| 1 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge 1:3:6 or richer mix (i/c equivalent design mix) Manager bathroom |
| 2 | Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 3 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thickcompacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 6 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 7 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 8 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) shleves |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels) |
| 11 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 12 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, ll as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Charge but excluding the cost of painting with: 12.5 mm thick tapered edge gypsum moisture resistant board |
| 13 | Providing and fixing aluminium work for doors, windows, ventilatior and partion with extruded built up standard tubular section,Z section and other sections of approved make and ISI 1285, fixed with dash fasteners of required dia and size including necessary filling up the gaps at the junction i.e.0top, bottom and sides with required EPDM rubber I neoprene gasket felt etc. Aluminium section shall be smooth,rust free, straight,mitred and jointed mechanical wherever required including cleat angle, aluminium snap beading for l panelling,C.P.brass stainless steel screws,all complete,For fixed portion . Powder coated aluminium. |
| 14 | For shutters of doors, windows & ventilators including providing and fixing hinges l pivot and making provision and fixing of fittings wherever required including the cost of EPDM rubber gasket required. |
| 15 | P/F of (3.5 to 4mm)thick ACP sheet including all fittings complete job . |
| 16 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) |
| 17 | Renewing glass panes, with wooden fillets wherever necessary Float glass panes of thickness 5.0 mm (weight not less than 12.5kg/sqm) WINDOWS |
| 18 | Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868 tower bolt200x10mm |
| 19 | Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868tower bolt150x10mm |
| 20 | Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868handle 125mm |
| 21 | Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868handle100mm |
| 22 | Labour engaged for dismentalling of false celing including disposal of material all complete job5 labour for 10 days |
| 23 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead.For thickness of tiles 10 mm to 25 mm |
| 24 | Supply and Installation of Federation Internationale de Basketball Association (FIBA)/Badminton World Federation (BWF) Approved Maple hardwood sports flooring sourced from Maple Floors Manufacturers Association (MFMA) approved/certified mill of US/Canadian origin.Flooring with 21-22mm thickness of each individual strip. Minimum width of 129 mm and of random length 1830 mm.Flooring shall be jointed together with the help of tongue and groove on all four sides of all board.Substructure of maple wood flooring shall consist of anti termite treated sleeper of Spruce or Pine having 63-75 mm wide and cross section of 38-45 mm and laid perpendicular to the main flooring planks at a spacing 350- 411mm centre to centre including 19 mm thick rubber pads at 411mm centre to centre spacing and poly- ethylene membrane 0.20 mm (vapour barrier) installed over the concrete base beneath the flooring system.Game line marking in accordance with manufacturers specifications and project drawings etc. complete to the satisfaction of the Engineer incharge.Details of the MFMA approved mill and batch no shall be engraved on the backside surface of the maple wood planks and the wood should be sports lacuqer pre finished and pre sanded.Warranty of the flooring against manufacturing defects to be atleast 5 years. |
| 25 | Supply & Installation of shock absorbing, Anti Skid, Abrasion Resistant & Easy to Maintain Badminton World Federation (BWF) Grade 1 approved synthetic heteregenous indoor vinyl flooring with an overall thickness of 4.5 mm in single court form and pre marked with badminton game line marking and BWF logo. Flooring having wear layer of minimum 1.5 mm, comprising of Glass Fibre Tissue reinforced with low shrinkage dimensional stability: Weight: minimum 2.30 kg/m2, Shock Absorption: 30%, Sliding Coefficient: 0.42-0.60, Energy Return: 0.42, Vertical Deformation less than 1.5 mm, Abrasion Resistance: 0.15. Residual Imprint: 0.15 mm, Resistance: >6, Chemical Resistance: Excellent, Dimensional Stability: <0.1%. with PUR surface Protection.The Product Should be of European/US Origin only with warranty of 5 years and shall be installed after prior approval of Engineer Incharge. |
| 26 | 25 mm on G.I NRC1 on Walls Providing of tiles made of Wood Fibre 1mm width cement composites 25 mm thick with an option of colours as per the choice of the Architect/ person in charge of size 600X1200 mm. Has excellent noise absorption of 1 NRC as per ISO:354-1985 and ASTM 423-90 a, Density 400 Kg/ m3, meets stringent Fire Ratings ASTM D- 876 and BS:476 weather resistance as per IS 3308, Thermal Insulation as per IS:3346-1980 with relative humidity of 90% RH at 600 Celcius(1400 Farenhite) for 15 days= No deterioration. Conforms to En 131682001 and are RoHS Complaint. To be installed with Aluminum H Profile G.I studs 600x600mm centre to centre 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration management and long life 50mm thick, 1000 GSM absorb wool tested as per Fire Retardant ASTMD 635-1991/Insulation and IS 15061-2002 for excellent Hall walls |
| 27 | 25mmnBaffles for Ceiling Providing of baffle tile made of Wood Fibre 1mm width cement composites 25 mm thick with an option of colours per the choice of the Architect/ person in charge of size 600X1200 mm. Has excellent noise absorption of 0.74 NRC as per ISO: 354-1985 and ASTM 423-90a, Density 400 Kg/ m3, meets stringent Fire Ratings ASTM D- 876 and BS:476weather resistance as per IS 3308 Thermal Insulation as per IS:3346-1980with relative humidity of 90% RH at 60o Celcius(1400 Farenhite) for 15 days=No deterioration. Conformsto En 131682001 and are RoHS Complaint To be fastened directly on the ceilings Hall roof |
| 28 | Pre & post RT -60 testing before & after completion of acoustics work and their results |
| 29 | Providing and fixing precoated galvanised steel sheet roofing accessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter .(600 mm over all girth |
| 30 | P/f of silicon tube for water proofing |
| 31 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.110 mm diametre |
| 32 | Supply and fixing of HDPE Spectators chairs with following chairs with following specification:- 1) seat dimension = 415mmx450mmx700mm (from ground ) with minimum 3mm and maximum 8mm wall thickness all over the profile .2) seat shell should be blow moulded high polyethylene with uv protection dual wall with air gaps gives comfort and softness while seating on the seat with molded insert M6 threaded nut to mount on the stand & water drain hole of dia 20mm.3) Mounting beam shall consist of 2 steel pipes of OD 34 & ID 28 mm 3 mm wall thickness with hot dip galvanizing to prevent from crossion in open air running across the length of desired length of seating .4) Mounting bracket =MS 203x40mm 3mm thickness metal embosed bracket inter locked by bolt and nut with pipe and bracket size 110x35mm with 3mm thick embosed bracket with hot dip galvanising to prevent from crossion in open air.5) Leg type =Floor mounted aluminium die casted (ADC12) Stand of 335x240mm for strong leg support with powder coated 50micron thickness 6)Mounting dimension =CTC can be managed with the mounting brackets on pipe to mount in different sizes which gives flexibilty of mounting CTC(minimum 420mm & maximum depending as per required space between 2 seats) |
| 33 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 34 | 12mm Cement plaster of mix 1 : 6 ( 1 cement : 6 fine sand) |
| 35 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work. |
| 36 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.15mm nominal outer dia pipes. |
| 38 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, withall fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 39 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Flat back wash basin size 550x400 mmwith single 15 mm C.P. brass pillar tap. |
| 40 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 41 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively. |
| 42 | Providing and fixing PTMT grating of approved quality and colour 100 mm nominal dia. |
| 43 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 1 02mm, heigth of 75mm with concealed fitting arrangements, weighing not less than 106gms |
| 44 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour:600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms.s |
| 45 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 46 | Providing and fixing small bib cock of approved quality. 15 mm nominal bore |
| 47 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 48 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms |
| 49 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe 32 mm dia |
| 50 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 15mm nominal outer dia pipes. |
| 52 | P/F of soap dispenser |
| 53 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. 16/18 mm Granite Stone of approved shade |
| 54 | P/F stainless steel water cooler(80ltr capacity) with RO of make Voltas, Bluestar or equivalent having valid IS certification including pipes, electric point and 6 module with box, switch, socket,etc. for connection as per direction engineer incharge |
| 55 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railingwith necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).bench |
| 56 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 57 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm |
| 58 | Design, Supply, Fabrication and Erection Architectural Membrane System for custom designed to withstand the design wind pressure of 180 kg/sqmtr confirming to IS-875 part-III. (The system must pass the proof test at 1.5 times design wind pressure i.e. 285 kg/sqmtr PVDF coated fabric of the teaching width of 60mm with high frequency 20kw machine. The fabric structure shall be frame supported tensioned membrane Structure. The weight of fabric shall be Crosslinked Pvdf & Precontrant Serge Ferrari Coating 1050 GSM or MEHLAR VALMEX MEHATOP N FR 1000 , SATTLER Atlas Type 111 or 1050 Gsm .The fabric shall have low elongation not more than 1..25% Characteristics under tension and shall assume an Anticiastic configuration. Structure that have designs incorporating. The fabric shall be polyester based with PVDF coating and Precontrant. The fabric shall be solvent resistant, UV resistant with 15 year warranty. The said work is to be got Executed only through specialized Agencies with Authorization Letter Specially for Said job as per instructions of engineer-in-charge, STRUCTURAL STEEL WORK Providing, Fabricating, Assembling, Hoisting, erecting and placing in position MSBuilt-up section/Tubular Structure (MS built-up section:- Rolled section & plates confirming to IS 2062, TubularStructure:- made from steel hollow section (CHS/ RHS/SHS), ISI marked conforming to IS 1161/4923, (fromTATA/ JINDAL/ Apollo) in the profile shape as per conceptual drawings with special plate connector, joints,Plates, hollow sections etc. for obtaining smooth - dimensional curvature.lding process with special plate connectors, pinion joints, plates, hollow sections, including Preparation ofdetailed fabrication and erection drawings of Structural steel work from design drawings, transportation fromfabrication yard, cutting , threading, machining, leads and lifts up to all heights, tools & plants and necessary. |
| 59 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent. |
| 60 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work |
| 61 | P/F of 4 feet led tube light incl. testing , commission complete . |
| 62 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: |
| 63 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 64 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x450x50 mm reinforced with 8 mm dia four nos longitudinal and 9nos cross sectional T.M.T hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S flats of size 50mmx1.6mm complete all as per direction of Engineer-in-charge. |
| 65 | Sand by mechanical transport |
| 66 | Aggregates by mechanical transport |
| 67 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die castaluminium body with built in or separate driver asper the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR -15, lenses for beamangle 30 deg-120deg as per the application and theproject requirement., suitable tilt able fitting, life time(LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumenmaintained till life ends as per LM80extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5,Maximum power consumption should not morethan the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/cexternal connections with 1.5 sq mmFRLS/HFFR, PVC insulated copper conductorsingle core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output .LM79 & LM80Test report and all testing required for LEDfixtures as per BIS shall be submitted.. Shape sizeand CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LEDjunction temperature shall not rise above 90°C). |
| 68 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 69 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch |
| 70 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 71 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet |
| 72 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 73 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 74 | Supplying and fixing 63 amp SPN rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 75 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp |
| 76 | Supply, Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. light Bulb 9 watt |
| 77 | Installation testing and comissioning of 2X2 Recessed luminaire with LED (Light Emitting Diode) maximum system power: 36 W, minimum Luminous flux of luminaire 100 Lm/w, Colour temperature of 0 K, Neutral white, CRI > 80, R9>0, THD<5%, P.F>0.95, Driver Efficiency>88%, SDCM<3, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, 1.4 mm thick extruded aluminium profile with Polyester powder white coloured coat applied over a 5- stage pre-treatment, Protruded Prismatic diffuser for glare-free uniform illumination, UGR<16, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, Electronic control gear, Protection class I, IP 40 |
| 78 | Installation testing and comissioning of linear surface wall mounted 20 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 4000 lumens and maximum system wattage of 12W; Dimension :- 595 mm Body of extruded aluminium profile and polycarbonate cover. |
| 79 | Installation testing and comissioning of linear surface wall mounted 36 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 4000 lumens and maximum system wattage of 12W; Dimension :- 1200 mm Body of extruded aluminium profile and polycarbonate cover. |
| 80 | Installation, testing and commissioning of 200 mm sweep exhaust fan with robust motor, gravity shutters with speed rating of 1350 revolution per minute complete with all accessories etc. directly on ventilator , including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 81 | Supplying and fixing of ceiling fan of followingsweep with 2.25 mfd condenser and 1'-6\\" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. 1200 mm sweep |
| 82 | P/F of 300mm exhaust fan of havells or eqvt. Make incl. testing , commission complete . Please Enable Macros to View BoQ information |