| 1 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed |
| 2 | Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5m depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed. |
| 3 | Plain cement concrete 1:4:8, type D2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 4 | Reinforced cement concrete (Nominal Mix) type B1, 1:2:4 (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 5 | Reinforced cement concrete (Nominal Mix) type B1, 1:2:4 (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 6 | Reinforced cement concrete (Nominal Mix) type B1, 1:2:4 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 7 | Formwork to sides of concrete foundation, footings, bases of columns, rafts and raft beams and similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed. |
| 8 | Formwork to sides of pillars, posts, struts, columns (square, circular rectangular on plan or polygonal etc. for rough finished surfaces of concrete, complete all as specified and as directed. |
| 9 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete, complete all as specified and as directed. |
| 10 | TMT bars 10mm dia and over, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete, all as specified and as directed. |
| 11 | TMT bars 6 to 8mm dia as in stirrups, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete all as specified and as directed. |
| 12 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed. |
| 13 | Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 14 | Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:6, complete all as specified and directed. |
| 15 | Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified and directed |
| 16 | Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified. |
| 17 | Rendering 15mm thick in cement mortar 1:6 on brickwork or concrete surfaces or surface other than fair face of brickwork or on one side of lathing, finished even and smooth without using extra cement, complete all as specified. |
| 18 | Preparation of new plastered surfaces of walls and applying two coat of cement base paint over a coat of alkali-resistant priming paint complete all as specified and directed. |
| 19 | Preparation of new plastered surfaces of walls and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed. |
| 20 | Hard core of broken stone gauge exceeding 63mm and not exceeding 100mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surfaces, complete, all as specified and directed. |
| 21 | Plain cement concrete 1:3:6, type C1 (using 20mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 22 | 75mm thick plain cement concrete 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in plinth protection etc, finishing surface even and smooth without using extra cement incl making joints with bitumastic filling in proportion of bitumen and sand 1:3 by weight complete all as specified and directed. |
| 23 | Non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed . |
| 24 | M&L for glazed coloured ceramic tiles in vertical surface 350x250x7 mm/450x350x7mm thick, set & jointed in neat cement slurry & pointed in coloured cement to match the tile over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 25 | M&L pressed steel frame of size 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. including one coat of primer complete all as specified and directed. |
| 26 | M&L plain cement concrete 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in back filling of pressed steel door frames and in bed block for holdfast and similar works etc. complete all as specified and directed. |
| 27 | 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 28 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 29 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 30 | 150 mm long Aluminium anodised,handle of extruded section cast type anodised and fixed complete all as specified and directed. |
| 31 | 200 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 32 | 300mm long Mild steel sliding door bolt , plate type stove enamelled black with bright not less than 12mm dia with and including minimum of 6 bolts and nuts four on plate and two on staples plat and fixed complete all as specified and directed. |
| 33 | 200mm long mild steel barrel tower bolt, stove enamalled black with bright bolt and fixed complete all as specified and directed. |
| 34 | Mild steel pressed handle oval type stove enamelled black size 150mm complete all as specified and directed. |
| 35 | Butt hinges 100mm long, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified and directed. |
| 36 | Steel ventilator with top hung shutters including hinges , steel peg stay, complete all as specified and directed. |
| 37 | 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m complete all as specified and directed. |
| 38 | Mild steel work in framed work such as grills, gratings, framed guard bars, ladders etc. with ends of bars shouldered and / or riveted or forged into spikes, framework of water tanks and similar work confirming to Fe 290.Gde-E-165 compelete all as specified and directed. |
| 39 | Mild steel rolled work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (beam, tee, angle, square / rectangle sections, channel or flat section) including distance pieces, cleats etc. confirming to grade Fe 410-W (Gde E-250) quality-A complete all as specified and directed. |
| 40 | Mild steel screw bolts (machine made) with hexogonal or square heads at one end and screwed the other , or screwed both ends , each screwed end to be fitted with washers and one hexogonal or square nut 11-15 mm dia and exc. 5 cm and n.exc. 10 cm long complete all as specified and directed. |
| 41 | Pre-painted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, fixed with self taping screws, complete all as specified and directed. |
| 42 | Pre-painted galvalume aluminium zinc coating G.I based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering, fixed with self taping screws, complete all as specified and directed. |
| 43 | S&F anodised aluminium snap grid of size 605mm x 605mm frame work for false ceiling complete all as specified and directed. |
| 44 | 4mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/ aluminium frame work with screws fixed in ceiling flat or sloping complete all as specified and directed. |
| 45 | Preparing of new wooden surface exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed. |
| 46 | Preparing of new steel surface exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 47 | 15 mm bore medium grade galvanised steel tubing with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 48 | 20 mm bore medium grade galvanised steel tubing with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 49 | 15 mm bore bore Bib taps cast copper alloy chromim plated ,screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 50 | Stop valve 15 mm dia, cast copper alloy,CP fancy type with screwd down,high pressure,screwed both ends for iron pipes or for unions and fixed in pipe all as specified and directed. |
| 51 | Pillar tap 15 mm dia cast copper alloy with capstan head chromium plated, screwed down high pressure, with or without lettered \\"Hot or Cold\\" with long screwed shank and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 52 | 600 mm long PVC Connection 15mm size with PTMT nuts complete all as specified and directed. |
| 53 | Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed. |
| 54 | Soap dish vitreous China white, any size fixed to plugs with chromium plated brass screws and wooden/ plastic cleats complete all as specified and directed. |
| 55 | Gratings doom 100mm dia of PTMT (Minimum weight 25 gms) complete all as specified and directed. |
| 56 | Towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 190 gms) complete all as specified and directed. |
| 57 | Vitreous china wash hand basin 550 x 450mm, white flat back including cast iron bracket, cutting for and pinning the ends of brackets or erecting on stand including 32mm bore brass chromium plated waste coupling with long screwed shank and fly nuts, PVC flexible waste pipe of bore 32mm and adequate length complete all as specified and as directed. |
| 58 | Vitreous china squating pan, Orissa Pattern, size 580 x 440 mm white with integral foot rests and PVC P or S trap (excluding flushing cistern and flushing pipe ) including connection to trap & flushing pipe etc complete including making good to floor complete all as specified and directed. |
| 59 | Vitreous China wash down water closet pan (pedestal pattern), white (excluding flushing cistern) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, PVC cover sheet in same colour etc complete all as specified and directed. |
| 60 | S&F Vitreous china bowl urinal flat back size 465x355x265 mm white with grating and union for discharge pipe (excluding flushing cistern ,flush pipe and waste pipe) complete all as specified and as directed . |
| 61 | 10 litre capacity PVC valveless, Syphonic action type, fluhing cistern low level,white with inlet ball valve, float and handle, flush pipe etc complete all as specified and directed. |
| 62 | Bevelled edge mirror of slected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified and directed. |
| 63 | 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 64 | 75mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 65 | 75 mm bore dia PVC floor trap (SWR) plain with grating including jointing with solvent cement to waste pipe complete all as specified and directed. |
| 66 | 110mm PVC (SWR) bends any radious complete all as specified and directed. |
| 67 | 75mm PVC (SWR) bends any radious complete all as specified and directed. |
| 68 | Jet suitable for water closet pedastal pattern with pvc conection pipe complete all as specified and directed. |
| 69 | Excavating in post holes (or similar holes) each not exc. 0.5 Cum in any type of soil, getting out returning filling and ramming earth or broken rubble mixed with earth around, in layers not exc. 25 cm complete all as specified and directed. |
| 70 | Plain cement concrete 1:3:6, type C2 (using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 71 | Rotational moulded polyethylene water storage tanks triple layer white in colour (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete of 1000 litre capacity complete all as specified and directed. |
| 72 | 20 mm bore dia of pipe Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm -210 gms ) complete all as specified and directed. |
| 73 | 20 mm bore gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 74 | Septic tank for 10 users, Brick construction with top of slab at ground level including necessary excavation and earth work in any type of soil and disposal of surplus soil to a distance not exceeding 50 metres, vent pipe, supplying and fixing RCC precast manhole cover having 6mm plate embedded all around / fibre reinforced cover with angle iron frame vent shaft and sludge chamber etc., all as specified and shown in Drawing No CE/TD-1202/03 Sheet 1/2 & 2/2. |
| 75 | Soakage well 1.80m internal dia and 3.00m depth including excavation in any type of soil, PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in footing stone honey comb / solid masonry in cement 1:4, RCC cover slab filled with brick bats including intercepting chamber screen chamber and disposal of soil complete all as specified and shown on CE Pathankot Zone TD Drawing No CE/TD-1202/03 Sheet 1/2 & 2/2. 1. During excavation if unexpected water is encountered, the same shall be bailed out / de-watered by the contractor mechanically or manually without any extra cost. 2. The excavated surplus soil shall be removed to a distance exceeding 500mtr and not exceeding 1500mtr and deposited where directed. |
| 76 | Plain Cement concrete type E-2, 1:5:10 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 77 | M&L PCC 1:3:6, type C-1 (using 20mm graded aggregate) as in surface channels and drains complete all as specified and directed. |
| 78 | M&L Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces mixed with water proofing compound as per manufacture's instructions, finished even and smooth without using extra cement, complete all as specified. |
| 79 | Supply only water proofing compound. |
| 80 | M&L Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cills, lintels upto 1.5 metre clear span, steps, seismic and other similar band, plinth course, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stone, bed plates, kerbs etc and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed. |
| 81 | Precast cement concrete type B1 (1:2:4) 20mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles set in cement mortar ( 1:6 ) complete all as specified and directed. |
| 82 | Concrete bed to drain pipes (150 dia) including packing under, and haunching against the sides of pipes after they are laid and tested in cement Concrete 1 : 3 : 6 type C-2 complete all as specified and directed. |
| 83 | M&L Salt-glazed stoneware drain pipes 150 internal dia laid in trenches and jointed as specified |
| 84 | Point wiring with and incl 1.5 sqmm (nominal area) PVC insulated multistranded copper conductor FRLS in PVC caping casing with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal, One light point/fan point controlled by one way switch all as specified and directed . |
| 85 | All as per the description of serial item No-84, here-in-before but for one 3 pin socket outlet 5 Amp independent, complete all as specified and as directed. |
| 86 | Switch piano flush type 5/6 Amp single pole one way, all as specified and directed by Engr-in-charge. |
| 87 | LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED Tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 88 | Ceiling rose surface bakelite 65mmx50mm three terminals complete and making necessary connections all as specified and directed by Engr-in-charge. |
| 89 | MCB DB 4- Way, single door, 240 volts for Sheet Steel, Phosphatised, Powder Painted MCB DBs with Bus Bar,Neutral Link, Earth Bar and Din Rail (In accordance with IS 13032, IS 8623, IEC/BSEN 60439-3) and all specified and directed by Engr-in-charge. |
| 90 | MCB SP 6-32 Amps 'B' series 240V 50Hz 10 KA suitable for lighting and other domestic loads complete including taking down all as specified and directed by Engr-in-charge. |
| 91 | Energy saving 10 Watt LED IP 65 Bulk head luminaries, complete with all accessories, internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size 230V,50 HZ all as specified and directed. |
| 92 | Switch socket combination, 5 pin, 5A flush type universal, all as specified and directed by Engr-in-charge. |
| 93 | Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed by Engr-in-charge. |
| 94 | 32 amp SPN rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 95 | Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including earth lead wire 4.0 mm by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion & dismantling of existing earthing, complete all as specified & directed. |
| 96 | 1100 volts grade heavy duty cable with PVC insulated aluminiuum solid conductor served with an inner sheating of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire one Twin core 10 sqmm solid conductor all as specified and directed by Engr-in-Charge. |
| 97 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick any type of soil, complete all as specified and directed. |
| 98 | Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. Please Enable Macros to View BoQ information |