| 1 | CIVIL WORK |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 3 | Excavation for foundation in earth, soils of all types, sand, gravel and soft murum ,including removing the excavated material upto adistance of 50m beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Manual Means |
| 4 | Excavation for foundation in hard murum including removing the excavated material upto adistance of 50metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming,wateringincludingshoringandstruttingetc.complete.(Liftfrom1.5to3.0m) |
| 5 | Providing soling using 80 mm size trap metal in 15cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. |
| 6 | Filling in plinth and floors with approved excavated material in 15cm. To 20cm. Layers including watering and compacting etc. complete. |
| 7 | Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15cm to 20cm including watering and compaction etc. complete. |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M-10 of trap / granite/quartzite/gneiss metal for gneiss meta for foundation and bedding including bailing out water, Steel centering , formwork, laying/ pumping, compacting, roughening them if special finish ist obe provided,finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Panmixer)etc.complete. With fine aggregate (Crushed sand VSI Grade) |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete in M 20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. work in foundation slikeraft, stripfoundations, grillage and footings of R.C.C.columns and steel stanchions etc., including bailing out water, Steel centering form work, laying/ pumping cover blocks, compaction and curing rough eningthe surface if specialfinishis to be provided (Excluding reinforcement and structural steel)etc.complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Typemixer/ concrete Batchmixplant (Panmixer) etc.complete. With fine aggregate (Crushed sand VSI Grade) |
| 10 | Providing and laying Castinsitu/ Ready Mix cement concrete M-20 oftrap/ granite/ quartzite/ gneiss metal for R.C.C. column sasper detailed design sand drawing or as directed including steel centering,formwork,cover blocks, laying/ pumping, compaction finishing the formed surfaces with cementmortar1:3 of sufficient minimum thickness to give a smooth and even surface orroughening if special finish istobe provided and curingetc. complete.(Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Typemixer/ concrete Batch mixplant (Panmixer) etc.complete.With fine aggregate (Crushed sand VSI Grade) |
| 11 | Providing and laying Cast insitu/ Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneissmetal for R.C.C. beam sand lintelsasper detailed design sand drawing soras directed including steel centering, formwork, coverblocks, laying/ pumping,compactionand roughening the surface if special finish is to be provided andcuringetc.complete.(Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Typemixer/ concrete Batch mixplant (Panmixer) etc.complete.With fine aggregate (Crushed sand VSI Grade) |
| 12 | Providing and laying Cast insitu/ Ready Mix cement concrete M-15 oftrap/ granite/ quartzite/ gneiss metal for coping top linthorparapet, moulded orchamfered as per-drawing or as directed including steel centering, plywood/ steel form work compacting, roughening them if special finish is to be provided, finishing un-even and honey combed surface and curingetc. complete. The Cement Mortar 1:3 plasteris considered forrendering un-even and honey combed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.(Wood encentering will not be allowed.)With fine aggregate (Crushed sand VSI Grade) |
| 13 | Providing and laying Cast-insitu/ Ready Mix cement concrete in M-20 oftrap/ quartzite/ granite/ gneiss metal for R.C.C. Waistslab, and step sofstair cases as per detailed design and drawing so rasdirected including steel centering, formwork, steel props, laying/ pumping, compaction, finishing un-even and honey combed surface with C.M.1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curingetc.complete.(Excluding einforcement, including cover block). (Newlyl aid concrete shall be covered by gunnybag, plastic, tarpaulinetc.)with fully automatic microprocessor based PLC with SCAD Aenabled reversible Drum Typemixer/ concrete Batch mixplant (Panmixer) etc.complete.With fine aggregate (Crushed sand VSI Grade) |
| 14 | Providing and laying Castinsitu/ Ready Mix-cement concrete M-20 oftrap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, coverblocks, laying/ pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Typemixer/ concrete Batch mixplant (Panmixer) etc.complete.With fine aggregate (Crushed sand VSI Grade) |
| 15 | Providing and laying insitu cement concrete M2 0with tre mix treatment for 100mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. |
| 16 | Providing and fixing in position TMT-FE-500 barre inforcemen to fvarious diameters for R.C.C. pilecaps, footings ,foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintel spardis, copings, fins, arches etc. as per detailed designs ,drawings and schedules. including cutting, bending, hooking the bars, binding with wire-sortack welding and supporting as required complete |
| 17 | Providing second class Burnt Brick masonry with conventional/ I.S. type brick since mentmortar 1:6 in plinthas backing in composite masonry including bailing out water manually, strikingjoints, raking out joints and watering etc Complete. |
| 18 | ProvidingsecondclassBurntBrickmasonrywithconventional/I.S.typebricksincementmortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,watering and scaffolding etc. Complete |
| 19 | Providing second class Burnt Brick masonry with conventional/ I.S. type brick since mentmortar 1:4 in half-brick thick wall including mildsteell on gitudinal reinforcement of 2 bars of 6mm diameter/ 2 hoopiron strips 25mmX1.6mm place date very third course, properly bent and bond edatends scaffolding, racking out joint sand watering etc. complete. |
| 20 | Providing internal cement plaster 6mm thick in a single coat incement mortar 1:4 with outneeru finish to concrete surface in all positions including scaffolding and curing etc. complete |
| 21 | Providing internal cement plaster 12mm thick in single coatincement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 22 | Providing internal cement plaster 20mm thickin Single coat since mentmortar 1:5 without neeru finish, toconcrete, brick surface, in all positions including scaffolding and curingetc. complete |
| 23 | Providings and faced plaster externally in cement mortar using approved screeneds and, in all positions including base coat of 15mm thick incement mortar 1:4 using waterproofing compound at 1Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive thes and face dtreatment 6to8mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 24 | Provid ingand fixing chicken mesh of 22 gauge, withabout 30cm. Width at the junction of R.C.C members and brickwork, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B. masonry and or tying by binding wire etc. complete. |
| 25 | Providing and applying Two coats of wallcare Putty on plastered surface and Ceiling and Wall stop repare surface even and smooth of approved make, etc complete. |
| 26 | Providing and applying washable oil-bound distemper of approved colour and shade toold and new surfaces in one coat including scaffolding, preparing the surfaces.(excluding the primer coat.)etc. complete. |
| 27 | Providing and applying three coats of waterproof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc.complete. |
| 28 | Providing and applying white-washing two coats on old/ new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. |
| 29 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of 3.15mm thickness reinforced with 35x35x5mm angle section fitted with sliding bolt sand handles for both sides, deep M.S. channel section of depth and thickness not less than 65mm and 3.15mm respectively with hold fast arrangements, M.S. Bracket plate 300x300x3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32mm diameter, hood cover of M.S. sheet not less than 0.9mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast ironor mild steel and one coat of redlead primeretc. complete. (I.S.62481979) (Without mechanical gear) |
| 30 | Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hot dipzinc coating including fabricating glazing with plain/ obscured glass panes 5mm thick and approved type and quality and iron oxidized fixtures and fastening oil paint 2 coats etc. complete. |
| 31 | Providing and fixing 90cmx60cm Marble plate engraving 10cm. Height letter, figures including painting the lefters/ figures with approved colour and shade complete |
| 32 | Providing and fixing mild steel grill work for windows,ventilators etc. 20Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. |
| 33 | Providing and fixing frame with/ without ventilator of size as specified with Country cutteak wood for doors and windows including chamfering, rounding, rebating, iron hold fast of size300mmx40mmx5mm with oil painting, etc. complete |
| 34 | Providing and fixing M40 grade thick vibrated pullcastor similarty pe-concrete frame with chamfer conformingtoI.S.65241983 having 6mm dia. bars 3Nos .And stirrups@250mmc /cand fixing in wall with 6Nos of hold fast of 12mm diabars 500mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . |
| 35 | Providing and fixing solidcore flushdoor shutter commercial in single leaf 32mm thick without ventilator commercial type of exterior grade as per detailed drawings with wroughtiron hold fast,stainless steel fixture sand fastening sandhand leson both sides and finishing withoil painting 3 coats complete. |
| 36 | Providing, laying and fixing P.V.C. pipe of 110mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky oras directed etc.complete. |
| 37 | Providing and fixing inposition. (asperI.S.1868/1982)Aluminium sliding window of two tracks with rectangular pipe having over all dimension?63.50 x 3810 x 1.02 mm at weight 0.547 Kilogram/ One Running Metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/ One Running Metre. Top and side track section 61.85 x31.75 x1.30mm at weight 0.659Kilogram /One RunningMetre. The shutter should be of bearing bottom 40x 18x 1.25 mm at weight 0.417Kilogram/ One Running Metre. Inter locking section 40x18x1.10 mm at weight 0.469 Kilogram/ One RunningMetre. And handle section 40x18x1.25mm at weight 0.417Kilogram /One Running Metre. and top section 40x 18x 1.25mm at weight 0.417 Kilogram/ Running metre. As per detailed drawings and as directed by Engineer incharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing innylon casting and self locking catch fitted invertical section of shutter including 5mm thick plainglass with all required screws and nutsetc,complete.Withpowder coating without box |
| 38 | Providingandfixing900mmhighS.S.304GradeStainlesssteelrailingwith40mmdiameterand1.5mmthickattop,40mmdiameterand1.5mmthickverticalsupportsspacedat1.5mcentertocenterand8mmthicktoughenedglassincludingfabricating,fixtures,errecting,necessarywelding,grinding,finishing,buffingtostainlesssteelpipeetc. complete |
| 39 | Providing and fixing single or double leaf panelled door shutter excluding frame with glazed openable fanlight shutter 35mm thick as per detailed drawing consisting panelled vertical styles100mm x35mm and lock and bottom rail 200mm x35mm and panels 12mm thick both side commercial ply faced particle board including stainless steel fixtures and fastening and T.W. beading at junction soft panel inserts and as instructed by the Engineer incharge including 3coats of oil painting etc. complete. |
| 40 | Providing and fixing in position powder coated aluminium louvered windows/ ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80x38mmx1.22mm boxtype, 5mm thicksheet glass louvers, of approved quality etc. complete. |
| 41 | Providing structural steel work intrusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawing soras directed including cutting, fabricating, hoisting, erecting fixinging position, Making riveted/ bolted/ welded connection and one coat of anti-corrosive paint and overit 2coats of oil painting approved quality and shade etc. complete. |
| 42 | Providing and fixing colour coated Zinc alume(R)AZ150 (min 150gms/ sq.mt. total one achside)profiled sheets forroofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness(BMT) (0.5mmTCT),Hi-strength steel with min.550M Payield strength, metallic hot dipcoated with Aluminium-Zincalloy (55% aluminium 43.4%zinc1.6% silicon) with COLORBOND(R)steel quality super durable polyester paintcoat (within organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25um exterior coat on top surface and nominal 10um reverse coat on back surface. Profile sheet shall have nom.950-1050mm effective cover width and nominal 25-30mm deep ribs with subtle square fluting in the five panat nominal 180-250 mm center-to-center.Theendribshallbedesignedforanti-capillarygroove.andreturnleg.Thefeedmaterialshouldhavecoilmanufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin.fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc.complete.(weight of profile 4.52 Kilogram/ One Square Metre) |
| 43 | Providing and fixing plain zinc sheeting of 0.80mm thick (22B.W.G.)ove rthe ridge hiporvalley togal vanizediron sheet roofing including all faste ning and boltgal vanised iron screws and bolts, lead and bitumen washers etc.complete.(Weight of 6.8 Kilogram/ sq.m.). |
| 44 | Providing and laying concrete pipes of I.S.NP. Class of 300mm diameter in properline, level and slope including necessary collars, excavation, laying, fixing with collars incement mortar 1:1 and refilling the trench complete. |
| 45 | Providing pre constructional antitermite treatment asper I.S.6313(Part-II)treatment byt reating the back filling immediate contact with foundation at the rate of 5litres of emulsion concentrate of1.0 percent of clorophyrifosper One Square Metre of vertical surface area covering10 years guarantee on bond paper. |
| 46 | Providing expansion jointsin R.C.C. framed structure (exteriorColumns)with plain pre-moulded filler 25mm thick and 3mm thick alluminium plate, hold fast, fixing T.W. batten soninternal face, finishing etc.complete as directed. |
| 47 | Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18mm dia. mild steel bar for water tank including fixingitin(1:2:4)M-15 cement concrete block 60cm x30cm x30cm and painting the ladder complete. (AntiCorossive Paint) |
| 48 | Finishing the Terrace Slab Integrally Mixed With Water Proofing compound in CM 1:3 With 12mm thick Layer Including Curing finishing using water proofing compound as Approved by Engineer incharge At The Rate Of 1Kg Per Bag of cementetc Comp (NoteItem not to be used as Water proofing Treatment Over terrace)Rate As Per Qaurirandam Of SEPWD Amravati Letter No 3985 Date 6/10/2020 |
| 49 | Providing & Fixing matt finish stainless steel lettering of various heights as directed by Engineer In-Charge including material, labour, cleaning etc. complete.As directed by Engineer In Charge, upto 30cm height |
| 50 | ELECTRIFICATION |
| 51 | Supplying, erecting & terminating FRXLPE insulated, galvanized steel formed wire armored (strip)cable 1100V, 3core 6sq.mm. aluminium conductor complete erected with glands & lugs, onwall/ trusses/ poleorlaid in provided trench/ pipe as per specification no. CB-LT/AL 7-1-9 |
| 52 | Making trench in soft soil having 0.75m depth and minimum 0.3m width for laying provided cables upto voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 16-1-1 |
| 53 | Making trench in Hardmurum/ Tarroad having 0.75m depth and minimum 0.3mtr width as per Isforlaying provided cables upto voltage level 1.1Kv cable complete as per specification No.CW-EXN-CTR 7-2-5 |
| 54 | Supplying and erecting mains with 3x2.5sq.mm FRLS Hcopper PVC insulated wire laidin provided conduit/ trunking/ insidepole/ Busbarsorany other places as per specification No:WG-MA/BW 5-12-1 |
| 55 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with10A, 2pin plug & earth socket and 10A, 3pin plug top with 10 As ingle pole MC Bhavingrated short-circuit breaking capacity(Icn) 10kA complete erected on angle iron / GI frame. 5-4-10 |
| 56 | Point wiring forlight/ fan/ bellin 20mm FRLS grade HMSPVC conduit with1.5sq. mm(2+1E)FRLSH grade copper wire with flush types witch and required accessories as per specification No:WG-PW/SW1-7-3 |
| 57 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitablefor B-22 /E-27 base. 2-8-11 |
| 58 | Supplying and erecting integrated LED street lightfitting18 to 22 WIP65& IK08 class having single piece pressure die-cast aluminum housing, having system lumens out put of Min.1800 Lumens, min. efficacy of 100 lumen/ W,CRI>70, CCT upto 6500K, THD<10% ,p.f.>0.95 ,operating range of 140-270V, inbuilt surge protection of 10kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FGODF/FLS2. 2-4-1 |
| 59 | Supplying and erecting Street light bracket made from 40mm. Dia 'B'class G.I.Pipe, 0.6m. In length along with pole cap of 300mm length and 80mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 2-7-2 |
| 60 | Providing earthing with galvanized iron earth plate size 60x60x0.6cm complete with all materials, testing & recording there sults as per specification no. EA-EP 9-1-1 |
| 61 | Providing pipe type earthing with 40mm. dia. G.I. pipe or 20mm dia. G.I. Rod complete with all material stesting and recording there sultsas per specification no. EA-EP 9-1-4 |
| 62 | Supplying, erecting & marking DPMCB 6A to 32А, С-series with rated short-circuit breaking capacity(Icn) 10k Ain provided distribution board as per specification no. SW-SWR/MCB 5-3-6 |
| 63 | Supplying, erecting & marking SPMCB 6A to 32А, В-series with rated short-circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 5-3-3 |
| 64 | Supplying and erecting GI sheet 1.6mm (16SWG)having zinc coating of 350microns with galvanization process compliance to IS2629:1985 to be used for fabrication of boxes panel boards etc.including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. 6-1-6 |
| 65 | Supplying and erecting marine(Waterproof) plywood 18/19mm thick fixed to walloron provided panel board with necessary materials such as screws, wall fasteners, supports, nutboltsetc. Complete with compliance to IS 720:2010 6-1-14 |
| 66 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3pole/ 4pole MCCB asincomer & outgoing SPMCB (12poles)or TPMCB of 4ways (12poles), withdoor, 1.2mm thickness, surface/ flush mounted, oniron/ Glframe (vertical bus bar type) as per specification no. SW-SWR/ MCBDB 1 5-4-15 |
| 67 | Supplying & erecting G.I. pipe 'A' class 25mm dia. Erected for enclosing XLPE armored cable on wall/ pole as per specification no.CB-CE 7-6-1 |
| 68 | Supplying & erecting G.I. pipe 'A' class 40mm dia. Erected for enclosing XLPE armored cable on wall/ pole as per specification no.CB-CE 7-6-2 |
| 69 | Supplying and aying (including excavation of suitable width & depth upto 90cm) 75mm outside dia. Double wall corrugated pipes (DWC)of HDPE for enclosing cable below ground/ road surface, to required depth complete. 7-6-10 |
| 70 | Supplying & erecting 18 guage M.S. Box powder coated (4\\"x4\\") 3way for mains connection. MR |
| 71 | Supplying & erecting single compression type brass cable glands for 3 to 4 core 6sqmm/ 2 to 4 core 10sqmm for XLPE armored cable as per specification No. CB-GL 7-7-2 |
| 72 | Supplying and erecting Ceiling rose/ Battenholder/ Slanting holder/ hanging cords witch/ hanging bell push/ pendant holder bakelite based A. erected on filled poly propylene board or polished double wooden block/ PVC junction box. 1-5-7 |
| 73 | Pointwiringforindependentplugin20mmmetalconduitwith1.5sq.mm(2+1E)FRLSHgradecopperwire,flushtypeswitch,earthingand required accessories as per specification No: WG-PW/SW 1-7-2 |
| 74 | Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW 1-7-26 |
| 75 | Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laidin provided conduit/ trunking/ insidepole/ Busbarsorany other places. as per specification No: WG-MA/BW 1-3-2 |
| 76 | Supplying and erecting mains with 2x4sq.mm FRLSH copper PVC insulated wire laidin provided conduit/ trunking/ insidepole/ Busbarsorany other places. as per specification No: WG-MA/BW 1-3-3 |
| 77 | Supplying and erecting modular type D.P.switch 32A within dicator, dulyerected on provided plate and box with wiring connections complete. 1-6-8 |
| 78 | Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc.in provided distribution board. 5-3-14 |
| 79 | Supplying&erecting3W,230VintegraltypeLEDLampsuitableforB-22 / E-27 base. 2-8-9 |
| 80 | Supplying and erecting IP65 and IK08 rated UV shielded poly carbonate water proof and dust proof industrial grade LED fitting (4feet)max. 36W with high transitivity diffuser with system lumens output of min. 4300 lumens, min. efficacy of 120 lumen/ W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple <5%, THD<10%, p.f.>0.95, operating range of 120-270V, surge protection o f4kV, Life class of 50,000Hrs. at L70B50, IP20 rated, including driver with autocutoff & autorestart feature at 325V with end capson PVC lock/ wooden board with 3 years warranty. 2-2-1 |
| 81 | Supplying and erecting regular/ standard model ceiling fan of 900/ 1050mm. Sweep complete erected in position as per specification no.FG-FN/CF 2-10-2 |
| 82 | Supplying and erecting dingdong/ electronic musical type callbell with heavyduty coil suitable to operate on 230VA.C.supply erectedon olished double wooden block/sun mica block of suitable size. 2-3-13 |
| 83 | Supplying and erecting Street light bracket made from 25mm. Dia 'B'class G.I. Pipe, 0.6m. In length alongwith pole cap of 300mm length and 80mm diaduly welded with provided leads as per specification no. FG-BKT/BPC 2-7-1 |
| 84 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DPMCB/ TPMCB/ FPMCB/ RCCB/ RCBO complete erected on angle iron/GI frame. 5-4-13 |
| 85 | Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board.5-3-18 |
| 86 | ROYALTY CHARGES |
| 87 | OTHER MINERALS / Murum |
| 88 | QUALITY CONTROL & LAB TESTING |
| 89 | Cement: Standard Consistancy Fineness,Specific Gravity,Setting Time ( Initial & Final ), Compressive Strength,Soundness. |
| 90 | Aggregates: Water Absorption, Specific Gravity,Impact Value/Crushing Value. |
| 91 | Sand: i) Fineness Modulus.ii) Silt, Clay Content. |
| 92 | Bricks: Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks). |
| 93 | Concrete: Compressive Strength of C.C. Cube (Set of 3 cubes). M-20 & M-10 1set of 3 cubesfor eachgrade a) Upto 5 cum.-1 Set .b) 6 to 15 cum-2Sets c) 16 to 30 cum-3Sets. d) 31 to 50 cum-4Sets. e) 51 & above-4 Plusone additional sample for each additional 50 cum or part thereof. (Set of at least one sample shall be taken from each shift of work) |
| 94 | Stone/Rubble: Crushing Value/Compressive Strength Water Absorption & Specific Gravity |
| 95 | Compaction Test (Proctor Density) |
| 96 | Steel: 1. Upto 16 mm (Set of 3 Bars) |
| 97 | Steel: 2. Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress, Weight-Per Meter, Bend / Rebend Test, Proof Stress) |
| 98 | Management Strategies and implementation plan (MSIP) to manage the Environmental Social Health and safety (ESHS) risks and ESHS Code of Conduct Please Enable Macros to View BoQ information |