| 1 | Sub Head -I |
| 2 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non-rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : |
| 3 | 150 mm dia |
| 4 | 300 mm dia |
| 5 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required: |
| 6 | 150 mm dia |
| 7 | 300 mm dia |
| 8 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support rame and painting with two or more coats of synthetic enamel paint of required shade complete as required. |
| 9 | 150 mm dia |
| 10 | 300 mm dia (wall thickness 7 mm) |
| 11 | Supplying and Fixing of Onload 4 pole manual changeover switch rating 800 Amp, operated on 415 Volts ,50 Hz with sheet enclosure weather proof side handling operated & fixing by Angle iron, nut & bolts etc. complete etc. as reqd. |
| 12 | Supply installation and testing and commissioning of centrifugal Storm/Sewage mixed flow type pump set having single stage, suction 300 mm dia, delivery 300 mm dia, discharge minimum 18500 liter per minute at minimum head 15 mtr, semi open mixed flow pump, C.I impellers & solid handling capacity gland packed stuffing box complete with not less than 150 HP TEFC 415 V 50 HZ 1486 rpm horizontal electric motor coupled on a fabricated base plate through a set of flexible couplings with 6 Nos AVM pads etc. as required. |
| 13 | 150 HP (18500LPM@ 15 M Head) |
| 14 | Supplying, fixing, testing & commissioning of following manually operated Oil immersed drum type Star Delta Motor Starter with double contact heavy duty and cable entry box, oil tank with oil complete with SS enclosure and operation handle complete etc. as reqd. |
| 15 | 60 HP |
| 16 | 80 HP |
| 17 | 200 HP |
| 18 | Supplying & laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1 in following manners. |
| 19 | 3 x 95 sq. mm (in the existing masonry open duct as required) |
| 20 | 3 x 150 sq. mm (in the existing masonry open duct as required) |
| 21 | 3.5 x 240 sq. mm (in the existing masonry open duct as required) |
| 22 | 3.5 x 400 sq. mm (in the existing masonry open duct as required) |
| 23 | Supplying & laying of one Number Following size. XLPE insulated PVC outer sheathed armoured with galvanized round steel wire or strip cables with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098 / (Pt.-I)/88 with ammendment No. 1 in following manners. |
| 24 | 3 x 95 sq. mm (on wall surface as required.) |
| 25 | 3 x 150 sq. mm (on wall surface as required.) |
| 26 | 3.5 x 240 sq. mm (on wall surface as required.) |
| 27 | 3.5 x 400 sq. mm (on wall surface as required.) |
| 28 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 29 | 3 X 95 sq. mm (38mm) |
| 30 | 3 X 150 sq. mm (50mm) |
| 31 | 3½ X 240 sq. mm (62mm) |
| 32 | 3½ X 400 sq. mm (82mm) |
| 33 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 34 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 35 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm RLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 36 | Group C |
| 37 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 38 | 3 x 4 sq. mm |
| 39 | Supplying & laying of one Number multi core flexible PVC outer sheathed copper conductor suitable for rated voltage of 1.1 KV grade ISI marked in following manners. |
| 40 | 3 x 1.5sq. mm (in the existing masonry open duct / existing pipe /tray as required) |
| 41 | 3 x 4 sq. mm |
| 42 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 43 | 25 mm |
| 44 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But Without MCB/RCCB/Isolator) |
| 45 | 12 way , Double door |
| 46 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 47 | Single door |
| 48 | Double door |
| 49 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 50 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 51 | Supplying and Fixing 400 mm PVC Wall Fan suitable for operation on 230 volt, ±10%, 50 Hz supply to fixed by making necessary arrangements on the wall i/c testing etc as reqd. |
| 52 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 0/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external Connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5-year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 53 | 18- 22 Watt LED Batten light (System lumen efficacy ≥105 <120lm/Watt). LED Powder Coated CRCA Sheet Body (Thickness >0.50 mm) |
| 54 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body With built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 52 DELHI SCHEDULE OF RATES (E&M)-2025 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as er LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all expect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 55 | 70-watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). |
| 56 | Supplying installation, Testing,& commissioning of indoor type cubical LT Panel depth not less than 300 mm, fabricated with 2 mm thick CRCA sheet suitable for 415/ 500 volts 50 Hz A.C. supply with CRCA sheet on bottom for taking load of cable gland necessary individual gland plates for cable gland, cable alley, MS angle iron frame 40mm x 40 mm x 5 mm, locking arrangements as per direction of engineer in charg complete with bus bar chamber having 800 Amp TPN Al busbar duly sleeved and Numbering, i/c supplying and fixing the following mounting inside the panel - interconnections with suitable size Al. bus bar/copper cable for suitable size for following outgoing and incoming MCCB’s, earthing studs, powder coating/ stove enamelled painting after 7 tank treatment process, arrangement with following accessories as reqd. of (not less than 2.24 Sqmtr) Supplying installation, Testing,& commissioning of indoor type cubical LT Panel depth not less than 300 mm, fabricated with 2 mm thick CRCA sheet suitable for 415/ 500 volts 50 Hz A.C. supply with CRCA sheet on bottom for taking load of cable gland necessary individual gland plates for cable gland, cable alley, MS angle iron frame 40mm x 40 mm x 5 mm, locking arrangements as per direction of engineer in charg complete with bus bar chamber having 800 Amp TPN Al busbar duly sleeved and Numbering, i/c supplying and fixing the following mounting inside the panel - interconnections with suitable size Al. bus bar/copper cable for suitable size for following outgoing and incoming MCCB’s, ..................Cont.................. |
| 57 | earthing studs, powder coating/ stove enamelled painting after 7 tank treatment process, arrangement with following accessories as reqd. of (not less than 2.24 Sqmtr) a) Incoming 630 Amp 50 KA 4P MCCB with Thermal Magnetic release with Phase barriers and spreader terminals on incoming and outgoing side with extended rotary handle complete with connections etc. as required-1 Nos. b) Outgoing 250 Amp 36 KA 4P MCCB with Thermal Magnetic release with Phase barriers and spreader terminals on incoming and outgoing side with rotary handle complete with connections etc. as required-6 Nos.c)5-32 Amp DP MCB – 7set. d) Multifunction meter with suitable CT ratio – 7set. e) RYB LED indicator with control accessories- 7 Set |
| 58 | Supply and fixing of special type SS304 wall arrangements by using SS304 L angle and Mesh based customised steel coverage unit to protect 7 Nos high power pump foot valve from city debries collected in U/G sump well including cutting, SS welding, commissioning, testing etc. as required. |
| 59 | Credit for old dismantle materials old dismantled existing 100 HP motor pump set etc. Complete with dismantling of equipments. |
| 60 | Credit for old dismantle materials like Panel, Cables, pipe Valves starter etc. Complete with dismantling of equipments. |
| 61 | Sub Head -II |
| 62 | Supplying & laying of one Number following core PVC/XLPE insulated with PVC outer sheathed armoured Aluminium conductor cable suitable for rated voltage of 1.1 KV grade ISI marked in following manners. |
| 63 | 3 x 4 sq. mm (on wall / existing tray) |
| 64 | Supplying and fixing of following sizes of PVC trunking profile along with accessories fixing on wall surface and making good the same as required. |
| 65 | 50x 50 MM |
| 66 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 67 | Supplying and Fixing 450 mm (18\\") heavy duty industrial Wall mounting Air circulator suitable for operation on 230 volt, ±10%, 50 Hz supply having 1440 RPM, 3 Nos blades and air delivery 150 cubic mtr /min. to be fixed by making necessary arrangements on the wall i/c testing etc as reqd. |
| 68 | Supply of Pendant Circular diffused Industrial Well glass robust and modern lowbay Industrial 35watt LED luminaire with unconventional breakthrough design forilluminating mid and high ceiling of Housing made-up PDC Aluminium with UV Stabilized Injection moulded PC Diffuser to ensure effectively light distribution. Luminaire to have 220-240V AC (Input load type) power supply, Minimum luminaire efficacy >110 lm/W, Minimum lamp life L70B50 ≥50,000hrs, CRI ≥ 80, THD <5%, Power factor >0.95. Integral switched ON-OFF Driver with\inbuilt SPD 4KV and IP 65 protection control unit, all mounting and installation accessories. |
| 69 | Supplying and fixing of SMC junction /pole box having size not less than 200mm x140mmx95 mm minimum IP 65 rating, Din mounting with 6-amp MCB support i/c 20mmx3mm Aluminium bus bar support connection, earthing i/c complete fixing and connection as required. |
| 70 | Pro1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 71 | Supplying and installation following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c baseof suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc. as required. |
| 72 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 73 | 200 mm width X 50 mm depth X 1.6 mm thickness |
| 74 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 75 | Providing and fixing of 4.5Kg Carbon Dioxide type (Co2) fire extinguisher confirming to IS 15683 duly enamel painted fully charged, wheel release type valve, delivery hose horn locking arrangement, operating temperature: 30 Deg C to +55 Deg C i/c wall mounting MS. bracket etc. complete as required. |
| 76 | Supplying and laying of rubber Mat of dimension as required as customised as per floor of site having thickness 2.5 mm to withstand 1.1Kv dielectric strength as per latest IS 15652-2006 etc. as required. Please Enable Macros to View BoQ information |