| 1 | Surface dressing n exc 15 cm deep and getting out soft/loose soil complete all as specified and as directed by engr-in-charge. |
| 2 | Excavation in trenches n exc. 1.5m wide and not exc 1.5m in depth and getting out in soft/loose soil for foundation etc. complete all as specified and as directed by engr-in-charge. |
| 3 | M&L Cement concrete 1:4:8 (40mm graded stone aggregate) as in foundation, filling and mass concrete, complete all as specified and as directed by engr-in-charge. |
| 4 | M & L Cutting openings through walls for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry in cement mortar for under- pinning including providing, fixing and removing, shoring (Hydraulic jack), cleaning and stacking stone and removing surplus to store and rubbish off the premises all as specified and as directed. |
| 5 | Demolition of Cement Concrete of any description (plain/reinforced)and in any position not otherwise specifically provided for & removal of rubbish outside MD land all as specified and directed. |
| 6 | Demolition of brick work built in cement mortar including all arches, pillars all quoins etc complete all as directed. |
| 7 | Taking down chowkats or frames with shutters ( without taking off shutters from the frame)exc 1.5 sqm but n.exc 4 sqm each and removing to store. |
| 8 | Taking down chowkats or frames with shutters ( without taking off shutters from the frame) n'exc 1.5 Sqm each. |
| 9 | Dismantling asbestos cement (corrugated/ semi corrugated etc) sheet in roof covering complete all as specified and directed. |
| 10 | Dismantling MS works of any Desc. Not otherwise provided for |
| 11 | M&L for brick work with sub class 'B' bricks straight or curved on plain exc. 6m mean radius built in CM 1:6 |
| 12 | M & L Damp proof course 40mm thick (in cement concrete 1:2:4 Type B-0) to horizantal or vertical surface including necessary formwork and comolete all as specified and directed. |
| 13 | M&L for 15 mm thick rendering in cement mortar 1:4 on concrete block masonry finishing even and smooth without using extra cement .complete all as specified and as directed by engr-in-charge. |
| 14 | M&L for 10 mm thick rendering in cement mortar 1:6 on concrete block masonry finishing even and smooth without using extra cement .complete all as specified and as directed by engr-in-charge. |
| 15 | M&L for preparation of new plastered surfaces of walls & applying two coats of oil emulsion distemper over a coat of primer all as specified and as directed. |
| 16 | M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint complete all as specified. |
| 17 | M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering |
| 18 | M&L for hardcore of guge broken boulders or stone n exc .63 mm, deposited, spread and levelled in layers n exc. 15 cm thick waterd and rammed t a true surface complete all as specified and as directed by engr-in-charge. |
| 19 | M&L for 40 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone agg in sub base of floor.complete all as specified and as directed by engr-in-charge. |
| 20 | M&L for joint free Non-skid coloured Ceramic tiles of size 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified. |
| 21 | M&L for joint free glazed coloured ceramic tiles 350 mm x 250mm/450mmx300x7 to 7 mm thick as in vertical surfces set & jointed in neat cement slurry & pointed in coloured cement incl backing coat 10mm thick in CM 1:3 all as direced. |
| 22 | Providing and carrying out water Proofing treatment to toilet, sunken slabs, wet areas ets, after proper surface prepration, carry out cementitious injection grouting at leakage point using cebex 100 plasticised expanding grounding admixture, application of polymer modified at slab wall junction using Nitoband SBR latex screen modifier cum bonding agent and application of two coat of brushbond RFX two part acrylic polymer modified cementitious elastomeric waterproof and protective coating etc, complete including 15mm thick cement plaster in CM 1:4 all tools and plant as per manufacturers specification including removal & refixing/replacement of fixtures complete all as specified and directed. |
| 23 | S & F in repair for CI nahani trap/floor trap incl jointing to waste pipe fixed in cement concrete 1:2:4 (Type B-2), 75mm diameter with gratings incl taking down old broken traps. |
| 24 | M&L cement concrete type E-2 1:5:10 using 40mm, graded brick agg as in sub base. |
| 25 | M&L rendering 15 mm thick in cm 1:4 in sunken portion on Brick / stone masonry surfaces, incl water proofing liquid @ 200ml per 50Kg cement. ((water proofing liquid to be measured separately) including finished even and smooth. |
| 26 | Supply only Liquid water proofing compound |
| 27 | M&L for PCC type C-2, (1:3:6, using 40mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge. |
| 28 | S/F 40 mm dia CPVC pipe (out from sunken portion) for spout. |
| 29 | S&F vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistem & fush pipe fixed in repairs incl \\"P\\" or \\"S\\" trap. |
| 30 | S & F in repairs for Wash Hand basins, Vitreous China, white, flat back, size 550x440mm, including cutting for and pinning in ends of brackets or erecting stand, angle bracket (but exclusive of fixing of supply, waste pipe, taps) complete all as specified and directed. |
| 31 | S&F in repairs CP bib taps 15mm dia fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed. complete all as specified and directed by Engr In Charge. |
| 32 | S & F in repairs CP Angle stop valve of cp any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms |
| 33 | S&F in repairs 15mm dia stop valves screwed down fancy type chromium plated, screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed by Engr In Charge. |
| 34 | Supply & fixing in repairs 15mm pillar taps fancy type chromium plated, with capstan heads, screwed down , high pressure, with long screwed shanks and fly nuts, screwed for iron pipe and fixed. Bore of pipe in 15mm complete all as specified and directed by Engr In Charge. |
| 35 | S&F for waste coupling of PTMT for 32 mm bore dia of discharge pipe (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) |
| 36 | M & L for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) |
| 37 | M & L for Towel Ring of cp fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) |
| 38 | M&L in repairs Supplying and laying of 20mm OD CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified |
| 39 | M&L in repairs Supplying and laying of 25mm OD CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified |
| 40 | Supply & Fixing PVC door frame (50x47) mm made out of plain colour 5 mm thich PVC Sheet re in forced with MS Square Tube, supplying & fixing in opening as per specification & drawing |
| 41 | S&F factory made solid panel PVC door shutter 30 mm thick ( Style ) consisting of frame made out of MS Tubes for top & bottom rails.MS frame shall be covered with heat moulded plain colour PVC ' C 'Channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC Sheets for top rail , lock rail & bottomrail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC Sheet to be fitted in the MS Frame welded / sealed to stiles & rails with suitable PVC Sheet beading, jointed together with solvent cement,supplying & fixing in the frame at site as per specification & drawing. |
| 42 | Disconnecting existing PVC water tanks of capacity exc 500 & n.exc 1000 litres, setting aside (or lowering if required) for refixing complete all as specified and as directed. |
| 43 | M&L PCC (1:3:6) type C-1 using 40mm graded stone agg 75mm thick as in plinth protection finished even and fair without using extra cement.complete all as specified and as directed by engr-in-charge. |
| 44 | Returning filling in including speading,leveling ,watering and well ramming in layer complete all as specified and directed by Engr-in-charge. |
| 45 | M&L removal of excavated Soil to a distance n exc 50m and depositing where directed. |
| 46 | S&F for pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 125 X 60mm. |
| 47 | M&L PCC (1:3:6) type C-1 using 20mm graded stone agg filling of pressed steel door frame complete all as specified and as directed by engr-in-charge. |
| 48 | S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engr-in-charge. |
| 49 | Supply & fixing MS barrel tower bolt of 100mm long stove enamelled black with bright bolt complete all as specified and directed by Engr-in-charge. |
| 50 | Supply & fixing 300 mm long mild steel sliding door bolts plate type stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts four on bolts plate and two on couple plate and fixed complete all as specified and directed by Engr-in-charge. |
| 51 | S&F 100mm long MS butt hinges medium weight cold rdlled. |
| 52 | Supply & fixing MS pressed handle oval type stove enamelled black of 125mm long fixed with screw to shutter complete all as specified and directed by Engr-in-charge. |
| 53 | M & L for preparation and applying two coat of synthetic enamel paint on wooden surface over one coat of pink primer complete all as specified and directed. |
| 54 | S & F powder coated aluminum frame for doors, windows & ventilators with one or more rebate inlcuding jointing cleats and alike for fixing complete |
| 55 | S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, srews with powder coating of any colour (Thickness or powder coating not less than 50 micron) including stainless steel wirecloth 0.36 mm nominal dia of wire and average aperture 1.40 mm and fixed with stanless steel wire staples. and 3.0 mm th sheet glass ordinary quality plain and glazing Complete all as specified and directed. |
| 56 | M & L for providing reinforced cement concrete M25 Design Mix using 20 mm graded stone aggregate as beams , cantilevers, bressummers , lintel over 1.5 mtr span complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item) |
| 57 | M & L for providing reinforced cement concrete M25 Design Mix using 20 mm graded stone aggregate as foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item) |
| 58 | M&L formwork to side and soffits of floor or roof beam beam hauching, girder bressummers ,lintels cantilivers shelves including supports overhangs etc. also splays between floor and beams stc. complete all as specified and as directed. |
| 59 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 60 | M&L for TMT bar 10mm dia and over cut to length bend to shape required and binding with mild steel wire annealed not less than 0.9mm dia. complete all as specified and as directed by engr-in-charge. |
| 61 | M&L for TMT bar 6mm to 8mm dia as in stirrups cut to length bend to shape required and binding with mild steel wire annealed not less than 0.9mm dia. complete all as specified and as directed by engr-in-charge. |
| 62 | Material and labour 100 mm thick plain cement concrete (1:4:8) type C-2 (using 40 mm graded stone aggregate) as in the sub base of floor complete all as specified. |
| 63 | M & L for Rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)Fe-410 gd E-250 quality B |
| 64 | S & F 0.5 mm thick pre painted/coloured galvalume Al zin coating GI based corrugated steel sheet of an colour having tensile strenth of 550 Mpa as in roofing fixing all as per manufactures instructions fixed on roof with all fittings and accessories. |
| 65 | All as per item No 64 but plain sheet as in ridge, etc |
| 66 | M& L Chequered Cement Concrete Tiles 30 CM x 30 CM X 25 mm th set and jointed in cement slurry and pointed in neat grey cement & pigment in floors over screed bed 15 mm thk in cm 1:6 .complete complete all as specified and as directed. |
| 67 | Dismantling / taking down AC waste/vent pipes fixed to walls with all fittings/ accessories 100 mm dia pipes. |
| 68 | S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm. |
| 69 | S&F.110 mm dia PVC (SWR) bends, any radius with access door |
| 70 | S&F 110 mm dia PVC (SWR) vent cowl |
| 71 | Demolition of brick work built in cement mortar including all arches, pillars all quoins etc complete all as directed. |
| 72 | Excavation in trenches n exc. 1.5m wide and not exc 1.5m in depth and getting out in soft/loose soil for foundation etc. complete all as specified and as directed by engr-in-charge. |
| 73 | Demolition of plain cement concrete of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) for all as specified |
| 74 | M & L for modular size Flyash brick work st or curved on plan exceeding 6 mtr mean radius and built in cm 1:6 |
| 75 | M & L PCC 1:4:8 as in foundation, filling and mass concrete etc complete |
| 76 | M&L for cement concerete 1:2:4 Type B-2 Using 40 mm graded stone aggregate as in surface channel and drain bed wall and floor etc. |
| 77 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. |
| 78 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces finished even and smooth in cement mortar 1:4 complete all as specified |
| 79 | Returning filling in including speading,leveling ,watering and well ramming in layer complete all as specified and directed by Engr-in-charge. |
| 80 | Removal of surplus soil to a distance n exc. 50 M & depositing where directed at a level n exc. 1.5 M above starting point. |
| 81 | M & L for PCC 1:3:6 type using 20 mm graded trap stone aggrgate in coping all as specified and as directed. |
| 82 | M & L for framed work such as grill, gratings, etc with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work corn-conforming to Fe.290. Gde -E-165, complete all as specified and directed. |
| 83 | M&L for preparation of new surfaces of steel of any description over 10cm in width or girth apply two coats of synthetic enamel paint over a coat of Red oxide primer complete all as specified. |
| 84 | Demolition & breaking up drain pipe (salt glazed , AC or reinforced concrete) set in cement mortar for 150 mm dia pipes. |
| 85 | M&L for reinforced cement concrete pipes class NP-2 , laid in trenches & jointed complete with collars, dia of pipe 150 mm . |
| 86 | M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in bed to drain pipes, incl packing under & hauching against the sides of pipes after they are laid and tested for 150 mm bore RCC pipe. |
| 87 | Supply and fix hume pipe septic tank 25 users capacity including all excavation earth work required and demolition and removal of old septic tank (any size) and removal of debris,including vent pipe,cowl,rcc covers,plasters and connecting the new septic tank to the incoming sewer lines and connected to soak pit as directed. |
| 88 | Excavation in trenches n exc. 1.5m wide and not exc 1.5m in depth and getting out in soft/loose soil for foundation etc. complete all as specified and as directed by engr-in-charge. |
| 89 | Demolition of plain cement concrete of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) for all as specified |
| 90 | Returning filling in including speading,leveling ,watering and well ramming in layer complete all as specified and directed by Engr-in-charge. |
| 91 | Removal of surplus soil to a distance n exc. 50 M & depositing where directed at a level n exc. 1.5 M above starting point. |
| 92 | Demolition of Cement Concrete of any description (plain/reinforced)and in any position not otherwise specifically provided for & removal of rubbish outside MD land all as specified and directed. |
| 93 | Demolition of brick work built in cement mortar including all arches, pillars all quoins etc complete all as directed. |
| 94 | Dismantling MS works of any Desc. Not otherwise provided for |
| 95 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc.Getting out and getting out in soft/loose soil all as specified and as cdirected. |
| 96 | Boring 300 mm dia holes 4 m deep in soil for under-reamed piles and getting out and disposal of spoil to a distance of n exc. 50 m |
| 97 | M & L for PCC 1:4:8 type D2 (using 40mm graded aggregates) as in Foundation filling and mass concrete all as specified and directed and as shown on drawing. |
| 98 | M & L RCC M 25 Design Mix (Using 20 mm Graded Stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beam, bases for columns,bands etc. under-reamed piles etc all as specified and directed and as shown on drawing. |
| 99 | M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams,bands and similar work; vertical or to batter for rough finished of surface of concrete flat all as specified and directed. |
| 100 | M & L RCC M 25 Design Mix (Using 20 mm Graded Stone aggregate) in Columns, pillars, piers, posts and struts all as specified and directed and as shown on drawing. |
| 101 | M & L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished of surface of concrete flat all as specified and directed. |
| 102 | M & L for PCC type B1(1:2:4, using 20mm graded stone aggregate) as in bed blocks/coping/ edging including use & waste of formwork for fair finished surfaces complete all as specified and directed. |
| 103 | Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1 1:3:6 (20 mm graded aggregate ) and setting in mortar CM 1:6, complete. |
| 104 | M & L high strength corrosion resistant TMT bars, grade Fe-500 D, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips complete all as specified and as directed. |
| 105 | All as per item no 104 above but 5 mm dia and over upto and including 10 mm dia as in stirrups. |
| 106 | M & L for 15 mm thick plaster in CM (1:4) on fair faces of brick work or concrete surface with sponge finish. |
| 107 | M&L for 10 mm thick rendering in cement mortar 1:6 on concrete block masonry finishing even and smooth without using extra cement .complete all as specified and as directed by engr-in-charge. |
| 108 | S & F angle independently with web and flange cut to shape drilled and countersunk for screws including bending and welding angles without connecting plate as bracket in posts and struts in fencingincluding cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified and directed |
| 109 | Restraining & Reseucring including making good staples of Galvanised. 4 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc all as specified and as directed by Engr-in-Charge. (each line wire to be measured) |
| 110 | S & F in repairs Galvanised. 4 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc all as specified and as directed by Engr-in-Charge. (each line wire to be measured) |
| 111 | M&L for preparation of new surfaces of steel of any description over 10cm in width or girth apply two coats of synthetic enamel paint over a coat of Red oxide primer complete all as specified. |
| 112 | M & L for preparation of surfaces of new plastered surface of wall and applying two coat of cement base paint over wet surface complete all as specified and directed. |
| 113 | M & L for preparation of old surfaces of wall and applying two coats of cement base paint over wet surface complete all as specified and directed. |
| 114 | Returning filling in including spreading, levelling , watering and well ramming n exc. 25 cm in layers (Soil) |
| 115 | Removing excavated soil n exc 50m lead and deposited where directed at a level not exceeding 1.5M above from the starting point complete all as specified and as directed by Engr-in-Charge. |
| 116 | Providing and fixing concertina coil fencing with punched tape concertina coil 610 mm dia having 50 turns and stretches to cover 5-7m length and approx weight 8.75kg + 5% and fixed in existing angle iron Y shape including necessary clips or wires tied to GI barbed wire all complete as per direction Engineer in charge |
| 117 | M & L for Removing building materials from MoD land etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of exc 1km but n.exc 5km, beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and as directed by Engr-in-charge |
| 118 | Supply,laying,jointing , testing and commisioning XLPE cable 1100 volts grade PVC insulated armoured & PVC sheathed with stranded aluminium conductor heavy duty ISI marked incl cable glands lugs bolts nuts washers etc to suit the cable size to be laid in trenches fixed along pole, LT pannel floor bore or through GI pipe laid under floors, Fixed, concealed in wall encased in GI pipe etc complete of following sizes including taking down old unserviceable over head conductors and insulators channels carefully as directeed by engineer in charge Make : polycab/ havells/ Gloster |
| 119 | 16 Sqmm x 4 Core |
| 120 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all as specified and directed :- |
| 121 | Soft / loose soil |
| 122 | Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed. |
| 123 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed by Engineer -in-Charge. |
| 124 | M & L for HDPE DWC pipe ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection of the following outer dia :- Make:-Infra/Supreme/Prince |
| 125 | 40 mm dia |
| 126 | M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) complete all as directed by Enger -in- charge. |
| 127 | M & L of new Gl steel tube Light grade galvanized of size 80 mm dia with all fitting laid in trenches complete and all as specified and directed by Engr in charge. Make : Jindal/ Tata/ Prakash Surya/ Ravindra./Swastik |
| 128 | Taking down old point wiring & M&L for point wiring with 1.5 sqmm two single core multistranded copper conductor cable of PVC insulated and unsheahed type alongwith 1.5sqmm PVC insulated unsheathed single stranded copper conductor cable for continous earthing in & incl casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/(MS steel strips if required) including hard PVC boards of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator setc for Note:- Screws used for fixing PVC boards, casing & caping ceilling rose square blocks etc should be nickel cadmium screws Make - poly cab/RR/ Havells or equivalent |
| 129 | All as per item No 126 but one light point controlled by one switch |
| 130 | All as per item No 126 but One fan point controlled by one switch & regulators |
| 131 | All as per item No 126 but One socket 5 pin 5 Amps flush type on independent board |
| 132 | All as per item No 126 but One socket 5 pin 5 Amps flush type on same board |
| 133 | M&L for point wiring with 2.5 sqmm two single core multistranded copper conductor cable of PVC insulated and unsheathed type alongwith 2.5sqmm PVC insulated unsheathed single core multistranded copper conductor cable for continous earthing in & incl PVC casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/ (MS steel strips if required) including hard PVC boards/Boxes of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator etc . Note:-color coding to be followed as given R-Phase,B-Neutral & G- Earthing |
| 134 | S&F switch piano flush type single pole one way 6 Amps |
| 135 | S&F switch socket combination 2 in 1, 5 Amps flush type |
| 136 | S&F switch socket combination 2 in 1, 15 Amps flush type |
| 137 | S&F lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings |
| 138 | S&F ceiling rose surface type 65 X 50mm, isolated body with 3 terminals to be fixed on PVC block |
| 139 | MCB DB SPN sheet metal enclosure double door suitable for mounting MCB 240 volts with 200 Amps rated busbar 8 way |
| 140 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP , 5- 32 amp to fit in the MCB DB complete with connection testing and commissioning. |
| 141 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN ,32 amp to fit in the MCB DB complete with connection testing and commissioning. |
| 142 | Supply and fixing in replacment of LED lights fitting 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.Make : Havells / Bajaj /Philips / Crompton |
| 143 | S & F in repair LED lamp pin type 09 watt all as per directed by Engr In Charge Make : Havells / Bajaj /Philips / Crompton |
| 144 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make : Havells / Bajaj /Philips / Crompton |
| 145 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 225 mm Make : Havells / Bajaj /Philips / Crompton |
| 146 | M&L for earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick burried burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level duly connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel all as shown in electrical plare No 3,connected to earthing test point all as specified or indicated including testing on completion including excavation and earth work in any strata,PCC Chamber with cover,Charcoal and Salt as required & 15 mm Light Grade GI pipe from steel plate to DB in order to ensure satisfactory earth resistance result to the entire satisfaction of Engr-in-Charge. Please Enable Macros to View BoQ information |