| 1 | Labour only for attending day to day complaints of external water supply and for checking/repair / replacement of existing water supply items for continous fresh/ hot water supply or detection of nature of defect including carring out minor repairs, as required to make the items functional, finding of defects, taking down/up of Gl Pipe and fittings such as valves, unions, sockets, elbows and tees of different sizes etc and refixing/replacement of items mentioned, tightning the loose joints complete all as specified & as directed by Engineer-in -Charge for 21 Wing area round the clock as and when required.NOTE: (a) Items replaced shall be measured seprately. (b) All the necessary T&P, required for repair shall be provided by the contractor. (c) Required Complain slip, and complain register, required shall be provided by the contractor. (d) Necessary transportation to the employees shall be provided by the contractor.(e) Contractor shall provide at least one FGM/ Pipe fitter with one helper to attend the complaint on each day and report to concerned JE daily. JE will record attendence in register daily basis in working days. Penality for absent of labour shall be imposed on contractor @Rs. 750 per day. |
| 2 | Excavation, in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr in depth for laying GI pipe line in hard / dense soil and getting out complete all as specified. |
| 3 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick all as specified. |
| 4 | Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified. |
| 5 | Taking up or down steel tubing with connection from trenches, ceilings, floors walls etc including cleaning for refixing or removing from site complete with all fittings ( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc) all as specified of following sizes: |
| 6 | 15mm dia |
| 7 | 20mm dia |
| 8 | 25mm dia |
| 9 | 40mm dia |
| 10 | 50mm dia |
| 11 | 80 mm dia |
| 12 | Refixing old steel water tubing medium grade galvanised with all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc) all as specified of following sizes:-Note serviceable pipe obtained from srl item No 05 to be re used. |
| 13 | 15mm dia |
| 14 | 20mm dia |
| 15 | 25mm dia |
| 16 | 40mm dia |
| 17 | 50mm dia |
| 18 | 80 mm dia |
| 19 | S&F in Replacement of Steel water tubing medium grade galvanised ( ISI marked) with all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc) all as specified of following sizes:- |
| 20 | 15mm dia |
| 21 | 20mm dia |
| 22 | 25mm dia |
| 23 | 40mm dia |
| 24 | 50mm dia |
| 25 | 80 mm dia |
| 26 | S&F in Replacement of bronze, globe or gate valves, 15 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge. |
| 27 | All as per item no 7 but of size 20mm |
| 28 | All as per item no 7 but of size 25mm dia |
| 29 | All as per item no 7 but of size40mm dia |
| 30 | All as per item no 7 but of size 50 mm dia |
| 31 | S&F in Replacement for 15 mm dia ball brass valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engr-in-Charge. |
| 32 | All as per item no12 but of size 20 mm |
| 33 | All as per item no12 but of size 25 mm dia |
| 34 | S&F in Replacement of cast iron sluice valve ISI marked 50 mm dia class PN 1.6 flanged with gun metal spindle including all fittings such as nuts , bolts, washers tec with iron wheel confirming to IS: 780/14846 complete in all respect all as specified. |
| 35 | All as per item no15 but of size 80 mm dia |
| 36 | All as per item no15 but of size 100 mm dia |
| 37 | S&F in Replacement GI fittings heavy duty ISI marked including necessary cutting, screwing and making threads complete all as required at site and as directed by Engg- in- charge. |
| 38 | GI Elbow15mm |
| 39 | GI Elbow 20mm |
| 40 | GI Elbow 25mm |
| 41 | GI Elbow 40mm |
| 42 | GI Elbow 50mm |
| 43 | GI Elbow 80mm |
| 44 | GI Socket 15mm |
| 45 | GI Socket 20mm |
| 46 | GI Socket 25mm |
| 47 | GI Socket 40mm |
| 48 | GI Socket 50mm |
| 49 | GI Socket 80mm |
| 50 | GI Union 15mm |
| 51 | GI Union 20mm |
| 52 | GI Union 25mm |
| 53 | GI Union 40mm |
| 54 | GI Union 50mm |
| 55 | GI Union 80mm |
| 56 | GI Reducer Socket 20 x 15mm |
| 57 | GI Reducer Socket 25 x 20mm |
| 58 | GI Reducer Socket 25 x 15mm |
| 59 | GI Reducer Socket 40 x 25mm |
| 60 | GI Reducer Socket 40 x 20mm |
| 61 | GI Reducer Socket 50 x 40mm |
| 62 | GI Reducer Socket 50 x 25mm |
| 63 | GI Elbow reducer 20 x 15mm |
| 64 | GI Elbow reducer 25 x 20mm |
| 65 | GI Elbow reducer 25 x 15mm |
| 66 | GI Elbow reducer 40 x 25mm |
| 67 | GI Elbow reducer 40 x 20mm |
| 68 | GI Elbow reducer 50 x 40mm |
| 69 | GI Elbow reducer 50 x 25mm |
| 70 | GI Nipple 15 x100mm |
| 71 | GI Nipple 20 x100mm |
| 72 | GI Nipple 25 x 100mm |
| 73 | GI Nipple 40 x 100mm |
| 74 | GI Nipple 50 x 100mm |
| 75 | GI Tee 15 x 15 mm |
| 76 | GI Tee 20 x 20 mm |
| 77 | GI Tee 20 x 15 mm |
| 78 | GI Tee 25 x 25 mm |
| 79 | GI Tee 25 x 20 mm |
| 80 | GI Tee 25 x 15 mm |
| 81 | GI Tee 40 x 40 mm |
| 82 | GI Tee 40 x 25 mm |
| 83 | GI Tee 40 x 20 mm |
| 84 | GI Tee 50 x 50 mm |
| 85 | GI Tee 50 x 40 mm |
| 86 | GI Tee 50 x 25 mm Please Enable Macros to View BoQ information |
| 87 | GI Tee 50 x 25 mm Please Enable Macros to View BoQ information |