning M.S. Dismantling joint as per requirement and Department's approved drawing and specifications, including machining and rubber rings and suitable for 16 kg/cm2 working pressure with required flanges of suitable size with nut bolts etc complete. The joint should have through long bolts so that during normal working pressure there should be no sliding movement of sliding flanges. L.O.F. ( length over flange ) should not be less than 75% of dia.PW 6-3) 200 mm dia Joint |
| 13 | Providing structural steel work in rolled sections like joists, channels, angles, tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc. and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete. (Bd-C-2/275) |
| 14 | Providing and supplying ISI standard M S s pecials of required thickness with 3 coats of approved make epoxy paint (Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside excluding all statutory duties & taxes such as GST levied by GOI & GOM in all respect, inspection charges, transportation to stores / site, and stacking, etc. complete.4) All socketed specials or socketed branch flanged specials of all diameters. |
| 15 | Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled, including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc. complete.Kinetic Air Valve Flanged Type - PN -1.63) 80 mm. |
| 16 | Lowering, laying and f ixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves).Air Valve Double Ball (PN-1 and PN - 1.6)8) 80 mm. |
| 17 | Providing and applying paints of approved make including all materials and labour complete and furnishing three years guarantee. (Rates excluding GST)Ready mixed red oxide chrome primer (one coat) |
| 18 | Two coats of Pure epoxy paint including one coat of primer(with the prior permission of the Chief Engineer / Addl. CE) |
| 19 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 100 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 17.4 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 ltr etc., on provided M20 grade CC foundation as per specification no. GEN-DG |
| 20 | Supplying and erecting ON LOAD automatic transfer switch 4 pole, 415V, 100-125A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 as per specification no. SW-SWR/ATS. |
| 21 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite / gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)In RCC M-200 |
| 22 | Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required, etc. complete (including cost of binding wire). (Bd-F- 17/306)Tor Steel |
| 23 | Supply, installing, and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity (min. 125kg) complete, and recording the results specification no. EA-MF |
| 24 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 25 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 26 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 27 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 28 | Providing supplying, erecting & commissioning of surge protection systems comprising of Bladder Vessel with minimum volume of 5M³ pressure rating minimum 16 Bar with Shell SA516 Gr. 70/Equivalent elliptic Cap-SASA516 Gr.70 equivalent with butyl bladder in vertical position. Vessel connection size 200 mm & connecting pipe size 200 mm with pre charge pressure 40m isolation valve, flanges, fasteners, etc., including all lead & lifts & Civil Foundation including all accessories complete. |
| 29 | Providing supplying, Erecting & commissioning of 3 stage surge suppression air valve of Dia 100 mm pressure rating minimum 16 Bar on delivery pipe with MS Pipe Spool Piece and Its Isolation butterfly Valve. Air valve is non-slam surge suppression high flow combination 3 stage air valve. Make: Bermad |
| 30 | Supplying erecting testing and commissioning DI/D/F Slanted seat swing rubber Flap check valve (Non Return Valve) of size 200 mm dia PN 1.6 similar to RETO STOP Including required size and number of Slipon Flanges having body of ductile cast Iron GGG-40 and disc of ductile cast iron GGG-40 with fully encapsulated with EPDM Rubber (Potable water certified).Slanted seat is fixed for easy opening and quick closing .Full bore opening to achieve high discharges & reduced pressure drops. Check valve Electrostatic epoxy power / liquid coating (EP-P) inside and out side color blue RAL5005 with minimum coating thickness of 250microns.The EPDM rubber & Epoxy coating should be potable water certified. Face to face dimensions as per EN558-1, series 48 and flange connections as per EN 1092-2/IS1538 including all labour, material complete.PN rating1.6 Material of Construction :- Body & Cover :-Ductile iron to EN-JS1030 (GGG-40) Disc : Ductile iron to EN-JS1030 (GGG-40, fully coated with EPDM rubber (portable water certified ) Hinge Pin / Shaft:-Stainless Steel [AISI431] Cover Screws Nuts:-Stainless Steel [AISI304] Plug:-Brass Surface Protection:-Epoxy powder coating, min.-250 microns, color: RAL 5005 signal blue (potable water certified) |
| 31 | Supplying erecting testing and commissioning DI/D/F non- rising spindle soft seated glandless gate valves of size 200 mm dia PN 1.6 with body and bonnet cast iron of grade GGG-40 , wedge with fully encapsulated EPDM rubber ( approved for drinking water ) and seals of NBR . The valves should be with replaceble stem nut and replacable sliding shoes , valve stems shall be of single piece thread rolled type valve , shall have 3 ''O '' rings of NBR for stem sealing. Gate valve shall be compatible for buried application without valve chamber. face to face diemensions as per BS 5163-89 / IS -14846 -PD / EN 558 F4 and flange connections as per EN 1092-2/IS 1538 , maximum valve operting torque should be at least 40 % less than the torque as stated in standard EN 1074 . Electrostatic epoxy power / liquid caoting ( EP-P ) inside & outside colour blue RSL 5005 with minimum caoting thickness of 250 microns . The EPDM rubber & epoxy caoting should be potable water certified etc complete. |
| 32 | \\"Providing, erecting, electric valve Actuator for non rising spindle type Sluice valve of PN 1 & PN 1.6 rating totally enclosed weather proof and dustproof construction with IP 67 Protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled spurm or quarter turn gear box , manual hand wheel for emergency which will be automatically dis-engage on rotation power to motor and with 10 watt single phase space heater and continues local mechanical position indicator and individually replaceable counter gear assembly and with two torque switch dial and with TEFC squirrel cage induction motor. (Rate as per excluding GST\\" |
| 33 | \\"Fabrication of structure with for indirect mounting arrangement with suitable length shaft, universal coupling, stool valve positioning concreting of fabricated structure grouting with anchor fastener etc complete. . (Rate as per excluding GST)\\" |
| 34 | \\"Supplying erecting electrical control panel with all actuator motor control system with all indication suitable for 5 actuators ( Rate as per Excluding GST)\\" |
| 35 | \\"Copper conductor PVC as insulated, armoured control cable 2.5 sq mm copper conductor PVC insulated, armoured control cable 12 core 2.5 sq mm \\" |
| 36 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 37 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 38 | Supplying, installing and testing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all accessories of copper materials & recording the results as per specification no. EA-EP |
| 39 | Supply of 400 mm dia full bore electromagnetic flowmeter including all accessories etc complete. |
| 40 | Providing and supplying at dept store work site 400 mm dia MS dismantling joints suitable to various sizes of sluice valves butterfly valves etc with two Ranged type, welded to MS pipes made of MS plates of required thickness, bar stock materials with neoprene one piece 'V' gland ring flanged drilled as per IS:1538, studs of electro-galvanised, and Joints palnted with light grey enamel paint, with necessary machining including hydraulic testing of 18 kg/cm2. The cost includes all taxes, duties etc with transportation to departmental stores except octrol charges. (Rates excluding GST) |
| 41 | \\"Charges of Volumetric Testing and Calibration of 400 mm dia full bore electromagnetic at Manufacture shop and CWPRS Pune\\" |
| 42 | \\"Charges for installation at work for 400 mm dia electromagnetic flow meter Including all accessories and charges for tail peace expander with required hardware etc. complete as per work site condition and including labor, material machinery etc for preparation of M.S.Pipe Fabrication and required excavation including transportation charges\\" |
| 43 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 44 | Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. |
| 45 | Supplying & erecting inline D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire, D.P. Structure shall be erected in c.c. foundation complete |
| 46 | Supplying & erecting inline D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 300 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 47 | Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 100 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40? by thermometer in oil and 45? by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) , with standard accessories complete with test certificate with losses below 475 Watts at 50% load, 1650 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. |
| 48 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50 ? by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. |
| 49 | Providing structural steel work in rolled sections like joists, channels, angles, tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc. and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete. (Bd-C-2/275) |
| 50 | Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \\"C\\" class G.I. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. |
| 51 | Supplying and erecting anti climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. |
| 52 | Supplying and erecting fencing of section having size at least 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete with provided earthing as per specification no. SS-AS/FSG |
| 53 | Supplying and erecting double leaf hinged door each 1500 mm in width x 2450 mm in height using B class GI pipe, hinges and angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation and painted complete as per specification no SS-AS/DLD |
| 54 | Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC |
| 55 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 56 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT |
| 57 | Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE |
| 58 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 59 | Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI |
| 60 | Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN |
| 61 | Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA |
| 62 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6mm., straining screws, G.l. stay wire 7/10 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 63 | Making Cement concrete foundation including excavation (60 x 60)cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45cm x 45cm x 45cm/ 45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (for above 9m poles) |
| 64 | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). |
| 65 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 66 | Supply, installing, and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity (min. 125kg) complete, and recording the results specification no. EA-MF |
| 67 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 68 | Supplying , erecting DTC metering with box & single core cables etc complete as per MSEDCL specifications complete |
| 69 | Supplying , erecting danger board etc complete as per MSEDCL specifications complete |
| 70 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 71 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 72 | Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 73 | Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WG-PW/CW |
| 74 | Supplying and erecting HMS PVC conduit 32mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 75 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25mm with accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 76 | Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40mm with accessories on wall/ceiling as per specification no. WG-MA/CON. |
| 77 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 78 | Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 79 | Supplying & erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW |
| 80 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete. |
| 81 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 82 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module complete. |
| 83 | Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 84 | Supplying, erecting & marking DP MCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 85 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 86 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 8 ways (8 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as per specification no. SW-MCBDB |
| 87 | Supplying and erecting LED square / circular Max. 25 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 88 | Supplying & erecting ready to use Retrofit T8 LED, 18 / 20 watt tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary as per specification No. FG-LP/RET. |
| 89 | Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF. |
| 90 | Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overheat protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation. |
| 91 | Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification No. APWCR/ WC |
| 92 | Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) |
| 93 | Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 94 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT |
| 95 | Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole). |
| 96 | Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC. |
| 97 | Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. |
| 98 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 99 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 100 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 101 | Supplying & erecting three phase, 415V, street light control panel upto the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation as per specification SW-STCP. |
| 102 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 103 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail