| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level), complete all as specified and directed. |
| 2 | M & L for plain cement concrete 1:4:8 Type D-2, using 40mm graded crushed stone aggregate, 75mm thick, as in sub base over rammed earth, complete all as specified and as directed. |
| 3 | M&L for rubber moulded Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 50mm thick sand cushioning, complete all as specified and as directed. |
| 4 | M&L for rubber moulded Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment laid over and including 50mm thick sand cushioning complete all as specified and as directed. |
| 5 | M&L for rubber moulded chequered cement concrete tiles 30cmx30cmx25mm thick with grey cement and pigments over 20mm thick screed bed or bedding layer in cement mortor (1:6) set , jointed and pointed in neat cement slurry, complete all as specified and directed. |
| 6 | M&L for plain cement concrete 1:2:4, type B1, using 20mm graded crushed stone aggregate, as in copings and the likes including necessary form work, complete all as specified and directed. |
| 7 | Material and labour for removal of displaced/ not-in-level interlocking tiles of any size/shape in pathway and replacing the same in proper level over and including 50 mm thick sand cushioning as bed, complete all as specified and directed. |
| 8 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including dismantling of old kerb stones of any type & size, making drainage opening wherever required, complete all as specified and directed. |
| 9 | M&L for Preparing of new surfaces of cornices, pillasters, kerb stone etc. and applying two coats of synthetic enamel paint, complete all as specified and directed. |
| 10 | M&L for Preparing of old treated surfaces of cornices, pillasters, kerb stone by brooming down with steel wire brushing scrapping down smoke soot, moulds Moss and efflorescent salts and treating oily and greasy spots etc and applying two coat of synthetic enamel paint, complete all as specified and directed. |
| 11 | Demolition of stone/ boulders masonery built in cement/ cement lime mortar including all quions, arches, pillars etc but excluding ashler facing ,dressed stone work and pre-cast concrete articles and removing mortar from and cleaning stones/ bricks obtained from masonry of any description, complete all as specified and directed. |
| 12 | M&L for plain cement concrete 1:4:8, type D2, using 40mm graded crushed stone aggregate, as in foudnation filling and mass concrete, complete all as specified and directed. |
| 13 | M&L for walling of random rubble , uncoursed well bonded, bedded and solidly hearted built in CM (1:4) complete all as specified and directed. |
| 14 | M&L for walling of random rubble , uncoursed well bonded, bedded and solidly hearted built in CM (1:4) but except stone, complete all as specified and directed. |
| 15 | M&L for plain cement concrete 1:3:6, type C1, using 20mm graded crushed stone aggregate, as in bond stone set in CM (1:4), complete all as specified and directed. |
| 16 | Extra over stone walling for hammer dressing to face of stone and dressing of face beds and joints, as specified of random rubble walling uncoursed or brought upto course with maximum depressionon face from straight edge held against the dressed surface n exc 20mm on granite or trap stone, complete all as specified and directed. |
| 17 | M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto course in CM 1:3, complete all as specified and directed. |
| 18 | S & F PVC (SWR) conduit pipes 100mm dia in any length with rubble ring joints laid in trenches or in floor or as in weep holes, complete all as specified and directed. |
| 19 | M&L for boulder filling dry, hande packed tightly, as in back fliing of stone masonry, complete all as specified and directed. |
| 20 | M&L for wrought Second class hard-wood in unframed work including dismantling timber scantlings any description and in any position complete , complete all as specified and directed. |
| 21 | S&F 35x10mm laths (fixed straight or diagonally) of 2nd class soft wood clean sawn two way trellies work with 50mm spaces in clear, including 75mmx50mm fillet (notched to take ends of leths) all around and fixed firmly with fastenings including Dismantling of trellis work (jafri), complete all as specified and directed. |
| 22 | M&L for preparation of new surfaces of wooden or wooden based articles of any description, exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 23 | M & L for Framed brackets of angles or tees with web and flanges, tubular pipes cut to shape,drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., conforming to Fe.290.Gde-E-165 incl Dismantling wrought iron or mild steel work of any description, complete all as specified and directed. |
| 24 | S&F in repair 1.5-2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugated side lap fixed with screws and washers including dismantling of old existing sheets, complete all as specified and directed. |
| 25 | S&F in repair 1.5-2mm thick fibre glass reinforced translucent plane sheeting with patterns / designs as directed and 100mm side lap fixed with screws and washers including dismantling of old existing sheets, complete all as specified and directed. |
| 26 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer, complete all as specified and directed. |
| 27 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out concrete embedded portion and making good disturbed ground surfaces, complete all as specified and directed. |
| 28 | Excavating in post holes each n.exc 0.5 cum getting out and removing surplus soil to a distance n.exc 50 m and making good surface complete. |
| 29 | M & L for plain cement concrete 1:3:6 type C-2 , using 40 mm graded crushed stone aggregate, as in foundation for post/strut etc. complete all as specified and directed. |
| 30 | M&L for MS work conforming to Fe-410-0 of Fe-310-0 Grade for fencing posts and struts in fencing including cutting bending top to shape as directed drilling holes matching for barbed wire, including fillet on back side of fencing post and all necessary drilling work, complete all as specified and directed. |
| 31 | Dismantling fencing wire/ mesh of any description, complete all as specified and directed. |
| 32 | Supply only chain link MS galvanisd fencing, any size or type, complete all as specified and directed. Note :Actual weight of the fencing shall be ascertained by board of officers to be convened by GE. |
| 33 | Fixing only Chain link fencing including line wires, any mesh, size & type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed. |
| 34 | M & L for flat iron of size as directed as in fixing clamps or support to chain link fencing, stifners etc fixed with nut and bolts including making necessry holes, complete all as specified and directed. |
| 35 | M & L for Mild steel round bars 8mm dia horizontally woven in chain link fencing. complete all as specified and directed. |
| 36 | Mild steel screw bolts (machine made) 5 ot 10mm dia of shank with hexagonal or square heads at one end and screwed the othere, each screw end to be fitted with washers and one hexagonal or square nut exc 5cm but n exc 10cm long, complete all as specified and directed. |
| 37 | S & F Punched tape concertina coil fencing with concertina coil of 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, spring core wire (2.5 mm thick) of high tensile strength of 165kg/sq. mm having weight 43.478 gm/metre incl securing or tying at crossings with provision of galvanised mild steel wires, staples or pins etc incl taking out old worn out concertina in any position and in any height, complete all as specified and directed |
| 38 | M&L for plain cement concrete 1:3:6 type C-2, using 40 mm graded crushed stone aggregate, as in surface channel and drains complete all as specified and directed. |
| 39 | M&L for extra for forming fair finishing drain or channel 30cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stopped ends etc., complete all as specified and directed |
| 40 | Demolition of brick work , built in cement mortar or cement lime mortar including all quions, arches, pillars, etc including demolition of precast rcc articles and disposal of debris out of MoD land, complete all as specified and directed. |
| 41 | M&L for brickwork with old sized subclass 'B' bricks straight or curved on plan exc 6m mean radius and built in CM 1:6, complete all as specified and directed. |
| 42 | Description all as per serial item No 41 here-in-before, but except bricks, complete all as specified and directed. Note: Old burnt clay bricks retrieved from demolition shall be used. |
| 43 | Taking down cement of cement lime plaster of any description on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed. |
| 44 | M & L for rendering 15mm thick in CM 1:4 on stone masonry / brick surface finished even and smooth without using extra cement with liquid water proofing admixture, complete all as specified and as directed. |
| 45 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a chalk white of primer, complete all as specified and directed. |
| 46 | Dismantling of fencing wire of any type, complete all as specified and directed. |
| 47 | S&F galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails staining bolts including, securing or tying at crossings with and provn of galvinised mild steel wire, staples or steel pins etc as directed (each line wire to be measured), complete all as specified and directed |
| 48 | Fixing only galvanized to strands, steel brabed wire 2.24mm dia barbed with 2mm dia barbes at 75mm spacings and straining and fixing to any type of standard rails including securing or taying at croses with and provision of galvanized mild steel wire, (each line wire to be measured) complete all as specified and directed. |
| 49 | Notes :-An amount of Rs.76,878.50 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |